water meter
Product specification
-9-
Directory
................................................................................................................................ 1. Product Summary-3-
............................................................................................................................................. 3. Functions-3-
-9-
一、Product Summary
Ultrasonic water meter is used to accurately measure the flow rate. The product has the
operation, strong anti-pollution and anti-corrosion capability, long service life, small pressure loss,
economy and practicality, etc. It is suitable for flow metering and charging of domestic water,
Implementation standard: GB/T 778 Measurement of water flow in closed full pipeline
Drinking cold water meter and hot water meter JJG 162-2009 Cold water meter
二、Working Principle
Ultrasonic water meter adopts the principle of ultrasonic wave. It is a kind of water meter that
further calculates the flow rate of water by analyzing and processing the time difference caused by
the change of speed when ultrasonic sound beam propagates downstream and countercurrent in
water.
三、Function List
-9-
2s calculate a flow value;
3 Water Metering For the latest 90 days, the metering data is stored hourly
Data History The latest 180 days, the measurement data is stored every day
Memory Local In the latest year, monthly measurement data are stored
(Precision 1L)
4 Power supply Last applied board power supply (3.6 V)
5 Supply voltage Not supported by current version, not supported by hardware
detection
6 Abnormal half When the exception half interrupt, the log will be automatically
interrupt detection output (mainly used during debugging)
7 EEPROM Save Log Open Flag
Forward flow (1mL) (keep it if there is a difference in one
minute, and consider lengthening it later)
Reverse flow rate (1mL) (keep it if there is a difference in one
minute, and consider lengthening it later)
Pipe section information 15, 20, 25 (use this parameter later and
modify the calculation parameters)
Number of flow points and calibration information
Modbus Address
Meter Address
Historical data preservation (Ref. 3)
8 Valve control Operating motor on-off valve
9 External Interface UART interface (supports CJT188 protocol)
10 CJT188 protocol Refer to CJT188 Protocol Section
11 Infrared Use AT instruction infrared to set/read table parameters (refer to
Configuration (Log AT protocol section below for AT instruction)
Output) Debug Log
四、Performance characteristics
1. There are no moving parts in the ultrasonic water meter body, mechanical wear can be
used stably and reliably for a long time, and measurement accuracy can be maintained for a long
time.
2. The ultrasonic water meter has a large range ratio and a small initial flow rate, and the
range ratio of the water meter can reach: R250, R400; The initial flow rate of the water meter can
be as small as 2-3 liters per hour.
3. The measurement accuracy of ultrasonic water meter is after operation, but factory
inspection can be required according to Grade 1 accuracy standard.
4. Ultrasonic water meter has strong adaptability to fluid temperature changes, and can
achieve T30/T50/T70 temperature grade.
5. Ultrasonic water meter has strong antistatic and anti-magnetic interference capabilities,
and antistatic can reach more than 12000V V.
6. The ultrasonic water meter adopts micro-power consumption design technology to
minimize the comprehensive power consumption of the water meter and has a service life of more
than 6 +2 years.
-9-
7. Ultrasonic water meter can choose a variety of communication modes, such as NB-IOT.
LoRa, LoRaWAN, M-Bus. RS485, pulse, etc., and is equipped with infrared communication
mechanism, through which instrument parameters can be configured or instrument data can be
read.
8. Ultrasonic water meter has the function of long-term data storage, which can realize data
storage and recording of year, month and day, which is beneficial for management departments to
analyze water consumption big data and make reasonable water consumption decisions.
9. Ultrasonic water meter has a water flow direction identification mechanism, which can
measure forward and reverse flow, and can adopt a variety of forward and reverse flow statistics
and display methods, so as to use units for data analysis.
10. The ultrasonic water meter has an alarm mechanism for long-term water running (leakage
alarm) and an oath reporting mechanism for a single water running exceeding a preset amount,
which can timely remind users whether there is water leakage in the household water pipe and
whether they forget to turn off the faucet.
11. The ultrasonic water meter has an empty pipe alarm mechanism, which can be used as an
abnormal disassembly alarm after running water normally for a long time.
12. The ultrasonic water meter has an error counting (instantaneous excessive flow metering)
judgment mechanism. When an error counting occurs, it can give an alarm in time and record the
error time. When an error counting occurs, the MCU software in the meter has an error correction
mechanism, which can prevent the occurrence of an error counting to the greatest extent.
13. Ultrasonic water meter has the function of measuring fluid water temperature, and can
give low temperature or high temperature alarm, so that the management department can deal with
it in time.
14. The combination of ultrasonic water meter and management system can have a family
water care mechanism. When the family children are not with the elderly, the children or the
community where the elderly are located can know the water habits of the elderly through mobile
phone APP, which can give early warning in time.
15. The valve-controlled ultrasonic water meter has a valve control function. The control of
valve opening and closing can be executed by issuing corresponding commands through wireless
communication. In addition, corresponding valve opening and closing conditions can also be set in
the water meter to execute corresponding valve actions.
五、Technical Parameters
Caliber DN15 DN20 ..
-9-
(Q2)
Working ≤ 1. 6MPa
pressure
Level of IP65
protection
Working water 5 ~ 55 ℃
temperature
Communication Lorawan/NB/GPRS/RS485
mode
-9-
七、Installation Requirements
1. Do not place meters with wireless communication in a closed environment, which will affect
2. The installation site shall prevent insolation and freezing, avoid pollution and flooding,
3. Attention should be paid to the protection of hoses and wires during construction. It is strictly
prohibited to pull hoses to carry water meters, so as not to fall off hoses or break wire sheaths.
4, the newly installed pipeline should first remove debris in the pipeline, in order to prevent the
water meter from being blocked. Pay attention to the connection length of the water meter when
-9-
installing the water meter. When the distance between the pipelines at both ends exceeds the
connection length of the water meter, is too short, or is not on the same axis, the distance between
the pipelines should be corrected otherwise the water meter fittings will be damaged or cannot be
installed.
5. If the cold water meter is installed at the inlet end of the boiler, it is necessary to prevent the
boiler hot water and steam from returning and scalding the water meter.
6, long-term use of water meters, due to debris, rust and other blockage in the pipeline, causing
error changes, users are not allowed to destroy the lead seal, can go to the water meter verification
station maintenance.
7. Specifications selected according to pipeline flow. It is advisable that the frequently used flow
rate is close to or less than the commonly used flow rate, and the diameter of the water meter
8. The upper part of the water meter, i.e. the pipeline system, shall use the least number of elbows
and valves. The water meter shall always be filled with water, and the flow rate shall not be less
than 0.005 MPa when it is zero. Air shall be prevented from entering the pipeline. If air may enter
the water meter, a vent valve shall be installed upstream of the water meter to ensure the
-9-
八、 Analysis of Frequently Asked Problems
Problem Problem Analysis
connected to the
2 There are fewer local base stations
Internet
Module not certified
connected to the The environment is closed, the signal is interfered, and the signal is not
Internet good
No flow occurs when Check to see if the water inlet and outlet are installed in the correct
through 2 Remove the water meter to check whether the impeller is damaged
There is a problem Check whether the electricity of the water meter is sufficient. When the
with valve control electricity of the water meter is insufficient, it is difficult to close the
valve
Remove the water meter to check whether there is any problem with the
valve
Whether there is a gap between the upper and lower parts of the rotary
port
-9-
Battery failure Battery undervoltage or poor connection
There is no water in the pipe section or water does not fill the pipe
Empty pipe failure
section
Countercurrent fault The inlet end and outlet end of the pipe section are connected in reverse
9. Packing List
Serial Name Unit Quan
Number tity
1 Ultrasonic valve controlled water meter Only 1
2 Coupling (incl. connecting nut, sealing
washer) (optional)
2. The storage environment temperature (-10 ~ 50) degrees Celsius, the relative temperature
is less than 80%, to prevent strong electromagnetic field and direct sunlight.
3. The products stored in code shall be at least 30CM from the ground and at least 1M from
4. The warehouse shall be kept dry and free of corrosive articles and dangerous goods for
gas.
of delivery (the customer pays extra to extend the free warranty period, with a maximum warranty
2)The components of the ultrasonic valve-controlled water meter were artificially damaged;
3)All parts of ultrasonic valve-controlled water meter suffer from insolation, flooding,
-9-
4)Before installation, the pipeline is not cleaned or there are too many impurities in the
-9-