You are on page 1of 2
SUS AM A 99 BERRA OME Hak KRAR Ha: BD & 44 (500C) HAMS PRATT eS CP in) — > (13%) For the following balanced three- phase system shown in Fig. 1 function of ¥, is v,()=200V2 cos 377, (~)» (6%) Draw the corresponding one line impedance diagram with all the Parameters expressed in per unit (p.u.), the base of phase voltage is 200V and that of line current + 0% tis 20A, ) Find time domain current of 7, ice. inf) » it is known the time domain = * (12%) Consider the following three-bus power system shown in Fig. 2. Assume the transmission line! Impedance of Z is j0.5 p.u. and the power flow Sis as shown in the figure is J3/24/1.0 P.u. Find the voltage magnitude and phase of bus 2, ie., Va and 8, = > (15%) A single-phase line possesses the followin; 2=002+ j0.2O/Kkm, 9 (—) > (8%) Find the nominalen circuit and the corresponding ABCD parameters for a medium-length line of 200km. (=)* (6%) The fine is terminated by ya resistor (R= 1000) as shown in Fi Characteristic impedance. Ze; 2) find the line surge impedance Ze ‘Find the voltage transmission coefficient and reflection eneffieg ¥ + (10%) A non-salient connected to an voltage of ¥, is maintained at rated v: system is ig line constants at 60Hz: = j5%10-S/km ig. 3: (1) find the line (3) for the injecied voltage surge ient, =J15 pu. It is . Pau as shown in Fig. 4, The terminal Pau.) for any loading. If the real power sending to the ) tas (2) (4%) Ey Synchronous ‘generator ‘Transmission fine Terminated resistor Fig. 3 BRS A he Oe 99 EE OL A RA 7 Ha: BA & we (500C MARS HARTER SE (Pia) 4% + (10%) A single line-to-earth fault occurs on phase A at the load end of a 66kV transmission line. The line is fed via a transformer by 11kV generators connected to a common busbar, The line side of the transformer is connected in wye with the neutral earthed and the generator side in delta, The positive sequence reactances of the transformer and fine are j10.9@ and j44 9 respectively, and the equivalent positive sequence and negative sequence reactances of the generators, referred to the line voltage, are j18Q and j14.5 2 respectively. Measured up to the fault the total effective zero sequence reactance is j150.Q, Calculate the fault current in the lines if resistances may be neglected. If a two-line-to-earth fault occurs between phase B line and phase C line at the load end, please calculate the current in the phase C. % + (10%) As shown in Fig. 5, the three-y magnitude V (line-to-line, rms value). (=) > (3%) Please sketch the AC Jine current waveforms. (=) + G%) Calculate the THD value of the AC line current. > (4%) Calculate the average power delivered to the DC side. Assume the diodes are ideal. phase rectifier circuit is powered by balanced AC voltages of “© + (5%) A 600-MVA, 60-Hz turbine-generator has a regulation constant R=0.0Sper unit based on its own rating. If the generator frequency increases by 0.03 Hz in steady-state, what is the decrease in turbine mechanical power output? A + (7%) An area of an interconnected power sy ‘The fuel-cost curves are given as follows: Cy(Pis) = 900 +45 Pay + 0.013, Ca( Pop) = 2500 + 43% yy 40.0032, The load is specified as Po~700 MW. Generator limits are given as SOMHW'< Ry <200MW , SOMW s Pe, < 600MW . Determine the power out the total operating cost. stem has two fossil-fuel units operating on economic dispatch, put of each unit, the incremental operating cost, and A. > (18%) Consider the power system shown in Fig. 6. (=) » (5%) The generator is initially operating in the stead per unit real power at 0.95 power factor (p.f}) laggi the generator, and (2) (2.5%) the electrical power del + (13%) cree ly-state condition. If the infinite bus receives 1.0 ing, determine (1) (2.5%) the internal voltage of livered by the generator versus its power angle. int F. Three eycle later, power angle reaches 35 bicakers teclose, use the ) When a temporary three-phase-to-ground short circuit occurs at poi breakers B,s and Bzz open after 3 cycles and then reclose when a Assume that the temporary fault has already self-extinguished when the equal-area eriterion to determine the maximum value of the power angle. Vo G

You might also like