You are on page 1of 4

Building with Confidence

Flood Superwideslab® Precast Concrete Flooring combines


the advantages of Hollowcore Flooring with the advantages
of Omnia Flooring.

Flood Superwideslab Benefits: ®

• Faster installation. • Better sound insulation system.


• High quality soffit finish. • Awkward shapes are easily
accommodated.
• Spans in two directions.
• Solid slab with no cores.
• Thermal mass and natural ventilation.
• Heavy loads.
• Reduction in building height.
• Immediate working platform
• Can be used to construct a flat for other trades.
slab with no down stand beams. • Reduced beam depth.
• Openings can be easily • Less soffit joints.
accommodated. • Cast in lifting.

floodprecast.ie floodprecast.co.uk
Hilltown, Oldcastle, Co. Meath, Republic of Ireland. 43 Temple Row, Birmingham B2 5LS, United Kingdom.
T: +353 (0)49 8541477 F: +353 (0)49 8541311 T: +44 (0)845 6801417 F: +44 (0)845 6801419
W: www.floodprecast.ie E: info@floodprecast.ie W: www.floodprecast.co.uk E: info@floodprecast.co.uk
Safe Load Table For Propped Flood Superwideslab®

Precast Screed Total


Slab Depth Depth Depth Super-Imposed Unfactored Live Load kN/m²
(mm) (mm) (mm)
1.5kN/m² 2kN/m² 2.5kN/m² 3kN/m² 3.5kN/m² 4kN/m² 5kN/m² 6kN/m² 7kN/m²
Effective Spans (m)
75 75 150 5.70 5.70 5.70 5.70 5.70 5.70 5.70 5.50 5.20
75 100 175 6.65 6.65 6.65 6.65 6.65 6.65 6.45 6.10 5.80
75 125 200 7.60 7.60 7.60 7.60 7.60 7.40 7.00 6.70 6.40
75 150 225 8.60 8.60 8.40 8.20 8.00 7.90 7.60 7.30 7.05
75 175 250
100 75 175 6.65 6.65 6.65 6.65 6.65 6.65 6.45 6.10 5.80
100 100 200 7.60 7.60 7.60 7.60 7.60 7.40 7.00 6.70 6.40
100 125 225 8.60 8.60 8.40 8.20 8.00 7.90 7.60 7.30 7.05
100 150 250 9.00 9.00 8.80 8.60 8.40 8.20 7.95 7.70 7.45
125 75 200 7.60 7.60 7.60 7.60 7.60 7.40 7.00 6.70 6.40
125 100 225 8.60 8.60 8.40 8.20 8.00 7.90 7.60 7.30 7.05
125 125 250 9.00 9.00 8.80 8.60 8.40 8.20 7.95 7.70 7.45
150 75 225 8.60 8.60 8.40 8.20 8.00 7.90 7.60 7.30 7.05
150 100 250 9.00 9.00 8.80 8.60 8.40 8.20 7.95 7.70 7.45

Safe Load Table For UNPropped Flood Superwideslab®

Precast Screed Total


Slab Depth Depth Depth Super-Imposed Unfactored Live Load kN/m²
(mm) (mm) (mm)
1.5kN/m² 2kN/m² 2.5kN/m² 3kN/m² 3.5kN/m² 4kN/m² 5kN/m² 6kN/m² 7kN/m²
Effective Spans (m)
75 75 150 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60
75 100 175 3.50 3.50 3.50 3.50 3.50 3.50 3.50 3.50 3.50
75 125 200 3.50 3.50 3.50 3.50 3.50 3.50 3.50 3.50 3.50
75 150 225 8.60 8.60 8.40 8.20 8.00 7.90 7.60 7.30 7.05
75 175 250
100 75 175 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20
100 100 200 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20
100 125 225 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00
100 150 250 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00
125 75 200 5.20 5.20 5.20 5.20 5.20 5.20 5.20 5.20 5.20
125 100 225 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
125 125 250 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
150 75 225 6.20 6.20 6.20 6.20 6.20 6.20 6.20 6.20 6.20
150 100 250 6.00 6.00 6.00 6.00 6.00 6.00 6.00 6.00 6.00

Notes

1. Values are obtained from using a maximum 23 No. 9.3mm Strands in our 2.40m Flood Superwideslab and based on ®

25mm cover to the prestressing strands.


2. Limitations of span/depth - 38 for occupancy comfort.
3. The Table shows typically supported effective spans in metres. Where continuity is available over the supports the effective
span can be increased from the values shown (Consult the Flood Precast Technical Office).

4. These values are based on a Flood Superwideslab system which requires structural propping in the temporary condition.
®

5. Spans in excess of 7.5m on Propped Flood Superwideslab table will require a single propline in place prior to erecting
®

slab. Spans in excess of 8m will require 2 lines of propping in place prior to erecting slab. These props should be set to
form minimum camber of 1mm per 1m length of span.
6. Values shown are for guidence. Consult Flood Precast Technical office regarding specific design queries.
01 02
mesh in top of
mesh in top of structural screed
structural screed structural screed structural screed

Tie steel to
engs details
Super Wideslab
Super Wideslab Splice bars across joint
100mm
end bearing

03 04 mesh in top of
structural screed
structural screed
mesh in top of
Job Title: Super Wideslab Job Title: Super Wideslab
structural screed
Drawing Title: Typical joint at adjoining slabs Drawing Title: Typical end
structural screed
Hilltown, Oldcastle, Co. Meath, Republic Of Ireland. Contractor/Client: Flood Precast
Hilltown, Oldcastle, Co. Meath, Republic Of Ireland. Contractor/Client: Flood P
T: +353 (0)49 8541477 F: +353 (0)49 8541311 Scale: 1.10 T: +353 (0)49 8541477 F: +353 (0)49 8541311 Scale: 1.10
W: www.floodprecast.ie E: info@floodprecast.ie Drawing No: 100-01-01 W: www.floodprecast.ie E: info@floodprecast.ie Drawing No: 100-01-02

Super Wideslab

Tie steel to 90mm


engs details end bearing
Super Wideslab
215mm Blockwork
25mm
side bearing

215

Cantilever Steel Job Title: Super Wideslab


05 mesh in top of
structural screed
In Screed 06 tie steel through mesh in top of
Drawing Title: Typical end
structural screed 215mm Inte
beam where required structural screed
Hilltown,
structural Oldcastle, Co. Meath, Republic Of Ireland.
screed Contractor/Client: Flood P
Job Title: Super Wideslab T: +353 (0)49 8541477 F: +353 (0)49 8541311 Scale: 1.10
Drawing Title: Typical side bearing
W:detail
www.floodprecast.ie E: info@floodprecast.ie Drawing No: 100-01-04
Hilltown, Oldcastle, Co. Meath, Republic Of Ireland. Contractor/Client:
varies Flood Precast
T: +353 (0)49 8541477 F: +353 (0)49 8541311 Scale: 1.10
W: www.floodprecast.ie E: info@floodprecast.ie Drawing No: 100-01-03

Super Wideslab Cantilever


Length

Super Wideslab
215mm Blockwork 215mm Blockwork 90mm End Bearing 90mm End Bearing

215

* Props to be in position and


Slimfloor Beam To Engs Design
braced by main contractor
prior to the placing of the slab

07 varies
mesh in top of
structural screed
Job Title: Super Wideslab
Drawing Title: Typical cantilever detail
Structural Screed
Hilltown, Oldcastle, Co. Meath, Republic Of Ireland.
T: +353 (0)49 8541477 F: +353 (0)49 8541311 Scale: 1.10
01. Typical joint at adjoining slabs.
Contractor/Client: Flood Precast Job Title: Super Wide
Drawing Title: Typical
W: www.floodprecast.ie E: info@floodprecast.ie Drawing No: 100-01-05 Slimfloo
varies 02. Typical end
Hilltown, bearing
Oldcastle, detail.
Co. Meath, Republic Of Ireland. Contractor/Client: Floo
T: +353 (0)49 8541477 F: +353 (0)49 8541311 Scale: 1.10
03. Typical side bearingE:detail.
W: www.floodprecast.ie info@floodprecast.ie Drawing No: 100-01-0

Shear Steel
Projecting Links
cast into Slabs
04. Typical end bearing detail 215mm Internal Blockwall.
05. Typical cantilever detail.
06. Typical end bearing detail Slimfloor Beam.
07. Flat Slab Details.

Job Title: Super Wideslab


Drawing Title: Flat Slab Details
Hilltown, Oldcastle, Co. Meath, Republic Of Ireland. Contractor/Client: Flood Precast
T: +353 (0)49 8541477 F: +353 (0)49 8541311 Scale: 1.15
W: www.floodprecast.ie E: info@floodprecast.ie Drawing No: 100-01-07

Building with Confidence


• Flood Superwideslab® is a 2.4m wide prestressed composite flooring solution.

• A
 vailable in depths from 75mm to 175mm and when combined with a structural
topping is an excellent structural flooring solution for spans up to 9.5m.

• W
 et cast onto high quality steel beds and offers an exceptionally high quality
soffit finish which can be left exposed or painted.

• Can be provided with cast-in projecting lattice girder.

• C
 an span in two directions by casting-in reinforcement steel perpendicular
to the prestressing strands making it an excellent solution when catering for
disproportionate collapse design.

floodprecast.ie floodprecast.co.uk
Hilltown, Oldcastle, Co. Meath, Republic of Ireland. 43 Temple Row, Birmingham B2 5LS, United Kingdom.
T: +353 (0)49 8541477 F: +353 (0)49 8541311 T: +44 (0)845 6801417 F: +44 (0)845 6801419
W: www.floodprecast.ie E: info@floodprecast.ie W: www.floodprecast.co.uk E: info@floodprecast.co.uk

You might also like