Inspection Report - Hyundai Forklift
Inspection Report - Hyundai Forklift
CUSTOMER DETAILS:
Company Name: Rastgar Air Compressor
Location: Karachi – Pakistan
EQUIPMENT DETAILS:
Equipment brand/Name: Hyundai Battery Operated Fork lifter
Model # 20B-9F
Serial # HHKHKE000K0000377
Date of Inspection: Inspection on 16.11.2021
OBSERVATIONS:
Observation # 1
Equipment is showing Errors as MF5, SFB, & PFB.
MF5: ‘’The battery voltage does not correspond to SET BATTERY programming’’
SFB: ‘’Master Controller signals that other controllers are in alarm status’’
PFB: ‘’The battery voltage does not correspond to SET BATTERY programming’’
Rectification of Above Errors: Battery Bank is in week condition may be due to not proper charging
and operation so it needs BOOST CHARGING, SERVICE & ELECTROLYTE REPLACEMENT.
Observation # 2
Equipment is showing Error PF0
PF0: Hardware Fault: ‘the mosfets driver are not switched off with watch-dog signal in alarm status’.
Rectification of Above Error: Hydraulic Pump and Control Valve need overhaul, Pump Controller
needs repairing, harness needs repairing, and sensor’s operation (Pump & Temp) troubleshooting
with rectification.
Drive Operation is slow so it needs to be rectified may be due to sensor or drive motor service
required.
Observation # 3
Complete Service required.
Preventive Maintenance with replacement of Consumables and Oil-s.
REMARKS:
Quotation will be submitted for repair and maintenance.
Job will be done at our Workshop.
For
SAZ ENGINEERING PAKISTAN