You are on page 1of 5

D-MET-TEST-PORT Required specifications

S-MET-TEST
Portable accuracy check set for energy meters not ok
Sl. No.

1 GENERAL
1.01 Manufacturer
1.01.1 name
1.01.2 country of manufacturing
1.02 Applicable standards
1.03 Type test
1.03.1 date
1.03.2 in the year
1.03.3 testing laboratory
1.03.3.1 name
1.03.3.2 country
1.04 Applicable type of meters to be calibrated
1.04.1 micro-processor based
1.04.2 electro-mechanical
2 DESIGN DATA

2.01 Measurements

2.02 Auxiliary voltage range


2.03 Voltage input range to Meter
2.04 Current input range to Meter
2.05 Maximum power consumption
2.06 Frequency range
2.07 Power factor
2.08 Applied software is MS Windows based
2.09 Microprocessor resolution (minimum)
2.10 Class of accuracy (minimum)
2.11 Applicable safety standards
2.12 Protection class
2.13 Communication port for data transfer
2.13.1 applicable standards
2.13.1.1 optical port
2.13.1.2 protocol
2.13.2 type
2.14 Display
2.14.1 type
2.14.2 number of digits
2.14.3 dimensions
2.14.3.1 length
2.14.3.2 height
2.14.4 digits
2.14.4.1 height
2.14.4.2 width
2.14.5 colors
2.14.5.1 background
2.14.5.2 digits
2.15 Set is fully automatic
2.16 Set performs in digital logic
2.17 Displays measurement values of
2.17.1 instantaneous voltage
2.17.2 instantaneous current
2.17.3 power factor
2.17.4 missing voltage
2.17.5 missing current
2.17.6 reverse current
2.18 Compatible hardware and software is included
2.19 Number of Meters that the set can store its data
2.20 Central data storage system provided
2.21 Set is equipped with an interface for data transfer
2.22 Barcode reader included
2.23 The set has diagnostic features
2.23.1 for any wrong connections
2.23.2 indication of healthy working
2.23.3 audible alarm in case of inadequate test duration
2.23.4 regular self checks
2.24 The set is provided with all accessories
2.25 Test result displays are tabular and graphical
2.26 Signals are protected against overload /short ccts
2.27 Label printer (for calibration date, etc.)
2.27.1 printer included
2.27.2 stamp in barcode
2.27.2.1 color
2.27.2.2 height
2.27.2.3 width
2.28 Materials
2.28.1 housing frame
2.28.1.1 galvanised mild steel sheet
2.28.1.2 aluminium die-cast alloy
2.28.1.2.1 thickness
2.28.2 portable meter base and cover, terminal block
2.28.2.1 grade
2.28.2.2 UV stability
2.28.2.2.1 applicable standards
2.28.2.3 flame retardant
2.28.2.3.1 applicable standards
2.29 Dimensions
2.29.1 length
2.29.2 width
2.29.3 depth
2.29.4 Weight
3 OTHER PERFORMANCE
3.01 First commercial operation of the equipment
3.02 Reference list attached
4 SUPPORTING DOCUMENTS
4.01 Type test reports enclosed ?
4.02 List of minimum testing facilities enclosed ?
4.03 Technical literature enclosed ?
4.04 Relevant drawing enclosed ?
4.05 Quality assurance plan (QAP) enclosed ?
Required or maximum allowed Manufacturer guarantee/note
0 All data
not complete

0
0
IEC 60736 0
yes 0
dd-mm-yy 0
year 0
0
0
0
0
yes 0
yes 0

active, reactive, apparent power, current,


voltage, power factor, frequency, voltage
sequence indication 0
Vac 86 to 260 0
Vac 30 to 480 0
A 0.01 to 120 0
VA 25 0
Hz 45 to 55 0
0-lag-unity-0-lead 0
yes 0
bit 16 0
0.1 0
IEC 61010 0
IP 68 0

0
IEC 62056-21 0
MODBUS, DNP 0
RS 232 0

LCD with multiple lines 0


No. 6 0

mm 80 0
mm 20 0

mm 6 0
mm 3 0

RAL 9004 0
RAL 9010 0
yes 0
yes 0
yes 0
yes 0
yes 0
yes 0
yes 0
yes 0
yes 0
No. 2000 0
yes 0
yes 0
yes 0

yes 0
yes 0
yes 0
yes 0
yes 0
yes 0
yes 0

yes 0

black/white 0
mm 0
mm 0

0
yes/no 0
yes/no 0
mm 2 0
polyamide 0
6.6 0

ASTM G53/26/23 0
0
IEC 60695-2 / UL 94 V-0 0

mm 0
mm 0
mm 0
kg 0

dd-mm-yy 0
yes/no 0

yes 0
yes 0
yes 0
yes 0
yes 0

You might also like