Information Document 3 Weobley SCH Asbestos Management Survey
Information Document 3 Weobley SCH Asbestos Management Survey
Herefordshire Council
05 June 2023
Type C
Inspection Body
Accredited to
ISO/IEC 17020:2012
1 Executive Summary 4
2 Introduction 10
2.1 General 10
2.2 Scope 10
2.3 Legislation 10
2.4 Asbestos Surveyors 11
2.5 Management Asbestos Survey 11
2.6 Limitations of the Report 11
3 Survey Description 13
3.1 Building description 13
3.2 Areas Not accessed 13
3.3 Sampling Strategy 13
3.4 Presumed materials 14
4 Survey Results 15
4.1 Introduction 15
4.2 Material Risk Assessment 15
4.3 Asbestos Register 16
4.4 Negative Samples Register 17
4.5 Areas Not Accessed Register 17
5 Conclusions 54
5.1 General 54
5.2 Conclusions and Recommendations 54
The scope of the survey included a management asbestos survey to Weobley High
School, Burton Wood, Weobley, Herefordshire HR4 8ST. The layout of the survey
can be seen on the appended plan.
The survey was carried out utilising standard access equipment as stated in our
terms and conditions, unless otherwise agreed. The scope excludes sub-surface
areas and soil contamination.
Full details of all materials, their locations, full MRA scores and management
recommendations can be found within the asbestos register section of the report.
Areas not accessed are also recorded.
In summary, the following materials were identified:
Risk
Material Location Recommendation
Rating
Risk
Material Location Recommendation
Rating
Risk
Material Location Recommendation
Rating
Soffits - Insulating
Low Main Building, 011 Manage
Board
Risk
Material Location Recommendation
Rating
Flange Joint -
Ground Floor, Boiler
Very Low Gaskets Manage
Room, 012
(compressed)
Flange Joint -
Ground Floor, Boiler
Very Low Gaskets Manage
Room, 012
(compressed)
Risk
Material Location Recommendation
Rating
No
Sealed Boxwork 016 Sealed Boxwork
Access
No access due to
No 2nd Floor, Classroom (Maths and Food & Textiles)
risk of excessive
Access 001 Duct/Riser
damage.
Further
investigation
maybe required if
the items are to be
disturbed during
any planned
maintenance or
refurbishment.
Risk
Material Location Recommendation
Rating
Further
investigation
maybe required if
the area is to be
disturbed during
any planned
maintenance or
refurbishment.
2.1 General
Environmental Management Solutions Ltd (EMS), 22A King Street, Hereford, HR4
9DA has carried out a Management Asbestos Survey at Weobley High School,
Burton Wood, Weobley, Herefordshire, HR4 8ST. The survey was undertaken by
Jason Phillips of EMS on the 06 October 2021 to 07 October 2021.
2.2 Scope
The scope of the survey included a management asbestos survey to Weobley High
School, Burton Wood, Weobley, Herefordshire HR4 8ST. The layout of the survey
can be seen on the appended plan.
The survey was carried out utilising standard access equipment as stated in our
terms and conditions, unless otherwise agreed. The scope excludes sub-surface
areas and soil contamination.
2.3 Legislation
CAR2012 requires ‘Duty Holders’ to manage asbestos in their buildings by means
of an asbestos management plan. The first step of this is to locate, identify and risk
assess asbestos containing materials within each non-domestic premises. All
information, including this survey report, should be made available to contractors
working in the property and cascaded down to relevant people including those who
may come into contact with the material.
A management survey has been undertaken in accordance with EMS in-house
procedures and the Health and Safety Executive (HSE) Guidance HSG264
Asbestos: The survey guide. This report will describe the work carried out and
document the results to enable the asbestos risk in the building to be managed in
accordance with the appropriate regulations.
The survey will aim to identify suspect material, confirm by testing and presume by
inspection, those areas of asbestos containing material (ACM). These areas can
then be dealt with in the appropriate manner to prevent contamination of the
building or exposure of subcontractors, employees or members of the public to
unnecessary risk.
Generally, unless stated, a management asbestos survey will not include access
into sealed box work, beneath floorboards or into structural voids and cavities. The
survey should include areas that can be safely accessed without destructive entry
such as above suspended ceiling tiles, into basements and into floor ducts.
• All work carried out in preparing this report has utilised, and is based upon,
EMS’s current professional knowledge and understanding of current relevant
UK standards, codes, technology and legislation. Changes in this legislation
and guidance may occur at any time in the future and cause any conclusions
to become inappropriate or incorrect. EMS does not accept responsibility for
advising Herefordshire Council or other interested parties of the facts or
implications of any such changes.
• It is stressed that while every effort was made to identify the locations and full
extent of all asbestos materials in the specified area, such material may be
located within the structural matrix of the building or in other inaccessible
areas. It should be noted that this survey is not an intrusive level survey and
responsibility cannot be accepted for any materials located beyond the scope
of a management level survey. If asbestos materials have been suspected but
not sampled, this has been highlighted in the report.
several occasions to provide further teaching and student facilities. Many areas
have been refurbished throughout the history of the unit. External asbestos
boarding is present along with modern uPVC capping and windows. Cement
The main school structure is a three storey concrete and steel framed unit with
concrete floor slabs throughout. Floors are covered with asbestos vinyl floor tiles
in many areas; asbestos bitumen remains to the concrete slab where these tiles
Extensive ducts are present on the ground floor; these have insulation board and
thermal insulation debris within, plus cement and composite asbestos products
and associated debris. Heating for the unit is centred from the externally
The areas not accessed during the survey can be found in the ‘No Access’ register
within Section 4.
Samples taken during the survey are detailed on the test certificate in Appendix B.
Each sample, along with a photograph of each sampling point, is included within
the asbestos register in section 4 of this report; positive materials, along with
presumed materials, will be evaluated and risk assessed in accordance with
HSG264.
As defined by the HSE, materials that are strongly presumed look as if they may
contain asbestos, upon visual inspection by an experienced, trained surveyor.
Materials that are presumed to contain asbestos where there is insufficient
evidence to confirm that it is asbestos free, or where a duty holder/surveyor
decides that it is easier under planned management arrangements to presume
certain materials to contain asbestos.
4.1 Introduction
All samples were analysed at our UKAS accredited laboratory in accordance with
our “in house” method of transmitted/polarised light microscopy and centre stop
dispersion staining and the methods outlined in HSG248. The certificates of
analysis are included in appendix B of this report.
For presumed materials the asbestos type must be calculated as Crocidolite until
proved otherwise. In most cases it is unlikely that Crocidolite has been used; but
unless the material risk assessment highlights a medium or high potential for fibre
release it is acceptable to manage the presumed materials on the presumption of
Crocidolite. Further investigation may be required before major maintenance or
demolition.
Some work with Non-Licensed products may require notification to the HSE under
the category Notifiable Non-Licensed Work, again this is task dependant and each
task will require a specific risk assessment.
Along with the MRA scores recommendations have been made for future
management of the materials
These areas have not been risk assessed but a worst case scenario of ‘High Risk’
of fibre release should be applied if these areas are disturbed.
Licensed?
Condition
Quantity
Access.
Product
Surface
Location / Sample ref MRA Comments /
Photograph Asbestos Type
Description /Presumed Score Recommendations
Ground Floor,
Approx. 30 m²
Classrooms
Medium
(Science), 005
2 Very
E-24679/S002 N 1 0 0 Chrysotile 1 Manage
Floor Covering - Low
Bitumen
Ground Floor,
Approx. 40 m²
Classrooms
(Science), 005 E-
Easy
2 Very
24679/PSEMS/ N 1 0 0 Chrysotile 1 Manage
Floor Covering - Low
5181/VS022
Vinyl Floor Tile
Grey tiles
Ground Floor,
Classrooms and
Staff Areas (Main
Building), 010
Medium
1 m²
Strongly Presumed
Ceiling Panels - E-24679/SP Y 2 0 1 6 Low Manage
Asbestos 3
Insulating Board
Within electric
cupboard in room
0/027
Approx. 4 m²
Building), 010
Medium
Presumed Asbestos
Window Panels - E-24679/P N 1 0 1 5 Low Manage
3
Cement
Above door
entrances 0/021
and 0/015.
Ground Floor,
Classrooms and
Staff Areas (Main
Building), 010 N/ N/ N/ Removed
N/A
E-24679/R N N/A 00
A A A
Toilet Cistern -
Composite
Ground Floor,
Classrooms and
Staff Areas (Main
Approx. 400 m²
Building), 010
Medium
E-
Floor Adhesive - 2 Very
24679/PSEMS/ N 1 0 0 Chrysotile 1 Manage
Bitumen Low
5181/008
Throughout all
ground floor
areas below
modern coverings
Approx. 180 m²
Building), 010
Medium
E-
Floor Covering - 2 Very
24679/PSEMS/ N 1 0 0 Chrysotile 1 Manage
Vinyl Floor Tile Low
5181/017
Blue floor tiles
within 021
(Corridor) and
046 (Drama)
Ground Floor,
Classrooms and
Staff Areas (Main
Building), 010
Approx. 50 m²
Medium
Floor Covering - E-
2 Very
Vinyl Floor Tile 24679/PSEMS/ N 1 0 0 Chrysotile 1 Manage
Low
5181/018
Black floor tiles
within 021
(Corridor), 046
(Drama) and 019
(Classroom)
No access was made
within the library at the
Ground Floor,
time of survey due to area
Classrooms and
being locked with no one
Staff Areas (Main
Building), 010 Small Amount with a key available during
Difficult
E- evening/night survey.
Debris to Pipe - 24679/PSEMS/ Y 3 3 3 Chrysotile 1 10 High
Further investigation is
Thermal 5181/021
recommended to inspect
Insulation
the extent of
Within ceiling old contamination within the
of 0/032 (Library) ceiling void.
Remove
Medium
E-
20 m²
2 Very
Floor Covering - 24679/PSEMS/ N 1 0 0 Chrysotile 1 Manage
Low
Vinyl Floor Tile 5181/022
Grey floor tiles
within 0/029 and
0/041
Ground Floor,
Classrooms and
Staff Areas (Main
Medium
Building), 010 E-
4 m²
24679/PSEMS/ Y 2 0 1 Amosite, Chrysotile 2 5 Low Manage
Ceiling Panels -
5181/025
Insulating Board
Within 0/021
(Corridor)
Ground Floor,
Classrooms and Small amounts of cement
Staff Areas (Main debris are present to the
Medium
Building), 010 E-
1 lin m
Chrysotile, 7 ceiling below the flue.
24679/PSEMS/ N 1 2 1 Removal of the flue and
Redundant Pipe - Crocidolite 3 Medium
5181/029 debris is reccomended.
Cement
Within 0/007 Manage
(Staff room)
Ground Floor,
Classrooms and
Approx. 6 m²
Building), 010 E-
3 Very
24679/PSEMS/ N 1 1 0 Chrysotile 1 Manage
Floor Covering - Low
5181/147
Vinyl Floor Tile
Blue tiles in 0/057
store cupboard
Approx. 6 m²
Building), 010
Medium
E-
3 Very
Floor Covering - 24679/PSEMS/ N 1 1 0 Chrysotile 1 Manage
Low
Vinyl Floor Tile 5181/148
Black tiles in
0/057 store
cupboard
Ground Floor,
Classrooms and
Staff Areas (Main
Approx. 55 m²
Building), 010
E-
Easy
3 Very
Floor Covering - 24679/PSEMS/ N 1 1 0 Chrysotile 1 Manage
Low
Vinyl Floor Tile 5181/149
Blue tiles in
rooms 0/065 and
0/075
Ground Floor,
Classrooms and
Staff Areas (Main
Building), 010
Approx.16 m²
Medium
Adhesive to E-
3 Very
Ceiling Void - 24679/PSEMS/ N 1 1 0 Chrysotile 1 Manage
Low
Bitumen 5181/150
Adhesive to
ceiling void of
rooms 0/065 and
0/058
Easy
8 m²
2 Very
Floor Covering - 24679/PSEMS/ N 1 0 0 Chrysotile 1 Manage
Low
Vinyl Floor Tile 5181/206
Grey tiles in store
cupboard next to
staff room 0/006
Throughout
Annex, 012 contain asbestos and must
Difficult
Presumed Asbestos be presumed throughout.
Subfloor Ducts - E-24679/P Y 3 3 1 10 High
3 Ducts remain sealed in
Thermal
Insulation 2023.
Manage
Easy
E-24679/PSE- 7 However it must be noted
Insulation Y 3 0 2 Amosite, Chrysotile 2
15160/003 Medium that traces of fibres may
Thermal remain and encapsulated
insulation walls should continue to
residues to wall be managed in line with
the CAR2012.
Manage and Label
Small Quantity
Removed
Bolt - Thermal Material has been
E-24679/PSE- N/ N/ N/
N/A
Insulation Y N/A 00 successfully removed in
15160/005 A A A
Thermal 2023. Paperwork should
insulation be filed accordingly.
residues to bolt of
beam
Ground Floor,
N/A
Y N/A 00 removed in April 2023.
Board 15160/006 A A A
Paperwork should be filed
Debris to nail accordingly.
holes of timber
batons
Walls have been scraped,
all loose debris has been
Easy
Wall - Thermal E-24679/PSE- 7 However it must be noted
Y 3 0 2 Amosite, Chrysotile 2
Insulation 15160/007 Medium that traces of fibres may
Thermal remain and encapsulated
insulation walls should continue to
residues to wall be managed in line with
the CAR2012.
Manage and Label
Small Quantity
Removed
Pipe - Thermal
Insulation E-24679/PSE- N/ N/ N/ Joint has been cleaned in
N/A
Y N/A 00 April 2023. Paperwork
15160/008 A A A
Debris to joint should be filed
where lagging accordingly.
changes from
hardset to glass
fibre
Walls have been scraped,
Ground Floor, all loose debris has been
leaking pipe
Wall - Thermal
Insulation with encapsulation paint.
Easy
E-24679/PSE- 7 However it must be noted
Y 3 0 2 Amosite, Chrysotile 2
Thermal 15160/011 Medium that traces of fibres may
insulation remain and encapsulated
residues to wall. walls should continue to
Some be managed in line with
unencapsulated the CAR2012.
residues present.
Manage and Label
Ground Floor,
Throughout Area
Boiler Room
(Leak Area), 012 Removed
N/ N/ N/
N/A
E-24679/R Y N/A 00
Floor - Thermal A A A
Insulation
Small Amount
Boiler Room, 012 qualified operatives
holding task specific and
Easy
Flange Joint - E-24679/PSE- 4 Very
N 2 0 1 Chrysotile 1 appropriate asbestos
Gaskets 15610/002 Low
(compressed) awareness training should
undertake work on flange
joints on this site.
Manage
Walls have been scraped,
all loose debris has been
Easy
Insulation E-24679/PSE- 7 However it must be noted
Y 3 0 2 Amosite, Chrysotile 2
15610/004 Medium that traces of fibres may
Thermal
insulation remain and encapsulated
residues to wall walls should continue to
behind pipes be managed in line with
the CAR2012.
Manage and Label
Walls have been scraped,
Ground Floor, all loose debris has been
Ground Floor,
Small Amount
Boiler Room, 012 All gaskets on site should
Medium
E- be treated as asbestos
Flange Joint - 4 Very
24679/PSEMS/ N 2 0 1 Chrysotile 1 containing.
Gaskets Low
5181/131
(compressed) Manage
Ground Floor,
Boiler Room, 012 Removed
N/ N/ N/
N/A
E-24679/R N N/A 00
Debris - Cement A A A
Ground Floor,
Boiler Room, 012
E- Removed
N/ N/ N/
N/A
Debris - 24679/PSEMS/ Y N/A 00
A A A
Insulating Board 5181/136
Material previously
Ground Floor, Small Amount identifed and presumed to
Floor Ducts, 013 remain in situ.
E- Difficult 3 Very
Debris - Vinyl 24679/PSEMS/ N 1 1 0 Chrysotile 1 An environmental clean
Low
Floor Tile 5181/102 throughout the ducts is
recommended.
Manage
Material previously
Ground Floor, identifed and presumed to
Throughout
Floor Ducts, 013 remain in situ.
Difficult
E-
Debris - Thermal 24679/PSEMS/ Y 3 3 3 Chrysotile 1 10 High An environmental clean
Insulation 5181/103 throughout the ducts is
recommended.
Manage
Material previously
Ground Floor,
identifed and presumed to
Floor Ducts, 013
Throughout
remain in situ.
Difficult
E-
Pipe Residue -
24679/PSEMS/ Y 3 3 3 Chrysotile 1 10 High An environmental clean
Thermal
5181/104 throughout the ducts is
Insulation
recommended.
Manage
Material previously
Ground Floor,
identifed and presumed to
Small Amount
Floor Ducts, 013
remain in situ.
Difficult
E-
Debris and
24679/PSEMS/ N 1 3 1 Chrysotile 1 6 Low An environmental clean
Packers -
5181/105 throughout the ducts is
Cement
recommended.
Manage
Material previously
Ground Floor, identifed and presumed to
Small Amount
Floor Ducts, 013 remain in situ.
Difficult
E-
4 Very
Felt Debris - 24679/PSEMS/ N 1 2 0 Chrysotile 1 An environmental clean
Low
Bitumen felt 5181/116 throughout the ducts is
recommended.
Manage
Material previously
Ground Floor, identifed and presumed to
Throughout
Floor Ducts, 013 remain in situ.
Difficult
E-
Debris - Thermal 24679/PSEMS/ Y 3 3 3 Chrysotile 1 10 High An environmental clean
Insulation 5181/119 throughout the ducts is
recommended.
Manage
Material previously
Ground Floor, identifed and presumed to
Throughout
Floor Ducts, 013 remain in situ.
Difficult
E-
Debris - Thermal 24679/PSEMS/ Y 3 3 3 Amosite 2 11 High An environmental clean
Insulation 5181/121 throughout the ducts is
recommended.
Manage
Material previously
Ground Floor, identifed and presumed to
Throughout
Floor Ducts, 013 remain in situ.
E- Difficult
Debris - Thermal 24679/PSEMS/ Y 3 3 3 Amosite, Chrysotile 2 11 High An environmental clean
Insulation 5181/123 throughout the ducts is
recommended.
Manage
Small Amount
Floor Ducts, 013
remain in situ.
Difficult
E-
Pipework - 4 Very
24679/PSEMS/ N 2 0 1 Chrysotile 1 An environmental clean
Gaskets Low
5181/127 throughout the ducts is
(compressed)
recommended.
Manage
1st Floor,
Approx. 200 m²
Classrooms
(English), 002
Medium
E-
2 Very
Floor Adhesive - 24679/PSEMS/ N 1 0 0 Chrysotile 1 Manage
Low
Bitumen 5181/008
Presumed
throughout
1st Floor,
Classrooms
Approx. 180 m²
(English), 002
Below modern floor
Medium
E-
Floor Covering - 3 Very coverings
24679/PSEMS/ N 1 1 0 Chrysotile 1
Vinyl Floor Tile Low
5181/012 Manage
Within 1A/002,
1A/006 and
1A/007
1st Floor,
Classrooms
(English), 002
Wall Panels - N/A N/ N/ N/ Removed
E-24679/R N N/A 00
Insulating Board A A A
Behind
blackboards in
1A/003
Approx. 40 lin m
(English), 002
Presumed to remain in situ
Medium
Window Sills - E-
4 Very below modern sills
Cement 24679/PSVSE N 1 1 1 Chrysotile 1
Low
MS/5181/005 Manage
Within 1A/003,
1A/002, 1A/006,
1A/007, 1A/010
and 1A/012
1st Floor,
Classrooms
Approx. 45 m²
(Music), 003
Medium
E-
2 Very
Floor Adhesive - 24679/PSEMS/ N 1 0 0 Chrysotile 1 Manage
Low
Bitumen 5181/008
Presumed
throughout
1st Floor,
Classrooms
Approx. 90 m²
(Language), 004
Medium
E- Below carpet
2 Very
Floor Adhesive - 24679/PSEMS/ N 1 0 0 Chrysotile 1
Low Manage
Bitumen 5181/008
Presumed
throughout
Approx. 40 lin m
& Textiles), 001
Window Sills - E-
Easy
4 Very
Cement 24679/PSEMS/ N 1 1 1 Chrysotile 1 Manage
Low
5181/005
Within rooms
2/004, 2/003,
2/008, 2/010 and
cleaning
cupboard
2nd Floor,
Classroom
Approx. 200 m²
(Maths and Food
Medium
& Textiles), 001 E-
3 Very
24679/PSEMS/ N 1 1 0 Chrysotile 1 Manage
Floor Covering - Low
5181/008
Bitumen
Adhesive to floor
throughout
2nd Floor,
Classroom
(Maths and Food
Approx. 80 m²
& Textiles), 001
E-
Easy
3 Very
Grey Floor 24679/PSEMS/ N 1 1 0 Chrysotile 1 Manage
Low
Covering in 5181/011
Room 2/002 -
Vinyl Floor Tile
Easy
3 m²
3 Very
24679/PSEMS/ N 1 1 0 Chrysotile 1 Manage
Floor Covering - Low
5181/203
Vinyl Floor Tile
Within cleaners
cupboard 2/007
2nd Floor,
Classroom
(Maths and Food
& Textiles), 001
E-
Easy
6 m²
3 Very
Grey Floor 24679/PSEMS/ N 1 1 0 Chrysotile 1 Manage
Low
Covering - Vinyl 5181/204
Floor Tile
Within store
2/009
Main Building,
011
Medium
E-
3 m²
Canopy and Soffit 24679/PSEMS/ Y 2 0 1 Amosite, Chrysotile 2 5 Low Manage
- Insulating Board 5181/141
To 0/059
Approx. 10 Lin m
Main Building,
011 Medium
E-
Canopy and Soffit 24679/PSEMS/ Y 2 1 1 Amosite, Chrysotile 2 6 Low Manage
- Insulating Board 5181/143
To 0/005
Approx. 30 lin m
Soffits - Insulating
Board
Medium
E-
Outside rooms 24679/PSVSE Y 2 1 1 Amosite, Chrysotile 2 6 Low Manage
0/017, 0/020, MS/5181/143
0/046 and all high
level first and
second floor soffit
boards.
Ground Floor,
Classrooms (Science)
005 E-24679/S003 No Asbestos Detected in Sample
Ground Floor,
Classrooms (Science)
005 E-24679/S004 No Asbestos Detected in Sample
Ceiling Void - Insulating
Board
Ground Floor,
Classrooms (Science) E-
005 24679/PSEMS/51 No Asbestos Detected in Sample
Beam Cladding - 81/023
Insulating Board
Ground Floor,
Classrooms (Science E-
Area) 005 24679/PSEMS/51 No Asbestos Detected in Sample
Floor Covering - Linoleum 81/024
Floor Covering
Ground Floor,
Classrooms (Science E-
Area) 005 24679/PSEMS/51 No Asbestos Detected in Sample
81/LIB001
Adhesive - Bitumen
Ground Floor,
Classrooms (Science E-
Area) 005 24679/PSEMS/51 No Asbestos Detected in Sample
81/LIB002
Adhesive - Bitumen
Ground Floor,
Classrooms (Science E-
Area) 005 24679/PSEMS/51 No Asbestos Detected in Sample
Pipework Debris - 81/LIB003
Thermal Insulation
Ground Floor,
Classrooms and Staff
Areas (Main Building) 010 E-24679/S005 No Asbestos Detected in Sample
Ground Floor,
Classrooms and Staff
Areas (Main Building) 010 E-24679/S006 No Asbestos Detected in Sample
Floor Covering - Linoleum
Floor Covering
Ground Floor,
Classrooms and Staff E-
Areas (Main Building) 010 24679/PSEMS/51 No Asbestos Detected in Sample
Ceiling Panel - Insulating 81/026
Board
Ground Floor,
Classrooms and Staff E-
Areas (Main Building) 010 24679/PSEMS/51 No Asbestos Detected in Sample
Engineering Flooring - 81/027
Vinyl Floor Tile
Ground Floor,
Classrooms and Staff E-
Areas (Main Building) 010 24679/PSEMS/51 No Asbestos Detected in Sample
81/028
Sink Pad - Composite
Ground Floor,
Classrooms and Staff E-
Areas (Main Building) 010 24679/PSEMS/51 No Asbestos Detected in Sample
81/030
Sink Pad - Composite
Ground Floor,
Classrooms and Staff E-
Areas (Main Building) 010 24679/PSEMS/51 No Asbestos Detected in Sample
Floor Covering - Linoleum 81/145
Floor Covering
Ground Floor,
Classrooms and Staff E-
Areas (Main Building) 010 24679/PSEMS/51 No Asbestos Detected in Sample
81/146
Stair Nosing - Composite
Ground Floor,
Classrooms and Staff E-
Areas (Main Building) 010 24679/PSVSEMS/ No Asbestos Detected in Sample
Stanchion Cladding - 5181/023
Insulating Board
Portacabin 2 (Geography
and History) 007
E-24679/VS007 No Asbestos Detected in Sample
External Render -
Textured Coating
Portacabin 4 (Storage)
015
E-24679/VS007 No Asbestos Detected in Sample
External Render -
Textured Coating
2nd Floor, Classroom (Maths and Food & Textiles) 001 No access due to risk of excessive damage.
Duct/Riser - No Access Gained
Services were live at the time of survey; there was no access in live
equipment including electrical switchgear, heaters, boilers, extraction
Throughout, Services 017 equipment or any other powered units
Services and Powered Equipment - No Access Gained Further investigation maybe required if the items are to be disturbed
during any planned maintenance or refurbishment.
High Level Roof Areas - No Access Gained Further investigation maybe required if the area is to be disturbed
during any planned maintenance or refurbishment.
5.1 General
During the survey asbestos materials have been identified on the site. Any
identified materials and associated material risk assessment are detailed in the
tables in Section 4 of this report. In addition, any no accessed areas are recorded
in the relevant table.
Under CAR 2012, there is a legal duty to manage asbestos within any non-
domestic premises. The survey is the first stage of that process but is not enough
to comply with the regulations.
Any materials identified within the survey will require regular monitoring as a
minimum level of management. All site procedures, re-inspections and priority
ratings should be included in the Asbestos Management Plan (AMP) for the site.
The AMP must include a procedure for controlling maintenance and/or
refurbishment works. Areas not accessed as part of this survey must be considered
as part of the AMP.
Any work on or adjacent to asbestos containing materials will require a specific risk
assessment and this will determine if notification to the HSE or a licensed
contractor is required.