You are on page 1of 14

33.4 33.

4
3.2 3.21
Parameters & Dimensions

C 1 Size = 24 X 8
C 2 Size = 24 X 8

C1.Dead Load(PD) = 33.4 kips


C1.Live Load (PL) = 3.2 kips

C2.Dead Load = 33.4 kips


C2. Live Load = 3.21 kips 1' 3
7
qa(allowable soil pressure) 2 ksf

c/c distance between columns = 7'


Left distance from C1 = 1' 8 C1 C2 8

f'c = 3 ksi
fy = 60 ksi

24 24
1) Location of the resultant of the column loads : 11

Take moment about the center of the exterior columns 1 :

x = 3.50'

Distane of the resultant from the left edge = 4.50'

Length of the footing = 11.00'

2)Area of the footing :

h (Footing Depth) = 18 inches


Cover = 2.5 inches

d = 15.5 inches

Total actual (working load ) = 73.21 kips

Net upward pressure = 1775 ksf

Required Area = 41.2 ft2

b ( Width of footing ) = 5 ft
Footing Size 11' X 5' Area = 55 ft2

52.2 Resultant(.R)52.217
3) Ultimate upward pressure :

Pu1 ( C1) 52.2 kips


Pu2 ( C2) 52.217 kips

qu = 1.90 ksf

4) Factored shear force: qu = 1.90

Upward pressure = 9.5 4

Resultant(.R)

C1 C2

14.24 kips

0.00
kips

33.216741 kips 18.99 kips

3' 2'

91.3391 kft
0.00 19.00141 kft
kft

Vu (outer face of column 1 ) = 0.00 kips

Vu (inner face of column 1) = 33.22 kips

Vu (outer face of column 2 ) = 18.99 kips

Vu (inner face of column 2) = 14.24 kips

Point of zero shear (x) :

.= 5 ft

x = 3.50 ft

5) Factored moment :

Mu1(Outer face of C1) = 0.0 kft

Mu1(Outer face of C2) = 19.00 kft

Max. moment occurs at zero shear

Max.Mu1 (calculated from column 1 ) = 91.34 kft

Max.Mu1 (calculated from column 2 ) = -13.07 kft


6) Checing of depth for one-way shear :

At a distane d = 15.5 from the interior face of C2

Vu = 1.98 kips

d = 0.35 < d(effective depth) 15.5

No Need of shear r/f

7) Checking of depth for two-way shear(punching shear):

bo = 13.166667 ft

c+d = 3.2916667 ft

Shear at a section d/2 from all sides of the column

Vu = Pu2 - qu(c+d)2 = 31.65 kips

d = 1.08 < d(effective depth) 15.5

Not Critical

8) Reinforcement in the long direction : (Top R/f)

Bar # to use 8
cover

Mu (max)= 91.34 kft

Ru = 76.04

Rho = 0.0014322

Use Minimum steel ratio 0.005 0.005


Rho(min) = 0.0033333

As = 4.65 0.93 10.129032 6.92356688

Use 7 # 8 bars As = 5.435

Spacing of bars = 10 inches

Reinforcement in the long direction : (Bottom R/f)

Bar # to use 6

Minimum shrinkage r/f = 6.72 0.610856 8.67430304 7.916982

Use 8 # 6 bars As = 3.50

Development length required for the main top bars = 1.4ld = 35 inches
beyond the point of maximum moment

7 # 8

8 # 6
9) Reinforcement in the short direction :
11'

C1 C2

5'

Bandwidth 1 Bandwidth 2

5' 4.6'

Reinforcement under the C1 :

Bandwidth = c + 2d = 55 .= 5'

Net Upward pressure in the short direction under C1 :

Pu1 = 10.44 ksf


width of footing

Distance from the free end to the face of the column = 1.500 ft

Bar # to use 8

Mu(at face of the C1) = 11.75 kft

Ru = 10.666

Rho = 0.000198 < Rho(min) Rho(min) governs 0.002


Rho(min) = 0.002

As = 1.705 0.372 15.420983 4.56656896

Use 5 # 8 bars As = 3.585 in2

Reinforcement under the C2 :

Bandwidth = c + 2d = 55 " .= 4.6 ft

Net Upward pressure = Pu2 = 10.44 ksf


width of footing

Distance to face of column = 1.500 ft

Bar # to use 8

Mu(at face of the C2) = 11.75 kft

Ru = 10.67

Rho = 0.000198 > Rho(min) Rho(min) governs 0.002

Rho(min) = 0.002

As = 1.98 in2 #VALUE! #VALUE!

Use #VALUE! # 8 bars As = #VALUE!

Bandwidth 1 Bandwidth 2
5 # 8 #VALUE! # 8

8 # 6
-3.999044
0.00

2.001

1.50

91.3391
24

1 1
2 2

# Area 3 2
Max Mu = 91.3391 4 3
3 0.11 5 4
4 0.20 6 5
m 23.529 5 0.31 7 5
F 1147.5 6 0.44 8 6
7 0.60 9 7
8 0.79 10 8
9 0.99 11 9
12 9
0.79 13 10
5.65 14 11
15 12
16 13

0.44 1 0
2 1
7.72 3 1
4 2
5 2
6 3
4 7 3
8 4
9 4
10 4
11 5
12 5
13 6
14 6
15 7
16 7
0.785 1 0.79
2 1.57
3 2.36
4 3.14
5 3.93
6 4.71
7 5.50
8 6.28
9 7.07
10 7.85
11 8.64
12 9.42
13 10.21
2.705 14 10.99
15 11.78
16 12.56
2.705