Professional Documents
Culture Documents
Module 5 Philippine Constitution
Module 5 Philippine Constitution
CONSTITUTION
JIMSY F. MACAWILE TREY
research
LAST LESSON MODULE 4SUMMARY
• DTI (MINISTRY ORDER NO. 39 SALIENT POINT
• RESA LAW (RA 9646) SALIENT POINT
TREY
research
What PD 957 covers
• Subdivisions
• Condominiu
ms
TREY
research
What PD 957 covers
• M e d i u m cost
housing
• Open market
housing
TREY
research
SUBDIVISIONS
TREY
research
Saleable vs. non-saleable
• 70% saleable
• 30% non-
saleable
TREY
research
What are non-saleableareas?
• Parks a n d
playgrounds
• Community
facilities
• Circulation system
TREY
research
Parks and playgrounds
• Required for projects 1 ha. or
mor e
• 3.5% m i n i m u m (20 lots / ha.)
• 9.0% m a x i m u m (65 lots / ha.)
• BUT n o t less t h a n 100 sqm.
TREY
research
Parks and playgrounds
TREY
research
Community facilities
• Multi-purpose center required for
projects 1 hectare or bigger
• These areas are non-saleable
TREY
research
TREY
research
Hierarchy of roads
TREY
research
RROW widths
TREY
research
RROW widths
• Major road: 10.0m m i n i m u m
• Minor road: 8.0m m i n i m u m
• Applies to b o t h m e d i u m cost a n d
open m a r k e t
TREY
research
Planting strips and sidewalks
TREY
research
Planting strips and sidewalks
Plantin
RROW Carriageway Sidewalk
g
strip
10.0m 8.0 m 1.2 m 0.8 m
TREY
research
Minimum lot areas
Medium cost Open market
TREY
research
Minimum lot frontages
Medium cost Open market
Single d e t a c h e d
Corner lot 12.0 m 12.0 m
Regular lot 10.0 m 10.0 m
Interior lot 3.0 m 3.0 m
Duplex 8.0 m 8.0 m
Rowhouse 4.0 m 4.0 m
TREY
research
Minimum lot: single detached
TREY
research
Minimum lot: duplex
TREY
research
Minimum lot: rowhouse
TREY
research
Block length
TREY
research
Block length
TREY
research
Rowhouse clusters
20
units
Minimum floor areas
• M e d i u m cost = 30
sqm.
• Economic = 42 sqm.
TREY
research
Setbacks
• Follow
NBC.
TREY
research
CONDOMINIUMS
TREY
research
Minimum sizes of rooms
• Follow
NBC.
Min. area Min. dimension
Room for 6.00sqm 2.00m
human
habitation
Kitchen 3.00sqm 1.50m
Toilet a n d b a t h 1.20sqm 0.90m
TREY
research
Parks and playgrounds
• Required if:
– 10 condo units or more
– Project is 1,000 sqm. or larger
• M a y b e w a i v e d if a public p a r k is
within 800m
TREY
research
Parks and playgrounds
• 50 sqm. for 10 condo units
• +3 sqm. for ever y additional
unit
TREY
research
Parking
• Follow NBC:
– Units w i t h a floor area of 18 sqm. –22
sqm. : O n e slot for every 8 units
TREY
research
Off-site parking
• OK if located 2 0 0 m w a y or less
from commercial condo.
• OK if located 100m w a y or less
from residential condo.
TREY
research
Roads
• M i n i m u m RROW: 8.00m
– 6.00m for carriageway
– 2.00m for sidewalk/planting
strip
• For hierarchy or roads,
follow requirements for
subdivisions
TREY
research
Floor areas for condominiums
• Single occupancy
– 18 sqm.
– 12 sqm. for students
• Family occupancy
– 22 sqm. for m e d i u m
cost
– 36 sqm. for m e d i u m
cost
TREY
research
TREY
research
TREY
research
TREY
research
TREY
research
TREY
research
TREY
research
TREY
research
TREY
research
Housing &
Subdivision
Development
Laws Governing the Type of Development and Licensing
of Subdivision Projects
Definition of Terms:
• Subdivision in General- is a tract of land parcelized into two or more lots.
• Subdivision Project - as defined in PD 957 is a tract of land registered under Act 496 which is partitioned primarily
for residential purposes into individual lots with ot without improvements thereon, and offered for sale to the
public in cash or installment. It shall include all residential, commercial and recreational areas, as well as open
spaces and other community and public areas in the project.
TREY
research
• Simple subdivision - a subdivision without any street or open space
• Complex subdivision- a subdivision with resulting streets and open space.
• Square Planning - a subdivision scheme for flat or relatively flat terrain.
• Gridiron - a subdivision scheme where the resulting blocks are rectangular in
shape.
• Chaplan - is an indention along corner corner lots to allow better visibility to
perpendicular traffic.
TREY
research
• Cul-de-sac - a passageway with only one outlet
Key Lot - is a lot adjoining a corner lot, at right angle to it, and fronting an intersection
street.
• Relocation Survey - is the measurement of the entire mass of land to determine
its external boundaries and ascertain whether or there are encroachments.
• Subdivision Survey - is a survey determine the boundaries of each lot in a
subdivision.
• Contour Line - refers to the line in a topographic map to indicate the elevation of
the land at various points.
• Tie Line - refers to the line connecting point 1 of a lot of reference point, such as
BLLM.
TREY
research
BP 220 – an Act to establish and promulgate different levels
of Standards for Economic and Socialized Housing Projects.
Socialized Housing
Refers to housing programs and projects covering houses and
lots of home lots only undertaken by the government or the
private sector for the underprivileged and homeless citizens.
Economic Housing
BP 220 – a type of housing project provided to average income
families.
R.A. 7279 (UDHA) - refers to a type of housing project with
lower interest rates and longer amortization periods provided
to moderately low income families as defined under existing
laws, rules and regulations
TREY
research
PD 957 – OPEN MARKET
No Price ceiling
TREY
research
Technical Guidelines and Standards for Subdivision
1. Availability of basic needs
2. Conformity with the Zoning Ordinance or Land use Plan of the
City/Municipality.
3. Physical suitability
TREY
research
Easements
Subdivision projects shall observe and conform to the
provisions of easements as may be required by:
1. Water Code of the Philippines on water bodies
2. National Power Corporation(NPC) on transmission lines.
3. Fault traces as identified by PHILVOCS
4. Right-of-way of other public companies.
5. Loading and unloading for projects abutting national
roads.
TREY
research
Transmission Lines
TREY
research
Memorial Parks / Cemeteries
Minimum easement of 25 meters shall be provided
Land Allocation
There shall be no fixed ratio between the saleable portion and
non – saleable portion of a subdivision project.
Definition of Terms
Open space - shall refer to areas allocated for the following:
1. Circulation
2. Community Facilities
3. Parks and Playground
4. Easements
5. Courts
Parks/Playground - that portion of the subdivision which is
generally not built on and intended for passive or active
recreation.
Community Facilities – facilities or structures intended to
serve common need and for the benefit of the community, such as
neighborhood/multi-purpose center, drugstore, school,
livelihood center and the like.
TREY
research
Parks and Playgrounds Allocation
Economic Housing
Density (no. of lots/DU per Hectare) Allocation (% of gross area for PP)
107-120 4%
121-130 5%
131-140 6%
141-150 7%
Above 150 9%
TREY
research
Socialized Housing
Density (no. of lots/DU per Hectare) Allocation (% gross are for PP)
• 151-160 • 4%
• 160-175 • 5%
• 176-200 • 6%
• 201-225 • 7%
• Above 225 • 9%
Density and Allocation for Socialized Housing are same with Economic
Housing . An addition of 1% increment for every 10 or fraction thereof
above 225.
TREY
research
Community Facility
Allocation
Economic Housing Socialized Housing
TREY
research
Hierarchy of Roads
PROJECT SIZE ECONOMIC HOUSING SOCIALIZED HOUSING
2.5 has and below Major, minor, motor, court, Major, minor, motor, court,
alley pathwalk
Above 2.5-5 -do- -do-
TREY
research
PROJECT SIZE (has) RIGHT OF WAY (m)
TREY
research
Width of Planting Strips and Sidewalks
a) Single detached 72 64
b) Duplex/single attached 54 48
c) Row Houses 36 28
TREY
research
MINIMUM LOT FRONTAGE
Type of Housing ECONOMIC HOUSING SOCIALIZED HOUSING
Lot
1) Single detached
a. Corner Lot - 8m 8m
b. Regular Lot - 8m 8m
c. Irregular Lot - 4m 4m
d. Interior Lot – 3m 3m
2) Duplex/Single Attached 6m 6m
3) Row House 4m 3.5 m
TREY
research
• Shell House – a habitable dwelling unit which meets minimum
requirements for a housing core with the following additional
components being includes as part hereof:
1. All exterior walls to enclose the unit
2. Openings for doors and windows
3. Plumbing fixtures
4. Electrical wiring within the unit
5. Floor
TREY
research
House Requirements
Minimum Level of
Completion
TREY
research
Licensed and Registered Professionals for Subdivision Plan
TREY
research
• Required Minimum level of development before the issuance of License of Sell for
Subdivision projects:
TREY
research
Parking Requirements
• One (1) parking slot per eight (8) living units
• Average Dimension – 2.5 meters x 5.0 meters for perpendicular or diagonal
parking 2.15 meters x 6.0 meters for parallel parking
Parking Dimensions
• Perpendicular or diagonal parking • 2.5 m x 5.0 m
• Parallel parking • 2.15 m x 6.0 m
TREY
research
PD 957 The Subdivision and Condominium Buyer’s Protective Decree
Density (no. of lots/DU per hectare Allocation (% of gross area for PP)
21-25 4%
26-35 5%
36-50 6%
51-65 7%
Above 65 9%
TREY
research
Automatic fire alarm suppression system should be provided for structure more than
15 meters in height.
Elevator Requirements
• Provision for elevators shall be required for buildings 6 storeys and beyond
Minimum Floor Area of Living Units
TREY
research
table
• In no case shall the number of row houses exceeds 20 units per block/cluster and or
beyond 100 meters in length.
TREY
research
P.D. 957 Design Standards and Guidelines for Residential
Condominium Projects
A. Site Criteria
B. Planning Consideration
C. Design Parameters
A. Site Criteria Shall conform to
• Comprehensive
• Zoning Ordinance
• National Building Code
TREY
research
B. Planning Consideration
• Supplementary and supportive activities to residential use shall be
allowed
• Open Spaces shall be provided within the Project site pursuant to the
National Building Code
• Easements for utilities shall be integrated with land circulation
system
• Building orientation on lot shall take into account proper ventilation,
sunlight and land characteristics
• No development shall be allowed within the 5-meter mandatory
easement on both sides of the Marikina Valley Fault trace and such
other fault traces as nay be identified by PHILVOCS
TREY
research
C. Design Parameters
• Parks & Playground shall be required for:
Project with a gross saleable area of 1,000 square meters, OR
Projects with ten (10) or more condominium units. Except when the
condominium is part of a subdivision project OR not more than 800 meters
from a publicly accessible park / playground
Parking Space Requirements
• Residential Condominium Units
• Parking slot requirement shall be in accordance with the National Building Code
• Off-site parking may be allowed in addition to the on-site parking provided that the
designated parking area is part of the project
• Compliance with additional parking spaces as required by local ordinance shall be
mandatory
• Commercial Condominium Units
• Parking slot requirement shall be in accordance with the National Building Code
• Off-site parking may be allowed in addition to the on-site parking provided that the
designated parking area is part of the project OR the project is within the commercial
subdivision where common parking is part of the approved subdivision plan and that
parking arrangements are explicitly indicated in the contract of sale of property to be
developed
• Off-site parking shall not be located 200 meters from condominium project
TREY
research
Basic Facilities and Services
Service Area
Adequate laundry and drying areas shall be provided
Where such service areas are held in common, they shall have suitable
outdoor locations, fenced or screened and kept away from living rooms,
entrance or front yards.
Mechanical Equipment
Provision of elevators shall conform to the plans and specifications of
the duly licensed architect/engineer Shall be in accordance with the
National Building Code, the Accessibility Law, national industry
standards and other pertinent laws.
Refuse Collection/Disposal
Centralized garbage depository area and efficient refuse collection and
disposal services shall be provided it shall conform to the provision of
the sanitation Code of the Philippines.
TREY
research
Floor Area Requirements
Single - Occupancy Unit
Minimum floor area shall be 18 square meters
TREY
research
TREY
research
TREY
research
TREY
research
TREY
research
Add a footer TREY
research
119
Add a footer TREY
research
120
Add a footer TREY
research
121
MODULE 4SUMMARY
• DTI (MINISTRY ORDER NO. 39 SALIENT POINT
• RESA LAW (RA 9646) SALIENT POINT