100-Mc-415-Ra3 - 0 Calculation Memory Receiver Tank
100-Mc-415-Ra3 - 0 Calculation Memory Receiver Tank
: 100-MC-415-RA3
RECEIVING TANK Review: 0
Page 1 of 12
CALCULATION MEMORY Doc. No.: 100-MC-415-RA3
RECEIVING TANK
Review: 0
Section
Front page................................ 1
Index..................................... 2
Data Sheet................................ 3
Design Data............................... 4
Shell Design.............................. 5
Bottom Head............................... 6
Top Head…................................. 7
Static Loads.............................. 8
Support Lugs.............................. 9
Page 2 of 12
CALCULATION MEMORY Doc. No.: 100-MC-415-RA3
RECEIVING TANK
Review: 0
DESIGN DATA
Dimensions
Internal diameter(D)..................................... 1,200 mm
Length (T - T)........................................... 2,602 mm
Low head (1)............................................. Torispherical
Top head (2)............................................. Torispherical
Design material
Shell.................................................... A/SA-240 T304
Low head................................................. A/SA-240 T304
Top head................................................. A/SA-240 T304
Necks.................................................... A/SA-312 T304
Fittings................................................. A/SA-182 F304
Legs..................................................... A/SA-312 T304
Joint efficiency(E).......................................... 0.85
Hydrostatic test
Hydrostatic test pressure................................ 1.3 MAWP
Test fluid specific gravity.............................. 1.00
Maximum stress during the test........................... 90.0 % Yield stress(Sy)
Page 3 of 12
CALCULATION MEMORY Doc. No.: 100-MC-415-RA3
RECEIVING TANK
Review: 0
Shell design
Internal diameter(D)........................................ 1,200 mm
Length (T - T)........................................... 2,602 mm
Minimum thickness by UG-16 (t0)............................. 1.59 mm
Corrosion Allowance......................................... 1.5 mm
Design pressure(PD)......................................... 0.34 MPa
Design temperature(To)...................................... 150 °C
Specific Gravity (G)........................................ 0.88
Water density (rH2O)........................................ 1.00 kg/dm^3
Material
Shell....................................................... A/SA-240 T304
Low head.................................................... A/SA-240 T304
Top head.................................................... A/SA-240 T304
Maximum allowable stress value at T0(S)........................... 515 MPa
Joint efficiency(E).......................................... 0.85
Thickness
The minimum required thickness for any component that retains pressure(excluding allowable corrosion) is 1.59 mm (0.0625 in), in
accordance with UG-16 previsions.
For the case of vertical cilindrical vessels, the hydrostatic pressure (PH) of the design fluid shall be added to the design
pressure.
If the specific weight of the design fluid is less than the specific weight of water, the specific weight of water shall be
used to calculate the design fluid hydrostatic test. If the specific weight of the design fluid is greather than the specific
weight of water, the specific weight of the design fluid shall be used to calculate the hydrostatic pressure.
P = PD + PH
H1 = 2,246 mm Height for hydrostatic pressure calculation one feet over the union of low head with the first course.
H2 = 722 mm Height for hydrostatic pressure calculation one feet over the union of first course with the second course.
rF = 0.88 * rH2O
rF = 0.00088 kg/cm^3 < rH2O
rF = rH2O for design
rF = 0.00100 kg/cm^3
The thickness required (tc) to handle the longitudinal stress arising due to the design pressure (PD) and the hidrostatic
pressure (PH), is giving for:
H PH P tc Concepto tc com.
[cm] [MPa] [MPa] [mm] [mm]
224.6 0.022 0.36 2.00 First course thickness 6.00
72.2 0.007 0.35 1.98 Second course thickness 6.00
Page 4 of 12
The thickness required (tc) to handle the hoop stress arising due to the design pressure (PD) and the hidrostatic pressure
(PH), is giving for:
R = D / 2
R = 600 mm
MAWP
The MAWP for the longitudinal stress (MAWPl), for the allowable thickness:
MAWPl = ( S * E * t) / ( R + 0.6 * t)
tc = 6.00 mm
The MAWP for the hoop stress (MAWPc), for the allowable thickness:
MAWPc = ( 2 * S * E * t) / ( R - 0.4 * t)
The shell MAWPs is the smallest value between the MAWPc y MAWPl:
Shell weight
Perimeter = π * (D + 2 * tc)
Perimeter = 3.808 m
Page 5 of 12
Shell design for vaccum
LD = 2,602 mm
D0 = 1,200 mm
h = 206.99 mm h / 3 = 69.00 h = Heigth of heads dished section
t = 6.00 mm
L = LD + 2*(h / 3) L = 2,739.99
Ratios
L / D0 = 2.28
D0 / t = 200.00
"A" factor, from ASME BPVC, Section II, Part D, Subpart 3, Figure "G"
A = 0.0001
In accordance with the figure HA-2 of ASME BPVC, Section II, Part D, Subpart 3,"A" factor is at the left of the applicable
temperature-line, the MAWP is:
Pa = 0.0597 MPa < 0.34 MPa The pressure is less than the design pressure, stiffening rings
shall provided.
Pa = (4 * B)/ (3 * D0 / t)
Pa = 0.4000 MPa > 0.34 MPa The assumed thickness of shell used wth four stiffening rings, is
satisfactory.
Page 6 of 12
CALCULATION MEMORY Doc. No.: 100-MC-415-RA3
RECEIVING TANK
Review: 0
Thickness
Hydrostatic pressure
PH = rF * HF rF = 0.00088 kg/cm^3 < rH2O
PH = 0.23 MPa
P = PD + PH
P = 0.57 MPa
For L / r = 15
r = 81 mm
M = (3 + RAIZ(L / r)) / 4
M = 1.72
tt = (P * L * M) / (2 * S * E - 0.2 * P)
tt = 1.15 mm
tt = 5.00 mm comercial
Dimensions s
D = 1,200 mm
L = 1,212 mm D t
r = 81 mm
sf = 51.00 mm L
tt = 5.00 mm
BC = L - r AB = D / 2 - r
BC = 1,131.20 mm AB = 519.20 mm
h = L - RAIZ(BC^2 - AB^2)
h = 206.99 mm
Page 7 of 12
Head 1 total heigh (Ht)
Ht = h + sf + tt
Ht = 262.99 mm
Page 8 of 12
CALCULATION MEMORY Doc. No.: 100-MC-415-RA3
RECEIVING TANK
Review: 0
Static loads
Nozzles :
Weight : 200.00 kg
Stiffening rings :
Rings : 4
Length : 15.08 m
Weight/m : 10.13 kg/m
Total weight : 152.75 kg
Total : 352.75 kg
Page 9 of 12
CALCULATION MEMORY Doc. No.: 100-MC-415-RA3
RECEIVING TANK Review: 0
Shell = 479.57 kg
Low head 1 = 74.00 kg
Top head 2 = 74.00 kg
Static loads = 352.75 kg
Total vessel weight = 980.32 kg
Tank weight in operation (90 % capacity) Tank weight filled of water for hydrostatyc test (100 % capacity)
Weight of fluid = 2,696.63 kg Weight of water = 3,370.79 kg
TOTAL 3,676.95 kg TOTAL 4,351.11 kg
Leg supports
For the calculation of the axial load (Pc)that every leg will be submited,next conditions will be considered:
a) The normal load conditions, operation and test will be into account.
b) Wind and seism conditions will be into account.
Pw = 1,088 kg
Fs = C * W
C = Seismic coeficient
C = 0.24
W = 3,676.95 kg
Fs = 882.47 kg
Page 10 of 12
Height to the action line of the load force by seism(h)
h = 2 L / 3 + Lc
h = 2.898 m
Calculation of the reaction forces and moments at the support points of columns A and B, generated by the application of the
seismic force.
Column A Column B
SMA = RBY*D0 - Fs*h = 0 SFBX = Fs - RAX - RBX = 0
RBY = Fs*h / D0 Fs = RAX + RBX
RBY = -2,130.92 kg RAX = RBX
Fs = 2RAX
RAX = Fs / 2
RAX = -441.23 kg
RBX = -441.23 kg
Page 11 of 12
IPR compression stress (sIPR)
sIPR = Pc / AIPR
AIPR = 19.00 cm^2
sIPR = 169.40 kg/cm^2 < scr The propossed shape is appropiate
Base plate
Tube diameter................................................... 11.4 cm
Area (A)........................................................ 102.07 cm^2
Plate dimensions
Length(N)....................................................... 20 cm
Wide(B)......................................................... 20 cm
Base plate area(ABP)............................................ 400 cm^2
Concrete stress (Fc)............................................ 248 MPa
Page 12 of 12