You are on page 1of 1

DEPT.

OF TRANSPORTATION

DEPT. OF TRANSPORTATION
DIVISION OF HIGHWAYS

DIVISION OF HIGHWAYS
NORTH CAROLINA

NORTH CAROLINA
RALEIGH, N.C.

RALEIGH, N.C.
STATE OF

STATE OF
E
7-06

7-06
EXIST. PIPE PROP. PIPE D
R
E E E
T
E
M
IA
D
F

METRIC STANDARD DRAWING FOR


METRIC STANDARD DRAWING FOR

PIPE COLLAR
PIPE COLLAR

SIDE ELEVATION
ELEVATION
D E F
GENERAL NOTES:
300 300 300 0.25
USE PIPE COLLAR FOR EXTENDING EXISTING CONCRETE PIPE 375 300 300 0.29
CULVERTS, AT LOCATIONS SHOWN ON PLANS OR
450 300 300 0.33
AS DIRECTED BY THE ENGINEER. THIS INCLUDES EXTENDING
EXISTING PIPES WITH PIPES OF DIFFERENT MATERIALS. 600 300 300 0.40
750 300 300 0.48
CONSTRUCT THE PIPE COLLAR WITH CLASS "B" OR BETTER
CONCRETE. 900 300 300 0.56
1050 300 300 0.65
OBSERVE ALL REQUIREMENTS OF SECTION 840 OF THE STANDARD
SPECIFICATIONS. 1200 300 300 0.74
USE 300mm DIAMETER VALUES FOR PIPE DIAMETERS LESS
1350 450 450 1.88
*
THAN 300mm. 1500 450 450 2.08
Note: 1650 450 450 2.28
This drawing is dimensioned in 1800 450 450 2.49
SHEET 1OF 1 millimeters unless otherwise SHEET 1OF 1
depicted within the drawing.
840.72 840.72

You might also like