Professional Documents
Culture Documents
HDW
HOLLOW CORE WOOD
DOOR
HARDWARE
RAU
RB
RUBBERIZED ASPHALT
UNDERLAYMENT
RUBBER BASE
DRAWINGS RENOVATION
BSM
BSMT
BUILDING SYSTEMS
MANUFACTURER
BASEMENT
HDWD
HK
HM
HARDWOOD
HOOK
HOLLOW METAL
RCP
RD
REBAR
REFLECTED CEILING
PLAN
ROOF DRAIN
REINFORCING BAR
S0-0
S0-1
S1-0
GENERAL NOTES AND DETAILS
GENERAL NOTES AND DETAILS
PLANS, SECTIONS & DETAILS
& ADDITION
TO NORTH
BTW BTW HOR HORIZONTAL
RECP RECEPTACLE S2-0 CANOPY PLANS, SECTIONS & DETAILS
BU ROD BACK-UP ROD HP HIGH POINT
HR HOUR REF REFER OR REFERENCE
BUR BUILT-UP ROOF
HS HEADED STUD REINF REINFORCING ARCHITECTURAL
BW BEARING WALL
C
CDR CARD READER
HSKP
HT
HW
HOUSEKEEPING
HEIGHT
HAND WASH
RELOC
REQ'D
REV
RELOCATE/RELOCATED
REQUIRED
REVERSE
WM2A ARCHITECTS
348 COTTON AVENUE SUITE 500
MACON, GEORGIA 31201
MACON
CEM
CER
CG
CEMENT
CERAMIC
CORNER GUARD
I
ID INSIDE DIAMETER
RFVC
RM
RO
RECESSED FIRE VALVE
CABINET
ROOM
ROUGH OPENING
478-745-4945
CONTACT: TREY WOOD PARK
CIP
CJ
CJ
CAST IN PLACE
CONTROL JOINT
CONSTRUCTION JOINT
INSUL
INT
INSULATION
INTERIOR
RTF
RTU
ROOF TOP FAN UNIT
ROOF TOP UNIT
AS-1
AD-1
A1-0
ARCHITECTURAL SITE PLAN
DEMOLITION FLOOR PLAN
FLOOR PLAN - EXISTING
RECREATION
J
CENTER
CL CENTER LINE
JT JOINT
S A1-1 FLOOR PLAN - NEW WORK
CLR CLEAR
SAB SOUND ATTENUATION A1-2 ENLARGED FLOOR PLAN, SCHEDULES & ACCESSORIES
CMU CONCRETE MASONRY BLANKET
UNIT K A1-3 CANOPY PLANS & SECTIONS
SB SPLASH BLOCK
CNTRTOP COUNTERTOP K KIPS (1000 LB) A1-9 ROOF PLAN & ROOF DETAILS
SBC STANDARD BUILDING
COL COLUMN KO KNOCK-OUT CODE A2-1 EXTERIOR ELEVATIONS
COMM COMMUNICATIONS KP KICKPLATE SCHED SCHEDULE A2-2 DOOR SCHEDULE & DETAILS
CONC
CONN
CONCRETE
CONNECTION
KPD
KSF
KEYPAD
KIPS PER SQUARE FOOT
SCR
SCWD
SCRIBE
SOLID CORE WOOD
A2-3
A3-1
WINDOW SCHEDULE & DETAILS
BUILDING SECTIONS
BIBB COUNTY
CONST
CONT
CONSTRUCTION
CONTINUOUS
KT KEYBOARD TRAY
SD
DOOR
SOAP DISPENSER
A3-2
A3-3
WALL SECTIONS
WALL SECTIONS
RECREATION
COORD
CORR
COORDINATE
CORRIDOR
L
LAV LAVATORY
SDL SUPERIMPOSED DEAD
LOAD
A3-4
A4-1
WALL SECTIONS
WALL DETAILS
DEPARTMENT
CR CRASH RAIL LG LONG SECT SECTION
CSK COUNTERSUNK LGMS LIGHT GAUGE METAL SHR SHOWER A5-1 INTERIOR ELEVATIONS
CSS CLINICAL SERVICE SINK STUD SHT SHEET A5-2 INTERIOR ELEVATIONS
CT CERAMIC TILE LKB LOCKABLE SHW SHOWER A5-3 INTERIOR ELEVATIONS
CTD CENTERED LL LIVE LOAD SIM SIMILAR A5-4 CASEWORK DETAILS
CTR CENTER LLH LONG LEG HORIZONTAL SJ SCORED JOINT A6-1 REFLECTED CEILING PLAN
CW CURTAIN WALL LLV
LOC
LONG LEG VERTICAL
LOCATION
SMS
SO
SHEET METAL SCREW
STRUCTURAL OPENING
A7-1 FINISH PLAN & SCHEDULE 815 N MACON PARK DR
D LTG LIGHT SOG SLAB ON GRADE MECHANICAL MACON, GA 31210
D DEPTH LTP LIGHT POLE SP SPANDREL PANEL
AH&P ENGINEERING
DET DETAIL LWC LIGHTWEIGHT CONCRETE SPA SPACE, SPACING
250 CHARTER LANE
DIA DIAMETER SPEC SPECIFICATION
M SQ SQUARE
MACON, GA 31210
DIAPH DIAPHRAGM REVISIONS
DIM DIMENSION MAS MASONRY SS STAINLESS STEEL 478-405-8301
DJ DEFLECTION JOINT MAT'L MATERIAL STA STATION CONTACT: ROB McGREGGOR # DATE DESCRIPTION
DL DEAD LOAD MAX MAXIMUM STD STANDARD
DN DOWN MECH MECHANICAL STIFF STIFFENER DRAWINGS
DS DOWNSPOUT MEMB MEMBRANE STL STEEL
DW DRYWALL MFG MANUFACTURER STRUC STRUCTURAL MD101 MECHANICAL DEMOLITION FLOOR PLAN
DWG DRAWING MIN MINIMUM SUSP SUSPENDED M101 MECHANICAL NEW WORK FLOOR PLAN
DWMS DRY WALL METAL STUD MISC MISCELLANEOUS SYM SYMMETRICAL M501 MECHANICAL DETAILS
MO MASONRY OPENING SYS SYSTEM M601 MECHANICAL LEGEND, GENERAL NOTES & SCHEDULES
E MOD MODIFIED
EA EACH MOD BIT MODIFIED BITUMEN T
MSL MEAN SEA LEVEL T TREAD
PLUMBING
EF EACH FACE
EIFS EXTERIOR INSULATION MT METAL THRESHOLD T&B TOP AND BOTTOM AH&P ENGINEERING
AND FINISH SYSTEM MTL METAL T&G TONGUE AND GROOVE 250 CHARTER LANE
EJ EXPANSION JOINT TC TOP OF CURB MACON, GA 31210
EL ELEVATION N TEL TELEPHONE 478-405-8301
ELEC ELECTRIC N/A NOT APPLICABLE TEMP TEMPERATURE CONTACT: RODNEY HOPKINS
ELEV ELEVATOR NA NOT AVAILABLE THK THICK
EQ EQUAL NIC NOT IN CONTRACT TLT TOILET DRAWINGS
EQUIP EQUIPMENT NOM NOMINAL TOB TOP OF BEAM
ESC ESCALATOR NS NEAR SIDE TOC TOP OF CONCRETE P101 PLUMBING DEMOLITION AND NEW WORK PLANS, DETAILS,
EW EACH WAY NTS NOT TO SCALE TOF TOP OF FOOTING
SCHEDULE AND LEGEND
EWC ELECTRIC WATER NWC NORMAL WEIGHT TOP TOP OF PARAPET
COOLER CONCRETE TOS TOP OF SLAB
EXIST, EX, EXISTING TOSTL TOP OF STEEL ELECTRICAL
EXG O TRK TRACK AH&P ENGINEERING
EXP BLT EXPANSION BOLT O,C OWNER FURNISHED, 250 CHARTER LANE
TW TOP OF WALL
EXT EXTERIOR CONTRACTOR INSTALLED MACON, GA 31210
CONSTRUCTION DOCUMENTS
TYP TYPICAL
O,O OWNER FURNISHED,
OWNER INSTALLED
478-405-8301 Date: 05/16/2016
F
OA OVERALL
V CONTACT: ED MILLER
FD FLOOR DRAIN
UNO UNLESS NOTED
FDN FOUNDATION OC ON CENTER OTHERWISE
OD OUTSIDE DIAMETER DRAWINGS Drawn By: BEJ/SP
FE FIRE EXTINGUISHER VAR VARIES
FEC FIRE EXTINGUISHER OD OVERFLOW DRAIN
VCT VINYL COMPOSITION TILE
CABINET OH OPPOSITE HAND
VERT VERTICAL
ED101 ELECTRICAL LIGHTING DEMOLITION FLOOR PLAN Checked By: CG
FF FINISH FLOOR OPNG OPENING
VEST VESTIBULE ED201 ELECTRICAL POWER DEMOLITION FLOOR PLAN
FFE FINISH FLOOR ELEVATION OPP OPPOSITE
VTR VENT THROUGH ROOF ED301 ELECTRICAL LOW VOLTAGE DEMOLITION FLOOR PLAN
FH FIRE DYDRANT OSF OUTSIDE FACE
VWC VINYL WALL COVERING E101 ELECTRICAL NEW WORK LIGHTING FLOOR PLAN Project Number: 2016-08
FHC FIRE HOSE CABINET E201 ELECTRICAL NEW WORK POWER FLOOR PLAN
P
W E301 ELECTRICAL NEW WORK LOW VOLTAGE FLOOR PLAN Sheet Name:
PC PORTLAND CEMENT
W WIDTH E701 ELECTRICAL DETAILS
PCF POUNDS PER CUBIC
FOOT
W/ WITH E801 ELECTRICAL LEGEND AND SCHEDULES COVER SHEET &
W/O WITHOUT
PD PENCIL DRAWER
WD WOOD
DRAWING INDEX
WF WIDE FLANGE
5/27/2016 9:10:47 AM
WL WIND LOAD
WP WATERPROOF(ING) Sheet Number:
WP WORK POINT
WR WATER RESISTANT
WWF WELDED WIRE FABRIC
G0-0
WALL TYPE (SEE A4-1)
STUD/CMU WIDTH
WALL TYPE MODIFIER FIRE RATING WALL HATCH PATTERN LEGEND
NAME
ROOMS - 2012 NFPA 101 OCCUPANT LOAD ANALYSIS
RM # AREA NFPA 7.3.1.2 OCC USE NFPA 7.3.1.2 ROUNDED
LIFE SAFETY INFORMATION
WALL TYPE MODIFIER A. 5/8" GYP BD EACH SIDE (NO SAB: STC 45 / WITH SAB: STC 49) 0 NOT RATED PARTITION TO RESIST THE OCC. LOAD OCC'S
BUILDING INFORMATION :
B. 5/8" GYP BD EACH SIDE UL# U465, GA FILE NO: WP1200 (NO S PARTITION TO RESIST THE PASSAGE OF SMOKE PASSAGE OF SMOKE PROJECT NAME: RENOVATION & ADDITION TO NORTH MACON PARK RECREATION CENTER
FIRE RATING
SAB: STC 45 / WITH SAB: STC 49) B 1 HOUR RATED SMOKE BARRIER ADDRESS: 815 NORTH MACON PARK DRIVE
C. (2) LAYERS 5/8" GYP BD EACH SIDE UL# U411, GA FILE NO: C 2 HOUR RATED SMOKE BARRIER 1 HOUR RATED FIRE ASSEMBLY, UNCONCENTRATED
MACON, GA 31210
WP1548 (NO SAB: STC 50 / WITH SAB: STC 54) 1 1 HOUR RATED FIRE BARRIER BARRIER CRAFT 114 419 SF ASSEMBLY, UNCONCENTRATED 15 28 USE: GYMNASIUM
A2F3 D. (1) LAYER 1" GYP BD SHAFT SIDE, 2 LAYERS 1/2" GYP BD 2 2 HOUR RATED FIRE BARRIER / FIRE WALL 1 HOUR RATED SMOKE GATHERING AREA 105 280 SF ASSEMBLY, UNCONCENTRATED 15 19 OWNER: MACON-BIBB COUNTY RECREATION DEPARTMENT
OTHER SIDE UL# U438, GA FILE NO: WP 7095 (NO SAB: STC 45 / 3 3 HOUR RATED FIRE WALL BARRIER GYMNASIUM 127 7,140 SF ASSEMBLY, UNCONCENTRATED 15 476
WITH SAB: STC 49) 4 4 HOUR RATED FIRE WALL NON RATED
E. (1) LAYER 5/8" GYP BD EXPOSED SIDE ONLY (NO SAB: STC 45 /
MP ROOM 112 978 SF ASSEMBLY, UNCONCENTRATED 15 66 CODE ANALYSIS :
# STUD WIDTH CMU WIDTH SYMBOL DESIGNATION MASONRY
WITH SAB: STC 49) MP ROOM 119 760 SF ASSEMBLY, UNCONCENTRATED 15 51 I. APPLICABLE CODES:
1 1 5/8" NON RATED MASONRY
F. NO SHEATHING FOR WALL TYPES INDICATED TO RECEIVE SOUND MTG ROOM 106 954 SF ASSEMBLY, UNCONCENTRATED 15 64 - NFPA 101 - LIFE SAFETY CODE (2012),
2 2 1/2" STACKED WALL - CMU BASE &
G. 7/8" HAT CHANNELS W/ 5/8" GYP BD EACH SIDE ATTENUATION, EXTEND SOUND ATTENUATION TO FULL TROPHY CASE 103 38 SF ASSEMBLY, UNCONCENTRATED 15 3 - RULES AND REGULATIONS FOR THE STATE MINIMUM FIRE SAFETY; CH. 120-3-20
3 3 5/8" GYP FURRING WALL TOP
H. 7/8" HAT CHANNELS W/ 5/8" GYP BD ONE SIDE ONLY HEIGHT OF WALL UNLESS OTHERWISE INDICATED. REFER 707 MODIFICATIONS (2014),
4 3 5/8"
I. NOT USED TO INDIVIDUAL WALL TYPE MODIFIER FOR STC RATINGS. - GEORGIA ACCESSIBILITY CODE FOR BUILDINGS AND FACILITIES; (GAC) - CH.
6 6" 5 5/8" BUSINESS
J. (1) LAYER 5/8" GYP BD EXPOSED SIDE ONLY. TEMPORARY 120-3-20(1997)
8 8" 7 5/8" X#X# OFC. 117 168 SF BUSINESS 100 2
INFECTION CONTROL WALL SEAL TO FLOOR AND DECK. X#X# - INTERNATIONAL FIRE CODE (IFC) (2012),
12 11 5/8" OFC. 116 168 SF BUSINESS 100 2
K. DOUBLE SIDED FURRING WALL - (1) LAYER 5/8" GYP BD - INTERNATIONAL BUILDING CODE (IBC) (2012),
EXPOSED SIDE ONLY OVER TWO LAYERS OF 2 1/2" METAL RECEPT. 104 140 SF BUSINESS 100 2
FRAMING, GYP BD TO BE FLUSH W/ CMU WITH SOUND NO SOUND II. OCCUPANCY TYPE:
6
ATTENUATION ATTENUATION - ASSEMBLY, GROUP A-3 (LSC 6.1.2, CHAPTER 12)
CIRCULATION
CORR. 101 1,927 SF CIRCULATION 0
III. EXISTING BUILDING CONSTRUCTION TYPE:
LEGEND - WALL TYPES VEST. 125 38 SF CIRCULATION 0 - TYPE IIB (IBC TABLE 602.2)
1 1/2" = 1'-0" VEST. 100 55 SF CIRCULATION 0 - TYPE II(0,0,0) (LSC TABLE A.8.2.1)
VEST. 111 40 SF CIRCULATION 0 NEW BUILDING CONSTRUCTION TYPE:
0 - TYPE IIB (IBC TABLE 602.2)
- TYPE II(0,0,0) (LSC TABLE A.8.2.1)
KITCHEN
KITCHEN 108 249 SF KITCHEN 200 2 IV. BUILDING AREA:
2 - ALLOWABLE: 2 STORIES @ 9,500 SF (IBC TABLE 503)
MECH - TOTAL ALLOWED AREA
AK 126 273 SF MECH 300 1 9,500 SF ALLOWED: + 7,125 SF PERIMETER INCREASE (SEE CALCULATION ON LEFT)
ELEC. 110 70 SF MECH 300 1 = 16,625 SF ALLOWABLE AREA
- ACTUAL BUILDING AREA: 1 STORY @ 16,607 SF
2
STORAGE V. HOURLY FIRE RATINGS (IBC TABLE 601, LSC TABLE A.8.2.1):
EQUIP. 128 177 SF STORAGE 300 1 BUILDING COMPONENT RATING
JAN. 118 24 SF STORAGE 300 1 - STRUCTURAL FRAME: 0 HOURS
KILNS 115 205 SF STORAGE 300 1 - BEARING WALLS, EXT.: 0 HOURS
- BEARING WALLS, INT.: 0 HOURS
PANTRY 109 36 SF STORAGE 300 1
- NON-BEARING WALLS, EXT.: 0 HOURS
STORAGE 113 80 SF STORAGE 300 1 - NON-BEARING WALLS, INT.: 0 HOURS
STORAGE 107 48 SF STORAGE 300 1 - FLOOR CONSTRUCTION: 0 HOURS
STORAGE 120 71 SF STORAGE 300 1 - ROOF CONSTRUCTION: 0 HOURS
STORAGE 129 132 SF STORAGE 300 1
8 VI. FIRE SUPPRESSION SYSTEM:
- PORTABLE FIRE EXTINGUISHERS
TOILET
SHOWERS F 122 53 SF TOILET 1 VII. FIRE SAFETY CONCEPT:
SHOWERS M 124 120 SF TOILET 2 - APPEND A NON-SEPARATED ADDITION TO A TYPE IIB, NON-SPRINKLED BUILDING. FIRE
TLT F 121 268 SF TOILET 6 ALARM & PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED.
TLT M 123 407 SF TOILET 4
VIII. OTHER LIFE SAFETY CONSIDERATIONS (MOST STRINGENT OF APPLICABLE CODES
13
GOVERNS):
TOTAL OCCUPANT LOAD 738
A. OCCUPANT LOAD: (IBC TABLE 1004.1.2, LSC 7.3.1.2)
REFERENCE FLOOR PLAN & SCHEDULE FOR INDIVIDUAL LOADS
TOTAL OCCUPANT LOAD = 738 OCCUPANTS
RENOVATION
E. TRAVEL DISTANCE (IBC TABLE 1016.2) = 200 FEET ALLOWABLE
- LSC 12.2.6.2 ALLOWS 200’ FROM ANY POINT IN A ROOM TO EXIT
MAXIMUM ACTUAL EXIT DISTANCE = 63'-1"
119
MP ROOM
ASSEMBLY, UNCONCENTRATED OCC. TYPE
760 SF @
F. INTERIOR FINISH
1. INTERIOR WALL AND CEILING FINISH (IBC TABLE 803.5, LSC 12.3.3.2)
INTERIOR WALL AND CEILING FINISH COMPLYING WITH 10.2.3 SHALL BE AT
A MINIMUM REQUIREMENT CLASS A IN EXIT ENCLOSURES AND
& ADDITION
EXIT #4
15 SF/P =
51 People EXIT #5
PASSAGEWAYS, CLASS B IN CORRIDORS, AND CLASS C IN OFFICE AREAS.
TO NORTH
33.63
26 2. INTERIOR FLOOR FINISH (LSC 12.3.3.5) - CLASS II
OCCUPANTS = 48 OCCUPANTS = 26
WIDTH REQUIRED = 9.6"
WIDTH PROVIDED = 33.63" 26
STORAGE
WIDTH REQUIRED = 5.2"
WIDTH PROVIDED = 33.63" MACON
PARK
120
STORAGE OCC. TYPE
EXIT #3 71 SF @
33.63
OCCUPANTS = 239 48 300 SF/P =
68
.5
STORAGE OCC. TYPE
24 SF @
300 SF/P =
1 People
40 (IBC SEC. 709) RECREATION
FEC VEST.
125 • PATH OF TRAVEL
NOTE: NOT AN EXIT
38 SF FEC
• FIRE EXTINGUISHER / DEPARTMENT
25
CABINET
FEC • EXITING OCCUPANT LOAD
MP ROOM
"
1/8
112
EQUIP. CRAFT
1
STORAGE OCC. TYPE NOTE: HALF OF 15 SF/P = ASSEMBLY, UNCONCENTRATED OCC. TYPE
2 177 SF @ GATHERING AREA 66 People 419 SF @
300 SF/P = OCCUPANTS WILL BE 15 SF/P =
1 People SPLIT FOR EGRESS 28 People
GYMNASIUM
127
ASSEMBLY, UNCONCENTRATED OCC. TYPE 33 29
7,140 SF @ EXIT #7
15 SF/P =
476 People RECEPT. OCCUPANTS = 66
VEST.
72.75
104
111
66
WIDTH REQUIRED = 13.6"
BUSINESS OCC. TYPE
140 SF @ 40 SF WIDTH PROVIDED = 72.75"
100 SF/P = 32 33 4
2 People
2
CORR.
101
KITCHEN
TROPHY 1,927 SF 108
CASE KITCHEN OCC. TYPE
103 MTG ROOM 249 SF @
CONSTRUCTION DOCUMENTS
ASSEMBLY, UNCONCENTRATED OCC. TYPE 200 SF/P =
106
38 SF @ FE ASSEMBLY, UNCONCENTRATED OCC. TYPE
2 People Date: 05/16/2016
15 SF/P = 954 SF @
3 People VEST. 15 SF/P =
100 64 People
55 SF STORAGE ELEC.
Drawn By: BEJ
107 110
STORAGE OCC. TYPE MECH OCC. TYPE
NOTE: NOT AN EXIT 79
48 SF @
300 SF/P =
70 SF @ Checked By: CG
PANTRY 300 SF/P =
68.5 1 People 109 1 People
STORAGE OCC. TYPE
36 SF @ Project Number: 2016-08
300 SF/P =
1 People
239*
WIDTH PROVIDED = 68.5" WIDTH PROVIDED = 68.5"
5/27/2016 9:10:50 AM
SEE SITE PLAN FOR FIRE
HYDRANT LOCATION
Sheet Number:
1
LIFE SAFETY PLAN
1/8" = 1'-0"
SCALE: 1/8" = 1'-0"
NEW
396. 394.
7 0
EX
G
EXISTING AIR HANDLING
& ELECTRICAL
DS
EQUIPMENT TO REMAIN
DS
RENOVATION
& ADDITION
CONCRETE HVAC UNIT
TO NORTH
EXISTING 15,465 GSF
RECREATION CENTER MACON
PAD
DS
PARK
RECREATION
388
DS ' CENTER
384
DS ' BIBB COUNTY
FFE = 397' RECREATION
+/- EXG. TRANSFORMER
ENCLOSURE & PAD 380 DEPARTMENT
'
DS DS
MAX
LP LP
CONCRETE SIDEWALK
FH
ASPHALT PARKING
LOT
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
Sheet Name:
UTILITIES AND GRADING
PLAN
5/31/2016 8:53:40 AM
Sheet Number:
1
LANDSCAPING SITE PLAN
1" = 10'-0" C-1.0
EXISTING PLAYGROUND TO REMAIN
NEW
396. DS2 394.
7 0
EX
G
RD
DU
SD1 & ADDITION
CONCRETE HVAC UNIT
TO NORTH
EXISTING 15,465 GSF
RECREATION CENTER MACON
PAD
DS
PARK
RECREATION
DS
388
'
CENTER
DS1
DU
384
DS ' BIBB COUNTY
FFE = 397' RECREATION
EXG. TRANSFORMER
+/-
ENCLOSURE & PAD 380 DEPARTMENT
'
DS DS
815 N MACON PARK DR
EXG CONCRETE NEW ENTRANCE MACON, GA 31210
376
SIDEWALK CANOPY DS1 SD1 '
DU REVISIONS
NEW CONCRETE BENCH W/
# DATE DESCRIPTION
SKATEBOARD STOPS @ 36" OC
MAX
SD1 SD1
LP LP
CONCRETE SIDEWALK
FH
CO
ASPHALT PARKING
CONSTRUCTION
LOT ENTRANCE
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
Sheet Name:
INITIAL STORMWATER
POLUTION PREVINTION
PLAN
5/31/2016 8:55:33 AM
Sheet Number:
1
LANDSCAPING SITE PLAN - NOTES -
ONE
1" = 10'-0" C-6.1
EXISTING PLAYGROUND TO REMAIN
1 396. DS3
' 4 7396.
DS
+/- DS
394.
396.
9 396. 1
5 3 5
NEW
396. 394.
7 0
DS2
EX
G
RD
DS3
TO NORTH
EXISTING 15,465 GSF TP
MACON
RECREATION CENTER
PARK
PAD
DS
RECREATION
388
'
CENTER
DS
FFE = 397'
RECREATION
+/- EXG. TRANSFORMER DEPARTMENT
ENCLOSURE & PAD 380
'
DS DS
815 N MACON PARK DR
NEW ENTRANCE MACON, GA 31210
EXG CONCRETE CANOPY 376
SIDEWALK DS4 DS4 SD1 '
TP TP REVISIONS
NEW CONCRETE BENCH W/ # DATE DESCRIPTION
SKATEBOARD STOPS @ 36" OC
MAX
DS3
LP LP TP
CONCRETE SIDEWALK
FH
ASPHALT PARKING
LOT
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
Sheet Name:
FINAL STORMWATER
POLUTION PRENTION
PLAN
5/31/2016 8:56:16 AM
Sheet Number:
1
LANDSCAPING SITE PLAN - NOTES -
TWO
1" = 10'-0"
C-6.3
LEGEN
RENOVATION
& ADDITION
TO NORTH
MACON
PARK
RECREATION
CENTER
BIBB COUNTY
RECREATION
DEPARTMENT
REVISIONS
# DATE DESCRIPTION
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
Sheet Name:
STORMWATER
POLUTION PREVENTION
DETAILS
5/31/2016 8:58:14 AM
Sheet Number:
C-6.4
I. General III. Reinforcing Steel VI. Structural Steel
8. 54 16 118 10
Snow Load Information b.
A. Ground snow load (Pg) = 5 PSF Extend all footing reinforcement to far side of footing. See note below for concrete coverage. 50% of the value from the "Maximum total uniform load in Kips" tables
B. Flat-roof snow load (Pf) = 5.5 PSF of the AISC 13th Edition (Black book) Or,
C. Snow exposure factor (Ce) = 1.0 9.
D. Snow load importance factor(Is) = 1.1 Provide dowels in wall footing to match wall verticals unless noted otherwise on drawings. Provide class B splice. Use standard ACI c. 3.
E. Thermal factor (Ct) = 1.0 90 degree hook with 3" clear to bottom of footing unless noted otherwise. See detail "Corner bar & splice length detail (in The minimum number of bolts in single shear as follows: Steel stud designer shall provide sealed shop drawings showing design criteria, member size and spacing, header and jamb
concrete)" Class B Splice or Corner Bar per ACI 318 conditions, connections between members and to the building structure.
Wind Load Information
A. Ult. wind speed = 120 MPH 3000 psi Concrete 4000 psi Concrete 5000 psi Concrete # of 3/4" dia. Length of LL 4.
Beam Shape* A325 bolts 3 1/2" x 3 1/2" x 5/16"
B. ASD wind speed = 93 MPH Bar # Unless specified by finish or glazing system manufacturer's more stringent requirements (general contractor to coordinate), design
Min. Splice Min. Splice Min. Splice Min. Splice Min. Splice Min. Splice
C. Wind importance factor (Iw) = 1.0 serviceability shall meet the following minimum requirements:
(inches) (bar diam.) (inches) (bar diam.) (inches) (bar diam.) W8 , W10 4 5 1/2
D. Occupancy Category = III a Brick Veneer = L/600
E. Wind Exposure = C 4 29 25 24 W12 , W14 6 8 1/2 b. Exterior Insulation and Finish System (EFIS) = L/240
F. Internal Pressure Coefficient = +/-0.18 c. Stucco = L/240
G. Components and Cladding = Varies 5 36 57 31 50 28 45 W16 , W18 8 11 1/2
6 43 37 34 5.
W21 10 14 1/2 "C" shaped studs and joists shall have a minimum flange width of 1 5/8" with a minimum return lip of 3/8"; Tracks shall have a
Seismic Design Information
A. Seismic importance factor (Ie) = 1.25 7 63 54 49 W24 12 17 1/2 minimum outstanding leg of 1 1/4"
B. Seismic design category = B 8 72 62 56
C. 0.2 Second Spectral Response Acceleration (Ss) = 0.164 W27 14 20 1/2 6.
D. 1 Second Spectral Response Acceleration (S1) = 0.082 9 81 72 70 62 63 56 All structural members shall be continuous full length. Splicing of members is not permitted unless specifically detailed by the stud
W30 16 23 1/2
E. 0.2 Design Spectral Response Acceleration (SDs) = 0.175 designer.
10 89 78 69
F. 1 Design Second Spectral Response Acceleration (SD1) = 0.131
G. Site class = D (per geotechnical report) 11 98 85 76 7.
H. Response modification coefficient (R) = 3.5 Screws shall be self drilling with a length that ensures three exposed threads beyond penetration of the joined material. Minimum
I. System overstrength factor = 2 Where connections are skewed or the double angle connections screw spacing shall be 3/4", minimum edge distance shall be 3/8". Screw capacities shall be equal to or greater than those given by
J. Deflection amplification factor (Cd) = 2.25 above will not fit, the following connections shall be used: The Steel Stud Manufacturer's Association with a 3.0 factor of safety.
K
o
r
n
e
g
a
y
E
n
g
i
n
e
e
r
i
n
g
I
n
c
.
K. Seismic response coefficient (Cs) = 0.062
L. Design base shear (Vx) = Varies End of Beam Connections* 8.
a. Provide seismic bracing and details in conformance with IBC Section 1621. Lateral bracing at the top of interior walls and ceiling
M. Basic Seismic Force Resisting System - Building frame systems - Intermediate reinforced masnory shear walls 10. Footings, caissons, and other members where concrete is deposited against soil (Except slabs on grade) = 3"
N. Analysis procedure - Equivalent lateral force procedure # of 3/4" dia. 1/2" Shear Tab grids shall be at 48" on center maximum.
Minimum concrete coverage shall be as follows. If construction documents indicate a larger coverage, it shall be used. If stirrups, ties, Beam Shape* Structural Consultant
or spirals
b. are used, coverage shall be to the outermost face of these elements. A325 bolts Length** 9.
Concrete exposed to weather or soil but is not deposited against soil: All cold formed steel framing accessories or basic clips shall be formed from structural quality steel with minimum yield strength of
363 Pierce Avenue, Suite 202
6. W8 , W10 2 5 1/2 Macon, GA 31204
#6 bar and larger = 2" 50 KSI and have minimum protective coating complying with ASTM 1003/A1003M (or ASTM A653/A653M) G-60 galvanized
All the safety regulations, methods of construction and erection of structural material shall be the responsibility of the general contractor. It shall
be the general contractor’s responsibility to provide adequate shoring, bracing, and framework, etc. as required.
#5 bar and smaller = 1 1/2" W12 , W14 3 8 1/2 coating. Preferred manufacturer: The Steel Network, Inc. (478)745-6161 ph - (478)745-4744 fax
keimacon.com
c. W16 , W18 4 11 1/2 10.
7. Project No: 16-093
Concrete not exposed to weather or soil: Where studs bypass structure (floor and roof) or attach to the bottom of the structure, deflection connections shall allow for positive
Dimensions are not to be derived by scaling these drawings. If there is any question about details or dimensions, contact the Architect and W21 5 14 1/2
Slabs, walls, joists #14 bar and larger = 1 1/2" attachment to structure and stud web using step-bushing technology to provide frictionless, vertical movement. Connection
Structural Engineer for clarification.
Slabs, walls, joists #11 bar and smaller = 3/4" W24 6 17 1/2 products are required to have a valid ICC ES report (ESR-1903) or equivalent complying with ICC acceptance criteria AC261. All
Beams and columns = 1 1/2" structural framing accessories shall be formed from structural quality steel with minimum yield strength of 50 KSI and have
8. W27 7 20 1/2
Where a detail is shown for one condition, it shall also apply for all like or similar conditions, unless noted otherwise. minimum protective coating complying with ASTM 1003/A1003M (or ASTM A653/A653M). Verticlip® or Vertitrack® by The Steel
W30 8 23 1/2 Network, Inc are acceptable products to meet this criteria.
RENOVATION
9. IV. Foundations
Isometric views are for illustrative purposes only. No information about the structure or its components shall be taken or assumed from them. 11.
1. * When the shear tab connection above does not fit in the beam web, use
Lateral drift clips are to provide positive attachment to structure and stud web using step-bushing technology to provide frictionless
II. Structural Masonry The foundation is designed using an allowable soil bearing capacity of 1500 PSF in the absence of a geotechnical the
lateral and vertical movement. Connection products are required to have a valid ICC ES report (ESR-2049) or equivalent complying
adjacent smaller connection and cloud on shop drawings.
& ADDITION
1. report. If the bearing conditions vary from what is shown, or if the soil bearing capacity is questionable, the with ICC acceptance criteria AC261. All structural framing accessories shall be formed from structural quality steel with minimum
All masonry work to be done in accordance with the code-referenced edition of ACI-530 "Building Code Requirements for Masonry Architect and Structural Engineer are to be notified immediately. yield strength of 50 KSI and have minimum protective coating complying with ASTM 1003/A1003M (or ASTM A653/A653M).
Structures", and ACI-530.1 "Specification for Masonry Structures." ** Weld plate to supporting member with 5/16" weld all around.
Driftclip® or Drifttrak® by The Steel Network, Inc are acceptable products to meet this criteria.
Shear tab to be 1/2" thick x 4" wide.
2.
TO NORTH
2. All building areas shall be compacted to 95% of maximum dry density at optimum moisture content as determined in 12.
Mortar shall be Portland cement-lime and conform to ASTM C270. accordance with ASTM D698, current edition. Rigid connections for attachment of metal framing to metal framing and to the primary structure shall be formed from structural
quality steel with minimum yield strength of 50 KSI and have minimum protective coating complying with ASTM 1003/A1003M (or
3. 3. 5. ASTM A653/A653M). Stiffclip® series by The Steel Network includes acceptable products to meet this criteria.
Clay masonry units shall have type N mortar. Net area compressive strength of units shall be 6200 psi. Net area compressive
strength of installed masonry (f’m) shall be 2000 psi. Refer to architectural documents for ASTM designations.
4.
A registered geotechnical engineer representing the owner shall be present to monitor compaction and settlement
and verify the bearing capacity. All work shall be performed in accordance with the recommendations of the
geotechnical report and on-site geotechnical engineer.
Welds shall be made only by operators certified by the standard qualification procedure of the American Welding Society for the
type of weld required. Welder certification shall be submitted for review.
6.
13.
Design bridging clips to provide attachment to stud web and wrapping around the bridging channel. Bridging accessories shall be
formed from structural quality steel with minimum yield strength of 50 KSI and have minimum protective coating complying with
MACON
Concrete masonry units above and below grade shall have type S mortar. Net area compressive strength of units shall be 1900 psi.
Net area compressive strength of installed masonry (f’m) shall be 1500 psi. Concrete masonry units shall conform to ASTM C90.
5.
4.
Remove all topsoil, root system or other deleterious material under proposed slab and column footings and replace
with suitable compacted fill or crushed stone. Structural Engineer's decision on questionable material shall be final.
Weld lengths not noted shall be full length. Terminate welds in accordance with AISC Manual of Steel Construction and American
Welding Society Structural Welding Code - Steel (D1.1).
7.
ASTM 1003/a1003m (or ASTM A653/A653M). Bridgeclip® and Bridgebar® by The Steel Network are acceptable products to meet
this criteria.
14.
PARK
Block fill for reinforced masonry shall be fine grout in conformance with ASTM C476 minimum compressive strength method.
Grout shall be 2000 PSI at 28 days. Grout slump shall be 8 to 11 inches.
6.
5.
Backfilling shall be performed in equal lifts around the building perimeter to balance lateral earth pressure on the
building. Walk behind compaction equipment is required within a distance of two times the wall height.
Holes larger than 1" dia. shall be coordinated with the structural engineer. Holes shall be punched or drilled, except as otherwise
permitted the structural engineer.
8.
Framing of wall openings shall include headers and supporting studs as recommended by the stud manufacturer. Contractors
option: Jamstud® by the Steel Network, Inc to reduce or eliminate built-up framing in jambs, headers, and sills. Use Stiffclip® HE or
Stifflclip® AL to eliminate jack studs.
RECREATION
Reinforcing: ASTM A615 - Grade 60. See table below for minimum lap splice length and embedment of reinforcing bars. 6.
Backfill against structural walls shall not be performed until wall and slab on grade has obtained specified strength.
Protect columns, base places, anchor bolts, and any steel below grade with an approved inorganic or epoxy anti-corrosion
coating, field applied per manufacturer's instructions.
15.
Light gauge straps on both sides of the wall are required to provide shear resistance for shear wall framing. The Steel Network, inc,
Stiffwall® SW-S is an acceptable product to meet this criteria.
CENTER
Masonry Reinforcing Lap Splices and Embed Length 7. 9.
If required by the geotechnical report or the on-site Geotechnical Engineer, the ground water table shall be lowered. All exposed structural steel including lintels, and as noted on drawings, shall be galvanized in conformance with ASTM A123.
Bar Size Lap Splice Length (IN) Embedment (IN) Fasteners and small parts requiring galvanizing shall be in conformance with ASTM A153.
8.
10.
#4
#5
24
30
18
24
All footings to be centered under the columns or walls they support, unless noted otherwise on the drawing.
9.
The contractors shall determine, furnish and install all temporary supports sufficient to secure the structural steel framing against
loads present during erection. Temporary supports shall remain in place until all connections to the lateral load resisting system,
BIBB COUNTY
#6 36 28 Utility lines shall not be placed through or below foundations without the structural engineer’s approval in writing. The
contractor shall locate any existing underground utilities prior to any construction.
including horizontal diaphragms, are complete.
RECREATION
#7 42 32 11.
#8 48 36
10.
Inspections by Geotech firm are required for existing soils conditions, fill placement, and load bearing requirements:
The general contractor shall verify that the correct beam and girder camber is present after erection and before floor slab is
poured.
DEPARTMENT
a.
#9 54 42 Site preparation: Prior to placement of prepared fill, the inspector shall determine that the site has been prepared in 12.
accordance with the above-referenced geotechnical report. Splice continuous steel angles and plates with Partial-Joint-Penetration Square Groove Welds (Joint Designation B-P1a) U.N.O.
7. b. 13.
Masonry preparation, construction and protection in hot or cold weather (greater than 90 degrees Fahrenheit or less than 40 degrees Fill placement: During placement and compaction of fill material, the inspector shall determine that the proper fill Structural steel fabricator and detailer shall see the Architectural drawings for any additional steel not shown or called out in
Fahrenheit) shall be in conformance with ACI 530.1 Section 1.B. material is being used and that the maximum lift thickness is followed in accordance with the above-referenced
these drawings. If size is not shown in architectural drawings a request or information shall be sent to the structural engineer
8.
geotechnical report.
through the proper channels. 815 N MACON PARK DR
Embedded conduits, pipes and sleeves shall be compatible with masonry and shall not be located in grouted cells. Pipes containing c.
Evaluation of in-place density: The inspector shall determine, at the frequencies determined in the soils report and
13. MACON, GA 31210
water subject to freezing, materials in excess of 150 degree Fahrenheit or pipes under pressure in excess of 55 PSI shall not be General contractor shall coordinate connections of joist and joist girders to structural steel.
embedded in masnory. General contractor shall coordinate the location of all embedded items with the Structural Engineer prior to project specifications, that the in-place dry density of the compacted fill complies with the above-referenced
construction. geotechnical report.
V. Submittals
9. 1. REVISIONS
All masonry walls shall be reinforced with horizontal
Horizontal joint reinforcement @ 16" O.C. vertically as follows. The space between these
Joint Reinforcing The contract documents are the structural engineer’s instruments of service to convey design intent. They are not to be considered fabrication
wires shall
CMU beSize
the widest that the mortar joint will accommodate. or layout drawings. # DATE DESCRIPTION
Running Bond Stack Bond
2.
4" (1) W1.7 @ 16" O.C. (1) W1.7 @ 16" O.C.
The follow are required submittals
6" or 8" (2) W1.7 @ 16" O.C. (2) W1.7 @ 16" O.C.
a. Concrete mix design(s)
12" (2) W1.7 @ 16" O.C. (2) W2.8 @ 16" O.C. b. Reinforcing bar drawings
c. Masonry material certificates, accessories, and grout mix design
d. Structural steel
e. Light gauge metal trusses
g. Other submittals as noted on the drawings and specifications
3.
10.
Submittals shall be reviewed by the contractor prior to submission to the Structural Engineer and shall bear the contractor’s stamp attesting to
Vertical rebar shall be centered in block walls U.N.O.
the same. Drawings not stamped will not be reviewed. Subcontractor’s unchecked submittal drawings will not be reviewed.
11.
4.
Masonry cells on which steel or masonry lintels bear must be reinforced with same reinforcing as wall and must be filled with grout.
Submittals to be reviewed by the Structural engineer shall be submitted to the Architect. The Structural Engineer will not accept submittals
If no wall reinforcing is shown a #4 bar shall be assumed.
directly from contractors without the Structural Engineer’s prior approval.
12.
5.
Provide horizontal bond beams in all masonry walls at 10’-0” on center max vertically and within 16” of the top of the wall.
Upon completion of the structural engineer’s review, submittals will be returned to the Architect for their review.
Reinforcing in bond beams shall be 1#4 x continuous for 6” CMU, 1#5 x continuous for 8” CMU, and 1#6 x continuous for 12”
CMU.
6.
Any deviation in design, details, dimensions, etc. from the construction documents shall be clouded on the submittal and verification of the
13.
change shall be requested.
The minimum level of Quality Assurance based on ACI 530 shall be Level B. Refer to Table 1.15.3 in ACI 530.
14.
Where concrete block is above and below equipment platform, fit block tight to underside of beam prior to constructing block above.
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
A.B. -Anchor bolt CONC. -Concrete EOS -Edge of slab HSS -Hollow structural sections MISC -Miscellaneous SPECS -Specifications Checked By: A. Crosby
ADD'L -Additional CONST. -Construction EQ -Equal INT -Interior NA -Not applicable STD -Standard
AFF -Above finished floor CONT. -Continuous EQUIP -Equipment JST. -Joist NTS -Not to scale STL -Steel
COORD. -Coordinate EW -Each way JT. -Joint O.H. -Opposite hand STRUCT -Structural Project Number: 2016-08
ARCH -Architect/Architectural
BFF -Below finished floor DBA. -Deformed bar anchor EXIST -Existing K -Kip(s) O.C. -On center T.O.S. -Top of slab or steel
BM -Beam DET. -Detail EXP -Expansion KSI -Kips per square inch OPNG -Opening T.O.C. -Top of concrete Sheet Name:
DIAG -Diagonal EXT -Exterior LGMF -Light gauge metal framing PL -Plate T.O.F. -Top of footing
BRG
BSMT.
-Bearing
-Basement DIA -Diameter F.F. -Finished floor LLH -Long leg horizontal PREFAB -Prefabricated T.O.W. -Top of wall
General Notes & Details
C.I.P. -Cast in place DIM -Dimension FFE -Finished floor elevation LLV -Long leg vertical PSF -Pounds per square foot TYP. -Typical
CJ -Control joint DWG. -Drawing FIN. -Finsh(ed) LO -Low PSI -Pounds per square inch U.N.O. -Unless noted otherwise
5/17/2016 2:31:25 PM
CL -Center line EA -Each FLR. -Floor LT. -Light PT -Pressure treated VERT. -Vertical
CLR. -Clear EF -Each face FTG. -Footing MAX. -Maximum REF. -Reference W.P. -Work point Sheet Number:
CMU -Concrete masonry unit EJ -Expansion joint GA -Gauge/Gage MECH. -Mechanical REINF. -Reinforcement WT. -Weight
CONN -Connection EL. -Elevation GALV. -Galvanize (d) (ing) MID -Middle REQD -Required W.W.M. -Welded wire mesh
CONST JT
COL.
-Construction Joint
-Column
ENGR
EOD
-Engineer
-Edge of deck
HI
HORZ.
-High
-Horizontal
MFR
MIN.
-Manufacturer
-Minimum
SECT.
SIM.
-Section
-Similar
W.W.F. -Welded wire fabric
S0-0
I. JT. w/ bondbreaker
along wall typ. UNO
NOTE: CONTRACTOR TO SPACE AS
XI. Concrete: REQUIRED IN PLACE OF
CONCRETE BLOCK LINTEL BEAM SCHEDULE
4"
CONTROL JOINTS 3/4"X 1 1/2" Column
1. KEY WAY SPAN LINTEL
All concrete work to be done in accordance with the code referenced edition of ACI-318: “Building Code Requirements for Reinforced
Concrete” 0'-0" to 3'-0" 1 #4 T & 1 #5 B
1 COURSE DEEP
MOISTURE BARRIER UNDER 1 #5 T & 1 #6 B
2. 3'-0" to 5'-0"
ALL CONCRETE SLABS
Concrete mix design requirements and compressive strength at 28 days.
5'-0" to 7'-0" 1 #6 T & 1 #7 B
28 Day Weight per Slump at 2 COURSES DEEP
Description strength cubic foot point of Aggregate Fibermesh or WWM TYPICAL CONSTRUCTION JOINTS (CN.JT.) 7'-0" to 9'-0" 1 #8 T & 1 #9 B
(PSI) (PCF) placement N.T.S.
Footing and Foundation Walls 3000 145 4" +/- 1" ASTM C33 none CJ Max spacing:
12' - 0" Max for 4" thick slab
Slab on grade @ gym
3000 145 4" +/- 1" ASTM C33 Fibermesh @ 1.5lb per cubic yard of conc. 18' - 0" Max for 6" thick slab
wood floor 1/2" PRE MOLDED 24' - 0" Max for 8" thick slab
4"
EXPANSION JOINT
NOTES:
1) LINTELS SCHEDULED ABOVE SHALL BE USED UNLESS SHOWN OR
NOTED OTHERWISE.
MOISTURE BARRIER UNDER 2) LINTELS SHALL HAVE 1" BEARING, EACH END, FOR EACH 1'-0" OF
ALL CONCRETE SLABS SPAN, BUT NOT LESS THAN 8" BEARING EACH END.
Fly ash shall not be used. Water reducing admixtures may be used to achieve slump requirements.
3) CONCRETE BLOCK LINTELS SHALL BE MADE WITH FILLED "U"
TYPICAL ISOLATION JOINT (I. JT.) BLOCKS. FILL SHALL BE MADE WITH COURSE GROUT, CONFORMING
3. Cast diamond or circle TO ASTM C-476, 3/8" MAX. STONE SIZE. SHORE POURED LINTELS
N.T.S. (7) DAYS MINIMUM.
All concrete joints shall be 3/8" wide unless noted on architectural drawings. blk-out min 3" clear to
STL after slab on grade
Discontinue 50% WWF 4) REINFORCING SHOWN ABOVE SHALL BE DOUBLED FOR 12" NOM.
4. has been cast I. JT. w/ bondbreaker
1/8" Saw cut JT or rebar at JT CONCRETE BLOCK LINTELS.
Location of all construction joins, excluding slabs on grade, shall be coordinated with structural engineer.
See Gen
fill with JT filler around diamond or
Notes
circle typical
5. Slab reinf.
1/4 T
Shop drawings shall be submitted to the structural engineer showing proposed locations of any material such as but not limited too Concrete Block Lintel Beam
conduits, embedments, or fixtures to be placed inside any structural concrete member such as beams, walls, slabs, columns or T/Slab
footings. This is not required for slabs on grade of 4" or less in thickness.
9 Schedule
Note: Saw cut joint less than 12 hours after concrete placement
T
S0-1
6.
Concrete slab flatness and levelness tolerances shall be in conformance with ACI 117, and shall be specified by the owner. Unless
a.
superseded by the owner’s criteria, conform to the following minimum requirements:
Provide a floor surface whish is true and level and achieves “F numbers” of FF = 30 and FL = 20
5 Typical Slab on Grade Joint Layout
Note: Moisture barrier
minimum overall composite and FF = 20 and FL = 15 minimum at any individual section, when tested under all slabs S0-1 Scale: NTS
in accordance with ASTM E1155, Remove surface irregularities to provide a continuous smooth T = Slab Thickness
finish. BRICK LINTEL BEAM SCHEDULE
Saw cut joint less than 12 hours
b. after concrete placement SPAN LINTEL
All interior slabs to receive a smooth trowel finish unless noted.
0'-0" to 5'-0" ANGLE 5x5x5/16
TYPICAL SLAB ON GRADE CONTROL JOINT (C.J.)
7.
Unless specified otherwise in the specification, testing of concrete shall be in conformance with the requirements of ACI 318 Section N.T.S. 5'-0" to 7'-0" ANGLE 5x5x5/16
5.6 “Evaluation and Acceptance of Concrete”.
7'-0" to 9'-0" ANGLE 5x5x5/16
K
o
r
n
e
g
a
y
E
n
g
i
n
e
e
r
i
n
g
I
n
c
.
8.
SAW CUTTING CONTROL JOINTS IS AN ATTEMPT TO
Construction joints (CN.JT.) are to be located on the threshold side of a wall. 9'-0" to 11'-0" ANGLE 6x6x5/16
PARTIALLY CONTROL THE SHRINKAGE CRACKS
THAT NATURALLY OCCURS IN CONCRETE DURING NOTES:
9.
THE CURING PROCESS. SOMETIMES THE CONCRETE 1) LINTELS SCHEDULED ABOVE SHALL BE USED UNLESS SHOWN OR Structural Consultant
See detail "Typical Slab on Grade Joint Layout".
WILL CRACK BETWEEN CONTROL JOINTS. NOTED OTHERWISE. 363 Pierce Avenue, Suite 202
10.
Procedure Reference Section #4 x 6' - 0" Long Macon, GA 31204
The following procedures shall meet the requirements of the referenced code sections: 2) LINTELS SHALL HAVE 1" BEARING, EACH END, FOR EACH 1'-0" OF
Centered in slab. SPAN, BUT NOT LESS THAN 8" BEARING EACH END. (478)745-6161 ph - (478)745-4744 fax
Preparation ACI 304 - "Guide for measuring, mixing, 1 Typical Joints keimacon.com
transporting and placing concrete" S0-1 Scale: NTS
Project No: 16-093
Conveying ACI 318 Section 5.9 - "Conveying"
10 WMA Brick Lintel Beam Schedule
Depositing ACI 318 Section 5.10 - "Depositing" C.J. or CN.JT.
S0-1
Consolidation ACI 309 - "Guide for consolidation of concrete"
Curing ACI 308 - "Standard practice for curing concrete" Concrete slab on
Hot weather concreting ACI 305 - "Hot weather concreting" grade, see plan.
RENOVATION
C.J. or CN.JT.
Cold weather concreting ACI 308 "Cold weather concreting" See sections
a
& ADDITION
4"
4"
1
1
FOOTING
See
AS CONTINUOUS FOOTING 24 in.
STEP
splice table REINFORCING or 40db
Splice length
BIBB COUNTY
greater reinf.)
reinforcemen
(see sections,
plans, details
T
Minimum
RECREATION
etc. for
No. 4
8 in.
t
CONTINUOUS
16 in.
maximu maximu DEPARTMENT
T
FOOTING RIENF.
SEE DETAIL m m
See
splice table See table "Class B Splice or Corner Bar per ACI 318"
T on notes sheet for splice length in concrete
Notes: REVISIONS
# DATE DESCRIPTION
Vertical Reinforcement: The vertical reinforcement is required to consist of at least one No. 4 bar at each corner, within
16 inches of each side of openings, within 8 inches of each side of control joints, within 8 inches of the ends of walls,
and at a maximum spacing of 48 inches. These requirements are a minimum. Where sections, details, plans etc. show
greater reinforcing it shall be used.
Horizontal Reinforcement: See masonry general notes for typical horizontal joint reinforcing and bond beam
information. Horizontal reinforcement shall also be provided at the bottom and top of wall openings. Such reinforcement
shall extend at least 24 inches or 40 bar diameters, whichever is greater, past the opening. Structural reinforcement
located at roof and floor levels is required to be continuous. The horizontal reinforcing bar located closest to the top of
the wall shall be placed within 16 inches of the top of the wall.
Neither horizontal nor vertical prescriptive reinforcement is required for openings smaller than 16 inches in either the
horizontal or vertical direction, unless the required prescriptive reinforcement is interrupted by such openings.
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
Sheet Name:
General Notes & Details
5/17/2016 2:31:25 PM
Sheet Number:
S0-1
E2 2 E3 E4 S3 E5 6 E6
E2 2 E3 E4 S3 E5 6 E6
9' - 7 7/8" +/- 27' - 7 7/8" 10' - 5 7/8" 12' - 2 1/2" +/-
9' - 7 7/8" +/- 27' - 7 7/8" 10' - 5 7/8" 12' - 2 1/2" +/-
CJ
CJ
3
S1-0
6
Ridge
CJ S1-0
3 5 Sequence of Demolition and Construction at wall demo:
S1-0 S1-0 1. Demo veneer
2. Install channels and bolts
3. Remove portion of CMU wall at column and footing
(in toilet chase)
4 4. Install footing
5. Install column and fasten column to double channel.
SA
3 5/8"
S1-0 6. Remove remainder of CMU 7
7
7. Add continuous plate to underside of channels. C12X20.7 S1-0 C12X20.7
3 5/8"
S1-0
EG C12X20.7 C12X20.7
7
SA 2' - 0" 2' - 2"
1' - 10"
2' - 0" S1-0
H
SS 4'
Top footing = by light gauge designer. S1-0
3'
EF
4X foo
X
-2' - 0" B.F.F. Fasteners from overbuild
4X tin
5/ g
L6X4X5/16" (LLV) each side of wall. to existing shall be the 6
16
y
Va
lle
Bottom of angle at 10'-4" A.F.F. responsibility of the
lle
Va
S1-0
K
o
r
n
e
g
a
y
E
n
g
i
n
e
e
r
i
n
g
I
n
c
.
light gauge Engineer.
1. Score grout bed
2. Insert angles w/ 8" bearing each end
3. Remove CMU below
Structural Consultant
ED 363 Pierce Avenue, Suite 202
ED Existing barjoist to Macon, GA 31204
support new overbuilt roof (478)745-6161 ph - (478)745-4744 fax
keimacon.com
Project No: 16-093
8" CMU
Demo CMU wall.
Keep below F.F.E.
at each truss clip
RECREATION
2'
4'
Demo brick and keep
CMU below F.F.E.
Metal trusses @ 2' - 0" O.C.
CENTER
secure to PT 2x with clip angle
#4 @ 32" O.C. clip design per LG Engineer
(1) #5 x cont. #4 @ 48" O.C.
0' - 0"
top and bottom vertical bars Double 2x PT plate
0' - 0" 8" concrete
BIBB COUNTY
4"
block wall
4"
dowels and
footing to
4' - 1"
DEPARTMENT
remain
#4 @ 24" O.C.
8" CMU block wall
0' - 0"
(3) #4 x cont.
1' - 0"
4" 4"
Brick - see Arch.
Existing barjoist
to remain
Existing barjoist Light gauge truss
to remain design by LG engineer
Light gauge truss
design by LG engineer
10' - 11"
truss BRG
Existing barjoist seats 8 10' - 11"
Exisitng CMU
to remain. Light gauge Provide (1) 1" dia. A36 Provide (4) 1" dia. A36 truss BRG 10' - 8" A.F.F. top/CMU
S1-0 thru bolts in 24"
overbuild not shown. thru bolt @ 24" O.C. Exisitng CMU (2) 1" dia. A36 bolts @ 24" O.C.
alternating top and bottom bearing section 3/8" x 12" x cont. plate
along beam. C12s to be supported
10' - 8" A.F.F. top/CMU beyond (not shown)
10' - 4" (2) 1" dia. A36 bolts @ 24" O.C. by 1" x 16" x 16" and supported by
along beam. C12s to be supported existing CMU at ends of channels. 9' - 4"
CONSTRUCTION DOCUMENTS
by 1" x 16" x 16" and supported by
existing CMU at ends of channels. 9' - 4" 1" x 16" x 16"
Date: 05/16/2016
C12X10.7 each side to support
column top plate masonry wall as wall below is
C12X10.7 each side to support CMU wall to be demolished. demolished. Leave C12s and
3/8" x 12" x cont. plate bolts in place permanently.
Drawn By: M. Stefano
masonry wall as wall below is See construction sequence on plan
demolished. Leave C12s and
HSS4X4X5/16 Existing veneer to be removed
bolts in place permanently.
CMU wall to be demolished. at locations where CMU wall is demolished Checked By: A. Crosby
See construction sequence on plan Existing veneer to be removed
2' - 0" at locations where CMU wall is demolished 7 5/8"
Project Number: 2016-08
Extg. CMU
Sheet Name:
7 Section 9 8 Section 5 9 Section 3
S1-0 1/2" = 1'-0" S1-0 3/4" = 1'-0" S1-0 3/4" = 1'-0" Plans, Sections & Details
5/17/2016 2:31:26 PM
Sheet Number:
S1-0
2.5 E4
1 7/8" 11' - 0" 10 7/8"
5" +/-
6"
6' - 2 1/4"
6' - 2 1/4"
2.5 11' - 0"
3/8" thick flanges x 6"
1' - 2"
2' - 0"
wide, 50KSI plate steel
3/8" thick web
C1 C1
C1 Full pen weld
50KSI plate steel
Built-up steel beam
from beam to column
W 4'
4'
10 x 1
x
X3 ' -
3 6"
8' - 10"
8' - 10"
Column - see plan
EA EA
2' - 3 1/4"
2' - 3 1/4"
Existing concrete sidewalk
to remain. Patch as required
for new canopy footing installation
C2 C2
C2
Built-up steel beam
W 4'
4'
10 x 1
x
X3 ' -
3 6"
8' - 10"
8' - 10"
Concrete bench
(see details)
#4 @ 24" O.C.
24" (6) #6 x cont.
K
o
r
n
e
g
a
y
E
n
g
i
n
e
e
r
i
n
g
I
n
c
.
Built-up steel beam Existing concrete sidewalk to
C3 C3
C3 remain. Patch as required for
1' - 6"
3 3 new canopy footing installation.
2' - 0"
8" 8"
S2-0 S2-0
0' - 0" Structural Consultant
W 4'
10 x 1
x
1' - 6"
X3 ' -
5"
Project No: 16-093
1' - 6"
1'-1"
3' - 2 5/8" 12' - 5 1/4" 3' - 2 5/8" 12' - 5 1/4"
2' - 6"
#5 @ 12" O.C.
E3 2.5 E4 3"
E3 2.5 E4 4' - 0" x 4' - 0"
each way top and bottom
RENOVATION
1
S2-0
Canopy Foundation Plan
1/4" = 1'-0"
2
S2-0
Canopy Framing Plan
1/4" = 1'-0"
3
S2-0
Section 10
1/2" = 1'-0"
& ADDITION
TO NORTH
MACON
PARK
RECREATION
CENTER
BIBB COUNTY
RECREATION
DEPARTMENT
REVISIONS
# DATE DESCRIPTION
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
Sheet Name:
Canopy Plans, Sections
& Details
5/17/2016 2:31:27 PM
Sheet Number:
S2-0
EXISTING PLAYGROUND TO REMAIN
8'-11"
20'-0"
5'-2 1/8"
DS DS
11'-0"
13'-6"
NEW
EXG
EXISTING AIR HANDLING
& ELECTRICAL
DS
EQUIPMENT TO REMAIN
DS
RENOVATION
CONCRETE HVAC UNIT PAD
& ADDITION
EXISTING 15,465 GSF TO NORTH
RECREATION CENTER MACON
DS
PARK
388'
RECREATION
DS
CENTER
384'
DS
DS DS
LP LP
CONCRETE SIDEWALK
FH
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
Checked By: CG
Sheet Name:
ARCHITECTURAL SITE
PLAN
5/16/2016 4:08:10 PM
Sheet Number:
1
SITE PLAN
1" = 10'-0"
AS-1
GENERAL DEMOLITION NOTES:
KEYNOTES - DEMOLITION - FLOOR PLANS
A. OWNER IS RESPONSIBLE FOR REMOVING ANY FURNITURE PRIOR TO CONSTRUCTION
B. DEMOLITION PLAN IS NOT ALL INCLUSIVE. ADDITIONAL DEMOLITION WORK MAY BE REQUIRED FOR NO. DESCRIPTION
INSTALLING NEW WORK. SEE CIVIL, MECHANICAL, PLUMBING AND ELECTRICAL DWGS FOR DEMOLITION
IN THOSE TRADES. IN AREAS OR ROOMS WHERE ARCHITECTURAL DEMOLITION IS NOT INDICATED AND 1 DEMOLISH INTERIOR WALL. PATCH ASSOCIATED FLOOR FOR FUTURE FINISHES. COORDINATE CUT
MPE IS REQUIRED, REMOVE AND REPAIR ANY ITEMS TO ACCOMMODATE WORK REQUIRED AND DIMENSIONS AND HEIGHTS WITH NEW WORK FLOOR PLANS
RESTORE AREA TO ORIGINAL CONDITIONS BEFORE WORK PROCEEDS.
C. PROTECT ALL EXISTING CONDITIONS THAT ARE TO REMAIN, AS NECESSARY, DURING DEMOLITION 2 DEMOLISH EXTERIOR WALL AS SHOWN. BRACE AS REQUIRED.
PHASE OF CONSTRUCTION. REPAIR ALL DAMAGE PROMPTLY TO ORIGINAL CONDITION. 4 DEMOLISH EXISTING TOILET PARTITIONS. PATCH WHERE NEEDED FOR FUTURE FINISHES.
D. DEMOLITION SHALL INCLUDE ANY REMOVAL OF EXISTING MATERIALS TO MAKE PROVISION FOR NEW 5 REMOVE EXISTING SHOWER STALL FLOOR DRAIN AND THE ASSOC. PLUMBING FIXTURES
FINISHES. 6 REMOVE EXISTING DOORS, FRAMES, THRESHOLDS AND THE ASSOC. SEALANT.
E. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL EXISTING CONDITIONS. THE 7 REMOVE EXISTING COLUMN SURROUND. STRUCTURE TO REMAIN.
ARCHITECT IS TO BE NOTIFIED OF ANY DISCREPANCIES AND ANY DISCREPANCIES RECTIFIED BEFORE
8 REMOVE EXISTING MILLWORK IN ITS ENTIRETY. PATCH AT WALL AND FLOOR FOR FUTURE FINISHES.
WORK IS TO RESUME.
F. ALL STRUCTURAL ITEMS THAT SEEM TO BE SUSPECT FOR REPLACEMENT SHALL BE INSPECTED BY THE 9 REMOVE EXISTING FLOOR FINISH AND ITS ASSOC. ADHESIVE. COORD W/ A7-1 FOR NEW WORK SCOPE
PROJECT ARCHITECT OR STRUCTURAL ENGINEER TO DETERMINE IF THEY SHOULD BE REPLACED. ALL 10 REMOVE EXISTING ACOUSTICAL TILE CEILING AND GRID
STRUCTURAL ITEMS THAT ARE DAMAGED AND NEED REPLACING WILL BE TAGGED BY THE STRUCTURAL 11 REMOVE EXIST ACT CEILING AND GRID TO DIM. SHOWN
ENGINEER AND REPLACED BY THE CONTRACTOR BEFORE ANY OTHER WORK BEGINS 12 TEMPORARILY REMOVE OWNER FURNISHED EQUIPMENT FOR NEW CONSTRUCTION. COORDINATE FINAL
G. ALL DEMOLITION WORK SHALL BE EXECUTED IN A CAREFUL AND ORDERLY MANNER WITH THE LEAST LOCATION WITH OWNER
POSSIBLE NOISE, DUST AND DISTURBANCE TO THE OWNER.
13 REMOVE EXISTING DOWNSPOUT & SPLASHBLOCK. PREPARE GUTTER FOR NEW ROOF CONNECTION
H. THE CONTRACTOR SHALL MAINTAIN AT ALL TIMES ALL EXISTING SMOKE AND FIRE PROTECTION
SYSTEMS. 14 REMOVE EXISTING PLUMBING FIXTURES. PREP FITTINGS FOR NEW FIXTURES
I. THE CONTRACTOR SHALL AT ALL TIMES KEEP ALL EXISTING ACCESS/ EGRESS FREE AND CLEAR OF 15 REMOVE GYP BOARD OR ACT CEILING, BULKHEAD, SKYLIGHT, AND LIGHTING ABOVE FOR NEW WALL
DEBRIS. CONSTRUCTION
J. REMOVE ALL LANDSCAPING AS NECESSARY FOR CONSTRUCTION. VERIFY WITH OWNER IF RELOCATION 16 REMOVE EXISTING CMU VENEER BLOCK & INSULATION. CLEAN BLOCK OF EXISTING WATER-RESISTIVE
OF PLANTS IS REQUIRED. BARRIER FOR NEW PAINT
17 CONTRACTOR TO SEE STRUCTURAL DRAWINGS FOR SHORING REQUIREMENTS & DESIGN
18 REMOVE EXISTING METAL SOFFIT PANELS & ROOFING PER NEW WORK REQUIREMENTS
19 CUT SLAB MIN. 24" FROM NEW WORK WALLS. SEE NEW WORK PLANS FOR DIMENSIONS
20 REMOVE EXISTING WALL TILE AND ITS ASSOC. ADHESIVE. COORD W/ A7-1 FOR NEW WORK SCOPE
21 REMOVE RANGE AND RANGE HOOD. PATCH ALL OPENINGS AND CAP EXPOSED LINES.
E1 E2 2 E3 E4 E5 6 E6
8'-8 1/4" 18 7'-2 1/4" 18 32'-8 7/8" 18
DEMO 8" STRUCTURAL
CMU TO 9'-4" AFF AFTER
13 STRUCTURAL CHANNELS
2 17 16 17 2 17 ARE INSTALLED
EG
9 8 4 14 14 4
8 15 9
5 1 9 19 9
15 1
EF 4 14 14 20 4
5 EXG FD EXG FD
8
5'-0 3/8"
5 20
15 15 EXG FD
4 14 14
9
8 15 20
1
15
5 4 14
8
9 15
E7
6'-4"
1 9 9
9
5 8 15 6
1
ED 1
14'-8 1/4" 9
6
8"
1/
19 '-1
10
ETR RENOVATION
3/
8 " & ADDITION
-9
8'
1
4'-2 7/8" TO NORTH
ETR
1 6'-1 1/8" MACON
ETR
ETR
9 6
9
11
19
PARK
RECREATION
1
CENTER
ETR 8 8
1
BIBB COUNTY
19
6'-4"
1 15
9
RECREATION
1
DEPARTMENT
8
7 7
19
EC 11 19 815 N MACON PARK DR
6
MACON, GA 31210
8'-1 1/4"
10
12 12
10'-0"
9
1
REVISIONS
# DATE DESCRIPTION
2'-8 1/8"
1 1 6
1
9 ETR
2'-8" 3'-4" 1'-3 5/8" 6'-0"
ETR
47'-0 3/4"
9 21
ETR ETR
9
1
8
ETR
EB
2.5
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
Checked By: CG
5/16/2016 4:08:09 PM
Sheet Number:
1
DEMOLITION FLOOR PLAN
3/16" = 1'-0" AD-1
WALL TYPE (SEE A4-1) WALL TYPE MODIFIER FIRE RATING WALL HATCH PATTERN LEGEND
STUD/CMU WIDTH
WALL TYPE MODIFIER A. 5/8" GYP BD EACH SIDE (NO SAB: STC 45 / WITH SAB: STC 49) 0 NOT RATED PARTITION TO RESIST THE
B. 5/8" GYP BD EACH SIDE UL# U465, GA FILE NO: WP1200 (NO S PARTITION TO RESIST THE PASSAGE OF SMOKE PASSAGE OF SMOKE
FIRE RATING
SAB: STC 45 / WITH SAB: STC 49) B 1 HOUR RATED SMOKE BARRIER
C. (2) LAYERS 5/8" GYP BD EACH SIDE UL# U411, GA FILE NO: C 2 HOUR RATED SMOKE BARRIER 1 HOUR RATED FIRE
WP1548 (NO SAB: STC 50 / WITH SAB: STC 54) 1 1 HOUR RATED FIRE BARRIER BARRIER
A2F3 D. (1) LAYER 1" GYP BD SHAFT SIDE, 2 LAYERS 1/2" GYP BD 2 2 HOUR RATED FIRE BARRIER / FIRE WALL 1 HOUR RATED SMOKE
OTHER SIDE UL# U438, GA FILE NO: WP 7095 (NO SAB: STC 45 / 3 3 HOUR RATED FIRE WALL BARRIER
WITH SAB: STC 49) 4 4 HOUR RATED FIRE WALL NON RATED
E. (1) LAYER 5/8" GYP BD EXPOSED SIDE ONLY (NO SAB: STC 45 / SYMBOL DESIGNATION MASONRY
# STUD WIDTH CMU WIDTH
WITH SAB: STC 49)
1 1 5/8" NON RATED MASONRY
F. NO SHEATHING FOR WALL TYPES INDICATED TO RECEIVE SOUND
2 2 1/2" STACKED WALL - CMU BASE &
G. 7/8" HAT CHANNELS W/ 5/8" GYP BD EACH SIDE ATTENUATION, EXTEND SOUND ATTENUATION TO FULL
3 3 5/8" GYP FURRING WALL TOP
H. 7/8" HAT CHANNELS W/ 5/8" GYP BD ONE SIDE ONLY HEIGHT OF WALL UNLESS OTHERWISE INDICATED. REFER
4 3 5/8"
I. NOT USED TO INDIVIDUAL WALL TYPE MODIFIER FOR STC RATINGS.
6 6" 5 5/8"
J. (1) LAYER 5/8" GYP BD EXPOSED SIDE ONLY. TEMPORARY
8 8" 7 5/8" X#X#
INFECTION CONTROL WALL SEAL TO FLOOR AND DECK. X#X#
12 11 5/8"
K. DOUBLE SIDED FURRING WALL - (1) LAYER 5/8" GYP BD
EXPOSED SIDE ONLY OVER TWO LAYERS OF 2 1/2" METAL
FRAMING, GYP BD TO BE FLUSH W/ CMU WITH SOUND NO SOUND
ATTENUATION ATTENUATION
163'-10 5/8"
E1
1'-2 7/8"
E2 E3 E4 E5 E6 E7
VEST.
EF SHOWERS M
11 5/8"
SHOWERS F
TLT F
TLT M
JAN.
ED
VEST.
35'-0" 35'-0"
11'-9"
RENOVATION
7
5/
8"
OFC.
& ADDITION
45'-0"
AK
TO NORTH
MACON
16'-6 1/2"
STORAGE KILNS
11 5/8" 70'-0" 11 5/8" 14'-0" 7 5/8" 38'-0" 7 5/8" 12'-0" 10'-7 1/8" 7 5/8" 12'-4 5/8" 1'-2 1/4"
PARK
OFC. 7 5/8" RECREATION
CENTER
33'-1 1/2"
GAME AREA
7 5/8"
7 5/8" 36'-3" 1'-2 1/4" BIBB COUNTY
RECREATION
102'-0"
GYMNASIUM
CRAFT
14'-1 1/2"
DEPARTMENT
64'-5 7/8"
EQUIP.
7 5/8"
EC
815 N MACON PARK DR
MACON, GA 31210
6'-4"
6'-4"
38'-0" 6'-4 5/8" 31'-8 1/4" VEST.
RECEPT.
7 5/8"
REVISIONS
# DATE DESCRIPTION
7 5/8"
KITCHEN
CORR.
12'-5 3/8"
11 5/8" 19'-0 3/8" 7 5/8" 8'-11 5/8" 7 5/8" 41'-1 1/4" 7 5/8" 18'-6 1/8" 1'-2 1/4"
45'-0"
19'-0 3/8"
10'-11 3/4"
25'-0 3/8"
VENDING
MTG ROOM
7 5/8"
3'-7 1/4"
7 5/8"
7 5/8"
VEST.
10'-1 1/2"
ALCOVE
STORAGE ELEC.
7'-6 3/8"
7 5/8"
5'-9 3/4"
PANTRY
1'-2 1/4"
1'-2 1/4"
EB
CONSTRUCTION DOCUMENTS
2.5 Date: 05/16/2016
C1
12'-6 3/8"
Drawn By: SP
Checked By: CG
5/16/2016 4:07:14 PM
Sheet Number:
1
FLOOR PLAN - EXISTING CONDITIONS
3/16" = 1'-0"
SCALE: 1/8" = 1'-0"
4'-0"
4'-0"
3 3 5/8" ATTENUATION, EXTEND SOUND ATTENUATION TO FULL GYP FURRING WALL TOP 2 2 STRUCTURAL DRAWINGS
H. 7/8" HAT CHANNELS W/ 5/8" GYP BD ONE SIDE ONLY HEIGHT OF WALL UNLESS OTHERWISE INDICATED. REFER
4 3 5/8" 5 NEW FCU & 4" CONCRETE HOUSEKEEPING PAD
I. NOT USED TO INDIVIDUAL WALL TYPE MODIFIER FOR STC RATINGS.
6 6" 5 5/8"
J. (1) LAYER 5/8" GYP BD EXPOSED SIDE ONLY. TEMPORARY 1 F04 F04 F04 1
8 8" 7 5/8" X#X#
INFECTION CONTROL WALL SEAL TO FLOOR AND DECK. X#X#
12 11 5/8" A3-1 A3-1
K. DOUBLE SIDED FURRING WALL - (1) LAYER 5/8" GYP BD F04 F04 F04 F04 F04 F04
19'-5 1/8"
EXPOSED SIDE ONLY OVER TWO LAYERS OF 2 1/2" METAL 2
WITH SOUND NO SOUND F05 F05 F05
FRAMING, GYP BD TO BE FLUSH W/ CMU
7'-4"
7'-4"
A3-2
ATTENUATION ATTENUATION 2 F04 F04 F04 F04 F04 F04 2 2
W1 F04 F04 F04 A3-2
F04 F04
19'-5 1/8"
LEGEND - WALL TYPES W1
1 1/2" = 1'-0" F04 F04 F04 F04
1
F05 38'-1 3/4" F05
3'-11 3/8"
1 A3-4
28'-2 1/4"
F04 F04 8 F04 F04
A3-4 1
F04 7 A5-3 9 F04 A1-2
MP ROOM 0'-0" PROJ TOS
28'-2 1/4"
119 10
397'-0" +/- FFE
3'-4"
13'-2 1/4"
119B
2
1
7 5/8"
A3-3
A3-3
7 5/8"
MB-1
119A 120 3'-4"
2'-0"
A2-1
9'-6 7/8"
7'-5 7/8"
3
STORAGE
7 5/8"
7"
E1 E2 2
6'-0" 7 5/8" 120
5
7 5/8" 9'-11" 3 5/8" 6 DS E6
A3-3
3'-4"
9'-5 1/4" 10'-4 1/8" A4-1
101 3 5/8"
4"
EG
SHOWERS F A5-319
122
25'-1 7/8"
EF FD
SHOWERS M
124
TLT F
16'-4 3/4"
121
3'-7 5/8"
STORAGE 3 TLT M
129 3 3 5/8" 123
3
E7
4 129 3 3
7 5/8"
VEST.
FEC 125
7'-3 5/8"
2'-0" 6'-0" 6'-0"
A5-1
3 6'-0" 3'-4" 3'-4" 5'-9 3/4"
125A
RENOVATION
R1 R1 E8F0 112B
FEC & ADDITION
FABRIC TO BE CF STINSON FENESTRA PIMENTO ON SEAT BACKS AND SILICA 70905 BISTRO ON SEATS
7 5/8"
F03
TO NORTH
E8F0
1
MACON
PARK
F04 F04 F04 F04 AK
12'-8"
126
F04 F04
F01 F03
E8F0 F04 F04
KILNS
RECREATION
F04 F04 F04 F04
GATHERING AREA
105 F04
F05
F04 F04
F05
F04
STORAGE
113
115
CENTER
F04 F04
6'-8"
OFC. 2 113
36'-0 5/8"
116 MP ROOM
A5-1 1 F02 1 A5-2 3 112
MB-1
4
F04 F04
BIBB COUNTY
F01
F04
F05
F04 F04
F05
F04
RECREATION
F04 F04 F04 F04 DEPARTMENT
F01 F04 F04
7 5/8" 28'-1 1/4" 7 5/8" 30'-1 7/8"
15'-5 3/8"
GYMNASIUM E8F0
ALTERNATE NO. 7:
EQUIP. F04 F04 CRAFT
127 4 128
128 114
F02 F04 F04 F04 F04
E8F0
F05 F05 815 N MACON PARK DR
7 F04 F04 F04 F04 MACON, GA 31210
A4-1 F04 F04
E8F0
F01 R1 1 R1
F03
7 5/8"
EC
7 5/8"
112A
6'-6"
2 VEST.
6 F06 111
A5-1
10'-0"
A5-3 5
104C 3 A5-3
4
RECEPT.
1'-4"
104
A2-1 2
IT-1 2'-0"
6'-0"
104A R1
CORR.
2 R1 101
2'-8" 3'-4" 1'-3 5/8" A5-36'-0" 1'-4"
KITCHEN
TC-01 108
FE
TROPHY CASE
103
1 A5-3 MTG ROOM
106
TC-01
VEST.
100
CONSTRUCTION DOCUMENTS
PANTRY
109 Date: 05/16/2016
5/16/2016 4:07:17 PM
C2 Sheet Number:
A1-1
NORTH
7 5/8"
7 5/8"
7 5/8"
TOILET ACCESSORY T24 36" SHOWER ROD & CURTAIN 1 CF, CI 120
2'-0"
3'-0"
1'-4"
T1 T4
T10
7 5/8"
FD T11
9'-6 7/8"
4'-4"
T3
7'-5 7/8"
120 T11
T17 T3 3'-4"
7 5/8" 7'-5 1/4" 2'-0" 7 5/8" 9'-11" 3 5/8" 3 5/8" 10'-4 1/8"
KEYNOTES - NEW WORK - FLOOR PLANS TOILET ACCESSORIES BY ROOM
6
3'-1 7/8"
NO. DESCRIPTION ROOM T17 7" T21 A4-1
DS
NO. ROOM NAME TYPE MARK DESCRIPTION COUNT O,C / C,C / O,O
T10
1 EXISTING COLUMN TO REMAIN, ENCLOSE WITHIN CMU CELLS T20 T11
2 PROVIDE METAL INTERIOR WINDOW BLINDS 121
121 TLT F T1 18" VERTICAL GRAB BAR 1 CF, CI
15'-6"
STRUCTURAL DRAWINGS T20 T20
T11
3 5/8"
121 TLT F T10 TOILET PAPER DISPENSER 6 CF, CI SHOWERS F
5 NEW FCU & 4" CONCRETE HOUSEKEEPING PAD 122
121 TLT F T11 TOILET SEAT COVER DISPENSER 6 CF, CI A5-319
121 TLT F T15 24" x 36" ADA HT. MIRROR 2 CF, CI T22 SHOWERS M
T24
121 TLT F T17 SANITARY NAPKIN DISPOSAL 6 CF, CI NEW FD 124
T17 EXG FD
3'-3"
3'-3"
121 TLT F T20 34x60 ADA TOILET PARTITION 9 CF, CI
121 TLT F T21 60x96 ADA TOILET PARTITION 1 CF, CI EF 15 T10
122
14A5-316
13
T20 T11
18A5-3 EXG FD EXG FD RENOVATION
3 5/8"
T16
122 SHOWERS F T16 TOWEL HOOK 1 CF, CI
1'-3"
122 SHOWERS F T22 ADA ACRYLIC SHOWER SEAT & SHOWER GRAB BAR,
COORDINATE SLAB RECESS REQUIREMENTS W/
PRODUCT SUBMITTALS
1 CF, CI
T10
T17
T23
& ADDITION
T20
TO NORTH
122 SHOWERS F T24 36" SHOWER ROD & CURTAIN 1 CF, CI T11
7 5/8" 3'-0" 3 5/8"
123
123 TLT M T1 18" VERTICAL GRAB BAR 1 CF, CI
123
123
123
TLT M
TLT M
TLT M
T3
T4
T7
36" GRAB BAR
42" GRAB BAR
SOAP DISPENSER
1
1
1
CF, CI
CF, CI
OF, OI
T6
TLT F
121
A5-312
T20
T10
T17
T11
3
MACON
123 TLT M T10 TOILET PAPER DISPENSER 2 CF, CI 3
PARK
11'-5"
123 TLT M T11 TOILET SEAT COVER DISPENSER 2 CF, CI
8'-11 3/4"
123 TLT M T15 24" x 36" ADA HT. MIRROR 2 CF, CI
RECREATION
123 TLT M T20 34x60 ADA TOILET PARTITION 4 CF, CI 3
3
123 TLT M T21 60x96 ADA TOILET PARTITION 1 CF, CI TLT M
123 TLT M T23 URINAL SCREEN 1 CF, CI 123
3 3
3
JAN.
118
3
CENTER
3
3
ED # 3
BIBB COUNTY
3
2
A3-1
CORR.
101
RECREATION
NORTH
DEPARTMENT
FLOOR PLAN - ENLARGED TOILETS
1
3/8" = 1'-0"
REVISIONS
60" MIN FOR
LATCH APPROACH
24" MAX
CLEAR FLOOR
4" MAX
36"
DISPENSER DISPENSER OPTIONAL
30" CONTROL
PRIVACY
48"
42"
42"
56" MIN
SCREEN WALL EQ EQ
7"
7"
4'-0"
48"
CLEAR FLOOR
2'-0" MAX
SPACE
17"-25"
12"
CLEAR FLOOR
36"
BAR SPACE
6" 36" 6" 36" 2'-6"
ADA TOILET STALL- PLAN ADA TOILET ROOM WITH ADA URINAL - PLAN ADA TRANSFER ADA DRINKING
ADJACENT LAVATORY - PLAN SHOWER - PLAN 36" FOUNTAIN - PLAN
EQ EQ
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
CURTAIN ROD
BAR DISPENSER
72"
WASTE
Project Number: 2016-08
3'-6"
3'-6"
NAPKIN
REFLECTIVE
3'-4" MAX TO
REFLECTIVE
3'-4" MAX TO
4'-0" MAX
SHOWER RECEPTACLE
SURFACE
9" SURFACE
39" - 41"
DISPOSAL
48"
SEAT
34" MAX
34" MAX
3'-0" MAX
3'-0" MAX
MAX4'-0" MAX
H L
40"
TOILET TISSUE
2'-3" MIN
8" 8"
27" MIN
27" MIN
Sheet Name:
33"
33"
33"
33"
DISPENSER
19" MIN
17"-19"
MIN MIN
ENLARGED FLOOR
18"
12"
MIN
MIN
MAX
1'-5"
1'-5"
9"
1'-3"
1'-3"
15" 18"
WHEEL CHAIR 36" MIN CLEAR
6" MAX 11" MIN MIN GUARD 6" MAX 11" MIN
ACCESSORIES
5/16/2016 4:07:21 PM
ADA LAVATORY - SIDE ADA LAVATORY - FRONT ADA TOILET - SIDE ADA TOILET - FRONT ADA TRANSFER ADA TRANSFER ADA DRINKING ADA DRINKING MISC. ACCESSORIES Sheet Number:
ADA URINAL - FRONT ADA URINAL - SIDE SHOWER - FRONT SHOWER - CONTROL FOUNTAIN - FRONT FOUNTAIN - SIDE
A1-2
WALL
LEGEND - ADA ACCESSIBLE FIXTURES
3/8" = 1'-0"
E3 E4 E3 E4 E3 E4
3" / 12"
2'-6" 9'-0 5/8"
EB FV EXG SIDEWALK EB EB
9'-4" EXISTING NON-VENTED EXISTING STANDING
3 METAL SOFFIT TO SEAM ROOFING
3'-0"
DOWNSPOUT MOUNTED A4-1 EXG DS TO REMAIN 10'-6" EXG +/-
4'-0"
REMAIN SYSTEM TO REMAIN
TO FACE OF COLUMN, 2.5 2.5 EXISTING GUTTER TO
2.5 EXISTING GUTTER TO
PAINT BLACK TO MATCH
EXISTING GUTTERS REMAIN REMAIN
2'-0"
2'-0"
1'-0"
C1 C1 EXTENTS OF ROOF
ABOVE EXISTING ROOF
C1
CONC. SPLASHBLOCK
6 6 6
A1-3 A1-3 A1-3
DOWNSPOUT MOUNTED
TO FACE OF COLUMN,
8'-10"
8'-10"
NEW CONCRETE BENCH NEW ENTRANCE CANOPY STL. COLUMN, PAINT PAINT BLACK TO MATCH
ROOF EDGE LINES SW 7558 MEDICI IVORY TPO ROOFING EXISTING GUTTERS TPO ROOFING MEMBRANE
(ABOVE) MEMBRANE OVER 2" OVER 2" RIGID INSULATION,
RIGID INSULATION, 3/4" 3/4" PLYWOOD, & 3" METAL
EA EA PLYWOOD, & 3" METAL EA ROOF DECK PAINTED SW
ROOF DECK PAINTED 7558 MEDICI IVORY
SW 7558 MEDICI IVORY
19'-8"
21'-8"
C2 C2 C2 2" / 12"
STL. COLUMN, PAINT SW 7558 MEDICI IVORY EXISTING CONCRETE 2" / 12" TAPERED STL. TAPERED STL. BEAM,
BEAM, PAINT SW PREFINISHED SM GUTTER, PAINT SW 7558
SLOPE
SIDEWALK TO REMAIN.
7558 MEDICI IVORY COLOR TO MATCH EXISTING MEDICI IVORY
3/4" CHAMFER AROUND TOP PATCH AS REQUIRED FOR PREFINISHED SM GUTTER,
PERIMETER OF CONCRETE GUTTERS
NEW CANOPY FOOTING COLOR TO MATCH
8'-10"
8'-10"
BENCH INSTALLATION EXISTING GUTTERS
11'-6 1/8" T.O. TPO 13'-5 1/2" T.O. TPO
12'-11 1/2" B.O. DECK
SKATEBOARD STOPS @ 36" MAX, BASIS- 11'-0" B.O. DECK
OF-DESIGN: BARRETT ROBINSON FIXED
ANGLE SKATE DETERRENTS - FA135,
CLEAR ANODIZE FINISH SURFACE 4 5
MOUNTED SIM
A1-3 5 A1-3
LIGHTING FIXTURE
C3 C3 C3
1'-0"
A1-3
2'-0"
11'-8 1/2" 1'-0"
NORTH
MACON
TPO SEAM FLASHING TPO ROOFING
MEMBRANE OVER 2"
6x4x3/8 STL. RIGID INSULATION,
DECK ANGLE 3/4" PLYWOOD, & 3"
PARK
METAL ROOF DECK
MP DRIP EDGE
CONTINUOUS BEAD OF TPO SEALANT
ATTACH SHEATHING GRAVEL
2x BLOCKING TPO TOP SHEET STOP
RECREATION
FROM UNDERSIDE
OF ROOF DECK MP DRIP EDGE
TPO SEALANT TPO SEAM FLASHING
CONT. CLEAT 6x4x3/8 STL.
E4 TPO ROOFING DECK ANGLE
11'-8 5/8"
GUTTER &
MEMBRANE OVER 2"
RIGID INSULATION,
3/4" PLYWOOD, & 3"
METAL ROOF DECK
2x BLOCKING
CONT. CLEAT
CENTER
FASTENER ROOF DECK,
TPO ROOFING MEMBRANE OVER 2"
RIGID INSULATION, 3/4" PLYWOOD, & 2.5 STRAPS PAINTED
FASTENERS FOR ATTACH ROOF SHEATHING
3" METAL ROOF DECK PAINTED SW CANOPY FRAME,
MEMBRANE, PROVIDE FROM UNDERSIDE
7558 MEDICI IVORY REFER TO
LENGTH THAT DOES
STRUCTURAL,
PAINTED
NOT PENETRATE ROOF
MEMBRANE
CANOPY FRAME,
SEE STRUCTURAL,
BIBB COUNTY
PREFINISHED SM GUTTER,
COLOR TO MATCH EXISTING
GUTTERS
PAINTED
RECREATION
DEPARTMENT
11'-0"
2 - LOW ROOF CANOPY ROOF AT GUTTER CANOPY ROOF EDGE
4 5
10'-10 3/8" 3" = 1'-0" 3" = 1'-0"
SM DRIP EDGE & ROOF
BLOCKING AROUND PERIMETER
TAPERED STL. BEAM, PAINT SW 7558 MEDICI IVORY
815 N MACON PARK DR
STL. COLUMN, PAINT SW 7558 MEDICI IVORY
MACON, GA 31210
REVISIONS
# DATE DESCRIPTION
DOWNSPOUT MOUNTED TO
FACE OF COLUMN, PAINT
BLACK TO MATCH EXISTING
GUTTERS
CONSTRUCTION DOCUMENTS
NEW PREMOLDED
EXPANSION JOINT Date: 05/16/2016
FILLER
1'-6"
5/16/2016 4:07:23 PM
Sheet Number:
CANOPY SECTION 1
A1-3
6
3/4" = 1'-0"
ROOF TYPE TO
MATCH EXISTING
EAVE FLASHING WITH 4" SECURE TO
END LAPS WITH CONT. FRAMING AT
SEALANT 30" OC
SUB FLASHING. PROVIDE
5/8" PLYWOOD SHEATHING 4" END LAPS WITH SEALANT ROOF PANEL TO FOLD
RIDGE CAP AT DRIP FLASHING.
CONTINUOUS CLEAT ROOF TYPE TO MATCH
FASTEN PER MANU. EXISTING ON 30# FELT LOW PROFILE 5/8" RIDGE GUTTER STRAP
DIRECTIONS CONTINUOUS CLEAT VENT MATERIAL BY COR-A-VENT AT 30" OC
ROOF PANEL TO FOLD 5/8" PLYWOOD SHEATHING EACH SIDE OR EQUAL 5/8" PLYWOOD SHEATHING
ROOF TYPE TO AT DRIP FLASHING.
MATCH EXISTING RIDGE
DASHED LINE:
FLASHING
1"
MATCH EXISTING
BREAK METAL ON 2x PT PANEL LEGS
6"
6"
FLASHING
SUBFRAMING SEE DETAIL THIS
5"
1'-1"
5/8" PLYWOOD
SHEATHING
PT 2X8 RIDGE CAP BREAK METAL ON 2x PT
SUBFRAMING
CONTINUOUS
CLEAT
.
6"
/2" MI N CONTINUOUS
19 1 CLEAT
ZEE PURLIN
VALLEY FLASHING
NOTE:
DIMENSIONS AND PROFILE SHOWN IS FOR GENERAL REFERENCE
ONLY. NEW BOXED GUTTER IS TO MATCH EXISTING IN MATERIALS, RIDGE VENT ROOF EDGE DETAIL
GAUGE, COLOR AND PROFILE.
5 6
3" = 1'-0" 3" = 1'-0" EAVE FLASHING
CONTINUOUS CLEAT
SUB - FLASHING
DRIP FLASHING
4 1 2
DASHED LINE: OUTSIDE
2'-0"
3'-6" A3-2 A3-1 3'-6"
CURB MATERIAL A1-9 FACE OF WALL BELOW
SEE MECHANICAL
MATCH EXISTING
FOR TYPE AND DIMS.
MATCH EXISTING
ANGLE FLASHING
H DS DS
ANGLE FLASHING
ZEE CLIPS 1 1
FLASHING
L
COUNTER FLASHING ICA MIN
. A3-1 A3-1
EC HAN 12" CONT. BEAD OF STANDING SEAM ROOFING SYSTEM
SECURE TO ZEE 2
SE EM SEALANT BETWEEN OVER ROOFING MEMBRANE, 5/8" NEW VENTED SOFFIT (BELOW)
CLOSURE A3-2 2
FELT AND FLASHING PLYWOOD DECK, VINYL FACED BATT
INSULATION & PRE-ENGINEERED STEEL
RENOVATION
DASHED LINE: NEW VENTED SOFFIT (BELOW) 6
TO MATCH 6
30# FELT MODIFY EXISTING GUTTER TO
EXISTING A1-9
MODIFY EXISTING GUTTER TO A1-9 TIE INTO NEW GUTTER
CONT. CLEAT TIE INTO NEW GUTTER
E1 EXISTING NON-VENTED SOFFIT (BELOW) E7
DASHED LINE:
30# FELT EXISTING NON-VENTED SOFFIT (BELOW) & ADDITION
5/8" PLYWOOD
SHEATHING
EG 3 TYP. 3
TO NORTH
EF
A1-9 A1-9
MACON
"
8"8
COUNTER
FLASHING ZEE CLOSURE
PARK
RECREATION
EY
VA
LL
LL
VA
EY
ANGLE
FLASHING
CENTER
8"8
CONTINUOUS ED
"
CLEAT
DASHED LINE:
VALLEY FLASHING 3" / 12"
7
CURB DETAIL
3" = 1'-0"
BIBB COUNTY
RECREATION
DEPARTMENT
FLEXIBLE RUBBER BOOT
FLASHING ROOF PIPE EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN
PENETRATION TO BE IN
SET BOOT IN CONT. BEAD OF 4" MAX.
PAN OF PANEL ONLY
CAULK. USE FASTENERS
SPECIFIED BY BOOT MANU.
CONT. CAULK ON
CAULK FASTENER HEADS
STAINLESS STEEL 815 N MACON PARK DR
HOSE CLAMP
MACON, GA 31210
2" / 12"
3" / 12"
ROOF TYPE
TO MATCH
EXISTING REVISIONS
3" / 12"
4 A2-1 # DATE DESCRIPTION
EXISTING ROOF TO REMAIN
AFTER CUTTING
ROOF PANEL
30 # FELT ON
FOLD EDGES UP
AS SHOWN AND 5/8" PLYWOOD EC
CAULK SHEATHING
3" / 12"
EXISTING ROOF TO REMAIN
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
EB
2.5 Drawn By: BEJ/SP
C1 DS
6 1 Checked By: CG
NEW PREFINISHED SM GUTTER
A1-3 A2-1
5/16/2016 4:07:25 PM
& 3" METAL ROOF DECK
C3 2
Sheet Number:
A3-1
A1-9
NORTH
SCALE: 1/8" = 1'-0"
ROOF PLAN
1
1/8" = 1'-0"
0' 4' 8' 16' 32'
EXTERIOR MATERIALS LEGEND
CMU-1
STACKED BOND
COLOR 1 (TAN), MATCH EXISTING:
EXISTING COLOR TO BE
E1 E2 E3 2.5 E4 E5 E6 E7 DETERMINED
CMU-2
RUNNING BOND
COLOR 2 (WHITE), EXISTING:
EXISTING COLOR TO BE DETERMINED
CMU-3
RUNNING BOND
2 COLOR 2 (TAN), EXISTING:
EXISTING COLOR TO BE DETERMINED
A3-1
PREFINISHED SM CONCRETE
CAST-IN-PLACE OR CAST STONE
3 - GYM ROOF
25'-0"
1'-0"
CMU-1 CMU-3
METAL WALL & ROOF PANELS
STANDING SEAM PANEL
AEP SPAN "COLONIAL RED" OR EQUAL
TO MATCH EXISTING
CMU-2 CMU-3
CMU-1 CMU-2
1 - LEVEL 1
0"
H EG EF ED EC EB C1 EA C2 C3
3 - GYM ROOF
NEW EXG 25'-0"
1 2 1 2
A3-1 A3-2 A3-4 A3-3
EXG NEW
LTG
10'-10 3/8"
& ADDITION
W1
FCU
101
EXG DS EXG DS EXG DS
#
TO NORTH
1 - LEVEL 1
0" MACON
2
WEST OVERALL ELEVATION
1/8" = 1'-0" PARK
RECREATION
E7 E6 6 E5 E4 E3 2 E2 E1 CENTER
1 2
BIBB COUNTY
A3-2 A3-1
RECREATION
DEPARTMENT
3 - GYM ROOF
25'-0"
METAL ROOF PANEL
DS
1 - LEVEL 1
0"
C3 C2 EA C1 EB EC ED EF EG H
EXTERIOR GLAZING
EXG NEW
CONSTRUCTION DOCUMENTS
3 - GYM ROOF Date: 05/16/2016
PREFINISHED SM
25'-0"
6
Checked By: CG
NEW ENTRANCE CANOPY A1-3 METAL ROOF PANEL
METAL ROOF PANEL Project Number: 2016-08
METAL ROOF PANEL
2 - LOW ROOF
GUTTER & DOWNSPOUT 10'-10 3/8" Sheet Name:
LTG
EXTERIOR ELEVATIONS
W1
# 125B 119B
5/16/2016 4:07:30 PM
DS DS
1 - LEVEL 1
Sheet Number:
0"
4
EAST OVERALL ELEVATION
1/8" = 1'-0"
A2-1
DOOR SCHEDULE
DOOR LEAF DOOR FRAME
EXTERIOR DOOR HEAD FLASHING EXTERIOR DOOR JAMB FLASHING DOOR DOOR DOOR FRAME FRAME
NO FROM ROOM TO ROOM WIDTH HT ELEV MATERIAL FINISH GLAZING ELEV FRAME MATERIAL FINISH HEAD JAMB RATING COMMENTS
EXTERIOR
SECOND LAYER OF 4" 1/8"
WATER-RESISTIVE MATERIAL 101 CORR. 3'-0" 7'-0" B HM P-_ G-01 3, ETR HM P-_ 3/A2-2 4/A2-2 --- SEE SPEC SECTION 01 2300, ALTERNATE NO. 1
BARRIER 1/4" 104A RECEPT. CORR. 3'-0" 7'-0" B HM P-_ G-01 2 HM P-_ 1/A2-2 2/A2-2 ---
104C 7'-4" 8'-8 1/2"
...4'-8"... D ROLLING STL. PER MFR. --- --- STL. FACE MOUNT PER MFR. 11/A2-2 12/A2-2 ---
SELF- 112A CORR. MP ROOM 3'-0" 7'-0" B HM P-_ G-01 2 HM P-_ 1/A2-2 2/A2-2 ---
2"
ADHERING SEALANT &
EXTERIOR
MATERIAL
MEMBRANE BACKER ROD 112B MP ROOM CORR. 3'-0" 7'-0" B HM P-_ G-01 2 HM P-_ 1/A2-2 2/A2-2 ---
1 7/8"
113 STORAGE MP ROOM 6'-4" 7'-0" A HM P-_ --- 2 HM P-_ 1/A2-2 2/A2-2 ---
4" 119A CORR. MP ROOM 3'-0" 7'-0" B HM P-_ G-01 2 HM P-_ 1/A2-2 2/A2-2 ---
119B MP ROOM 3'-0" 7'-0" B HM P-_ G-01 3, ETR HM P-_ 3/A2-2 4/A2-2 --- SEE SPEC SECTION 01 2300, ALTERNATE NO. 1
METAL 120 STORAGE MP ROOM 6'-4" 7'-0" A HM P-_ --- 2 HM P-_ 1/A2-2 2/A2-2 ---
4 7/8"
OPENING 125A CORR. VEST. 6'-0" 7'-0" B HM P-_ G-01 3, ETR HM P-_ 1/A2-2 2/A2-2 --- SEE SPEC SECTION 01 2300, ALTERNATE NO. 1
FLASHING AS SECOND LAYER OF 125B VEST. 6'-0" 7'-0" B HM P-_ G-01 3, ETR HM P-_ 3/A2-2 4/A2-2 --- SEE SPEC SECTION 01 2300, ALTERNATE NO. 1
WATER-RESISTIVE
3"
SPECIFIED METAL 128 EQUIP. GYMNASIUM 6'-0" 7'-0" A HM P-_ --- 2 HM P-_ 1/A2-2 2/A2-2 ---
BARRIER OPENING 129 STORAGE GYMNASIUM 6'-0" 7'-0" A HM P-_ --- 2 HM P-_ 1/A2-2 2/A2-2 ---
3"
LINE OF SHEATHING & FLASHING AS
SELF-
WATER-RESISTIVE SPECIFIED
ADHERING
BARRIER MEMBRANE
LINE OF SHEATHING &
3" 2" WATER-RESISTIVE
BARRIER
5" WATER-RESISTIVE BARRIER
4"
STL. LINTEL PER, SEE
OVERHEAD COILING H.M. FRAME EXTERIOR DOOR STRUCTURAL
4"
DOOR HOUSING DOOR OPENING FLASHING
5/8"
GROUT SOLID AS SPECIFIED PROVIDE 3"
COILING DOOR SLATS
5 3/4" DOG LEG TO INSERT INTO
5/8"
JAMB FLASHING
INTERIOR DOOR
DOOR HEAD - COILING INTERIOR DOOR HEAD - MASONRY DOOR HEAD - CMU
11 1 3
3" = 1'-0" 3" = 1'-0" 3" = 1'-0"
1"
R 5/8" 2" CMU WALL, LATERAL
1/2"
1 15/16" VARIES 1 9/16"
ANCHOR AS FLEXIBLE FLASHING
REQ'D AT
RENOVATION
ANCHOR AS MEMBRANE TO WRAP
WALL TYPE
CMU WALL, LATERAL NEW AND
PER PLAN
REQ'D OVER WINDOW JAMB
PER PLAN
COURSING NOT SHOWN EXISTING FLASHING
FOR CLARITY WALLS
WATER-RESISTIVE BARRIER
1/2"
1/2" EXTERIOR DOOR
WALL MOUNTED
COILING DOOR GUIDE
INTERIOR DOOR SEALANT EA.
DOOR OPENING JAMB
FLASHING INSERT
SEALANT EA.
SIDE
2" AIR SPACE W/ CMU TIES
TO NORTH
6 1/4"
COILING DOOR,
SIDE VERTICAL LEG FROM SILL
MATERIAL PER DOOR CMU RETURN BLOCK @ JAMB,
SCHEDULE
COUNTER (BELOW),
SPOT GROUT @
JAMB ANCHORS
H.M. FRAME
OR HEAD FLASHING INTO
RECESSES
SEE ELEVATIONS FOR TYPE
30" AFF
COUNTERTOP (SEE ELEV
FOR MATERIAL & A5-3
FOR EDGE DETAILS
(BEYOND)
DOOR PER SCHEDULE
BIBB COUNTY
FULLY SET
RECREATION
1 1/2"
THRESHOLD IN DOOR THRESHOLD
(2) LAYERS 3/4" SOLID SEALANT
1/4" MAX.
PREMOLDED
1 1/4"
PLYWOOD SUPPORT @ P-
LAM COUNTERS ONLY EXP. JT. DEPARTMENT
24". CUT BLOCK @ SILL 2" CAST-IN-PLACE
SEE FLOOR PLAN CONCRETE SIDEWALK
2x BLOCKING
ANCHORED TO CAST-IN-PLACE
GROUT CONCRETE SLAB
WALL TYPE PER PLAN
COIL HEAD
PER MFR
SCHEDULE SCHEDULE SCHEDULE CMU HEADER HT
# DATE DESCRIPTION
• ALL NON-RATED DOORS TO BE GLAZED 4" 8" 8" 8"
WITH TYPE G-01 TEMPERED GLAZING
8"
(INSULATED AT EXTERIOR DOORS)
• ALL 1-HOUR RATED DOORS TO BE
4'-8"
WITH SAFETY FILM (FACTORY APPLIED)
25"
3'-2" UNO
3'-6"
42"
42"
2'-6"
DOOR
FINISH FLOOR ELEVATION = 0'-0" TYPE A: TYPE B: TYPE C: TYPE D:
FLUSH PANEL VISION-LITE 100 SQ IN. MAX HALF-LITE 1,296 SQ IN. MAX OVERHEAD COILING
SINGLE & DOUBLE LEAF SINGLE & DOUBLE LEAF SINGLE & DOUBLE LEAF DOOR
FACE MOUNTED FRAME
SCHEDULE SCHEDULE
CONSTRUCTION DOCUMENTS
2" SEE DOOR 2" 2" SEE DOOR 2" 2" 16" 2" SEE DOOR 2" 2" 16" 2" SEE DOOR 2"
4"
2"
2"
Drawn By: BEJ
Checked By: CG
VAR.
VAR.
SEE DOOR SCHEDULE
Sheet Name:
2"
2"
DOOR SCHEDULE &
32"
32"
DETAILS
FRAME
5/16/2016 4:07:33 PM
4"
4"
Sheet Number:
FINISH FLOOR ELEVATION = 0'-0" TYPE 1: TYPE 2: TYPE 3: TYPE 4: TYPE 5: TYPE 6:
HM FRAME HM FRAME HM FRAME HM FRAME HM FRAME HM FRAME
A2-2
SAFETY GLASS REQUIREMENTS
NOTE: NOT ALL CONDITIONS SHOWN BELOW ARE APPLICABLE TO THE SCOPE OF WORK.
FIRE-RATED
LAMINATED
TEMPERED
ANNEALED
SEAL INTERSECTIONS
BARRIER A - ACCEPTABLE
WITH LIQUID
WIRED
LAP OVER JAMB MEMBRANE (TYP) WINDOW SYSTEM NR - NOT RECOMMENDED
SELF- SEALANT &
EXTERIOR
MATERIAL
FLASHING AS SPECIFIED
2"
LAP OVER JAMB ADHERING BACKER ROD SAFETY NOT REQUIRED NP A NP NP A
1 7/8"
FLASHING MEMBRANE 4 1/4" 3/8" 6" SLOPED 5/8" FIRE-RATED
SAFETY REQUIRED NP NP NP NP A
4" SAFETY NOT REQUIRED A A A A NR
NON-FIRE-RATED
SAFETY REQUIRED NP NP A A NR
5/8"
NOTE: THE MAXIMUM AREA OF ANY SINGLE
7/
4 7/8"
8
METAL OPENING PANE OF WIRE GLASS IS 1,296 SQ IN.
"
FLASHING AS SECOND LAYER OF METAL METAL OPENING SAFETY GLAZING (SG) IS REQUIRED FOR
SPECIFIED WATER-RESISTIVE OPENING FLASHING AS SPECIFIED
BARRIER FLASHING WET AREAS CLOSE PROXIMITY TO DOORS
3"
CUT SILL CMU TO MATCH
3"
INSERT VERTICAL AS
TAB INTO SLOT LINE OF SHEATHING & SELF- SPECIFIED EXISTING FOR DRAINAGE
CREATED BY FOLD WATER-RESISTIVE ADHERING
IN JAMB FLASHING BARRIER MEMBRANE LINE OF SHEATHING &
PRIOR TO SG SG
INSTALLATION OF WATER-RESISTIVE
LINE OF SHEATHING & BARRIER
RUBBERIZED ASPHALT 3" 2" WATER-RESISTIVE SG
FLASHING -SEAL 1" RIGID INSULATION,
60"
BARRIER SG SG
INTERSECTIONS WITH 5" 2" AIR SPACE, & CMU
SG
LIQUID MEMBRANE STANDING SURFACE SG
(TYP) SG
ANY GLASS AROUND SAFETY GLASS IS TO BE SG
SG
THESE AREAS AT 60" USED FOR ALL DOORS SG
WINDOW FLASHING GENERAL NOTES
60"
OR LESS ABOVE THE AT HOT TUBS, SG
LAP OVER SILL 24
60"
SG "
FLASHING 1. PROVIDE 2" LAP DAMS AT ALL OPENINGS AND STANDING SURFACE IS WHIRLPOOLS, SAUNAS,
SG
TERMINATIONS. LAPS BETWEEN PIECES OF TO BE SAFETY GLASS STEAM ROOMS, BATH
SG
METAL FLASHING SHOULD BE FULLY BEDDED IN TUBS OR SHOWERS 24
"
SEALANT. REMOVE TO HEM FROM TOP PIECE OF
FLASHING @ LAPS
ALUMINUM WINDOW FLASHING GLAZED OPENINGS IN PARTITIONS
B
3" = 1'-0"
36"*
W IT
IES OND
36" ± 2"
36" ± 2"
3"
R
VA C 3" FLOOR WALKING FLOOR
18"*
18"*
SURFACE
25 FT.*
36"* 36"*
SOLDER 6"
GRADE
0.06”
ANODIZED SAFETY GLASS IS REQUIRED WHEN ALL OF SAFETY GLASS IS REQUIRED AT INTERIOR
ALUMINUM THE FOLLOWING CONDITIONS ARE PRESENT: LITE WHEN BOTTOM OF GLAZING < 18"
• TOP OF GLAZING > 36" AFF AFF
RUBBERIZED • AREA OF SINGLE PANE > 9 SF
ASPHALT • BOTTOM OF GLAZING < 18" AFF EXCEPTION:
FLASHING • WALKING SURFACE IS LOCATED INTERIOR LITE DOES NOT NEED
WITHIN 36" TO BE OF ONE OR BOTH SIDES
EXCEPTION:
VARIES WITH SAFETY GLASS IS REQUIRED FOR EXTERIOR
CONDITIONS GLASS DOES NOT NEED TO BE SAFETY GLASS
LITE EXCEPT WHEN THE BOTTOM OF THE
2" WHEN 1 1/2" SAFETY BAR IS INSTALLED WHERE
GLAZING IS > 25FT ABOVE GRADE
WALKING SURFACE IS WITHIN 36" OF GLASS
13
END DAM FLASHING
3" = 1'-0"
LEGEND - SAFETY GLAZING
1/4" = 1'-0"
RENOVATION
5 5/8"
& ADDITION
STOREFRONT SYSTEM F.O. FRAME OUTLINE OF TURNED UP
FLASHING BEYOND
INSULATION ADHESIVE
TO NORTH
WALL TYPE
PER PLAN
WALL TYPE
PARK
SHIM, SEALANT, AND CMU BOND BEAM HEADER, 10" H MORTAR NET
CMU BOND PREFINISHED LOUVER FINISHED FLOOR, BACKER ROD SIZE PER STRUCTURAL
BEAM PER SCHEDULE SS SUB SILL TURN ENDS
UP 1" MIN. AND SEAL SELF-ADHERING FLASHING
1/2" 4 7/8" 1/2" WINDOW SILL FLASHING 0'-0"
SEALANT EA.
SIDE
CMU
LOUVER
MOUNTING ANGLE
HEMMED DRIP EDGE OF SILL
FLASHING, BEND FLASHING
PREMOLDED EXPANSION
JOINT FILLER
SEALANT, BACKER ROD, &
24 GA. STAINLESS STEEL FLASHING
SET INTO A FULL CONTINUOUS BED
OF SEALANT. FABRICATE WITH MIN.
RECREATION
PER WINDOW
GROUT SOLID ANCHOR AS VAPOR BARRIER ON 5/8" & STEM WALL EXTERIOR BELOW-GRADE
REQ'D PLYWOOD SHEATHING ON 3 CONCRETE FACES STOREFRONT SYSTEM
5/8"
LAMINATED
RIGID INSULATION ON
SHEATHING ON GABLE
FLASHING BEYOND
STRUCTURAL
INSULATION ADHESIVE
5 5/8"
INTO RECESSES CMU RETURN @ JAMB, SEE
ELEVATIONS FOR TYPE
WINDOW FLASHING (BELOW)
SEALANT AND BACKER ROD
5 5/8"
CONSTRUCTION DOCUMENTS
OUTLINE OF TURNED UP
FLASHING BEYOND Date: 05/16/2016
STOREFRONT SYSTEM SEALANT, BACKER
ROD, & SHIM, EA SIDE
10 Drawn By: BEJ
WALL BEYOND
A2-3
7'-4" WINDOW SILL FLASHING
1
3'-8" 3'-8" 12'-0" SS SUB SILL TURN Checked By: CG
A2-3 ENDS UP 1" MIN. AND
6'-0" EQ EQ HEMMED DRIP EDGE OF SILL
SEAL
FLASHING, BEND FLASHING
2" Project Number: 2016-08
3" / 1 PAN UP BEHIND WINDOW
1'-6"
2 SYSTEM
4'-8"
3'-4"
L1
ITG ITG
A2-3 TG 3 SILL, SIZE PER 1" RIGID INSULATION WINDOW SCHEDULE &
A2-3 STRUCTURAL INSULATION ADHESIVE
DETAILS
3'-4"
5/16/2016 4:07:36 PM
LOUVER COLOR TO MATCH RED SHEET METAL TIES @ 24" OC
1 - LEVEL 1 1 - LEVEL 1 1 - LEVEL 1 CMU TO MATCH EXISTING
Sheet Number:
0" 0" 0"
W1
W1 - STOREFRONT SYSTEM
1/4" = 1'-0"
R1
R1 - HM INTERIOR RELITE
1/4" = 1'-0"
L1
L1 - GABLE LOUVER
1/4" = 1'-0"
12
WINDOW SILL - CMU
3" = 1'-0"
A2-3
2
A3-1
6 E5 E4 E3 2
STANDING SEAM ROOFING SYSTEM
2
OVER ROOFING MEMBRANE, 3/4"
PLYWOOD DECK, VINYL FACED BATT A3-2
INSULATION & PRE-ENGINEERED STEEL
ROOF TRUSSES
2 - LOW ROOF
10'-10 3/8"
2
A3-1
E/W SECTION 1
1
3/16" = 1'-0"
C3 C2 EA C1 EB EC ED EF EG H
3 - GYM ROOF
25'-0"
2 - LOW ROOF
MACON
A2K0
CMU TO MATCH EXISTING OVER 2"
E8F0 AIR SPACE, 1" RIGID INSULATION, &
STL. COLUMN, PAINT SW 7558 MEDICI IVORY 8" STRUCTURAL CMU
R1 R1
NEW CONCRETE BENCH W/
SKATEBOARD STOPS @ 36"
OC MAX
MTG ROOM
106 112A
MP ROOM
112
CORR.
101
JAN.
118
TLT F
121
MP ROOM
119 4" CONCRETE SLAB OVER 10 MIL.
VAPOR RETARDER & 4" #57 STONE
SUB BASE
PARK
1 - LEVEL 1
0"
RECREATION
1
CENTER
A3-1
N/S SECTION 1
2
3/16" = 1'-0" BIBB COUNTY
RECREATION
DEPARTMENT
REVISIONS
# DATE DESCRIPTION
CONSTRUCTION DOCUMENTS
Date: 05/16/2016
Checked By: CG
Sheet Name:
BUILDING SECTIONS
5/16/2016 4:07:38 PM
Sheet Number:
A3-1
5
H A1-9
RIDGE AT
METAL ROOF
STANDING SEAM METAL
ROOF TO MATCH
EXISTING ON 30# FELT
ON 5/8" PLYWOOD
DECK
METAL FRAMING
4
A1-9
2
6
TOP AND BOTTOM
CHORDS OF METAL
TRUSS
TOP AND BOTTOM
VARIES
NON VENTED CHORDS AT NEW
METAL SOFFIT METAL TRUSS TO BE
2'-0" ON HAT CHANNELS STANDING SEAM ROOF TO MATCH 6"
EXISTING ON 30# BUILDING FELT
ON 5/8" PLYWOOD ON METAL
METAL WALL PANELS TRUSSES AT 2'-0" OC
ON VAPOR BARRIER
ON 5/8" PLYWOOD
SHEATHING ON 3 5/8" ED
E QUIR
METAL STUDS AS R
SECURE METAL FRAMING TO LOW
TRUSS EXTENSION AS SHOWN AIR F
RIGID INSULATION
ON SHEATHING ON
GABLE END TRUSS
TRUSS
10'-11"
BEARING
TRUSS
10'-11"
BEARING
DROPPED GABLE
END METAL SECURE GYP BOARD
TRUSS TO TRUSS TO KEEP BATT INSULATION
6 INSULATION OUT OF SUPPORTED ON
A1-9 AIR FLOW TYVEK
EXPANSION BOLT
AT (2) PT 2x AT
MATCH EXISTING
BOND BEAM METAL TRUSS AT 2'-0" OC
SECURE TO PT 2x WITH LAY - IN ACOUSTICAL TILE
PT 2x AS REQ'D CLIP ANGLE.
FOR SECURING
METAL TRACK DOUBLE 2x PT PLATE
INSULATED GLAZING AT
ALUMINUM STOREFRONT
BIBB COUNTY
SEE EXTERIOR ELEVATIONS
RECREATION
8" CMU BEYOND AT
WINDOW JAMB FLUTED CMU BEYOND AT WINDOW DEPARTMENT
JAMB
2'-8
2'-8"
"
12 GROUT SILL COURSE SOLID
A2-3 GROUT SILL COURSE SOLID 12
REINFORCING AT 16" OC VERTICAL A2-3
REINFORCING AT 16" OC
AND 24" OC HORIZONTAL (SEE VERTICAL AND 24" OC
SPECIFICATIONS) HORIZONTAL (SEE
SPECIFICATIONS)
8" CMU IN RUNNING BOND
4" FLUTED CMU IN
RIGID INSULATION. SEE STACKED BOND
SPECS RIGID INSULATION. SEE
SPECS
MORTAR MESH
MORTAR MESH 2
A3-4
FLUTED 4" CMU IN STACKED BOND FLUTED 4" CMU IN
STACKED BOND
FLASHING TERMINATION BAR
FLASHING TERMINATION BAR
FLASH AND WEEP AT 24"
4" REINFORCED CONCRETE FLASH AND WEEP AT 24" OC
2 OC
ON 10 MIL VAPOR BARRIER
ON 4" #57 STONE SUB-BASE A3-4 METAL FLASHING AT WEEP 4" REINFORCED CONCRETE
METAL FLASHING AT WEEP
CONSTRUCTION DOCUMENTS
ON 10 MIL VAPOR BARRIER
NEW GRADE SEE AS-1 ON 4" #57 STONE SUB-BASE
0'-0" NEW GRADE Date: 05/16/2016
0'-0" SEE AS-1
Drawn By: SP
Checked By: CG
GROUT CELLS SOLID BELOW GRADE
GROUT CELLS SOLID
BELOW GRADE Project Number: 2016-08
Sheet Name:
CONCRETE FOUNDATION SEE STRUCTURAL
WALL SECTIONS
CONCRETE FOUNDATION
SEE STRUCTURAL
5/16/2016 4:07:40 PM
Sheet Number:
1
WALL SECTION - TWO
1 1/2" = 1'-0"
2
WALL SECTION - ONE
1 1/2" = 1'-0"
A3-2
STANDING SEAM
ROOF TO MATCH
EXISTING ON 30#
BUILDING FELT ON
5/8" PLYWOOD
SHEATHING ON
METAL TRUSSES
AT 2'-0" OC
DASHED LINE:
SECURE NEW CUT AND REMOVE EXISTING TOP AND BOTTOM
TRUSS TO EXISTING ROOF AND STRUCTURE. CHORDS AT NEW
BAR JOIST WITH METAL TRUSS TO
STANDING SEAM ROOF TO MATCH
CLIP ANGLES. BATT INSULATION SUPPORTED BE 6"
EXISTING ON 30# BUILDING FELT ON
BY TYVEK OR SIMILAR 5/8" PLYWOOD ON METAL TRUSSES
AT 2'-0" OC
ED
E QUIR
AS R
SECURE METAL FRAMING LOW
TO TRUSS EXTENSION AS AIR F
SHOWN
6
A1-9
10'-11" TRUSS
TRUSS BEARING
10'-8" BEARING 10'-11"
10'-8"
TOP OF TOP OF
BOND BEAM SECURE GYP BOARD
BOND BEAM TO TRUSS TO KEEP BATT INSULATION
EXISTING JOIST INSULATION OUT OF SUPPORTED ON
SEAT TO REMAIN AIR FLOW TYVEK
NEW DOUBLE C- EXISTING EXTENDED
METAL TRUSS AT 2'-0"
CHANNELS PER JOIST TAILS TO LAY - IN ACOUSTICAL OC SECURE TO PT 2x LAY - IN
STRUCTURAL REMAIN TILE WITH CLIP ANGLE. ACOUSTICAL TILE
7'-4"
A2-2
PARK
RECREATION
CENTER
1"
LOWER WARDROBE
SEE DETAILS SHEET
A5-3
BIBB COUNTY
HOLLOW METAL DOOR FRAME
RECREATION
DEPARTMENT
REVISIONS
# DATE DESCRIPTION
TOILET PARTITION
DOOR IN SECTION
TOILET PARTITION
DOOR BEYOND
TILE EXPANSION JOINT METAL
COVER THRESHOLD SET IN
WATER CLOSET FULL BED OF
BEYOND SEALANT
TURN DOWN NEW SLAB TO
EXISTING FOUNDATION 1/2" EXPANSION
MATERIAL
RUBBER BASE
3 NEW SLAB ON GRADE
A3-4 SEE SPECS.
5 4" REINFORCED
CONSTRUCTION DOCUMENTS
FLOOR FINISH - SEE A2-2 CONCRETE ON 10 MIL
FINISH SCHEDULE VAPOR BARRIER ON 4" Date: 05/16/2016
1/4"
#57 STONE SUB-BASE
SLOPE TO DRAIN
0'-0" 0'-0" 0'-0" Drawn By: SP
Checked By: CG
CONCRETE
5/16/2016 4:07:41 PM
FOUNDATION SEE
STRUCTURAL
Sheet Number:
1
WALL SECTION - THREE
1 1/2" = 1'-0" 2
WALL SECTION - FOUR
1 1/2" = 1'-0"
A3-3
2 TOP AND BOTTOM
6 CHORDS AT NEW
METAL TRUSS TO
BE 6"
ED
E QUIR
AS R
RENOVATION
& ADDITION
TO NORTH
SECURE PER MANU
DASHED
SPECIFICATIONS
EXPANSION JOINT
MACON
LINE:
NEW FLOOR
FINISH - SEE
FINISH SCH.
1" BETWEEN EXISTING AND NEW COVER. SECURE
ON ONE SIDE ONLY
PARK
RECREATION
CENTER
METAL GUTTER
BEYOND BIBB COUNTY
EXISTING TO REMAIN NEW SLAB ON GRADE
SEE SPECS.
8" CMU IN
RECREATION
TURN DOWN NEW SLAB TO
EXISTING FOUNDATION
RUNNING
BOND DEPARTMENT
GUTTER STRAP
MATCH EXISTING
LOCATIONS
REVISIONS
4" FLUTED CMU IN
EXPANSION JOINT COVER STACKED BOND # DATE DESCRIPTION
3
3" = 1'-0"
RIGID INSULATION.
SEE SPECS
MORTAR MESH
CONSTRUCTION DOCUMENTS
SEE STRUCTURAL
FULLY GROUT CAVITY BELOW COMPACTED FILL
Date: 05/16/2016
GRADE
JOINT WEEPS @ 24" OC Drawn By: SP
FINISH GRADE
Sheet Name:
5/16/2016 4:07:43 PM
Sheet Number:
A3-4
CMU WALL
ELECT.
CONDUITS
2.5
CMU WALL
RATING PER
6 3/4" CHAMFER AROUND TOP
SINGLE PLUMBING
PIPE
STEEL PIPE SLEEVE PLAN
5"
BARRIER W/ COMPATIBLE
FASTENED ON BOTH SEALANT, BOTH SIDES C1 ROBINSON FIXED
ANGLE SKATE
FOR CONDUITS LARGER
THAN 1 1/2"
ENDS W/ BREAK FORMED OF RATED WALL DETERRENTS - FA135,
TO ALLOW MOVEMENT,
EC
FILL W/ SEALANT &
BACKER ROD 10 MIL. POLY SHEET
SECURED TO RIDGE
TRIM AND 12" BLOCK
CLEAR ANODIZE
FINISH
CONTINUOUS METAL
ANGLES ON ALL SIDES OF
DUCT PENETRATION.
NOTE: NOT REQUIRED
RENOVATION
STL. COLUMN, DUCT INSULATION
EG
8" REINFORCED CMU
SEE STRUCTURAL FOR
SIZE AND LOCATION
OF REINFORCING
CONC.
SPLASHBLOCK
PAINT SW
7558 MEDICI
IVORY
NOTE:
SEAL ALL OPENINGS,
JOINTS, AND DUCTS
WHERE SMOKE DAMPERS
PENETRATE SMOKE
PARTITIONS
& ADDITION
8" REINFORCED CMU
SEE STRUCTURAL FOR
SIZE AND LOCATION
NEW CONCRETE
BENCH
WITH FIRE STOP
SEALANT. NOTE:
SEAL ALL OPENINGS, JOINTS,
AND DUCTS WITH FIRE STOP
TO NORTH
OF REINFORCING
NOTES:
ACOUSTICAL SEALANT
UNDERSIDE OF
EACH SIDE
ACOUSTICAL FIRE STOPPING STRUCTURE
GROUT TO 1 OPENINGS THROUGH FLOORS, CEILINGS & ROOFS TO BE PROTECTED &
SEALANT EACH SIDE SEALANT EACH SIDE UNDERSIDE OF DECK DEFLECTION TRACKS AT HEAD WALL TYPE: A2K0 SEALED TO A 1 HOUR RATING STANDARD. ALL PENETRATIONS THROUGH
UNDERSIDE OF UNDERSIDE OF UNDERSIDE OF
WHERE FULL HEIGHT ROOF DECK OR • DOUBLE SIDED FURRING RATED WALLS & FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF
ROOF DECK ROOF DECK
DWMS TRACK DWMS TRACK INDICATED SPOT ELEVATION WALL - (1) LAYER 5/8" GYP PREVENTING THE PASSAGE OF FLAMES & HOT GASES, AND TO MEET TEST
NOTED ON FLOOR BD EXPOSED SIDE ONLY STANDARDS FOR FIRE STOP ASTM-E814 OR NFPA 251.
PLAN OVER TWO LAYERS OF 2 1/2"
20 GA DWMS @ 16" OC, 20 GA DWMS @ 16" OC METAL FRAMING, GYP BD TO 2 ALL FIRE WALLS SHALL BE PERMANENTLY IDENTIFIED WITH A SIGN, W/
UNLESS NOTED UNLESS NOTED BE FLUSH W/ CMU LETTERS 2" HIGH ON A CONTRASTING BACKGROUND, SPACED MAX 12'
OTHERWISE OTHERWISE 10'-0" APART AND PLACED WITHIN THE INTERSTITIAL SPACE. MINIMUM OF 1 PER
PT 2x SILL ANCHORED WALL OR BARRIER AND TO READ AS FOLLOWS:
TO GROUTED TOP
BLOCK ACOUSTICAL
LINE OF CEILING- SEE LINE OF CEILING- SEE LINE OF CEILING - SEE
REFLECTED CEILING SEALANT, EA SIDE " 1- HOUR FIRE RATED WALL - PROTECT ALL OPENINGS."
FINISH SCHEDULE FINISH SCHEDULE
CONSTRUCTION DOCUMENTS
PLAN
SHEATHING REF SHEATHING REF WALL SHEATHING REF SHEATHING REF WALL
WALL TYPE TYPE MODIFIER WALL TYPE TYPE MODIFIER Date: 05/16/2016
MODIFIER MODIFIER
NOTE: SEAL ALL
CMU WALL CMU WALL
PENETRATIONS PER
DETAILS ON A4-1 AND
Drawn By: SP
SPEC SECTION 07270
DWMS TRACK DWMS TRACK Checked By: CG
BASE - SEE FINISH BASE - SEE FINISH BASE - SEE FINISH BASE - SEE FINISH
SCHEDULE NOTE: SEAL ALL SCHEDULE NOTE: SEAL ALL SCHEDULE NOTE: SEAL ALL SCHEDULE NOTE: SEAL ALL Project Number: 2016-08
PENETRATIONS WITH PENETRATIONS WITH PENETRATIONS WITH PENETRATIONS WITH
ACOUSTICAL ACOUSTICAL SEALANT FIRE STOPPING FIRE STOPPING ACOUSTICAL SEALANT ACOUSTICAL SEALANT
SEALANT EACH SIDE SEALANT EACH SIDE SEALANT Sheet Name:
5/16/2016 4:07:45 PM
NON-RATED WALL RATED WALL NON-RATED CMU WALL CMU WALL W/ DWMS TOP Sheet Number:
A SCALE : 1 1/2" = 1'-0"
B SCALE : 1 1/2" = 1'-0"
D SCALE : 1 1/2" = 1'-0"
E SCALE : 1 1/2" = 1'-0"
2
WALL TYPE DETAILS
1 1/2" = 1'-0"
A4-1
GS LOPE
G C EILIN
IN
E XIST
3:12
LIGHT
P4
P5
P1
P1 P1
LIGHT P2
VARIES
A2K0
4
P4 1'-0" A6-1
EXISTING STRUCTURE PAINT PAINT 1'-0" 1'-0" PAINT 1'-0"
ACCENT ACCENT ACCENT
1'-0" BEHIND 1'-0" BEHIND BEHIND P4
PLYWOOD SUPPORT AT PLYWOOD PLYWOOD
P5
CANOPY (TYPICAL)
EQ EQ DECORATIVE
WOOD CANOPY
SEE DETAIL SHEET NEW WINDOW
GRAIN
PLAM
A6-1 (TYPICAL) IN EXISTING
WALL
P1 LIGHTING (TYPICAL) P1
EXISTING
CMU
10'-0"
CORR. E8F0 E8F0 CORR. R1 FEC
3/4" PLYWOOD 3/4" PLYWOOD
101 3/4" PLYWOOD 101 WAINSCOAT
WAINSCOAT PANEL COVERED PANEL COVERED CORR. P1
1,927 SF 101 PANEL COVERED 1,927 SF TYPICAL IN ALL
TYPICAL IN ALL W/ L2 PLASTIC P1 W/ L2 PLASTIC
1,927 SF W/ L2 PLASTIC P1 CORRIDORS
CORRIDORS LAMINATE. PAINT LAMINATE. PAINT
6'-8"
LAMINATE. PAINT
CMU BEHIND CMU BEHIND
CMU BEHIND
PLYWOOD P-1 PLYWOOD P-1
PLYWOOD P-1
P3 P3
3'-4"
RENOVATION
1
105 GATHERING AREA
3/8" = 1'-0"
& ADDITION
TO NORTH
MACON
4'-8" A3-1
2
PARK
P1 GYP BOARD
P4
A2K0
P1 GYP BOARD
RECREATION
P1 P1
CENTER
112A R1 R1
E8F0
WAINSCOAT
TYPICAL IN ALL
CORRIDORS
BIBB COUNTY
RECREATION
P3 P3 DEPARTMENT
3'-4"
2
SOUTH CORRIDOR ELEVATION 815 N MACON PARK DR
3/8" = 1'-0" MACON, GA 31210
REVISIONS
# DATE DESCRIPTION
2
A3-1
NEW WALL - GYP BOARD ON METAL STUDS
EXISTING CEILING
HEIGHT VARIES
EXISTING STRUCTURE
(TYPICAL) A2K0 LIGHT
P4
P1
SUSPENSION WIRE
3/4" 6'-0"
DECORATIVE
EQ EQ WOOD CANOPY
P1 P4
P1
OPP LIGHT
CONSTRUCTION DOCUMENTS
4
P1
A6-1 Date: 05/16/2016
NEW CMU WALL
112B R1
R1 E8F0 Drawn By: CN
WAINSCOAT
TYPICAL IN ALL
EXISTING CORRIDORS
FEC
CMU WALL
Checked By: CG
3'-4"
P3 Sheet Name:
INTERIOR ELEVATIONS
5/16/2016 4:07:48 PM
3
3/8" = 1'-0"
Sheet Number:
A5-1
SUBSTRATE (WALL OR CLG)
SUBSTRATE (WALL OR CLG)
2X4 STUD FRAMING, MAX 24" OC
2X4 STUD FRAMING, MAX 24" OC 2" 1 1/2" ALL DIRECTIONS; PAINT EXPOSED 2" 1 1/2"
ALL DIRECTIONS; PAINT EXPOSED EDGES TO MATCH WALL COLOR
EDGES TO MATCH WALL COLOR MIN. MIN.
1/2"
1/2"
1/2" BEVEL ALL (4) SIDES 1/2" BEVEL ALL (4) SIDES
FACE OF WALL
FACE OF WALL
FASTENER; SINK AND INT. ELEVS. FOR PATTERN; CARRY
ADJ. PAINT COLOR AT PANEL 1/2"
PAINT OVER
FACE AT SIDES OF REVEAL AND
TERMINATE AT NEAREST INSIDE
SOUND BLANKET CORNER
PAINT BACK OF REVEAL SIM TO
PANEL, UNO
SOUND BLANKET
3:12
E
SLOP XISTING
P4
LIGHT
VARIES
P4 P1
5'-4"
DIMENSION P4 P4 P4 3'-0"
3'-0"
VARIES
3'-4"
3'-4"
3'-4"
P4 P4 P1 P4 P4
3'-0"
3'-0"
4'-0" EQ. 4'-0" EQ. 4'-0" EQ. 4'-0" EQ. 4'-0" EQ. 4'-0"
TECTUM PANEL, TECTUM PANEL, TECTUM PANEL, TECTUM PANEL, TECTUM PANEL, TECTUM PANEL, 11'-8" 11'-8"
ALTERNATE NO. 3 ALTERNATE NO. 3 ALTERNATE NO. 3 ALTERNATE NO. 3 ALTERNATE NO. 3 ALTERNATE NO. 3
8 3/8" 4'-0" 3'-4" 4'-0" 3'-4" 4'-0" 3'-4" 4'-0" 1'-1 3/8"
P1
6'-8"
6'-8"
6'-8"
6'-8"
TECTUM PANEL, TECTUM PANEL, TECTUM PANEL, TECTUM PANEL,
ALTERNATE NO. 3 ALTERNATE NO. 3 ALTERNATE NO. 3 ALTERNATE NO. 3
P1
E8F0
P1
E8F0
MP ROOM P1
RENOVATION
112
978 SF
& ADDITION
11'-4"
TO NORTH
112B
MP ROOM R1 R1
8"
8"
P5 MB-1 P5 P5
112
978 SF
1'-4"
1'-4"
P2 P2 P2
MACON
PARK
3'-4"
3'-4"
P3 P3 P3
RECREATION
1
112 MP ROOM A
3/8" = 1'-0"
2
112 MP ROOM B
3/8" = 1'-0"
CENTER
BIBB COUNTY
RECREATION
EXISTING
CLERESTORY
WINDOWS
DEPARTMENT
EXISTING
STRUCTURE
HT VARIES
EQ. 2'-0" 2'-0" EQ. P1
9'-4"
EXISTING CONSTRUCTION TO REMAIN
P4 P4 P4 P4 P1 P4
7'-4"
5'-3"
5'-3"
5'-3"
5'-3"
10 7/8" 4'-0" EQ. 4'-0" EQ. 4'-0" EQ. 4'-0" 10 7/8"
5'-4"
P4 P4 P4
TECTUM PANEL,
3'-4"
3'-4"
4'-0" EQ. 4'-0" EQ. 4'-0" EQ. 4'-0" EQ. 4'-0" EQ. 4'-0" GRILLE GRILLE
TECTUM PANEL, TECTUM PANEL, TECTUM PANEL, TECTUM PANEL, TECTUM PANEL, TECTUM PANEL,
ALTERNATE NO. 3 ALTERNATE NO. 3 ALTERNATE NO. 3 ALTERNATE NO. 3 ALTERNATE NO. 3 ALTERNATE NO. 3
EXISTING GRILLE
P1 P1 TO BE REPLACED
4"
4"
4"
A2K0 A2K0
P1 E8F0
CONSTRUCTION DOCUMENTS
P1 P1 P1
Date: 05/16/2016
11'-4"
E8F0 Drawn By: CN
NEW CMU WALL
8"
P5 P5 P5 P5 P5 P5
8'-8"
113
Checked By: CG
1'-4"
1'-4"
P2 P2 P2 P2 P2 P2
3'-4"
P3 P3 P3 P3 Sheet Name:
INTERIOR ELEVATIONS
5/16/2016 4:07:51 PM
112 MP ROOM C 112 MP ROOM D Sheet Number:
3 4
3/8" = 1'-0" 3/8" = 1'-0"
A5-2
COILING DOOR
14'-0"
OVERHEAD COILING 1 P1, SEE FINISH PLAN 1" 3'-0" 3'-0" 3'-0" 3'-0" 1'-11"
EXISTING FLUTED COUNTER DOOR A5-4 FOR FEATURE WALL SCR
CMU INFILL @ DEMOLISHED DOOR NEW CMU WALL
BLOCK CMU, P1 PAINT LOCATIONS
1'-4"
2'-4 1/4"
P1, SEE FINISH PLAN
CORR. FOR FEATURE WALL
101 2
3'-4"
3'-4"
PAINT LOCATIONS COILING DOOR
1,927 SF A5-4 IN SECTION
CORR. RECEPT.
101 104
1,927 SF P1 P1 P1
140 SF
P1, SEE FINISH
2'-6"
2'-6"
PLAN FOR
RECEPT.
5'-6"
P1
FEATURE WALL
104 NO
1" DIA. FINGER 104C PAINT
140 SF BACKSPLASH
3'-4"
3'-4"
HOLES (TYP) WAINSCOAT R1 WAINSCOAT R1 LOCATIONS
2" 2" @ COILING
104C
TYPICAL IN ALL TYPICAL IN ALL WAINSCOAT DOOR RECEPT. 4" BACKSPLASH
1'-8"
1'-8"
CORRIDORS 104A
CORRIDORS TYPICAL IN ALL
104A 1 7 104
IT-1
CORRIDORS A5-4 A5-4 140 SF
4"
4"
2"
13
P3 P3 P3 P3 NO BACKSPLASH A2-2
CORR.
2'-8"
BETWEEN COUNTER &
2'-6"
2'-6"
2'-6"
2'-6"
101 WINDOW
1,927 SF
2'-0" 10 12
13 CMU INFILL @
TROPHY 13
TROPHY CASE CMU INFILL @ DEMOLISHED DOOR DESK WITH SUPPORT 10 A5-4
1" 4'-0" 4'-0" CASE - SEE A2-2 A5-4 12
IN SECTION DEMOLISHED DOOR A2-2 A5-4
DETAIL A5-4
SCR 2 1" 3'-0" 3'-0" 3'-0" 3'-0" 1'-11"
A5-4 SCR
14'-0"
103 TROPHY CASE 104 RECEPTION A 104 RECEPTION B 104 RECEPTION C 104 RECEPTION D 104 RECEPTION E
1 2 3 4 5 6
3/8" = 1'-0" 3/8" = 1'-0" 3/8" = 1'-0" 3/8" = 1'-0" 3/8" = 1'-0" 3/8" = 1'-0"
INSULATED GLASS
INSULATED GLASS IN ALUMINUM STOREFRONT
IN ALUMINUM
2 NEW CMU NEW CMU - SEE 18
STOREFRONT
SEE SECTION SECTIONS A5-4
A3-2
NEW CMU 2
SEE SECTION MARKER BOARD 2 2
A3-2 INSULATED GLASS
MB-1 A3-2 A3-3
IN ALUMINUM STOREFRONT
P1 P1 P1
P1 MILLWORK
MP ROOM
119
760 SF
MP ROOM MP ROOM
W1 W1 MB-1 119 W1 W1 119
9'-0"
760 SF 760 SF
RENOVATION
8" 8"
8" 8"
8" 8"
P5 P5 P5 P5 P5
P2 P2 P2 P2 P2 119B
P3 & ADDITION
3'-4"
3'-4"
3'-4"
P3 P3 P3
TO NORTH
119 MP ROOM A 119 MP ROOM B 119 MP ROOM C
MACON
7 8 9
3/8" = 1'-0" 3/8" = 1'-0" 3/8" = 1'-0"
PARK
RECREATION
CENTER
9'-2 1/2"
HOLLOW METAL
1 1/4" 2'-3" 2'-3" 2'-3" 2'-3" 1 1/4" DOOR AND FRAME
BIBB COUNTY
NEW CMU WALL
1
2
A3-1
HOLLOW METAL
DOOR AND FRAME HANDICAP ACCESSIBLE RECREATION
A3-3 MARKER BOARD SHOWER STALL - SEE
NEW EXG
DEPARTMENT
1"
SHEET A1-2
1'-11"
P1
2'-0"
P2 120 119A
T22
T4
T20 T20 T20 T20 T20 REVISIONS
T3 T17 T17 T17 T17 T17 T17 SHOWERS F
T10 122
# DATE DESCRIPTION
3'-4"
53 SF
3'-0"
PROVIDE TILE
CONSTRUCTION DOCUMENTS
SHOWERS F CONTROL JOINT AT
122 CT1 EXG/NEW WALL PROVIDE TILE CONTROL CT1 Date: 05/16/2016
53 SF INTERSTECTION JOINT AT EXG/NEW WALL
SHOWERS F INTERSTECTION
122 T24
T24 Drawn By: CN
6" 1'-0" 6"
4'-0"
122 T10 T10 Sheet Name:
53 SF
INTERIOR ELEVATIONS
5/16/2016 4:07:58 PM
TOILET TOILET ACCESSORIES
PARTITION TOILET TOILET ACCESSORIES
IN SECTION PARTITION
Sheet Number:
IN SECTION
122 SHOWERS F 2 122 SHOWERS F 3 122 SHOWERS F 4 123 TLT M 2 121 TLT FEMALE
15 16 18 19
A5-3
14
3/8" = 1'-0" 3/8" = 1'-0" 3/8" = 1'-0" 3/8" = 1'-0" 3/8" = 1'-0"
GENERAL CASEWORK NOTES:
1 1/2"
T-MOLDING EDGE
FINISHED BOTTOM FINISHED BOTTOM (CHARTER
INDUSTRIES #5720)
SEALANT SEALANT 3/4" CONTINUOUS,
SOLID PLYWOOD
NOTE: REFERENCE INTERIOR ELEVATIONS FOR
T-MOLDING LOCATIONS
POST-FORMED PLASTIC
LAMINATE COUNTERTOP
(REF ELEV FOR LOCATIONS)
1 1/2" BULLNOSE
SEALANT
1 1/2"
SEALANT SEALANT 3/4" CONTINUOUS,
END SPLASH
SOLID PLYWOOD
END SPLASH
COUNTERTOP (REF 2'-1" 3/4" CONTINUOUS, SOLID
COUNTERTOP (REF END SPLASH PLYWOOD, (2) LAYERS
FINISH SCHEDULE FOR
FINISH SCHEDULE FOR COUNTERTOP (REF FINISH WHERE INDICATED
MATERIAL)
MATERIAL) 2'-1" SCHEDULE FOR MATERIAL) 2'-1" TYPICAL
4"
4"
4"
REF TYPICAL EDGE DETAILS TYPICAL POST-FORMED PLASTIC
REF TYPICAL EDGE DETAILS
REF TYPICAL EDGE DETAILS 3/4" SOLID, CONTINUOUS LAMINATE COUNTERTOP
3/4" SOLID, CONTINUOUS PLYWOOD SUPPORT
WD BLOCKING W/ PLAM
ON ALL EXPOSED PLYWOOD SUPPORT
TYPICAL COUNTERTOP EDGE DETAILS
EDGES AT COUNTERTOP ICE 5
13/16" DOOR & DRAWER. MACHINE LOCATIONS -
3" = 1'-0"
FRONT W/ PLAM ON ALL
2 EQ DRAWERS
3/4" SOLID, CONTINUOUS PROVIDE 2 LAYERS 3/4"
PLYWOOD SUPPORT EXPOSED SURFACES PLYWD SUPPORT
REFERENCE INTERIOR ELEV
RENOVATION
2'-10"
PLAM 3/4" SHELF PLAM 3/4" SHELF
& ADDITION
FILE DRAWER
HOLES DRILLED @ 2" OC TO HOLES DRILLED @ 2" OC TO
RECEIVE NYLON SHELF RECEIVE NYLON SHELF
1'-0"
CLIPS CLIPS
3
SCHEDULED BASE
BLOCKING A6-1
TO NORTH
MACON
4"
4"
4"
LAY - IN ACOUSTICAL
SCHEDULED BASE SCHEDULED BASE TILE
PARK
2" 2" 2"
1"
BASE CABINET BASE DRAWER & CABINET 3-DRAWER BASE W/ FILE DRAWER
6 7 8
1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0"
CMU BEYOND AT
RECREATION
CENTER
ALCOVE FOR
MILLWORK
REF TYPICAL
EDGE DETAILS
DOOR HANDLE-
3/4"
RECREATION
3/4" SOLID, CONTINUOUS REF SPEC.
DEPARTMENT
1 3/4"
PLYWOOD SUPPORT
SEALANT 1"
3" ROUND GROMMET LOCATION
DETERMINED AT SITE ALUMINUM TRACKS LET
SEE ELEVATION FOR COUNTER HEIGHT
3'-5 1/2"
CLIPS
PLAM COVERED 3/4"
# DATE DESCRIPTION
THK. SHELF. NOTE: AT
SHELVES LONGER THAN
37" USE 5/4" TRIM.
8'-7"
SCHEDULED BASE
9'-0"
DOOR HANDLE- 5/4 MATERIAL
REF SPEC.
TYPICAL WORK COUNTERTOP
10 1" DIAMETER FINGER
1 1/2" = 1'-0" 20" CLEAR
HOLE AT GLASS 3/4"
6'-7 1/2"
13/16" DOOR W/
3" 1"
PLAM ON
7'-0"
EXPOSED
SEALANT SEALANT SURFACES
1 3/4"
END SPLASH 2'-1"
END SPLASH MATERIAL
COUNTERTOP (REF BEYOND COUNTERTOP (REF
FINISH SCHEDULE FOR FINISH SCHEDULE FOR
MATERIAL) SS COUNTERTOP MATERIAL)
4"
2'-1"
4"
1/2"
DOOR HANDLE-
REF TYPICAL EDGE DETAILS REF SPEC.
6 1/2"
2'-6 1/2"
SS APRON ON 1X SHELVES OVER PLAM 3/4" SHELF
CONSTRUCTION DOCUMENTS
BACKING 37" LONG
2'-10" TO TOP OF SINK BASIN
Date: 05/16/2016
2'-0 1/2"
REFERENCE INTERIOR ELEV
STEEL COUNTER
SUPPORT - SEE
ELEVATION FOR CN/SP
PLAM 3/4" SHELF
LOCATION
Drawn By:
2'-9 1/2"
EQ
PLAM
COVERED 3/4" 13/16" DOOR W/ PLAM
2'-3" MIN
4"
FINISH
2" SCHEDULED BASE
BASE AS CASEWORK DETAILS
9"
SCHEDULED
4"
4"
2" 1'-10"
SCHEDULED BASE
4"
BLOCKI BLOCKI
5/16/2016 4:08:00 PM
SCHEDULED BASE 2'-0"
NG NG
TALL STORAGE CABINET W/ SOLID Sheet Number:
BASE OPEN SHELVES 34" ADA SINK BASE, TYPICAL TALL OPEN STORAGE SHELVES DOORS TROPHY CASE
12 15 16 18 2
A5-4
1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0"
CEILING CEILING - GYP DIFFUSER - SQUARE
ACT-1 BOARD FINISH, SUPPLY
WALL TYPE (SEE A4-1) WALL TYPE MODIFIER FIRE RATING WALL HATCH PATTERN LEGEND 24" x 24" PAINT CEILING
STUD/CMU WIDTH ACOUSTIC CEILING TILE WHITE REGISTER - SQUARE RETURN
WALL TYPE MODIFIER A. 5/8" GYP BD EACH SIDE (NO SAB: STC 45 / WITH SAB: STC 49) 0 NOT RATED PARTITION TO RESIST THE 9/16" GRID
B. 5/8" GYP BD EACH SIDE UL# U465, GA FILE NO: WP1200 (NO S PARTITION TO RESIST THE PASSAGE OF SMOKE PASSAGE OF SMOKE
FIRE RATING REGISTER - EXHAUST
SAB: STC 45 / WITH SAB: STC 49) B 1 HOUR RATED SMOKE BARRIER CEILING OPEN TO STRUCTURE
C. (2) LAYERS 5/8" GYP BD EACH SIDE UL# U411, GA FILE NO: C 2 HOUR RATED SMOKE BARRIER 1 HOUR RATED FIRE
ALTERNATE. NO. 2 ACT ABOVE
WP1548 (NO SAB: STC 50 / WITH SAB: STC 54) 1 1 HOUR RATED FIRE BARRIER BARRIER LIGHTING - RECESSED FIXTURE
24" x 24" OPEN
A2F3 D. (1) LAYER 1" GYP BD SHAFT SIDE, 2 LAYERS 1/2" GYP BD 2 2 HOUR RATED FIRE BARRIER / FIRE WALL 1 HOUR RATED SMOKE ACOUSTIC CEILING TILE
OTHER SIDE UL# U438, GA FILE NO: WP 7095 (NO SAB: STC 45 / 3 3 HOUR RATED FIRE WALL BARRIER 9/16" GRID LIGHTING - RECESSED FIXTURE
WITH SAB: STC 49) 4 4 HOUR RATED FIRE WALL NON RATED
E. (1) LAYER 5/8" GYP BD EXPOSED SIDE ONLY (NO SAB: STC 45 / SYMBOL DESIGNATION MASONRY SOFFIT SUSPENDED CEILING SYST.
# STUD WIDTH CMU WIDTH LIGHTING - RECESSED DOWN LIGHT
WITH SAB: STC 49) METAL SOFFIT PANEL CE-1
1 1 5/8" NON RATED MASONRY
F. NO SHEATHING FOR WALL TYPES INDICATED TO RECEIVE SOUND COLOR: WHITE ARMSTRONG
2 2 1/2" STACKED WALL - CMU BASE & LIGHTING - RECESSED FIXTURE 24" x 48"
G. 7/8" HAT CHANNELS W/ 5/8" GYP BD EACH SIDE ATTENUATION, EXTEND SOUND ATTENUATION TO FULL WOODWORKS GRILLE
3 3 5/8" GYP FURRING WALL TOP
H. 7/8" HAT CHANNELS W/ 5/8" GYP BD ONE SIDE ONLY HEIGHT OF WALL UNLESS OTHERWISE INDICATED. REFER 7091BD BACKER & DOWEL LIGHTING - RECESSED FIXTURE 12" x 48"
4 3 5/8"
I. NOT USED TO INDIVIDUAL WALL TYPE MODIFIER FOR STC RATINGS. COLOR: MAPLE
6 6" 5 5/8"
J. (1) LAYER 5/8" GYP BD EXPOSED SIDE ONLY. TEMPORARY LIGHTING - RECESSED FIXTURE 24" x 24"
8 8" 7 5/8" X#X#
INFECTION CONTROL WALL SEAL TO FLOOR AND DECK. X#X#
12 11 5/8"
K. DOUBLE SIDED FURRING WALL - (1) LAYER 5/8" GYP BD EXIT SIGN
EXPOSED SIDE ONLY OVER TWO LAYERS OF 2 1/2" METAL
FRAMING, GYP BD TO BE FLUSH W/ CMU WITH SOUND NO SOUND S SPEAKER
ATTENUATION ATTENUATION
LIGHTING - PENDANT FIXTURE 6" MOUNT
30.0
BACKER CLIP 15/16" MAIN SUSPENSION BEAM 4 RELOCATE EXISTING LIGHT FIXTURES & CENTER IN CEILING SPACE
0°
10'-0"
SURFACE MOUNTED LIGHTING 3/4" PLYWOOD PANEL 3" / 12" 3" / 12"
2'-0"
FIXTURE CENTERED IN GRILLE COVERED W/ PLASTIC METAL SOFFIT PANEL
SYSTEM, RUN CIRCUIT CONDUIT LAMINATE SEE INTERIOR
TIGHT TO CENTERED
SUSPENSION BEAM
ELEVATIONS
H
CMU WALL, SEE PLAN FOR TYPE
1 1
A3-1 A3-1
2 2
ACT-1
A3-2 A3-2
3'-6"
9'-0"
MP ROOM
119
METAL SOFFIT PANEL 9'-4"
CE-01 SUSPENDED CEILING SYSTEM 3 9'-4"
4
3" = 1'-0" CONSTRUCT NON-RATED A2E0 TYPE
A6-1
FURRING WALL ON TOP OF NEW AND
EXISTING CMU WALLS. GYP BOARD TO BE
ON RENOVATED TOILETS SIDE OF WALLS.
TAPE JOINTS & SEAL ALL PENETRATIONS.
RENOVATION
E1
9'-4"
3
STORAGE
120
9'-4"
E7
& ADDITION
EG
9'-4"
8'-8"
GYP CEILING BOARD
TO NORTH
GYP CEILING BOARD
EF
9'-4"
SHOWERS F
122
2 2
SHOWERS M
124
8'-8"
2
MACON
ACT-1
PARK
3 8'-8"
STORAGE GYP CEILING BOARD 3
129 9'-4"
TLT F TLT M 8'-8"
121 3 123
3 3
ED
ACT-1
2
9'-4"
2
9'-4"
14'-2"
3
1
JAN.
118
14'-2"
1
3 14'-2"
1 3
METAL SOFFIT PANEL
RECREATION
CENTER
3 VEST.
NEW ACT-2
ETR NEW ACT-2 125
EQ
METAL STUD FRAMING AT DROP
9'-4" 4 4
2x NAILER NEW ACT-2
ETR
EQ
3/4" MATERIAL FINISHED THE SAME 16'-7 1/8" EQ EQ EQ EQ
AS THE ADJACENT MILLWORK AND
3" / 12"
SEE RCP 117
ETR
1"
ACT-1
GATHERING AREA
5'-10"
105
LAY IN ACOUSTICAL TILE ALT. NO. 2 ACT
STORAGE ETR
113 KILNS
115
3" / 12"
3" / 12"
4
5'-10"
MP ROOM
INTERIOR OF 1"
1" FILLER - SEE ELEVATION
A6-1 112 815 N MACON PARK DR
UPPER CAB CE-01
SEE MILLWORK
OFC.
116
9'-4"
MACON, GA 31210
ELEVATIONS
6'-3 1/2"
CORNER OF CMU BEYOND
ETR 9'-4"
ACT-1
REVISIONS
GYMNASIUM CRAFT
127
5'-10"
FACE OF CABINET DOOR 114 # DATE DESCRIPTION
CE-01
9'-0"
EQUIP.
128
9'-0" 1 1 1
EC 9'-4"
CEILING AT MILLWORK 9'-4" VEST.
3 111
3" = 1'-0" 2" / 12"
TROPHY CASE
103
ALT. NO. 2 ACT
MTG ROOM
106
VEST.
100
ETR ETR
ETR
ACT-1 STORAGE PANTRY ELEC.
107 109 110
EB
CONSTRUCTION DOCUMENTS
LINE OF STRUCTURE 9'-4"
Date: 05/16/2016
ABOVE. REFER TO 2.5 METAL SOFFIT PANEL
SECTIONS FOR MORE PROVIDE 3 5/8"
INFORMATION DWMS BRACES
C1 Drawn By: BEJ
AT 32" OC
CEILING TIE TO
6
STRUCTURE ABOVE 3 5/8" DWMS
A1-3 Checked By: CG
AT 16" OC
EA
6" TYP.
5/16/2016 4:08:03 PM
TYPICAL CEILING BULKHEAD 2 Sheet Number:
1
3/4" = 1'-0" A3-1
2
REFLECTED CEILING PLAN
1/8" = 1'-0"
SCALE: 1/8" = 1'-0"
5'-0"
110 ELEC. 70 SF ETR ETR ETR ----- ----- VCT4 VCT2 VCT4 FLOORS
VCT4 VCT2 VCT4
111 VEST. 40 SF P1, P3 VCT1, 2, 3, 4 B1 ----- ----- SEE FINISH PLAN FOR FLOORING LOCATIONS AND ELEVATIONS FOR PAINT LOCATIONS VCT2
B1 (WALL BASE) JOHNSONITE 129 SILK
112 MP ROOM 978 SF P1, P2, P3, P4, P5 VCT2, 3, 4 B1 ----- ----- SEE ELEVATIONS FOR ACOUSTICAL PANEL AND PAINT LOCATIONS. SEE FINISH PLAN FOR
FLOORING LOCATIONS. VCT1 (FIELD VCT) AZROCK CORTINA COLORS V603-3 BUFF
12'-0"
13'-0"
13'-0"
113 STORAGE 80 SF P1 VCT1 B1 ----- -----
VCT3 VCT2 (ACCENT VCT) AZROCK CORTINA COLORS V628-3 SANGRIA
114 CRAFT 419 SF P1 VCT1 B1 ----- ----- VCT3 VCT3 VCT3
115 KILNS 205 SF ETR ETR ETR ----- ----- VCT3 (ACCENT VCT) AZROCK CORTINA COLORS V885-3 HONEY
9'-5 1/8"
116 OFC. 168 SF ETR ETR ETR ----- ----- VCT4 (ACCENT VCT) AZROCK CORTINA COLORS V606 TOASTED CINNAMON
117 OFC. 168 SF ETR ETR ETR ----- -----
118 JAN. 24 SF ETR ETR ETR ----- ----- 5'-4 3/8" 2'-0" 3'-0" 2'-0" 3'-0" 2'-0" 2'-9 3/8" 2'-0" 3'-0" 2'-0" 3'-0" 2'-0" 2'-0" 2'-0" 2'-0" CT4 (PORCELAIN FLOOR TILE) DALTILE KEYSTONES PORCELAIN DK13 CHOCOLATE BLEND 1 X 1
119 MP ROOM 760 SF P1, P2, P3, P4, P5 VCT2, 3, 4 B1 ----- ----- SEE FINISH PLAN FOR FLOORING LOCATIONS AND ELEVATIONS FOR PAINT LOCATIONS MP ROOM CASEWORK
119 8
13'-0"
120 STORAGE 71 SF P1 VCT1 B1 ----- ----- VCT3
12'-0"
VCT3 VCT3 L1 (HORIZONTAL LAMINATE) WILSONART 4862k-07 SANDY TOPAZ
121 TLT F 268 SF P1; CT1, CT2, CT3 CT4 CTB1 ETR ETR SEE FINISH PLAN AND ELEVATION FOR NEW TILE WALL LOCATION. PROVIDE SANIGLAZE 760 SF
7 A5-3 9 VCT3
10'-0"
ON SPECIFIED SURFACEGLAZE RESTORATION ON ALL EXISTING TILE WALLS. PROVIDE SANIGLAZE 10 L2 (VERTICAL LAMINATE) NEVAMAR SANTA ROSA PLUM TREE WZ2001T
9'-1"
WALL ONLY ENDURAGLAZE COATING ON NEW TILE FLOOR.
VCT4 VCT4 ALUMINUM WINDOW BLINDS
122 SHOWERS F 53 SF P1 CT4 CTB1 ----- ----- PROVIDE SANIGLAZE SURFACEGLAZE RESTORATION ON ALL EXISTING TILE WALLS. VCT4 VCT4 VCT4
5'-0"
PROVIDE SANIGLAZE ENDURAGLAZE COATING ON NEW TILE FLOOR. VCT2 BALI CONTRACT HORIZONTAL BLINDS 1" 8 GAUGE SLAT FLAX 541
VCT2 VCT2 VCT2
123 TLT M 407 SF P1; CT1, CT2, CT3 CT4 CTB1 ETR ETR SEE FINISH PLAN AND ELEVATION FOR NEW TILE WALL LOCATION. PROVIDE SANIGLAZE
ON SPECIFIED SURFACEGLAZE RESTORATION ON ALL EXISTING TILE WALLS. PROVIDE SANIGLAZE
WALL ONLY ENDURAGLAZE COATING ON NEW TILE FLOOR.
124 SHOWERS M 120 SF ETR CT4 CTB1 ----- ----- PROVIDE SANIGLAZE SURFACEGLAZE RESTORATION ON ALL EXISTING TILE WALLS. FINISH LEGEND
PROVIDE SANIGLAZE ENDURAGLAZE COATING ON NEW TILE FLOOR. 1 1/2" = 1'-0"
125 VEST. 38 SF P1, P3 VCT1, 2, 3, 4 B1 ----- ----- SEE FINISH PLAN FOR FLOORING LOCATIONS AND ELEVATIONS FOR PAINT LOCATIONS
126 AK 273 SF ETR ETR ETR ----- ----- STORAGE P1
127 GYMNASIUM 7,140 SF ETR ETR ETR ----- ----- 120
11'-1 7/8"
VCT2
128 EQUIP. 177 SF ETR ETR ETR ----- ----- 71 SF P1
129 STORAGE 132 SF P1 VCT1 B1 ----- -----
NEW
VCT4
17'-1 7/8"
TILE
WALL
19A5-3
SHOWERS F
122 A5-319
NEW
P1 53 SF TILE
WALL
SHOWERS M
124
120 SF
TLT F
121
VCT3
268 SF
STORAGE
14'-0"
129
132 SF TLT M
123
22'-0" 407 SF
10'-0"
VCT2
JAN.
118
6'-0" 16'-0" 24 SF "
-0 VCT2
4'
VEST.
VCT3 VCT4 VCT2 125
VCT2 VCT3 VCT4 38 SF
ETR 1'-0"
1'-0" 4'-0" 1'-0"
1'-0"
VCT3
7'-0"
VCT4
VCT2
11'-0"
VCT3
VCT4
VCT2
TO NORTH
VCT3
3'-0"
11'-9 5/8"
2'-0" 2'-0"
MACON
VCT4
VCT4
OFC. 1'-0"
1'-0" 7'-4 1/4" 19'-0" VCT2
117
PARK
VCT4
VCT4
11'-0"
168 SF
16'-0"
18'-9 3/4"
3'-0"
AK
8'-0"
126
RECREATION
VCT4 273 SF
VCT2
2'-0"
VCT2 19'-0"
VCT2
ETR
3'-0"
CENTER
2'-0"
VCT2
VCT4 KILNS
VCT3
ETR
VCT3
115
3'-0"
113
80 SF
GATHERING AREA
VCT2
OFC. 105 2
6'-0"
18'-0"
VCT4
VCT3
116 280 SF
BIBB COUNTY
10'-0"
A5-1 1 1 A5-2 3
168 SF 15'-0"
VCT4
4 VCT2
7'-0"
RECREATION
3'-0"
MP ROOM
112
978 SF DEPARTMENT
VCT4
VCT3
6'-0"
2'-0"
15'-0"
VCT4 16'-0"
ETR VCT4
2'-0"
VCT2
VCT2
8'-0" 8'-0"
3'-0"
4'-0"
2'-0" 4'-0" 2'-0"
GYMNASIUM VCT4
7'-0"
11'-0 5/8"
7,140 SF 177 SF 419 SF
VCT4
MACON, GA 31210
7'-0 5/8"
VCT3
13'-0"
15'-0" VCT2 VCT4
ETR VCT4 16'-0"
VCT2
5'-0" 24'-0"
5'-0 5/8"
VCT2
REVISIONS
2'-0"
11'-0"
VCT3 VCT4 VCT2 VCT3 # DATE DESCRIPTION
VCT3
VCT2 VCT3 VCT4 VCT2
12'-0" 18'-0" 22'-0" 7'-1 1/4" VCT2
4'-0"
2 VEST.
6 VCT4 111
12'-0" A5-1 14'-0" 15'-0" 11'-1 1/4"
RECEPT. 40 SF
104 A5-3 5 VCT3
P5 3 A5-3 VCT4 VCT3 VCT2 VCT4 4'-0"
140 SF 4
10'-0"
A2-1 2
6'-0"
VCT2
6'-0"
VCT4
VCT4
7'-8 1/4"
4'-0"
VCT2
VCT1 KITCHEN
6'-7 5/8" 5'-0" 5'-0" 108
249 SF
TROPHY CASE VCT4
2'-0"
103
1 A5-3 MTG ROOM
4'-0"
38 SF
VCT4 106
6'-0"
VCT3 954 SF
4'-0"
1'-0"
2'-0"
VCT3
ETR ETR
2'-0"
1'-0"
VCT2 VEST.
1'-0"
100
1'-0"
CONSTRUCTION DOCUMENTS
7'-1 3/4"
107 110
48 SF 70 SF Date: 05/16/2016
PANTRY
109
36 SF
Drawn By: CN
Checked By: CG
Sheet Name:
FINISH PLAN &
SCHEDULE
5/16/2016 4:08:06 PM
Sheet Number:
1
FINISH PLAN
3/16" = 1'-0" A7-1
25
19 19
15
T
10 13
7 7
13
NOTES:(THIS SHEET ONLY)
31
1 GENERAL: AFTER REMOVAL OF MECHANICAL SYSTEMS, PATCH AND PAINT ADJACENT WALL,
8 15 CEILING, FLOORS AND OTHER SURFACES TO MATCH EXISTING, UNLESS THESE SURFACES ARE
7 19 8
UH SHOWN TO BE REMOVED ON THE ARCHITECTURAL DRAWINGS. SEE ARCHITECTURAL DRAWINGS
9
S
9 9 21 FOR AREAS THAT ARE TO BE REPAINTED BY ARCHITECTURAL.
24 9
21
15 (TYP) 2 GENERAL: ALL DUCT SIZES, IF SHOWN ARE BASED ON ORIGINAL DRAWINGS AND HAVE NOT BEEN
36 VERIFIED. DUCT LOCATIONS SHOWN ARE APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY ALL
20 S EXISTING DUCT SIZES AND LOCATIONS.
21
8
S 31 3 GENERAL: CONTRACTOR SHALL PROVIDE WEATHER PROTECTION FOR ALL BUILDING OPENINGS
RESULTING FROM MECHANICAL EQUIPMENT REMOVAL.
R
21 21
20
14 13
14
20 4 GENERAL: FOR REMOVED THERMOSTATS, ALL CONTROL WIRING AND CONDUIT THAT IS
31 CONCEALED IN WALLS MY BE ABANDONED IN PLACE. ALL EXPOSED CONDUIT SHALL BE REMOVED.
CONTRACTOR SHALL BE ALLOWED TO REUSE WALL J-BOXES AND CONDUITS IF NEW THERMOSTATS
(TYP) ARE SHOWN INSTALLED IN EXACT SAME LOCATION AS REMOVED THERMOSTAT. SEE NEW WORK
(TYP)
8 FLOOR PLANS FOR LOCATION OF NEW THERMOSTAT. WHEN NO THERMOSTAT IS INSTALLED,
35
36 25 27 27 REMOVE J-BOX AND INFILL WITH MORTAR AND PAINT AS SPECIFIED. COVER PLATES WILL NOT BE CONSULTING
ALLOWED.
R ENGINEERS
D
20
21 28 34 5 GENERAL: CONTRACTOR SHALL REMOVE ALL SUPPORTS (BEAM CLAMPS, JOIST HANGERS, ANGLE
21
R IRON, UNISTRUT, DROP RODS, WALL BRACKETS, ETC.) FOR ALL REMOVED DUCTWORK, PIPING AND
17
D
17 G EQUIPMENT.
PHP'S
26 ANDREWS, HAMMOCK
6 GENERAL: SEE "GENERAL DEMOLITION" PARAGRAPH IN SPECIFICATION SECTION 230513
23
8
12 28 WH
32 KILN
CONCERNING GENERAL DEMOLITION. ALL DEMOLITION SHALL BECOME PROPERTY OF
CONTRACTOR AND SHALL BE LAWFULLY REMOVED FROM SITE.
& POWELL, INC.
T
PHP 41
39 250 Charter Lane
40
14 33 (TYP) 7 REMOVE EXISTING EXHAUST DUCT AND SUPPORTS FROM THIS APPROXIMATE LOCATION.
S
T T
38
Suite 100
28 36
29 8 REMOVE EXISTING CEILING SUPPLY GRILLE FROM THIS APPROXIMATE LOCATION. SEE NEW WORK
22
45 R Macon, Georgia 31210
DRAWINGS FOR INSTALLATION OF NEW GRILLE.
10 D
21
Phone: (478)405-8301
35 9 CONTRACTOR SHALL PROVIDE 26 GAUGE SHEET METAL PATCH PLATES. ATTACHED WITH SHEET
21 (TYP) METAL SCREWS AND FULL PERIMETER MASTIC. INSULATE WITH 2" DUCT WRAP INSULATION AND Fax: (478)405-8210
R
FSK TAPE. FIELD VERIFY EXACT PATCH SIZE.
16 D WWW.AHPENGR.COM
38 21
10 EXISTING THERMOSTAT TO REMAIN AT THIS APPROXIMATE LOCATION.
17
8 17 28
21 TC 11 EXISTING SIDEWALL EXHAUST FAN, HOUSING, DAMPERS, ETC., TO REMAIN AT THIS APPROXIMATE
LOCATION.
RG
12 REMOVE EXISTING THERMOSTAT FROM THIS APPROXIMATE LOCATION. SEE ALSO NOTE 4.
EO I
RE
S
GITERED
A
11 17
37 13 REMOVE EXISTING ROOF MOUNTED VENTILATOR AND ROOF CURB FROM THIS APPROXIMATE No. 17029
LOCATION. PROFESSIONAL
44 14
14 REMOVE EXISTING SIDEWALL SUPPLY GRILLE FROM THIS APPROXIMATE LOCATION. SEE NEW
EN
WORK DRAWINGS FOR INSTALLATION OF NEW GRILLE. NEER
GI
.
A
J
M
16 ES JR
14 A. ,
ANDREWS
11 14 43 8 15 REMOVE EXISTING SUPPLY DUCT, INSULATION AND SUPPORTS AS INDICATED UP TO SCOPE OF
8
8 WORK SYMBOL.
21
.
T
T.
T
15 16 REMOVE EXISTING SIDEWALL RETURN GRILLE FROM THIS APPROXIMATE LOCATION. SEE NEW
9 WORK DRAWINGS FOR INSTALLATION OF NEW GRILLE.
15 12
9 21 9
21 21 17 EXISTING RETURN DUCT, INSULATION AND SUPPORTS TO REMAIN AT THIS APPROXIMATE
9
17
LOCATION.
RENOVATION
8 18 EXISTING CEILING MOUNTED TRANSFER GRILLE TO REMAIN AT THIS APPROXIMATE LOCATION.
17
26
23
17
T
12
17
19 REMOVE EXISTING EXHAUST CEILING FAN FROM THIS APPROXIMATE LOCATION.
22 EXISTING PACKAGED HEAT PUMP AND SECURITY ENCLOSURE TO REMAIN AT THIS APPROXIMATE
TO NORTH
S
LOCATION.
22 15 8
45
21
37
21 37 37 30
23 EXISTING FABRIC DUCT AND SUPPORTS TO REMAIN AT THIS APPROXIMATE LOCATION. MACON
21 24 EXISTING GAS FIRED UNIT HEATER AND SUPPORTS TO REMAIN AT THIS APPROXIMATE LOCATION.
8
37
8
25 EXISTING LOUVER TO REMAIN AT THIS APPROXIMATE LOCATION.
PARK
26 EXISTING RETURN GRILLE TO REMAIN AT THIS APPROXIMATE LOCATION.
27 EXISTING HEAT PUMP AND ALL ASSOCIATED APPURTENANCES AND CONCRETE PAD(S) TO REMAIN
AT THIS APPROXIMATE LOCATION. PROVIDE BASELINE TAB REFRIGERANT PRESSURE READINGS TO
RECREATION
INSURE PROPER UNIT OPERATION. REPORT ANY DEFICIENCIES TO THE OWNER.
10
28 EXISTING VERTICAL FAN COIL UNITS AND ALL ASSOCIATED APPURTENANCES TO REMAIN AT THIS
APPROXIMATE LOCATION. PROVIDE BASELINE TAB AIRFLOW READING TO INSURE PROPER UNIT
OPERATION. REPORT ANY DEFICIENCIES TO OWNER.
CENTER
24
T 29 EXISTING OUTSIDE AIR DUCT AND SUPPORTS TO REMAIN AT THIS APPROXIMATE LOCATION.
UH 25 30 REMOVE EXISTING RANGE HOOD FROM THIS APPROXIMATE LOCATION. EXISTING RANGE WILL BE
REMOVED UNDER THIS PROJECT.
25
35 EXISTING CONDENSATE DRAIN PIPING TO REMAIN AT THIS APPROXIMATE LOCATION. ALL PIPING
RECREATION
NOT SHOWN FOR CLARITY.
38 REMOVE EXISTING TIME CLOCK IF IT SERVES HVAC EQUIPMENT. NEW THERMOSTATS WILL HAVE
BUILT IN TIME CLOCK FOR SCHEDULING PURPOSES.
MECHANICAL DEMOLITION FLOOR PLAN 40 REMOVE EXISTING SIDEWALL EXHAUST FAN FROM THIS APPROXIMATE LOCATION. PROVIDE PAINT
MACON, GA 31210
GRIP SHEET METAL TO COVER OPENING. PAINT TO MATCH INTERIOR AND EXTERIOR WALL COLORS.
SCALE: 1/8"=1'-0"
41 EXISTING ROOF CURB AND INTAKE VENTILATOR TO REMAIN AT THIS APPROXIMATE LOCATION.
42 REMOVE EXISTING CEILING RETURN GRILLE FROM THIS APPROXIMATE LOCATION. SEE NEW WORK REVISIONS
DRAWINGS FOR INSTALLATION OF NEW GRILLE.
44 EXISTING EXHAUST FAN STARTERS ARE LOCATED WHERE NEW DOORS WILL BE INSTALLED.
COORDINATE WITH OWNER REMOVAL OR RELOCATION OF EXISTING FAN STARTERS.
Date: 05/16/2016
ON DOCUM ENTS
Sheet Name:
Mechanical
Demolition Floor Plan
CONSTRUCTI
Sheet Number:
MD101
15
14"Ø
15
C C C
250 200 250
10"Ø 10"Ø
MP ROOM
10"Ø 14"Ø
119
14"Ø
11 18 10"Ø
17 C 15
250 10"Ø
10"Ø
R C
F 8"Ø 250
R
HP-1 C
14"Ø
200 12"Ø
8"Ø 16"Ø
12 16"Ø
10"Ø
FCU-1
MVD 24 X 24 10"Ø
T
19 6"Ø
22
10
28 14
26 16
20 X 8
3
4" D
EF-2 EF-1
20 20 X 8
A FCU-1
16"Ø 450
STORAGE
75 120 BPIU-1 13 450
6"Ø
21 TLT F
J
STORAGE 121
J
SHOWERS F
129 122
175 150
6"Ø
T
SHOWERS M
A 6"Ø 124
75 8"Ø
8"Ø 9
UH
9 9 9
S TLT M
123
NOTES:(THIS SHEET ONLY)
JAN. J 1 NEW DUCT MOUNTED SMOKE DETECTOR. PROVIDED AND WIRED BY ELECTRICAL BUT
118
S
2
150 INSTALLED BY MECHANICAL HVAC CONTRACTOR. DETECTOR SHALL BE MOUNTED IN DUCT
6"Ø
LOCATION AFTER SUPPLY DUCTS ARE TWINNED TOGETHER.
EF-3
S
2 NEW SUPPLY GRILLE SHALL BE REBALANCED FOR INDICATED AIRFLOW AND RECONNECTED CONSULTING
R
TO EXISTING DUCT. CONTRACTOR SHALL PROVIDE ANY NECESSARY DUCT TRANSITIONS
2
I 2
I VEST.
125 AND EXTENSIONS FOR CONNECTION FROM EXISTING FLEX/DUCT TO NEW SUPPLY GRILLE
ENGINEERS
A 450 75 450 CONNECTION.
75
1 3 MOUNT 36 X 36 SIDEWALL TRANSFER GRILLE WITH TOP ELEVATION AT 14'-8" A.F.F.
2 ANDREWS, HAMMOCK
S
COORDINATE EXACT LOCATION OF GRILLE WITH THE NEW TECTUM PANELS. SEE
3 3 EXISTING HP-A&B
G G EXISTING ARCHITECTURAL PLANS FOR EXACT LOCATIONS.
2
36 X 36 FCU-A&B
EXISTING HP-C&D 4 CONTRACTOR SHALL PROVIDE NEW 24 X 24 LINED (12" LINER) PLENUM ATOP NEW
& POWELL, INC.
B EGGCRATE RETURN GRILLE. EXISTING 15 X 12 DUCT (FIELD VERIFY SIZE) SHALL BE 250 Charter Lane
150 G G 36 X 36 MODIFIED TO TAP INTO TOP OF THE NEW PLENUM ATOP THE NEW RETURN GRILLE.
G Suite 100
OFC.
117 3 3
I 5 CONTRACTOR SHALL TAP NEW 18 X 8 SUPPLY DUCT TO THE EXISTING MAIN SUPPLY DUCT Macon, Georgia 31210
AT THIS APPROXIMATE LOCATION. CONTRACTOR SHALL ROUTE THE DUCT TO THE NEW
450 AK
126 WH SUPPLY GRILLE AND PROVIDE NECESSARY DUCT OFFSETS. BALANCE GRILLE FOR Phone: (478)405-8301
KILN
INDICATED AIRFLOW. CONTRACTOR SHALL MOUNT BOTTOM ELEVATION OF THE GRILLE
PHP 2 Fax: (478)405-8210
23 11'-11" A.F.F. COORDINATE EXACT LOCATION OF GRILLE WITH THE NEW TECTUM PANELS.
KILNS
10 24 26
T T T
STORAGE 115 SEE ARCHITECTURAL PLANS FOR EXACT LOCATIONS. WWW.AHPENGR.COM
S 113
E 6 MOUNT NEW THERMOSTAT WITH BOTTOM ELEVATION 4'-6" A.F.F. PROVIDE REMOTE SPACE
TEMPERATURE SENSOR AS SHOWN AND CONNECT TO THERMOSTAT.
2 2
EXISTING D
B 7 CONTRACTOR SHALL EXTEND RETURN DUCT(S) (AS REQUIRED) AND MOUNT THE NEW RG
EO
GATHERING AREA
HP/FCU-A&B
105
E 500 I
RETURN GRILLES IN SAME LOCATION. ENGINEER WAS UNABLE TO FIELD MEASURE RETURN S
GIT
150 RE
ERED
A
GRILLE DIMENSIONS. GRILLE DIMENSIONS ARE APPROXIMATELY 30 X 18 (EACH) BUT
MP ROOM CONTRACTOR SHALL FIELD VERIFY EXACT SIZES PRIOR TO ORDERING NEW GRILLES.
OFC. 112 No. 17029
7
116
PROFESSIONAL
8 CONTRACTOR SHALL TAP NEW 8"Ø BELLMOUTH WITH DAMPER OUT THE BOTTOM OF THE
S
EXISTING MAIN SUPPLY DUCT TO A NEW SUPPLY GRILLE AS SHOWN. BALANCE GRILLE FOR
INDICATED AIRFLOW.
EN
EXISTING 1 NEER
GI
.
A
J
M
I ES JR
FCU-C&D 9 CONTRACTOR SHALL TAP NEW BELLMOUTH WITH DAMPER OF INDICATED SIZE OUT OF THE A. WS
,
ANDRE
9 450 E EXISTING MAIN SUPPLY DUCT TO A NEW SUPPLY GRILLE(S) AS SHOWN. BALANCE GRILLE(S)
2 2 FOR INDICATED AIRFLOW.
C CRAFT C
EQUIP. 114
128 2 350 350
GYMNASIUM 10 MOUNT NEW THERMOSTAT WITH BOTTOM ELEVATION 4'-6" A.F.F.
127 E
EXISTING HP/FCU-C&D
A 12"Ø 25 11 NEW HEAT PUMP. SEE HEAT PUMP/CONDENSING UNIT DETAIL.
2 90
H
550
H
550
H
550
7 12 NEW CONCRETE PAD. SEE CONCRETE PAD DETAIL. RENOVATION
13 NEW VERTICAL FAN COIL UNIT. SEE VERTICAL FAN COIL UNIT AND BIPOLAR IONIZATION
RS UNIT DETAILS.
8
18 X 8 T 18 X 8 18 X 8
14 FILTER RACK. SEE FILTER RACK DETAIL.
& ADDITION
5 5 5
6"Ø VEST. 15 14"Ø EXHAUST DUCT IS ROUTED TO TRIANGULAR GABLE ROOF VENT AT THIS APPROXIMATE
A
130
8" DROP B
140
6 24 26
2
B
140
111
LOCATION. PROVIDE SHEET METAL BLANK-OFF TO CONNECT DUCT TO GABLE VENT AS
REQUIRED. SEE ARCHITECTURAL PLANS FOR EXACT GABLE VENT LOCATION.
TO NORTH
RECEPT.
104
16 FLOOR DRAIN. SEE PLUMBING DRAWINGS FOR EXACT LOCATION.
10"Ø
CORR.
101
F F
C
2 17 PIPE SLEEVE. SEE REFRIGERANT PIPE SLEEVE DETAIL. MACON
PHP 350 18 REFRIGERANT PIPE SHALL BE ROUTED IN A NEAT WORKMANLIKE MANNER TO ASSOCIATED
S
10"Ø
12"Ø
C
300
4
INDOOR/OUTDOOR EQUIPMENT. SUSPEND PIPE WITH PIPE HANGERS. SEE PIPE HANGER
DETAIL. PARK
KITCHEN
C C 108
19 14 X 14 EGGCRATE (PRICE MODEL 82) MOUNTED IN SOFFIT. PROVIDE INSECT SCREEN ON
TROPHY CASE
103
C
375 2
MTG ROOM
106
375 2
BACKSIDE OF EGGCRATE.
20 CONDENSATE TRAP. SEE CONDENSATE TRAP DETAIL. ROUTE34" PVC CONDENSATE PIPE
RECREATION
300
TO FLOOR DRAIN.
VEST.
100
21 SUPPLY DUCT FROM NEW FAN COIL UNIT RISES AND TRANSITIONS TO 16"Ø DUCT. DUCT
SHALL BE ROUTED THRU ACT CEILING (NEATLY FINISH OFF PENETRATION AT CEILING) AND
CENTER
OFFSETS AS REQUIRED TO FIT THRU BOTTOM CHORD(S) OF TRUSSES INTO ATTIC SPACE.
STORAGE ELEC. CONTRACTOR SHALL COORINDATE EXACT DUCT ROUTING BASED ON CROSS
C C 107 110
BRACING/PLACEMENT OF THE TRUSS SYSTEM.
375 2
375 2 PANTRY
109
22 RETURN DUCT OF INDICATED SIZE FROM NEW FAN COIL UNIT RISES FROM RETURN AIR
PLENUM/DUCT AND IS THEN ROUTED THRU ACT CEILING (NEATLY FINISH OFF PENETRATION
AT CEILING) AND OFFSETS AS REQUIRED TO FIT THRU BOTTOM CHORD(S) OF TRUSSES
INTO ATTIC SPACE. CONTRACTOR SHALL COORDINATE EXACT DUCT ROUTING BASED ON
CROSS BRACING/PLACEMENT OF THE TRUSS SYSTEM.
T
UH
23 BALANCE EXISTING OUTSIDE AIR DUCT FOR 350 CFM AT EACH CONNECTION. PROVIDE MVD
AT CONNECTION TO RETURN DUCT TO BALANCE AIRFLOW. BIBB COUNTY
24 PROVIDE CARRIER EDGE PRO 33CS THERMOSTAT (OR EQUAL) TO PROVIDE APPROPRIATE
NUMBER OF COOLING/HEATING STAGES TO CONTROL EXISTING SYSTEMS. SEE CONTROL RECREATION
SEQUENCE OF OPERATION IN SPECIFICATION FOR MORE DETAILED INFORMATION.
PROGRAMMABLE THERMOSTAT SHALL SERVE AS TIMECLOCK AND SCHEDULE. DO NOT
ROUTE LOW VOLTAGE THRU EXISTING TIMECLOCK. PROVIDE NEW CONTROL WIRING AS DEPARTMENT
REQUIRED TO ACCOMPLISH THIS.
25 PROVIDE OPTIONAL REMOTE SPACE TEMPERATURE SENSOR FOR EDGE PRO THERMOSTAT.
26 PROVIDE OPTIONAL REMOTE OUTSIDE AIR TEMPERATURE SENSOR FOR EDGE PRO
THERMOSTAT TO DISPLAY OUTSIDE AIR TEMPERATURE AT THERMOSTAT.
27 GENERAL: ALL ROUND DUCT TAKEOFFS FROM MAIN ROUND OR RECTANGULAR DUCTS 815 N MACON PARK DR
SHALL BE IN ACCORDANCE WITH BELLMOUTH OR 90º SADDLE TAP TAKEOFF DETAILS.
MACON, GA 31210
28 PROVIDE RECTANGULAR TO ROUND ADAPTER ATOP RETURN GRILLE. SEE DETAIL.
Date: 05/16/2016
ON DOCUM ENTS
Sheet Name:
Mechanical New
Work Floor Plan
CONSTRUCTI
Sheet Number:
M101
OUTLINE OF HVAC UNIT.
" )
‚
- ANS
A. PL
PIPE HANGER. SEE SPECS.
DI EE
(S RETURN DUCT/ FOR TYPE. PIPING
PLENUM
BUTT AND WELD (TYPICAL)
3"
INHIBITIVE PAINT ON ALL METAL 2 X 2 X14ALL WELDED
3"
COMPONENTS. ANGLE IRON FRAME WITH 2 COATS
OF RUST PROHIBITIVE PAINT
A
SECURE INNER DUCT TO FITTING WITH NYLON ZIP No. 17029
PROVIDE SECURITY ENCLOSURE FOR OPENING IN SIDE OF RECTANGULAR SHEET METAL
STRIPBAND. IN ADDITION TO NYLON STRIPBAND, PROFESSIONAL
OUTDOOR UNIT. SEE SPECIFICATIONS DUCT SHALL BE CUT WITH DRILL-CUTTER OR TIN
MAINTAIN MANUFACTURERS RECOMMENDED SEAL INNER CORE TO DUCT WITH DUCT TAPE.
AND SCHEDULE FOR EXACT REQUIREMENTS. SNIPS. DIAMETER OF OPENING SHALL MATCH
CLEARANCE FOR SERVICE AND AIRFLOW INNER DIAMETER OF FOAM GASKET OR DIAMETER
EN
(AS A MINIMUM, MAINTAIN 24" BETWEEN NEER
GI
.
RECOMMENDED BY TAKEOFF MANUFACTURER. A
J
M
ES JR
UNITS AND 30" FROM UNIT TO WALL.) A. ,
ANDREWS
FLEXIBLE DUCTWORK R-8 DUCT WRAP INSULATION FOR SUPPLY AND RETURN DUCT
R
SHALL THEN BE COVERED WITH ALUMINUM R
L
INSTALL LEVEL. ANCHOR TO CONCRETE 112"
S
PARK
R
PIPE NIPPLE
LIQUID AND SUCTION LINE CHARGING/SERVICE SCALE: NONE
PIPE CLAMP. PROVIDE FOR REFRIGERANT VALVES AT UNIT.
PIPING, CONTROL CONDUIT, AND POWER
CONDUIT. PROVIDE BAKED ENAMEL FINISH.
PROVIDE ELASTOMERIC CUSHION AROUND
LIQUID-TITE FLEX CONTROL
CONDUIT AT UNIT
CONDENSATE DRAIN TRAP DETAIL RECREATION
REFRIGERANT LIQUID PIPING.
SCALE: NONE
PIPING ARRANGEMENT IS ILLUSTRATIVE
SEE FLOOR PLANS FOR QUANTITY OF
UNISTRUT CHANNEL. PROVIDE SUFFICIENT LENGTH FOR
QUANTITY OF PIPES AND CONDUIT MOUNTED ON CHANNEL.
CENTER
UNITS, EXACT REFRIGERANT PIPE ANCHOR UNISTRUT TO CONCRETE PAD. PROVIDE BAKED
ROUTING, ETC. ENAMEL FINISH.
TO 24VAC FAN
WITH WALL
EXTERIOR PAINTABLE SILICON CAULK.
BIBB COUNTY
TERMINALS AT
PAINT TO MATCH EXTERIOR
FCU 20 GAUGE GALVANIZED
STEEL SHEET METAL
EXTERIOR WALL. SEE ARCHITECTURAL PLANS FOR CONSRTUCTION.
RECREATION
SLEEVE
NEEDLEPOINT ELECTRODES
REFRIGERANT PIPE DROPS
DEPARTMENT
IN WALL AS REQUIRED
BI-POLAR IONIZATION UNIT MOUNTED
INSIDE UNIT IN SUPPLY AIRSTREAM.
REVISIONS
POWER CONDUIT (BY ELEC.)
BI-POLAR IONIZATION CONTROL DETAIL INSULATED REFRIGERANT
SUCTION PIPE
UNINSULATED REFRIGERANT LIQUID PIPE
8"Ø
FLOOR SLAB
ON DOCUM ENTS
SCALE: NONE
FOR SUPPLY DUCTS, INSULATE ENTIRE FITTING (EXCEPT OPERATOR HANDLE) Sheet Name:
WITH 3" THICK DUCTWRAP SEALED WITH FSK TAPE TO FLEX DUCT VAPOR
CONSTRUCTI
Sheet Number:
SCALE: NONE
M501
FAN COIL UNITS FILTERS LEGEND
CARRIER TOTAL SENSIBLE TOTAL INT. AUX. APPROX. BLOWER CAMFIL FARR MAXIMUM PRESSURE DROP
ENTERING AIR TEMP.
OA FILTER
FILTER MODEL APPLICATION DROP @ INITIAL FACE VELOCITY
ASHRAE FILTER
NOTES:
A
TAG MODEL NET COOLING NET COOLING SUPPLY HTG. CAP. HTG. ESP MOTOR NOTES: GRILLE, REGISTER, DIFFUSER DESIGNATION ABOVE WITH CFM SHOWN BELOW FOR TAB AGENT TO BALANCE DEVICE AT
CFM TYPE MERV THICKNESS
NUMBER MBH MBH CFM MBH KW @208 IN. WG HP °FDB °FWB NUMBER 500
PD IN WG FPM
FCU-1 FV4C 44 32 1400 200 24 7.5 0.70 3/4 78 65 1:2:3:4:5:6:7:8:9:10:11 PLEATED AERO PLEAT FCU-1 .23 500 7 1" 1:2:3:4 16 X 12 DUCT SIZE: FIRST DIMENSION IS SIDE DRAWN
1. VERTICAL DRAW THRU FAN COIL UNIT WITH SINGLE WALL CONSTRUCTION AND 1" THICK R4.2 INTERIOR INSULATION, PROVIDE BAKED ENAMEL FINISH. SEE VERTICAL FCU DETAIL.
1. UL CLASS 2, MEDIUM EFFICIENCY, COTTON AND SYNTHETIC MEDIA FILTER. RIGID ROUND DUCTWORK OR FLUE PIPING
2. COOLING CAPACITIES BASED ON AIR ENTERING EVAPORATOR AT SCHEDULED CONDITIONS AND MATCHED WITH INDICATED HEAT PUMP UNIT. FLEXIBLE ROUND DUCTWORK
2. PROVIDE RIGID HEAVY DUTY FRAME BONDED TO MEDIA WITH WELDED WIRE PLEATED SUPPORT GRID TO MAINTAIN RADIAL PLEAT.
3. HEATING CAPACITY BASED ON 70°F RETURN AIR AND OUTDOOR AIR AT 17°F, AND MATCHED WITH INDICATED HEAT PUMP UNIT. RECTANGULAR - TO - ROUND DUCT TRANSITION
3. FILTER MINIMUM EFFICIENCY REPORTING VALVE (MERV) RATING BASED ON EVALUATION IN ACCORDANCE WITH ASHRAE STANDARD 52.2-1999.
4. PROVIDE DX COOLING COIL WITH FACTORY INSTALLED THERMOSTATIC EXPANSION VALVE FOR REFRIGERANT CONTROL. FLEXIBLE CONNECTION
4. CONTRACTOR SHALL PROVIDE 1 EXTRA SET OF FILTERS FOREACH NEW UNIT, IN ADDITION TO THE CLEAN FILTERS INSTALLED IN THE UNIT WHEN TURNED OVER TO THE OWNER.
5. SCHEDULED CAPACITIES ARE OVERALL CAPACITIES FOR MATCHED HEAT PUMP UNIT AND EVAPORATOR COIL WITH 2°F LINE LOSS. ACOUSTICAL/THERMAL DUCT LINER -12" THICK OR 1" THICK, RESPECTIVELY
6. EXTERNAL STATIC PRESSURE SCHEDULED DOES NOT INCLUDE WET COOLING COIL, CASING, ELECTRIC HEAT COIL OR FILTER LOSSES. BLOWER MOTOR MUST OVERCOME E.S.P. AT CONNECTED VOLTAGE. SQUARE ELBOW WITH TURNING VANES
7. PROVIDE UNIT MOUNTED FACTORY PROVIDED FIELD INSTALLED ELECTRIC STRIP HEATERS OF INDICATED KW AT CONNECTED VOLTAGE. PROVIDE SINGLE POINT UNIT POWER CONNECTION FOR ENTIRE UNIT. 45° BRANCH ENTRY FITTING
9. PROVIDE DOUBLE SLOPED REMOVABLE CONDENSATE DRAIN PAN. PROVIDE TRAPPED CONDENSATE DRAIN. SEE CONDENSATE DRAIN TRAP DETAIL. GREENHECK FAN STATIC FD FIRE DAMPER.
MAX
TAG MODEL CFM PRESSURE FAN RPM MOTOR HP NOTES:
SONES
10.PROVIDE VARIABLE SPEED ECM SUPPLY FAN MOTOR. NO. IN W.G. FD/SD COMBINATION MOTORIZED FIRE/SMOKE DAMPER.
11.PROVIDE CARRIER THERMIDISTAT PERFORMANCE EDGE MODEL TP-PRH-01 PROGRAMMABLE TEMPERATURE/HUMIDITY CONTROLLER. THERMOSTAT/CONTROLLER SHALL BE PROVIDED BY EQUIPMENT MANUFACTURER. EF-1 SPA-700 450 0.30 1100 350 WATTS 2.5 1:2:3:4 MVD MVD MANUAL VOLUME DAMPER (OPPOSED BLADE)
EF-2 SPA-700 450 0.30 1100 350 WATTS 2.5 1:2:3:4 AVD AVD AUTOMATIC VOLUME DAMPER (POWERED OPEN, SPRING CLOSE)
EF-3 SP-B90 75 0.25 700 50 WATTS 2.5 1:2:3:4 AP ACCESS PANEL IN SIDE OF DUCT
DOOR GRILLE
2. DIRECT DRIVE.
BELLMOUTH TAKE-OFF COLLAR AT RUN-OUT W/BALANCING DAMPER. SEE BELLMOUTH AND 45° FITTING TAKEOFF DETAIL.
3. PROVIDE FACTORY MOUNTED DISCONNECT SWITCH.
90° ROUND SADDLE TAP TAKEOFF WITH BALANCING DAMPER. SEE 90° SADDLE TAP FITTING DETAIL.
4. PROVIDE SPEED CONTROLLER.
TAG
PRICE
MODEL
SIZE
OR FINISH THROW NOTES:
RETURN OR EXHAUST AIR FLOW
ANDREWS, HAMMOCK
NUMBER LENGTH M SPACE MOTION SENSOR
H HUMIDISTAT
& POWELL, INC.
A SCD 6"Ø WHITE 4-WAY 1:5:7:8:12
250 Charter Lane
T THERMOSTAT WITH LOCKING PLASTIC OR METAL COVER AS SPECIFIED
B SCD 8"Ø WHITE 4-WAY 1:5:7:8:12 Suite 100
T CONVENTIONAL SPACE THERMOSTAT (NON-DDC)
C SCD 10"Ø WHITE 4-WAY 1:5:7:8:12 Macon, Georgia 31210
S DUCT MOUNTED SMOKE DETECTOR (PROVIDED AND WIRED BY ELEC. AND INSTALLED BY MECH.)
G 95 36 X 36 PRIMECOAT ----- 6:7:11:13
A
4:6:7:10:13
PROFESSIONAL
PIPE SLEEVE THRU WALL OR FLOOR. SEE PIPE SLEEVE DETAIL.
1. LOUVERED FACE SQUARE 4-CONE STEEL CEILING SUPPLY DIFFUSER WITH FIXED AIR 360º DISCHARGE PATTERN AS SCHEDULED. PROVIDE FULL FACED LOUVERS. PROVIDE FACTORY INSULATED
BACKPAN. DROPPING OR RISING PIPE EN
NEER
GI
.
A
J
M
ES JR
2. LOUVERED FACE HIGH CAPACITY STEEL CEILING SUPPLY DIFFUSER WITH FIXED AIR DISCHARGE PATTERN AS SCHEDULED. PIPE TO OR FROM ABOVE A. ,
ANDREWS
3. ALL ALUMINUM12" X12" X12" EGG CRATE EXHAUST/RETURN GRILLE. ISOLATING BALL VALVE<2", BUTTERFLY VALVE 2" >
SS
DRY BULB, WET BULB
STAINLESS STEEL
& ADDITION
9. CORE ONLY PANEL.
10. DOUBLE DEFLECTION SIDEWALL GRILLE WITH34" BLADE SPACING AND FRONT BLADES PARALLEL TO THE LONG DIMENSION.
FPM
CFM,c
f
FEET PER MINUTE
TAG
CARRIER
MODEL
TOTAL NET
COOLING
MINIMUM
STAGES
MINIMUM COOLING
AMBIENT
OPERATING
REVERSE CYCLE
HEATING NOTES:
AFF ABOVE FINISHED FLOOR
CENTER
NO. MBH CAPACITY MBH @ 17ºF UC UNDERCUT DOOR34"
TEMP °F
2. ALL REFRIGERANT LINES TO BE INSTALLED AND SIZED PER MANUFACTURER'S INSTALLATION RECOMMENDATIONS. Δt TEMPERATURE DIFFERENCE
3. SCHEDULED CAPACITIES ARE OVERALL CAPACITIES REQUIRED FOR MATCHED HEAT PUMP AND EVAPORATOR COIL WITH 2°F SUCTION LINE LOSS. B.E. T.E. BOTTOM ELEVATION, TOP ELEVATION
4. PROVIDE INTEGRAL CONTROLS INCLUDING CONTACTORS, CRANKCASE HEATER, 5 MINUTE COMPRESSOR TIME DELAY RELAY AND COMPRESSOR OVER TEMPERATURE (OVERLOAD) LIMIT OF SCOPE OF WORK
PROTECTION.
SECTION OR DETAIL IDENTIFICATION NUMBER
BIBB COUNTY
5. PROVIDE ALL CONTROLS, ACCESSORIES AND SYSTEM MODIFICATIONS TO PERMIT COOLING OPERATION TO SPECIFIED TEMPERATURE. PROVIDE OA TEMPERATURE SENSOR TO 2
DISPLAY OA TEMPERATURE ON THERMOSTAT, AUXILLARY HEAT LOCKOUT, ETC.
M1
SHEET NUMBER ON WHICH SECTION OR DETAIL IS DRAWN
RECREATION
6. PROVIDE LIQUID AND SUCTION LINE SERVICE VALVES/GAUGE PORTS.
12.PROVIDE ELECTRONIC ECM CONDENSER FAN MOTOR. 3. COORDINATE LOCATION OF CEILING REGISTERS WITH LIGHTING LAYOUT, SPRINKLER HEADS AND CEILING GRID SYSTEMS AND APPURTENANCES. REFER TO ARCHITECTURAL REFLECTED
MACON, GA 31210
CEILING PLANS FOR EXACT LOCATION.
13.PROVIDE PROTECTIVE/SECURITY ENCLOSURE DESIGNED AND FABRICATED BY MGM PRODUCTS, PROPERTY ARMOR, OR ALADDIN SHEET METAL, INC. SEE SPECIFICATIONS.
4. DUCT SIZES INDICATED ON THE PLANS ARE CLEAR INSIDE DIMENSIONS REQUIRED.
5. REFER TO THE ELECTRICAL DRAWINGS FOR VOLTAGE, PHASE, MAXIMUM ALLOWABLE CURRENT DRAW AMPERAGE AND CONNECTION ARRANGEMENT (SINGLE OR MULTI-POINT CONNECTION, REVISIONS
ETC.) OF ALL MECHANICAL EQUIPMENT PRIOR TO ORDERING/INSTALLING EQUIPMENT.
# DATE DESCRIPTION
BI-POLAR IONIZATION UNITS 6. SUPPORT ALL DUCTS, PIPING AND EQUIPMENT FROM PRIMARY BUILDING STRUCTURAL MEMBERS AND PROVIDE SUPPLEMENTAL STRUCTURAL FRAMING AS REQUIRED BETWEEN PRIMARY
BUILDING STRUCTURAL MEMBERS TO SUPPORT ALL SYSTEMS INSIDE THE BUILDING.
GLOBAL 7. PROVIDE STRUCTURAL FRAMING AROUND FULL PERIMETER OF ALL ROOF OPENINGS/EQUIPMENT. PROVIDE STRUCTURAL LINTELS ABOVE ALL WALL OPENINGS. SEE STRUCTURAL FOR LINTEL
ASSOCIATED
TAG CFM PLASMA NOTES: DETAILS OR REINFORCEMENT DETAILS.
EQUIPMENT
SOLUTIONS
8. PROVIDE PIPE SLEEVE THRU ALL WALLS AND THRU ALL FLOOR SLABS. SEE PIPE SLEEVE DETAIL.
1. NEEDLE POINT TYPE IONIZER WITH ABS PLASTIC HOUSING, AND CARBON
FIBER NEEDLES.
Date: 05/16/2016
ON DOCUM ENTS
Sheet Name:
Mechanical Legend,
General Notes &
Schedules
CONSTRUCTI
Sheet Number:
M601
PLUMBING LEGEND
SOIL OR WASTE PIPING
VENT PIPING
1
BALL VALVE (2" & SMALLER) OR BUTTERFLY VALVE (2 2" & LARGER)
1 2 2 5
DIELECTRIC UNION
POINT OF CONNECTION
8 MODIFY EXISTING WATER PIPING IN CHASE AS REQUIRED TO PROVIDE WATER TO FIXTURES AS SPECIFIED.
RG
9 CONNECT NEW •" HOT AND COLD WATER PIPING TO EXISTING AT THIS APPROXIMATE LOCATION ABOVE CEILING.
EO I
RE
S
GITERED
A
FIXTURE CONNECTION SCHEDULE 10 EXISTING WALL HYDRANT TO BE REMOVED. SEE NEW WORK PLAN BELOW FOR NEW WALL HYDRANT. No. 17029
PROFESSIONAL
ƒ "
COLD WATER HOT WATER WASTE MP ROOM
RIM 11 EXTEND PIPING SERVING EXISTING WALL HYDRANT TO NEW WALL HYDRANT AS SHOWN. 119
MARK FIXTURE NOTES
HEIGHT EN
BRANCH CONN. BRANCH CONN. BRANCH CONN. 12 CONNECT NEW 2" VENT PIPING TO EXISTING VENT PIPING ABOVE CEILING. MODIFY EXISTING VENT NEER
GI
.
A
J
M
7 ES JR
PIPING AS REQUIRED FOR CONNECTION. 12 A.
EWS
,
P-1 WATER CLOSET 1 15" 1" 1" ---- ---- 4" 4" ANDR
P-2 WATER CLOSET 1,3 18" 1" 1" ---- ---- 4" 4"
3" F.D. 'B'
3 3 8 P-2
P-3 URINAL 2,3 16" " " ---- ---- 2" 2"
4 4
STORAGE
1 1 1 1 120 P-2 8
P-4 SERVICE SINK ---- ---- " " " " 2" 2"
2 2 2 2
8 P-1
7 RENOVATION
1. FLOOR MOUNTED, FLUSH VALVE.
TO NORTH
124
TLT F 5
9 121
6 P-1 P-3 6
STORAGE TLT M
129
5 5
6 P-1
5
123
5
MACON
P-4
6
JAN.
118
PARK
VEST.
5
FLUSH VALVE
TAILPIECE
SUPPORT
125
RECREATION
2"
STANDARD W.C. = 24"
CENTER
HANDICAP W.C. = 12"
OFC.
WALL 117
BIBB COUNTY
KILNS
GATHERING AREA
STORAGE
113
115
RECREATION
105
OFC.
116 MP ROOM DEPARTMENT
WATER CLOSET FLUSH VALVE MOUNTING DETAIL 112
SCALE: NONE
RECEPT.
104
TROPHY CASE
103
MTG ROOM
106
FLUSH VALVE ANCHOR VEST.
100
SCALE: NONE
STORAGE ELEC.
107 110
PANTRY
109
Date: 05/16/2016
ON DOCUM ENTS
SCALE: 1/8"=1'-0"
Sheet Name:
NOTE: CUT AND PATCH FLOORS AS REQUIRED FOR NEW WORK. PLUMBING DEMOLITION
AND NEW WORK PLANS,
DETAILS, SCHEDULE AND
LEGEND
CONSTRUCTI
Sheet Number:
P101
NOTES:(THIS SHEET ONLY)
1 REMOVE CEILING FAN AND TRACK LIGHTS. REMOVE POWER CIRCUIT, WIRE & CONDUIT BACK TO
SOURCE OF POWER.
2 SEE NEW WORK LIGHTING PLAN FOR ADDITIVE ALTERNATES #2 & #6 TO REPLACE SELECTED
LIGHT FIXTURES WITH NEW FIXTURES/CIRCUITS.
S
3 REMOVE RECESSED CAN LIGHTS OVER RECEPTION DESK LOCATION. REMOVE CIRCUIT, WIRE &
S
CONDUIT BACK TO SOURCE OF POWER.
CONSULTING
ENGINEERS
ANDREWS, HAMMOCK
& POWELL, INC.
250 Charter Lane
Suite 100
Macon, Georgia 31210
Phone: (478)405-8301
Fax: (478)405-8210
WWW.AHPENGR.COM
S
S
RG
EO I
RE
S
GITERED
A
1
No. 17029
PROFESSIONAL
EN
NEER
GI
SSSS
.
A
J
M
ES JR
A. ,
ANDREWS
RENOVATION
S
S
3 S S S
& ADDITION
TO NORTH
MACON
S
NOTE TO CONTRACTOR PARK
S
S
CONCERNING
S
PROJECT PHASING
RECREATION
THE WORK SPECIFIED ON THE DRAWINGS AND SPECIFICATIONS ILLUSTRATES THE
COMPLETED CONTRACTUAL REQUIREMENTS. THIS PROJECT IS PHASED IN MULTIPLE PHASES.
CENTER
THE AREA OF EACH PHASE IS DESCRIBED IN THE ARCHITECTURAL DOCUMENTS AND THE
CONTRACTOR SHALL REVIEW THESE PHASING REQUIREMENTS. CONTRACTOR
SHALL INCLUDE IN HIS BID ALL COSTS REQUIRED TO ACCOMPLISH THE CONTRACT IN PHASES.
THE CONTRACT DOCUMENTS DO NOT DESCRIBE THE SPECIFIC WORK REQUIRED BY THE
CONTRACTOR TO PERFORM THE PROJECT IN PHASES, BUT CONTRACTOR SHALL PREPARE
PHASING PLAN AND SUBMIT TO ARCHITECT/ENGINEER.
EXISTING CIRCUITS UTILIZE CONDUIT SYSTEM FOR GROUNDING PATH. CONTRACTOR SHALL # DATE DESCRIPTION
TEST AND VERIFY OHMIC VALUE FOR CONTINUITY OF THIS GROUNDING PATH. IF THE
EXISTING GROUNDING PATH IS DETERMINED TO BE NON-CONTINUOS, THE CONTRACTOR
ELECTRICAL LIGHTING EXISTING CONDITIONS DEMOLITION FLOOR PLAN SHALL REMEDY THAT BY PROVIDING #12 GROUNDING CONDUCTOR IN EXISTING CONDUIT.
SCALE: 1/8"=1'-0" CONTRACTOR SHALL ROUTE ALL NEW CONDUIT CONCEALED WHERE POSSIBLE. EXISTING
SWITCH LOCATIONS MAY BE UTILIZED WHERE CONDUIT IS ACCESSIBLE AND MOUNTING
HEIGHT IS 48". SWITCHES SHALL BE INSTALLED CONCEALED WITHIN NEW WALLS.
SWITCHES INSTALLED ON EXISTING WALLS SHALL BE SURFACE MOUNTED WITH SURFACE
METAL RACEWAY INSTALLED TO ABOVE ACCESSIBLE CEILING. PER DETAIL.
Date: 05/16/2016
ON DOCUM ENTS
Sheet Name:
Electrical Lighting
Demolition Floor Plan
CONSTRUCTI
Sheet Number:
ED101
2
NOTES:(THIS SHEET ONLY)
1 REMOVE EXISTING RANGE HOOD CIRCUIT FROM THIS APPROXIMATE LOCATION. EXISTING RANGE
SHALL BE REMOVED UNDER THIS PROJECT. LABEL CIRCUIT BREAKERS AS 'SPARE'.
2 REMOVE POWER CIRCUIT FOR EXISTING EXHAUST FANS BACK TO SOURCE OF POWER. LABEL
CIRCUIT BREAKERS AS 'SPARE'.
4 GENERAL NOTE: ALL EXISTING POWER AND LOW VOLTAGE DEVICES IN AREAS OF WORK SHALL
MEET SPECIFIED/ADA MOUNTING HEIGHTS AND ALL DEVICES/COVER PLATES SHALL BE REPLACED
WITH NEW DEVICES, UNLESS NOTED OTHERWISE, AND COVER PLATES. IF ANY CONDUIT, WIRE AND
OUTLET BOXES ARE REUSED THEY SHALL MEET CONTRACT DOCUMENTS. SEE ALSO
2
SPECIFICATION 260501 - ELECTRICAL DEMOLITION. LIGHT SWITCHES AND FIRE ALARM PULL
STATIONS SHALL BE AT 48" A.F.F. FIRE ALARM STROBES SHALL BE MOUNTED AT 80" A.F.F. SEE
SPECIFICATIONS FOR OTHER MOUNTING HEIGHT REQUIREMENTS.
CONSULTING
ENGINEERS
WP
GFI
ANDREWS, HAMMOCK
& POWELL, INC.
250 Charter Lane
Suite 100
Macon, Georgia 31210
Phone: (478)405-8301
Fax: (478)405-8210
WWW.AHPENGR.COM
RG
EO I
RE
S
GITERED
A
No. 17029
PROFESSIONAL
EN
NEER
GI
.
A
J
M
ES JR
A. ,
ANDREWS
RENOVATION
& ADDITION
TO NORTH
1
MACON
PARK
FACP
RECREATION
TBB LA
MTV
CENTER
BIBB COUNTY
RECREATION
DEPARTMENT
REVISIONS
# DATE DESCRIPTION
ELECTRICAL POWER EXISTING CONDITIONS DEMOLITION FLOOR PLAN
SCALE: 1/8"=1'-0"
Date: 05/16/2016
ON DOCUM ENTS
Sheet Name:
Electrical Power
Demolition Floor Plan
CONSTRUCTI
Sheet Number:
ED201
TYPICAL
CCTV
F ML
F
CCTV
F
DEMOLITION. LIGHT SWITCHES AND FIRE ALARM PULL STATIONS SHALL BE AT 48" A.F.F. FIRE ALARM
F
M
STROBES SHALL BE MOUNTED AT 80" A.F.F. SEE SPECIFICATIONS FOR OTHER MOUNTING HEIGHT
REQUIREMENTS.
6 5 REMOVE DOOR RELEASE SWITCH AND REINSTALL PER NEW WORK PLANS.
6 CCTV HEAD END AND DISPLAY RELOCATE PER NEW WORK PLANS.
ANDREWS, HAMMOCK
CCTV
& POWELL, INC.
RTE
250 Charter Lane
S
Suite 100
Macon, Georgia 31210
S S
Phone: (478)405-8301
RTE
H Fax: (478)405-8210
WWW.AHPENGR.COM
RG
EO I
RE
S
GITERED
A
No. 17029
PROFESSIONAL
S EN
NEER
GI
.
A
J
M
ES JR
A. ,
ANDREWS
F 4
F
CCTV ML RENOVATION
M
CCTV
F
& ADDITION
TO NORTH
S H
CCTV
F
FAA
MACON
F S
FACP
2
PARK
DC DC
M
S
RECREATION
S
CENTER
CCTV
C
C
TV
F F
TYPICAL
ML 3
TYPICAL
BIBB COUNTY
CCTV
RECREATION
DEPARTMENT
REVISIONS
# DATE DESCRIPTION
Date: 05/16/2016
ON DOCUM ENTS
Sheet Name:
Electrical Low
Voltage Demolition
Floor Plan
CONSTRUCTI
Sheet Number:
ED301
A A A A A
J OC J OC J
B-4
MP ROOM
A A AX A
119
A
SS
J SOC
B
STORAGE F
120
X1 BX F F
AA
S
J
F
F
SHOWERS F OC
G
122 F
G
AA G G
OC G SHOWERS M
X1
124
(EX) OC
F F F
S
TLT F
121
J B 2
S
STORAGE
F
TLT M
129 123
G
X1 F X1
S
OC
AA F K
J F
F
S
F A G
JAN.
J
118 B-18
S
CONSULTING
D D VEST.
BX
J
DX 125 ENGINEERS
B-20
C C
ANDREWS, HAMMOCK
S
1 (TYP)
(TYP) 1 X1
S3
S3
S3S3 8
Suite 100
AA AA 4
OFC.
117
Macon, Georgia 31210
E
AK
OC Phone: (478)405-8301
OC
126
AA Fax: (478)405-8210
C H WWW.AHPENGR.COM
C
C AA
7 KILNS
C OC
115 J
STORAGE
GATHERING AREA
RG
EO
J 113
AA
OC
AA
105
I S
GITERED
RE
A
OFC. E
116 MP ROOM
112
AA AA
H
S3
S3
5 No. 17029
EP PROFESSIONAL
5 S S
J
8
EN
NEER
GI
.
A
NOTES:
J
M
C (THIS SHEET ONLY) ES JR
C A. ,
ANDREWS
C
AA AA AA 1 GENERAL: ALL EMERGENCY EGRESS LIGHT FIXTURES AND EXIT SIGNS SHALL BE
J
UNSWITCHED. RECONNECT TO EXISTING EMERGENCY LIGHTING CIRCUIT NEARBY
UTILITIZING #12, #12G.
GYMNASIUM EQUIP. 5 J
CRAFT OC
127
OC 128 5 E 114
J
2 CONTRACTOR SHALL UTILIZE #12, #12G;12"C AND MAKE CONNECTION TO EXISTING 120V
AA
4 UNSWITCHED LIGHTING CIRCUIT.
3
AA AA AA
RENOVATION
S
3 DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR (WATTSTOPPER #DT-205).
SSSS
D D DX 2
S3S3 4 LIGHT FIXTURE IS SWITCHED AND BATTERY PACK SHALL BE UNSWITCHED.
S
B BX B
5
VEST.
5 GENERAL: CONTRACTOR SHALL UTILIZE #12, #12G;12"C AND MAKE CONNECTION TO
& ADDITION
B BX X1 111 EXISTING 120V LIGHTING CIRCUIT.
K
AA
J
AA
B B
J J
S3 J
F 6 PROVIDE DUAL SWITCHING FOR STEP DIMMING OF LIGHT FIXTURES.
TO NORTH
RECEPT.
7 EXISTING LIGHT FIXTURES/CIRCUITS IN THIS SPACE SHALL REMAIN AS IS UNDER BASE
OC
104
S3S3 S3S3 S BID. ADD ALTERNATE #2 SHALL PROVIDE NEW LIGHT FIXTURES AS SHOWN.
S J J
5
8 EXISTING LIGHT FIXTURES/CIRCUITS IN THIS SPACE SHALL REMAIN AS IS UNDER BASE
BID. ADD ALTERNATE #6 SHALL PROVIDE NEW LIGHT FIXTURES AS SHOWN.
MACON
CORR.
AA AA AA
B B
101
BX
AX A AX A
OC
KITCHEN
PARK
J J 108
OC
S3
5
TROPHY CASE
103
J
A A MTG ROOM
106
A A
J
7
RECREATION
VEST.
OC
100
CENTER
S
BX FX F J J
SOC AA
AA
A A A A
1 STORAGE SOC ELEC.
J J 107 J
110
AA A
(TYP) 2
PANTRY (EX)
OC 109 A
8
K 7 8
BIBB COUNTY
X1
(EX)
RECREATION
JX
DEPARTMENT
25
JX
815 N MACON PARK DR
MACON, GA 31210
REVISIONS
Date: 05/16/2016
ON DOCUM ENTS
Sheet Name:
Electrical New Work
Lighting Floor Plan
CONSTRUCTI
Sheet Number:
E101
TV C
@ 90"
B-16
1
B-12,14
14.
HP-1 WP
MP ROOM B-8,10 10.
GFI 119
WP
2 GFI
B-1
B
1
STORAGE 1
120
EF-2 EF-1
FCU-1
BPIU-1
1
SHOWERS F
122
SHOWERS M
124
TLT F
121
B-6
STORAGE TLT M
129 123
GFI
GFI
JAN.
118
EF-3
1 CONSULTING
VEST.
125 ENGINEERS
ANDREWS, HAMMOCK
S
& POWELL, INC.
250 Charter Lane
Suite 100
OFC.
117
4. Macon, Georgia 31210
2 Phone: (478)405-8301
AK
126
Fax: (478)405-8210
C-5
C
WWW.AHPENGR.COM
C
KILNS
C-2,4 115
STORAGE
GATHERING AREA
RG
EO
113
105
I S
GITERED
RE
A
OFC.
116 MP ROOM
112
No. 17029
EP PROFESSIONAL
EN
C-1,3 NEER
GI
.
A
J
M
ES JR
A. ,
ANDREWS
GYMNASIUM 3 EQUIP.
@ 90"
CRAFT
127 128 114
RENOVATION
3. TV
VEST.
& ADDITION
111
3
TO NORTH
RECEPT.
104
C MACON
CORR.
101
KITCHEN
PARK
108
TROPHY CASE
103
MTG ROOM
106
RECREATION
VEST.
100
CENTER
STORAGE ELEC.
107 110
A
PANTRY (EX)
109 A
BIBB COUNTY
RECREATION
DEPARTMENT
REVISIONS
PROVIDE A 60A/3P, 22 kAIC CIRCUIT BREAKER PROVIDE A 100A/3P, 22 kAIC CIRCUIT BREAKER
EP (EX) C A(EX) B
2 PROVIDE NEW PANEL PER PANEL SCHEDULE & SPECIFICATION 262416.
600A
MAIN
F
EX
SEIMENS SERIES 'A' 200A, M.L.O., 600A M.L.O., 3PH, 4W, 208/120V
208/120V, 3PH, 4W PANEL, EXISTING SQUARE D "NQOB" PANEL EXISTING
Date: 05/16/2016
ON DOCUM ENTS
Sheet Name:
Electrical New Work
Power Floor Plan
CONSTRUCTI
Sheet Number:
E201
1
TV C
TV
C
C
WP
CCTV
S S
FA
FA
MP ROOM
119
F
F
STORAGE
120 S
FA
S FA
SHOWERS F
EX. 122
FA
FA
F SHOWERS M
FA
F 124
FA
TLT F 1
121
S
STORAGE TLT M
C
129
C
123 CCTV
T
FA
V
WP
FA
JAN.
FA
S
118
EX
S
FA
S
FA
S F ML
CONSULTING
VEST.
F
FA
125 ENGINEERS
FA
FA
S
S S
ANDREWS, HAMMOCK
S
FAP
2
& POWELL, INC.
CCMS
FA
250 Charter Lane
FA
CCTV
DISPLAY
Suite 100
FA
OFC.
117
Macon, Georgia 31210
FA
R
WP Phone: (478)405-8301
S AK
126
Fax: (478)405-8210
EX. 3
FA
S WWW.AHPENGR.COM
FA
EX
C
FA
S KILNS
S
115
STORAGE EX
GATHERING AREA
RG
EO
113
S
FA
S
FA
S
105
S I S
GITERED
RE
A
OFC.
FA
116 MP ROOM
112
No. 17029
2
FA
PROFESSIONAL
EN
NEER
GI
.
A
J
M
ES JR
S A. ,
ANDREWS
FA
S
GYMNASIUM EQUIP.
FA
CRAFT
127 128 114
S S
EX
RENOVATION
FA
TV
F EX
& ADDITION
FA
F
FA
FA F VEST.
111
C S S FA
S
FA
S
FA
S
FA
TO NORTH
RECEPT.
104
S
MACON
FA
CORR.
101
EX
PARK
FA
H
KITCHEN
108
FA
FA
WP
RECREATION
FA
S TROPHY CASE EX
F
103
F S MTG ROOM S
EX. 106
VEST.
S
100
FA
EX
FACP
SEC
CENTER
CCTV
STORAGE ELEC.
S
107 110
PANTRY TBB
109
FA FA CATV
S S S
FA FA
F F
BIBB COUNTY
EX.
RECREATION
DEPARTMENT
REVISIONS
2 PROVIDE DUCT MOUNTED SMOKE DECTOR PER SPECIFICATION 283110. DUCT SMOKE DETECTOR SHALL
BE INSTALLED IN EXISTING DUCTWORK BY MECHANICAL AND WIRED BY ELECTRICAL.
3 PROVIDE A "FIRE ALARM SHUTDOWN RELAY" AS PART OF THE FIRE ALARM SYSTEM.
5 EX = EXISTING
Date: 05/16/2016
ON DOCUM ENTS
Sheet Name:
Electrical New Work
Low Voltage Floor
Plan
CONSTRUCTI
Sheet Number:
E301
3 POLE CIRCUIT BREAKER IN PANEL TO BE PROTECTED. BREAKER SHALL BE 60A/3P,
3 PHASE WYE,
UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PROVIDE BREAKER
4 WIRE SYSTEM W/ GROUND
REGARDLESS IF INDICATED OR NOT IN PANEL SCHEDULE.
ALIGNER TYPE
LENGTH OF THE CONDUCTORS SHALL BE NO GREATER THAN 72 HANGER CONDUIT PENDANT CAST BOX W/THREADED
INCHES. CONDUCTORS SHALL BE 4#6 AND 1#10(G) IN 1"C. (MIN. 3 /4") MOUNTING POST
L1
A
L2
B
GASKETED COVER PLATE
L3
C
N
N
N LIGHTING FIXTURE
12 GUAGE
TYPE VARIES
CHANNEL
G
G
G
FINISHED FLOOR 212"
SURGE PROTECTION DEVICE
DEVICE SHALL BE INTERNALLY FUSED BY THE
MANUFACTURER FOR FAULT PROTECTION.
SEE SPEC FOR MODEL NUMBER.
PENDANT MOUNTED LIGHT FIXTURE DETAIL RGS CONDUIT
A
No. 17029
PROFESSIONAL
CEILING TILE EN
NEER
GI
.
A
J
M
ES JR
A. ,
ANDREWS
TO PANEL TO NEXT
ROOM
EXTEND PANEL @ BOTH
ENDS 1" TO NORTH
SMR SURFACE BOX
H A/B H A/B
3"
MACON
SWITCHING SWITCHING
OC N
G
TO LIGHT
FIXTURES
OC N
G
TO LIGHT
FIXTURES PARK
MOUNT PULL STATION HANDLE
RECREATION
NOTIFICATION DEVICES AT WALL
80" ABOVE FLOOR TO CENTER
OF DEVICE.
TYPICAL CENTER
G HT
PANEL FRONT PANEL
SERVICE
DISCONNECT/
MAIN PANEL
815 N MACON PARK DR
SIZE NEUTRALS 3 " THREADED
TO MATCH PHASE
8
ROD TO STRUCTURE MACON, GA 31210
NEUTRAL BUS
SURFACE MOUNTED PANEL WATER SHIELD DETAIL
SCALE: NONE
PIGTAIL AND SPLICE IF REQUIRED
BY STEEL ENCASEMENT. REVISIONS
[250.52A2]
REQUIRED GROUNDING ELECTRODE: MBJ [250.24A1]
BUILDING STEEL, EITHER BARE OR # DATE DESCRIPTION
CONCRETE ENCASEMENT WITH DIRECT
EARTH CONTACT, GREATER THAN CEILING TILE CEILING TILE
20'-0" DEEP.
GROUNDING BUS WALL
TO STREET
WATER
GEC EGC-MINIMUM #6 CU-3/4" MDF GROUND BUS
METER
NEUTRAL BUS
GEC-#6 CU SUB-PANEL
[250.66A] METAL STRUCTURE 3
WITHIN BUILDING. 8" THREADED
OF BUILDINGS
[250.52A1] ROD TO STRUCTURE
[250.104C] SIZE NEUTRALS TO MATCH PHASE.
REQUIRED GROUNDING ELECTRODE: TOP OF DOOR FRAME
EGC FROM SERVICE NEUTRAL
UNDERGROUND METALLIC DOMESTIC WATER TO BUILDING
LINE OUTSIDE BUILDING. (OMIT IF LESS THAN
10'-0" LONG, OR IF PLASTIC. [250.52A3] SIZE AS GEC
DO NOT BOND NEUTRAL BUS.
REQUIRED GROUNDING ELECTRODE: FIELD VERIFY THAT NEUTRAL
CONCRETE SLAB WITH ENCASED STEEL, IS ISOLATED FROM ENCLOSURE.
GREATER THAN 20'-0" IN DIRECT SIDE VIEW SIDE VIEW
EARTH CONTACT. GAS PIPING: BOND ONLY EGC
IF LIKELY TO BECOME
EGC [250.92] EGC
ENERGIZED BY FAULTED
CONDUCTOR [250.104B] CEILING TILE
EGC
CORRIDOR WALL WALL
GROUNDING BUS
GEC- #4 CU INTERIOR COLD
[250.66B] WATER PIPE.
[250.104A]
RIGID CONDUIT
EGC 112" X 112" PAINT TO MATCH WALL.
112" X 112"
12 GA CHANNEL
12 GA CHANNEL
GEC-#1/0 CU MOUNTED TO
[250.66] CORRIDOR WALL
Date: 05/16/2016
ON DOCUM ENTS
3 " THREADED ROD 3 " THREADED ROD
8 8 Sheet Name:
ELECTRICAL GROUNDING
SYSTEM TO EARTH
BONDING OF METALIC PARTS
TO MAIN BONDING JUMPER.
Electrical Details
TOP VIEW TOP VIEW
TOP OF DOOR FRAME
CONSTRUCTI
Sheet Number:
SCALE: NONE
METHOD A METHOD B
EXIT SIGN MOUNTING DETAIL EXIT SIGN MOUNTING DETAIL PENDANT MOUNTED EXIT SIGN MOUNTING DETAIL
SCALE: NONE SCALE: NONE SCALE: NONE
E701
ELECTRICAL LEGEND
LIGHTING FIXTURES - SEE LIGHTING FIXTURE SCHEDULE
RECESSED GRID FLUORESCENT
WALL BRACKET
FLOODLIGHT
AREA LIGHT
TRACK LIGHTING
CONVENIENCE OUTLETS
SIMPLEX
SWITCHES
A
SK SINGLE POLE, KEY OPERATED No. 17029
PROFESSIONAL
S3 THREE WAY, KEY OPERATED
K
OC OCCUPANCY SENSOR EN
NEER
GI
.
A
J
M
ES JR
,
SOC SINGLE POLE, OCCUPANCY SENSOR A.
ANDREWS
S2 DOUBLE POLE
S3 THREE WAY
S4 FOUR WAY
PANELS RENOVATION
120/208V, 3PH, 4W OR 240V, 1PH, 3W
CIRCUITS
MACON
RACEWAY IN CEILING OR WALL
SURFACE WIREWAY
GENERAL EQUIPMENT
COMBINATION STARTER/DISCONNECT
RECREATION
C CONTACTOR DEPARTMENT
PC PHOTO-CELL
R AUXILIARY RELAY
PUSHBUTTON
815 N MACON PARK DR
MOTOR - FRACTIONAL H.P.
MACON, GA 31210
5 MOTOR - HORSEPOWER NOTED
TRANSFORMER (DRY-TYPE)
T THERMOSTAT
REVISIONS
PULL BOX
# DATE DESCRIPTION
CABLE TRAY
TC TIME CONTROL
H HEAT DETECTOR
T T
T T INDICATING STROBE, WALL, CEILING
D DOOR HOLDER
S HIGH POWER SPEAKER- ADEMCO WAVE2- 2 TONE INTERIOR SPEAKER, ADEMCO 784LC- EXTERIOR SPEAKER- TAMPER RESISTANT
CCTV CCTV CLOSED CIRCUIT TV CAMERA- INTERIOR- MINIDOME, 720P- HONEYWELL H3D1F1/ EXTERIOR CAMERA- MINIDOME WITH IR, 720P- HONEYWELL H4D1FR1 WITH HONEYWELL HD4CHIP- WK WALL MOUNT KIT Drawn By: AJS
ON DOCUM ENTS
DS SECURITY DOOR SWITCH
Sheet Name:
CONSTRUCTI
Sheet Number:
E801