Exp 6
Exp 6
Apparatus Required:
S.No. Apparatus Range Type Quantity
Circuit Diagram:
Theory:
The internal load characteristics of DC shunt generator is plotted between V and IL. In this we
consider only drop due to armature reaction only. Drop due to ohmic losses are not considered in
the internal characteristics.
Basically the internal characteristics of DC shunt generator can be easily obtained by computing
these equations.
Eg = V + Ia Ra (Volts)
Ia = IL + If (Amps)
Eg : Generated emf in Volts
V : Terminal Voltage in Volts
Ia : Armature Current in Amps
IL : Line Current in Amps
Observation Table:
Result:
Thus load characteristics of DC shunt generator is determined.
Precautions:
1. The field rheostat of motor should be at minimum position.
2. The field rheostat of generator should be at maximum position.
3. No load should be connected to generator at the time of starting and stopping
Experiment No.
Apparatus Required:
S.No. Apparatus Range Type Quantity
Circuit Diagram:
Theory:
The external load characteristics of DC shunt generator is plotted between V and IL. In this we
consider the drop due to armature reaction and drop due to ohmic losses both the drops are
considered in the external characteristics.
Basically the external characteristics of DC shunt generator can be easily obtained by computing
these equations:
Eg = V + Ia Ra (Volts)
Ia = IL + If (Amps)
Eg : Generated emf in Volts
Observation Table:
Precautions:
1. The field rheostat of motor should be at minimum position.
2. The field rheostat of generator should be at maximum position.
3. No load should be connected to generator at the time of starting and stopping