You are on page 1of 1

M/s Miranda/Chief Engineer

G S odby
3.2.2024
hipping
Sid nr 1

Auxiliaries cooled from LT-cooler

 Stop pre-heatingpump for ME, (locally D 3, Stb side in engineroom).

 Close HT- valves to ME, 024 and 025, (D 4, Stb side in engineroom).

 Close 2 + 2 small de-airating? valves on aft side of both T/C.

 Close valve 062, connection to expansion tank, beside HT-regulating valve for ME.

 Stop LT pump for ECR daikin.

 Close both LT-valves, 030 and 031, to LT-cooler.

 Open both valves from AE on LT-cooler, 045 and 046.

 Close on HT-cooler both valves from AE, 043 and 044.

 Close HT-valves to HT-cooler, 020 and 021.

 Drain HT-water side to coolingwatertank if You are going to clean cooler.

 Follow AE-coolingwater temperature and waterlevel in expansiontank.