GATE VALVES
TEC
GATE VALVES
GATE VALVES Suitable for domestic
water services, heating, air-
conditioning plants.
155 SIZE
1/4" (DN 8)
PRESSURE
10bar/145psi
CODE
1550014
PACKING
20/140
SIZE
045
code
VOLA045
Materials
1
2
4
5
1 Nut 1 Steel
2 Handwheel 1 Steel
5 Washer 1 EPDM
7 Washer 1 Fiber
E
B
F F
A
DN 8 10 15 20 25 32 40 50 65 80 100
A 33 33 36 39 43 48 52 57 65 75 84
B 25 25 27 34 42 52 59 74 91 104 137
E 11 13 13,5 15,5 19 27 33 45 60 72 93
F 8 8 9 9 10 10 11 12 13 14 16
Kg/cm2 bar 10 10 10 10 10 10 10 10 16 16 16
LBS - psi 145 145 145 145 145 145 145 145 232 232 232
Certifications
ART. 155
157 SIZE PRESSURE CODE PACKING SIZE code
Materials
1
2
4
5
1 Nut 1 Steel
2 Handwheel 1 Steel
5 Washer 1 EPDM
7 Washer 1 Fiber
E
B
F F
A
DN 15 20 25 32 40 50 65 80 100
A 46 46 52 58 59 67 73 84 98
B 30 36 44 54 62 76 93 107 140
E 15 19 24 32 37 47 60 72 93
F 10 11 13 14 14 16 17 19 22
Kg/cm2 bar 20 20 20 20 20 20 20 20 20
LBS - psi 290 290 290 290 290 290 290 290 290
Certifications
ART. 157
160 SIZE PRESSURE CODE PACKING SIZE code
Materials
1
2
4
5
1 Nut 1 Steel
2 Handwheel 1 Steel
5 Washer 1 EPDM
7 Washer 1 Fiber
E
B
F F
A
DN 10 15 20 25 32 40 50 65 80 100
A 38 38 45 48 51 57 61 76 80 96
B 25 25 36 43 54 62 76 95 112 140
E 13 15 19 24 32 37 47 60 72 93
F 9 9 9 11 11 13 13 16 16 19
Kg/cm2 bar 16 16 16 16 16 16 16 16 16 16
LBS - psi 232 232 232 232 232 232 232 232 232 232
Certifications
ART. 160
FLOW RATE With water
AND PRESSURE
DROP CHART Art: 155 from 1/4” to 2”
1/4
1/2
bar
”
”
1/2
3/4
1”
1”
1”
2”
1
Pressure drop
0,1
0,01 m3/h
1 10 100 1000
Flow rate
GATE VALVES
TEC
FLOW RATE With water
AND PRESSURE
DROP CHART Art: 155 from 2”1/2 to 4” - 157 - 160
1/4
1/2
1/2
bar
”
”
3/8
1/2
3/4
1”
1”
1”
2”
2”
3”
4”
1
Pressure drop
0,1
0,01
1 10
Flow rate
100 1000
m3/h
GATE VALVES
Manifacturer Installation
instructions It can be installed in a vertical or horizontal position, it has a narrow gauge, it avoids the water hammer since it
closes in a slowly and proportional way. moreover, even if not properly, it can be used as a valve for water delivery
regulation. The bronze gate valves, since bronze is a more elastic material, they are suggested particularly for
the central heating plants or for the underground aqueducte connections. The brass gate valves, suitable to all
hydraulic uses, are widely employed in the irrigation plants. It is also important to pay attention to the fact that
many brass and bronze gate valves, mostly in the smaller sizes, are often damaged in their installation by forcing
thoroughly the screw of the pipe; as a result of this, the tapered seats are deformed and the tightness of the
wedge is endangered.
GATE VALVES
TEC
notes
GATE VALVES
We reserve the right to make improvements and changes to the products described herein and
to the relative technical data, at any time and without forewarning.
ITAP S.p.A.