Professional Documents
Culture Documents
Performer Cuspidor: Installation Instructions
Performer Cuspidor: Installation Instructions
Performer® Cuspidor
(For Performer III Chair & International Performer I Chair)
• Adjustable wrench or 9/16" open-end wrench If a Performer chair is not already installed, install it
now. Refer to the instructions that came with the chair.
• Magnetic leveling device Do not install the chair upholstery until all installations are
• 3/16" hex key complete.
• Torque wrench (preferred)
NOTE: If a Performer delivery system is being installed,
install it according to its instructions, before
About This Install adding the cuspidor to the chair.
Base up
Preparing the plumbing
If the air and water manual shutoff valves have not already
been installed, do so now. Refer to the floor box installa-
tion instruction, A-dec Publication No. 85.2802.00.
Performer I
Touchpad
Base up
Footswitch
Base up
Performer III
3. Loosely install a washer, a split washer, and a hex nut Installing the cuspidor
onto each end of the U-bolt (see Installing cuspidor to • Install the cuspidor onto the cuspidor post.
Performer I chair).
• Install the cup fill spout (long) and the bowl
4. Insert the cuspidor post through the U-bolts and rinse spout (short) on the cuspidor.
begin tightening the hex nuts until snug.
Ground
wire
Cup Bowl
fill rinse
spout spout
Leveling
device
U-bolts
Cuspidor
post
O-rings
Split
Washer washer
Hex nut
2. With the chair in the down position, disconnect the 2. Tighten both nuts on each U-bolt snugly. (Tighten
back-down spring on the appropriate side. Install the one of the nuts on each U-bolt to 25 ft lb [34 N·m]
3/8" adjusting screw. maximum or an additional 1/2 turn clockwise).
3. Insert the cuspidor post through the U-bolts and 3. Check the leveling of the post.
begin tightening the hex nuts until snug.
4. Reattach the back-down spring.
6. Install the cup fill spout (long) and the bowl rinse
spout (short) on the cuspidor.
Ground
screw
Cup Bowl
fill rinse
spout spout Ring
terminal
Leveling
Hex nut device
Split
washer
Washer
Chair
structure
Cuspidor
post Adjusting
U-bolts screw
0 7
0 100
10 90
1 6
80
20
30 70
2 40 60 5
50
3 4
Functional earth (ground). Mode of CONTINUOUS OPERATION: All models except dental
chairs
operation
Attention, consult accompanying documents. No user service- CONTINUOUS OPERATION WITH INTERMITTENT LOAD-
able parts. Attention, line voltage. Only licensed electrician ING: Dental chairs - 5% duty cycle
should remove cover.
Caution: Metal surfaces can be hot during and following the Environmental Specifications
dry cycle.
TEMPERATURE/ SPECIFICATION
HUMIDITY
Electrical Rating
Storage/ Temperature: -40C to 70˘C
TYPE SPECIFICATION (-40˘F to 158˘F)
Transportation
Relative humidity: 80% for up to 31˘C,
Volts: 100/110-120/220-240 VAC decreasing linearly to
50% at 40˘C.
Frequency: 50-60 Hz
Current: As configured and specified in equipment manual Operating Temperature: 10˘C to 40˘C
(products labeled 15A or greater require dedicated (40˘F to 104˘F)
circuit, identified in distribution panel).
Relative humidity: 80% for up to 31˘C,
decreasing linearly to
50% at 40˘C.