HARMONY - MOROBE CONSOLIDATED UNIT INFORMATION COMPONENT INFORMATION SHOP JOB/SEGMENT

GOLDFIELDS LTD M/M : CATERPILLAR 6030 Make :CATERPILLAR W1690038


Mobile equipment
EX801 ENGINE DIESEL LEFT S/N : DHL30291 Model :C-27
LOC : MOBILE EQUIP S/N :
Condition Monitoring Centre Express Post Satchels can be recycled. Please return any unused satchels.

C CORRECTIVE ACTION IS REQUIRED DATE 14/01/2024 LCN 19827624


Sample contains a slight water contamination. V100 test invalid as a result. Viscosity acceptable @ 40C for oil grade indicated. Soot is high. Iron
is high, All other completed test results appear acceptable. Suggested Action: Investigate and evaluate compartment condition. Inspect the used
oil filters for abnormal debris. Check for causes of elevated sooting i.e. low boost pressure, high fuel burn, clogged air filters, duty cycle, EGR
system etc. Water may be caused by condensation. Resample 100 hours following assessment. Sample Notes: Sample Taken By: PM Service
Crew Normal - Interval: 2000
CURRENT SAMPLE TOOK 19 DAYS TO REACH LAB INTERPRETED BY Richard Hamm Ph 3365 9341 ANALYSED BY sianf MAINTENANCE

B CORRECTIVE ACTION MAY BE REQUIRED DATE 11/11/2023 LCN 19580321


Sample is contaminated with water. V100 Viscosity test invalid as a result. Viscosity acceptable @ 40C for oil grade indicated.Soot is
increasing.Iron is slightly high,All other completed test results appear acceptable. Suggested Action:Levels may be acceptable due to the run-in
period.Check for causes of elevated sooting and evaluate.Inspect the used oil filters for abnormal debris.As a precaution inspect for leaks at seals,
covers, fill points & breathers that may allow water to enter.Continue sampling at the recommended interval now that the oil has been changed.
Sample Notes: Sample Taken By: PM Service Crew Normal - Interval: 500
PREVIOUS SAMPLE TOOK 18 DAYS TO REACH LAB INTERPRETED BY Calvin Wang ANALYSED BY samlines MAINTENANCE

IDENT SAMPLE INFORMATION ELEMENTAL ANALYSIS FTIR ANALYSIS MISC


SAMPLE LAB OIL Cu Fe Cr Pb Al Si Sn Ni Mn V Ti Ag Sb S UST UOXI UNIT USUL AN TAN TBN COL RULER MPC
SMU E CMU FMU C LCN
DATE DATE ADD Copper Iron Chromium Lead Aluminium Silicon Tin Nickel ManganeseVanadium Titanium Silver Antimony Sulfur Soot Oxidation Nitration Sulfation Acid # Total Acid # Base # Colour Life
Membrane
% Patch Colourimetry

37436 C 2,934 Y 14/Jan/24 02/Feb/24 19827624 4 75 1 <1 1 3 <1 <1 <1 <1 <1 <1 <1 2780 100 12 1 23

37436 B 2,934 351 Y 11/Nov/23 29/Nov/23 19580321 3 49 <1 <1 <1 3 <1 <1 <1 <1 <1 <1 <1 72 11 <1 20

37187 A 2,685 720 N 15/Oct/23 02/Nov/23 19462019 <1 23 <1 <1 <1 3 <1 <1 <1 <1 <1 <1 <1 3390 27 10 <1 16

37085 C 2,583 618 Y 04/Oct/23 02/Nov/23 19463806 7 85 <1 <1 <1 3 2 1 <1 <1 <1 <1 <1 3562 61 12 <1 19

36708 C 2,206 241 N 17/Jul/23 11/Aug/23 19107011 13 133 1 1 <1 3 1 <1 <1 <1 <1 <1 <1 88 12 9 22

36467 C 1,965 576 Y 13/Jun/23 12/Jul/23 18965502 60 189 2 1 <1 4 1 <1 1 <1 <1 <1 <1 2162 111

IDENT FLUID CHARACTERISTICS PHYSICAL TESTING PARTICLE ANALYSIS


OIL Ca Mg Zn P Mo B Ba Cd V40 V100 F Na K WAT WKF OH Li PQ DEP GLYC PC4 PC6 PC14 PC38 PC50 ISO ISO4407
SMU E OIL BRAND
GRADE Calcium Magnesium Zinc Phosphorus
Molybdenum Boron Barium Cadmium Vis. 40C Vis. 100C Fuel % Sodium Potassium Water Water PPM Hydroxyl Lithium PQ Index Deposits Glycol >4 µm >6 µm >14 µm >38 µm >50 µm ISO 4406 ISO 4407

37436 C PUMA HD PLUS CI-4 15W40 3459 15 1001 803 36 28 <1 <1 94 <2.0 <1 <1 0.2 <1 6 N--B

37436 B PUMA HD PLUS CI-4 15W40 3402 15 952 793 34 35 <1 <1 94 <2.0 1 <1 0.2 <1 7 N--B

37187 A PUMA HD PLUS CI-4 15W40 3341 15 930 808 33 51 <1 <1 89 12.7 <2.0 <1 <1 0.1 <1 5 N--B

37085 C PUMA HD PLUS CI-4 15W40 2985 13 856 721 31 35 <1 <1 82 12.0 2.7 1 <1 0.1 <1 7 LNFB

36708 C PUMA HD PLUS CI-4 15W40 3380 13 920 748 33 28 <1 <1 93 <2.0 1 <1 0.2 <1 8 N--B

36467 C PUMA HD PLUS CI-4 15W40 3108 12 836 706 30 25 <1 <1 99 <2.0 2 <1 0.2 1 6 N--B