You are on page 1of 1

BASIC CALCULATION FOR SACRIFICIAL SYSTEM

DESIGN DATA
CALCULATED LIFE TIME OF ANODE (Y) = 25 Years
CURRENT DENSITY IN SEAWATER (CDSW) = 35 mA/sq.m
CURRENT DENSITY IN SEABED (CDSB) = 15 mA/sq.m
CONSUMPTION RATE OF ALUMUNIUM WATER FACE (CON) = 3.5 Kg/Amp.Y
ANODE UTILIZATION FACTOR (U) = 0.9
SAFETY FACTOR (SF) = 1

INFORMATION FROM FIELD


LSW = Length of pile in seawater
LSB = Length of pile in seabed
SASW = Surface area of pile in seawater = pi x Dia x LSW
SASB = Surface area of pile in seabed = pi x Dia x LSB
CSW = Protective current required in seawater = pi x Dia x LSW x CDSW
CSB = Protective current required in seabed = pi x Dia x LSB x CDSB
CP = Protective current required in pile = CSW + CSB
WT = Total Weight of almunium anode req. = CP x Y x CON x SF : U
W = Propose Anode weight / pile
NOS = Number of Pile
N = Number of Anode
AL = Alumunium Supplied = W x NOS

STRUCTURE DIA LSW LSB SASW SASB CSW CSB CP WT W NOS N AL


No.
AREA m (m) (m) (m2) (Amp) (Amp) (Amp) (Amp) (Kg) (Kg) (Pcs) (Pcs) (Kg)
1 Jetty 5 Area 0.8 15 40 37.68 100.48 1318.8 1507.2 2826 274.75 275 84 84 23,100
2 Jetty 6 Area 0.8 15 40 37.68 100.48 1318.8 1507.2 2826 274.75 275 32 32 8,800