Units Remarks S.No Vehicle MSW(MT) Vehicle trips (MT) 1 TATA Ace 1.6 11 5 88 MT 2 Tractor Trolley 2.5 7 5 87.5 MT 3 Compactor 3.2 3 5 48 MT 4 Dumper 5 1 5 25 MT Total MSW supply/Day 248.5 TPD No.of Hour 24 Hrs Tota MSW Supply/Day 10.35416667 TPH PLANT CAPSITY & GENERATION CALCULATION BASED ON MSW COLLECTION S.No Item Description Cal. Value Units Heat Energy calculated based Generated MSW Dulong's 1 HV(KJ/Kg) = 338.2*C+144.8*(H-O/8)+94.2*S) Formula 12304.392 KJ/Kg Persentages by Mass theoretical values based on Literature C = 31.22 H=8.17 O=55.68 S = negotiable 1.A review consideration 1.B Consideration of 70% Calculated Heat Energy Generated to get Steam Energy 8613.0744 KJ/Kg 2 Available Steam Energy 8613.0744 KJ/Kg 3 Heat Energy required to produce One Unit(KWH) - Theoritical 1KW = 3600 KJ/h 3.A Heat Energy required to produce One Unit(KWH) - Practical Consideration 31.6% ofTheoritical value 11392.405063 KJ/KWH Electrical Energy Generation KWH/KG = Steam Energy(KJ/kg)/Heat energy required to produce 1KWH in practical 4 consideration 0.7560365307 KWH/KG 5 Total MSW waste for utilization in Kg's per day 400000 Kg/day 6 Total Gross Electrical Energy to be Generated 302414.61 KWH/day 7 Station Auxillaries allowance- 6% of Gross Energy produced 18144.88 KWH/day 8 Unaccounted Heat Energy loss = 5% of Gross Energy produced 1512.0730613 KWH/day 9 Net Electrical Energy to be Generated in KWH/Day 282757.66 KWH/day 10 Net Electrical Energy to be Generated in MWH/Day 282.75766247 MWH/day 11 No.of Hours Considered in A day 24 HRS 12 Net Power Generation in MW 11.78156927 MW 14 Gross Power Generation By adding Satation Auxillary 12.600608844 MW 15 Net Monthly Energy Generated 8.4827298741 MU