TOFD & PHASED ARRAY – QUESTIONNAIRE

1. TOFD is suitable for:


a. Flaw Sizing and Flaw Detection
b. For Flaw Detection
c. Not for Flaw Detection
d. Partially for Flaw Detection

2. TOFD is an economical technique.


a. Yes
b. No

3. TOFD was invented approximately in Year


a. 1975
b. 1980
c. 1985
d. 1990

4. TOFD has shown a higher Probability of Detection (POD) than other NDT
Methods?
a. Yes
b. No
5. The TOFD principle is based on evaluation of the
a. Diffraction Signals at Crack Edges
b. Amplitude of the echo height
c. Sound attenuation
d. Frequency

6. How many Probes TOFD uses?


a. 4
b. 3
c. 2
d. 1

7. In what direction to the weld the scan is performed for initial flaw
detection?
a. transverse and longitudinal
b. transverse
c. longitudinal

1
nd
No.2, II Floor, Govindaraji Naickar Complex, Janaki Nagar, Arcot Road, Valasaravakkam, Chennai 600087. Tamilnadu. India.
SOUTHERN INSPECTION SERVICES
E-Mail: sisins@gmail.com,
Website: www.sisndt.com, www.ndtsis.com, www.pdmsis.com
: 91-44-24868785, 24864332, 91-44-2647537

8. Probes used for TOFD must deliver the performance:


a. High Bandwidth
b. Narrow Bandwidth
c. Low Frequency
d. High Frequency
9. Diffracted Signals vs. Pulse Echo Signals are
a. higher
b. weaker
c. the same

10. In what area TOFD is uncertain?


a. In the wall center
b. Near surface
c. Far surface
d. Near and Far surface

11. The interpretation of TOFD images is


a. easy
b. very difficult
c. needs experience

12. TOFD shall be combined with


a. Radiography
b. Pulse Echo

13. TOFD can be applied for the same scope of materials as Pulse Echo
Technique
a. Yes
b. No

14. Can it happen that mode conversion causes virtually defects where
there are none?
a. Yes
b. No

15. Shall TOFD technique be used for Flaw Detection without combination
with other Methods?
a. Yes
b. No

16. A true crack size of 35 mm was measured by TOFD as


a. 10 mm
b. 30 mm
c. 5 mm
d. 40 mm

2
nd
No.2, II Floor, Govindaraji Naickar Complex, Janaki Nagar, Arcot Road, Valasaravakkam, Chennai 600087. Tamilnadu. India.
SOUTHERN INSPECTION SERVICES
E-Mail: sisins@gmail.com,
Website: www.sisndt.com, www.ndtsis.com, www.pdmsis.com
: 91-44-24868785, 24864332, 91-44-2647537

17. What is the ideal number of signals used to size a flaw using TOFD?
a. 2
b. 3
c. 4
d. 5

18. The TOFD image is similar to a


a. A-scan
b. B-scan
c. C-scan
d. P-scan

19. What kinds of probes are usually applied with TOFD?


a. longitudinal
b. transversal

20. Is there a Standard or Guideline for TOFD available?


a. No
b. Yes
c. only a Draft

21. Is it necessary to define a gain or an amplitude level when using TOFD?


a. Yes
b. No

22. What probes are suitable for a working range 10 mm to < 30 mm?
a. 2 to 5 MHz
b. 5 to 10 MHz
c. 10 to 15 MHz

23. Is one probe setup (2 probes at a fix distance) suitable?


a. Yes
b. No

24. What is the shortest near surface dead zone (in mm)?
a. 1
b. 2
c. 3
d. 6

25. What method can perform more exact sizing?


a. TOFD
b. Reflection method

3
nd
No.2, II Floor, Govindaraji Naickar Complex, Janaki Nagar, Arcot Road, Valasaravakkam, Chennai 600087. Tamilnadu. India.
SOUTHERN INSPECTION SERVICES
E-Mail: sisins@gmail.com,
Website: www.sisndt.com, www.ndtsis.com, www.pdmsis.com
: 91-44-24868785, 24864332, 91-44-2647537

26. Is it true that an ASME Code has accepted TOFD in lieu of radiography
examination for thicknesses over 4 inches?
a. Yes
b. No

27. TOFD use


a. Single probe
b. Dual probe
c. Two probes in pitch catch mode
d. all
e. None

28. TOFD can be performed by


a. Two probes in pitch catch method
b. Phased array probes
c. LW probes
d. all
e. none

29. TOFD use


a. LW configuration
b. Shear wave configuration
c. Lamp wave configuration
d. all
e. none

30. The probes used in TOFD are


a. Highly damped and high freq
b. Highly damped and of low frequency
c. Slightly damped and of high frequency
d. Slightly damped and low frequency

31. TOFD method uses


a. Very small beam divergence
b. Large beam divergence
c. Beam divergence large enough to produce lateral wave and back wall
reflection
d. Beam divergence small enough to produce high resolution

4
nd
No.2, II Floor, Govindaraji Naickar Complex, Janaki Nagar, Arcot Road, Valasaravakkam, Chennai 600087. Tamilnadu. India.
SOUTHERN INSPECTION SERVICES
E-Mail: sisins@gmail.com,
Website: www.sisndt.com, www.ndtsis.com, www.pdmsis.com
: 91-44-24868785, 24864332, 91-44-2647537

32. TOFD Uses


a. Tip diffracted wave
b. Lateral wave
c. Reflected wave and Back wall reflection
d. all
e. None

33. Petrochemical application uses


a. Raster TOFD
b. linear TOFD
c. Exponential TOFD
d. all
e. None
34. Power generation application uses
a. Raster TOFD
b. linear TOFD
c. Exponential TOFD
d. all
e. None

35. Raster TOFD


a. Collects more data
b. Faster
c. Less accurate
d. all
e. None

36. TOFD can


a. Only detect defects
b. Can only sizing defects
c. It uses B scan Grey scale
d. all
e. One

37. Choose correct statement


a. Linear scanning is the single axis scanning parallel to the weld
b. Raster scanning is an x-y back and forth scanning motion
c. Most of the weld caps in the power generation are removed to permit
raster scanning
d. all
e. None

5
nd
No.2, II Floor, Govindaraji Naickar Complex, Janaki Nagar, Arcot Road, Valasaravakkam, Chennai 600087. Tamilnadu. India.
SOUTHERN INSPECTION SERVICES
E-Mail: sisins@gmail.com,
Website: www.sisndt.com, www.ndtsis.com, www.pdmsis.com
: 91-44-24868785, 24864332, 91-44-2647537

38. In TOFD
a. Beam divergence is very small
b. The probes are typically centered over the weld central line
c. For very low thickness , double TOFD pairs are used
d. All
e. None

39. Upper and Lower tip echoes will have


a. Same phase
b. phase reversal
c. 90 degree phases difference
d. 360 degree phase difference

40. Maximum amplitude of diffracted signals are obtained at about


a. 20°
b. 45 °
c. 70 °
d. none

6
nd
No.2, II Floor, Govindaraji Naickar Complex, Janaki Nagar, Arcot Road, Valasaravakkam, Chennai 600087. Tamilnadu. India.
SOUTHERN INSPECTION SERVICES
E-Mail: sisins@gmail.com,
Website: www.sisndt.com, www.ndtsis.com, www.pdmsis.com
: 91-44-24868785, 24864332, 91-44-2647537

27c, 28D, 29a, 30a, 32D, 33B, 34a, 35a,36d, 37D, 38B, 39 B 40

Question Answer Question Answer


No. No.
1 D 27 C
2 A 28 D
3 A 29 A
4 A 30 A
5 A 31 C
6 C 32 D
7 A 33 B
8 A 34 A
9 B 35 A
10 B 36 D
11 C 37 D
12 B 38 B
13 B 39 B
14 A 40 C
15 B
16 C
17 C
18 B
19 A
20 B
21 A
22 B
23 B
24 B
25 A
26 A