You are on page 1of 3

FASNT – ULTRASONIC TESTING TEST

1. Which one of the following Probes has a longer dead zone?


a. 2Mhz, TR Probe
b. 2Mhz, Normal Probe
c. 4Mhz, TR Probe
d. 4Mhz, Normal Probe

2. What is the crystal angle of Single Mode Probe?


a. 0 degree b. 90 degree c. 180 degree d. None of these

3. What is the formula for Surface Distance?


a. T X CosØ
b. T X TanØ
c. T / CosØ
d. T / TanØ

4. The Thickness of the Welded Plate is 12 mm.


Which of the following probe is best suitable to do the testing?
a. 45 degree b. 60 degree C. 70 degree d. None of these

5. What is the full form of DAC?


a. Depth Amplitude Couplant b. Distance Amplitude Couplant
b. Distance Amplitude Curve d. Distance Angle Curve

6. The ability to detect the defects seperately which are located closely to each other is
called
a. Sensitivity b. Echo signal c. Penetration d. Resolution

7. The echo signal is at 80% of the Full Screen. If you reduce 12db from the Gain,
What is the exact percentage of the echo signal?
a. 20% b. 60% c. 40% d. 10%

8. The Range of the Sound Path is 100mm.


If the probe is facing towards 50mm radius, how many echoes will appear on the
screen? (INCLUDE INITIAL ECHO)

a. 2 b. 1 c. 3 d. None of theseh

ALL THE BEST


9. The thickness of the V1 block is 25mm. If you place the TR probe on it, What is the
Surface Distance of the First Back wall Echo?
a. 25 b. 50 c.100mm d. None of these

10. What is ASNT stands for?


a. American System of Non Destructive Testing
b. American Standard of Non Destructive Testing
c. American Society of Non Destructive Testing
d. American Signal of Non Destructive Testing

11. What is the tolerance for the Probe Angle?


a. +/- 1 degree
b. +/- 1 mm
c. +/- 2 degree
d. +/- 2 mm

12. Which standard will you refer for Non Destructive testing?
a. ASME SEC IV b. ASME SEC V c. ASME SEC VI d. ASNT SEC VI

13. What is the formula for Range ?


a. 1.25 X Full Surface Path
b. 1.25 X Full Sound Depth
c. 1.25 X Full Surface Distance
d. 1.25 X Full Sound Path

14. What is the dimension of the crystal in a 70 degree probe?


a. 8mm X 8mm
b. 7mm X 8mm
c. 8mm X 9mm
d. 9mm X 9mm

15. By Theory, The dual mode probe has


a. Long Dead Zone
b. No Initial echo
c. Low Dead
d. Long initial echo

ALL THE BEST