Professional Documents
Culture Documents
STANDARD SPECIFICATION
V.2.4.4
August 2023
Table Content:
Material:
Installation Method:
MATERIAL LIST
(BRAND AND SPECIFICATION)
ASIANET. <cable brand>. <fiber count>. <ITU-T Standard>. <cable type>. <year>
• Sample:
2. Subduct
Specification : For BB/Feeder:
• Diameter 40/34
• White Color With Blue Strip (RGB 0,102,255)
For Distribution:
• Diameter 33/27
• Diameter 32/28
• White Color With Blue Strip (RGB 0,102,255)
Brand : 1. Unilon
2. Vinilon
3. Jembo
4. Arkan
5. Alvapipe
Detail:
3. Joint Closure
Type : Burial JC (Inline)
Specification : Capacity 24, 48, 72, 96, 144Core
• Have IP68 verified
• Support for JC for 48, 96, 144, 288 Core
• Support minimum 4 cable inlet (2 ast & 2 west)
• Cable inlet support for size 10 - 20 mm
• Support Stopper rubber cable to inlet
• Support Seal water proofing JC
• Support Clamp cable Strength member
• Support Tube / Plastic setting Core FO
• Support Tray Tube Optic
• Support Tube Protector
• Support additional Asphalt seal waterproofing
Brand : 1. NWC
2. Corning
3. Litech
4. PAZ
5. Magnatech / Lightwave
6. Ficomm
Sample:
4. Poles
TOP POLE
OUTER DIAMETER (D1) : 89,1 MM 89,1 MM
THICKNESS : 3.0 MM 3.0 MM
LENGTH SECTION 1 : 3000 MM 3000 MM
BOTTOM POLE
OUTER DIAMETER (D1) : 114,3 MM 114,3 MM
THICKNESS : 3.0 MM 3.0 MM
LENGTH SECTION 1 : 4000 MM 6000 MM
TOP POLE
OUTER DIAMETER (D1) : 76,3 MM 76,3 MM
THICKNESS : 2.8 MM 2.8 MM
LENGTH SECTION 1 : 3000 MM 3000 MM
BOTTOM POLE
OUTER DIAMETER (D1) : 89.1 MM 89.1 MM
THICKNESS : 2.8 MM 2.8 M
LENGTH SECTION 1 : 4000 MM 6000 MM
Label OTB
Dust cap installation reminder
Sample:
Specification:
Brand 1. NWC
2. Corning
3. PAZ
4. LITECH
5. SGT
Sample:
Application:
Dimension 42U (for ODF with OLT sites)
Dimension 20U, 27U, and 32U (for site non-OLT)
Specification for OLT sites • Material = Sheet Metal
• Colour = Black, or Dark Grey
• Cable in/out line = 10 cable lines (maximum 13 cables)
• Subrack Capacity = 10 Pcs
• Basetray Capacity = 60 Pcs
• Already provide patching placement
• Various height, depth and width for different application can be provided
depends on Building Management requirement or Condition on site
Brand 1. Indorack
2. HAGANERACK
3. PAZ
4. SGT
Specification:
FAT – Indoor
Specification ▪ For Indoor usage, key or slam lock
▪ FAT should support passthrough cable without reassembly the FAT parts
▪ Minimum IP Rate: IP65
▪ Support minimum 2 feeder cable inlet with stopper
▪ Support minimum 16 drop cable inlet with stopper
▪ Support holder clamp for FO cable
▪ Support holder clamp for FO cable Strength Member
▪ Connector type SC/APC
▪ Support Tray adapter SC/APC to SC/APC up to 16 ports
▪ Support tray spare for FO Pigtail
▪ Support tube protector tray
▪ Support Wall mounted installation
Brand 1. NWC 4. Magnatech
2. Corning 5. SGT
3. PAZ 6. Ficomm
Sample
10. Splitter
Type 1:2, 1:4, 1:8, 1:16
Specification No Patch Connector
Sample
11. Patchcord
Patchcord (3M-50M)
13. Pedestal
Brand :
Brand/Material already check & get Approval by Asianet
Sample
INSTALLATION METHOD
FDT Passive
2. Marking Post
Mainhole 100x100x150 cm
Handhole 80x80x150 cm
Handhole 80x50x150 cm
Handhole 40x40x60 cm
4. Poles
Pole ID
• Installation of Slack Hanger per 250m, or if any equipment JC, FDT, etc.
• Distance between poles (default) 50 m, cable sling (sag/andongan) is allowed 1% of the cable
length between poles.
• Planting poles in 1 lane using 7 meter poles.
• Planting poles at crossing using 9 meter poles only for open areas.
• 9 meter pole is also used for gas stations, rest areas and truck/container parking areas
• For the installation of a 9 meter pole, it can be adjusted to the conditions of the area.
• Installation uses Suspension for straight route and default poles span.
• Installation uses Dead end for not straight route or joint pole 7m and 9m, and if any equipment in
the pole.
• In attaching the cable at the Dead End, it is mandatory to use the Ratchet Puller N.G.K model 2000,
manual method is not allowed (so that the sling (sag/andongan) does not go down too much).
5. Slack Hanger
Specification : • Size 90 cm x 90 cm
• Material Galvanize (hot dip)
• Installation using 2 steel band at the pole
6. Pole Accessories
Dead End
Specification : • Configuration at straight route are 1 Dead End every 2
Suspension
• If the route turns from 10° up to <45°, then mandatory should using
Dead End
• Material for bracket, clamp, horse shoe, using “cor babet”
• Wire Selling using stainless steel and rustproof
• Installation using 2 steel band
• Size of Dead End refer to cable size
Suspension
Specification : • Suspension used for straight route (or bend route below 10°)
• Using telescopic type
• Mandatory using ”spie”
• Inside material using rubber
• For the hook using galvanized rust proof material
• Installation using 2 steel band
Steel Band
Specification : • Made from non magnetic stainless steel
• Stoplink using galvanized rustproof material
• Size 0.7 mm x 20 mm
• Installation must use Band it Tool
Sling Wire
Specification : • Material Steal
• Size 6mm
• Use for Drop Wire cable
• Installation for Pole to Pole without cable
7. Warning Tape
8. Label Mainhole/Handhole
9. Label Cable
100mm
LOGO
Font Style : Aerial Bold
Font Size : 80 pt
Font Color : Blue
Material : Spray Paint or Foam
ID
Font Style : Aerial Bold
Font Size : 80 pt
Font Color : Black
Material : Spray Paint or Foam
Label Pedestal:
LOGO
Font Style : Aerial Bold
Font Size : 80 pt
Font Color : Blue
Material : Spray Paint or Foam
ID
Font Style : Aerial Bold
Font Size : 80 pt
Font Color : Black
Material : Spray Paint or Foam
KBKS_BBP08
DS_P0001
Labeling Rule:
11.12. Detail hanging pole IWF crossing river span 12 s/d 24 meter
11.15. Detail specific bridge construction crossing river span 12 s/d 24 meter
- END OF DOCUMENT -