[Meaning] In case DOX-100 PCB is not applied to CP, it detects a fault as checking [Countermeasures]
from mechanical switches to pit switch.
1. Verify that DIP SW2 of SPEC2 is off position.
2. Key in A21E on annunciator to check the data of address 8005
(Normal : 01).
[Explanation]
3. Key in A21E on annunciator to check the data of address 82C1
it detects a fault if any mechanical switch on hoistway and safety signal (Normal : 01).
is ‘OFF’ condition. If data is ’00’, check the E stop switch on OPB.
4. Check the voltage at each connector. (Be careful of 110V)
GRS(01~02), LSU(01~02, FLS), LSD(01~02,FLS),
Y1(01,11,12,02), HSAF(04,05,07), GRS(09)
It must be 110Vac ±10%
5. Replace DOC-140 PCB, DCL PCB.
Part: TCD Code
Solon Standard / Trouble Shooting Ctrl No.: Solon(S)-TS-03-0
Page: 49/120
○ Operation CPU
TCD 84 R5SY Relay ON trouble Detection Application Si250
○ Speed CPU
[Meaning] R5SY ON condition lasts for over 540ms after R5SC OFF command signal. [Countermeasures]
check_out
TMC_Start(R5SC_
ERROR_DETECT_T)
TMC_Check(R5SC_ERROR_
DETECT_T, FINISH_STATE) SWD_I[VI_R5SC]
TCD 84
0x8001
Part: TCD Code
Solon Standard / Trouble Shooting Ctrl No.: Solon(S)-TS-03-0
Page: 50/120
○ Operation CPU
TCD 85 R5SY Relay off trouble Detection Application Si250
○ Speed CPU
[Meaning] R5SY OFF condition lasts for over 540ms after R5SC ON command signal [Countermeasures]
1. 1. Verify the power supply for DOC-140 PCB.
Di-01 : 24Vdc
Di-11 : 24Vdc
[Explanation] PWR01: 5Vdc
check_out
TMC_Start(R5SC_
ERROR_DETECT_T)
TMC_Check(R5SC_ERROR_
DETECT_T, FINISH_STATE) SWD_I[VI_R5SC]
TCD 85
0x8001
Part: TCD Code
Solon Standard / Trouble Shooting Ctrl No.: Solon(S)-TS-03-0
Page: 51/120
○ Operation CPU
TCD 86 C1BR CTT. on trouble Detection Application Si250
○ Speed CPU
[Meaning] Even after 1200ms away from C1BR off command, C1BR on is [Countermeasures]
maintained.
P24
0x8080 0x9210
1. Check voltage of DI-03 of DOC-140 from above circuit.
0x8029 Coil[SW_SS_DSP_WD]
• When C1BR driving section is ON : DC 24 V
check_out
• When C1BR driving section is OFF : 0 V
TMC_Start(R5SC_
ERROR_DETECT_T) 2. Check the state of input state indicating row(row 3)
TMC_Check(C1BR_ERROR_ column 10 on LCD of DOA-100.
DETECT_T, FINISH_STATE) SWD_I[VI_C1BR]
TCD 86
• When C1BR driving section is ON : 1
0x8029 • When C1BR driving section is OFF : 0
3. Check BS1,BS2 switch by input buffer reading(A21E)
and Voltage measurement
• Even after 540ms away from OFF command of C1BR output, C1BR contact
does not turns OFF, and C1BR contact point input is ON is detected(driving
section ON failure).
• Even with C1BR contact off, C1BR contact point input on is detected, because
of contact point not being off(contact point melted and adhered).
Part: TCD Code
Solon Standard / Trouble Shooting Ctrl No.: Solon(S)-TS-03-0
Page: 52/120
○ Operation CPU
TCD 87 C1BR CTT. OFF trouble Detection Application Si250
○ Speed CPU
[Meaning] [Countermeasures]
Even after 540ms away from C1ST off command, C1ST on is maintained.
P24
• Even after 540ms away from OFF command of C1ST output, C1ST contact
does not become OFF, and C1ST contact point input is ON is detected.
• Even with C1ST contact off, C1ST contact point input on is detected, because
of contact point not being off.
Part: TCD Code
Solon Standard / Trouble Shooting Ctrl No.: Solon(S)-TS-03-0
Page: 54/120
○ Operation CPU
TCD 89 C1ST CTT. OFF trouble Detection Application Si250
○ Speed CPU
[Meaning] Even after 540ms away from C1ST on command, C1ST off is maintained. [Countermeasures]
P24
[Meaning] Even after 360ms away from driving OFF command from operation side [Countermeasures]
to speed side,ON feedback is maintained.
1. Check flickering condition of WDT LED(green) of DPC-130.
2. Check connection condition of communication cable(64P)
[Explanation] between operation and speed.
Coil[SV_INV_
Coil[RS_SUPPRESS_ON] RUN_STOP_FB] SWD_I[VI_C1ST] 3. Check flickering condition of SYS2 LED(green) of DOC-140.
0x91C3 0x9207
0x802A
Coil[SV_INV_
Coil[RS_SUPPRESS_ON] RUN_STOP_FB]
0x9207
0x91C3
check_out
TMC_Start(SUPRS_
ON_OFF_DETECT_T)
TMC_Check(SUPRS_ON_OFF_
DETECT_T, FINISH_STATE) Coil[RS_SUPPRESS_ON]
TCD 90
0x91C3
Even suppress OFF command of operation control side is maintained for 360ms,
the suppress command which is a feedback from speed control side does not
become OFF, and maintain continuously ON.
[Symptom]
[Meaning] Even after 360ms away from driving ON command from operation side [Countermeasures]
to speed side,OFF feedback is maintained.
•1. Check flickering condition of WDT LED(green) of DPC-130.
•2. Check connection condition of communication cable(64P)
[Explanation] between operation and speed.
Coil[SV_INV_ • Check flickering condition of SYS2 LED(green) of DOC-140.
Coil[RS_SUPPRESS_ON] RUN_STOP_FB] SWD_I[VI_C1ST]
0x91C3 0x9207
0x48082
Coil[SV_INV_
Coil[RS_SUPPRESS_ON] RUN_STOP_FB]
0x91C3 0x9207
check_out
TMC_Start(SUPRS_
ON_OFF_DETECT_T)
TMC_Check(SUPRS_ON_OFF_
DETECT_T, FINISH_STATE) Coil[RS_SUPPRESS_ON]
TCD 91
0x91C3
[Explanation]
ALM LED (Red color) on DOC-140 is turned on: Operation unable condition
With speed command is more than 1m/min and C1ST & C1BR is on [Countermeasures]
1. In rope compensation operation, if the pulse of R/E doesn’t change for 4.86 seconds,
the trouble occurs.
1. Check the voltage of AD connector on DOC-140 PCB
2. In other operation (not rope compensation), if the pulse of R/E doesn’t change for
1.62 seconds, the trouble occurs.
When E/L stops running
No.1 pin : 15V±5%(R.E)
Coil[RS_RUNNING] SWD_O[VO_C1BR] SWD_I[VI_C1BR] SWD_I[VI_C1ST] No.2 pin : 0V±0.5 (GND)
No.3 pin : 15V±5% or 0V±0.5
0x91C3 0x9207 0x9207 0x48082 No.4 pin : 15V±5% or 0V±0.5
When E/L is running
SWD_O[VO_C1ST] Coil[IS_CMD_V_1] No.1 pin : 15V±5%(R.E)
check_out
No.2 pin : 0V±0.5 (GND)
0x91C3 0x91C3 No.3 pin : 7.5V±5%(Checked by DMM)
check_out enco_diff == 0
No.4 pin : 7.5V±5%(Checked by DMM)
TMC_Start(ENCODER_
DISCON_DETECT_T 2. Replace Rotary Encoder.
TMC_Check(ENCODER_DISCON_ Coil[RS_ROPE_
DETECT_T,FINISH_STATE) COMPEN_REQUEST]
enco_input_er_cnt++
0x8081
TCD 92
Part: TCD Code
Solon Standard / Trouble Shooting Ctrl No.: Solon(S)-TS-03-0
Page: 58/120
○ Operation CPU
TCD 93 R.E pulse counter read trouble Detection Application Si250
○ Speed CPU
[Meaning] The difference is more than 1mm in reading the value of R.E twice. [Symptom]
[Explanation]
In case the difference that is more than 1mm in reading the value of R.E twice, occurs
more than 10 times, TCD is detected.
[Countermeasures]
[Meaning] In case that the case of changed value between R.E counter value read [Countermeasures]
in current cycle and in the previous cycle exceeds 3 times, and
1. Check SPEC data from address 0100H ~ 0112H of control
this exceeded value is continued for 150ms, the trouble is detected.
SPEC.
2. Check if R.E is out of function. (Refer to TCD 92)
[Explanation]
[Meaning] [Countermeasures]
Off detected from hoist way and safety circuit.
1. Verify that DIP SW2 of SPEC2 is ON position.
2. Key in A21E on annunciator to check the data of address 806D
(Normal : 01).
[Explanation]
3. Key in A21E on annunciator to check the data of address 806E
If the mechanical safety signa(99GA, 99BG)l in hoistway is OFF, (Normal : 01).
it detects an error. If data is ’00’, check the E stop switch on OPB.
4. Check the voltage at each connector. (Be careful of 110V)
GRS(01~02), LSU(01~02, FLS), LSD(01~02,FLS),
Y1(01,11,12,02), HSAF(04,05,07), GRS(09)
[Meaning] [Countermeasures]
In case of ERO(E&I Panel) switch signal and ON_CAR TOCI switch
signal having input concurrent time, or no signal of operation being
inputted at the same time. 1. Enter A21E in DOA-100 KEYPAD, and check data of
address 8064,82AD and 82AF for each electric diagram.
[Explanation] 2. Only one from above 3 input ports should be recognized as
“H”.
TMC_Check(POWER_
READY_T,FINISH_STATE) TCD 200 TCD 202
check_out 4. If there are two or more “H”, check the connection and
voltage of each phase.
0x82AE
0x82AD
CND_F_Op[CN_ON_CAR]
0x82AF
CND_F_Op[CN_IN_CAR] CND_F_Op[CN_ON_CAR]
0x82AE 0x82AF
input_err
990 msec
TMC_Start(OP_MODE_
ERROR_DETECT_T)
empty_err
3060 msec
TMC_Start(MODE_INPUT_
ERROR_DETECT_T)
TMC_Check(OP_MODE_ERROR_
DETECT_T, FINISH_STATE) TCD 96
TMC_Check(MODE_INPUT_ERROR_
DETECT_T, FINISH_STATE)
Part: TCD Code
Solon Standard / Trouble Shooting Ctrl No.: Solon(S)-TS-03-0
Page: 62/120
○ Operation CPU
TCD 97 CDS trouble Detection Application Si250
○ Speed CPU
[Meaning] [Countermeasures]
When CDS is inputted after DOLS operation, the trouble is detected.
SWD_O
[VO_R2OP] SWD_I[VI_LDS]
check_out
0x8083 0x802C
SWD_I[VI_DOLS] SWD_I[VI_CDS]
0x802D
TMC_Check(R2CD_R2LD_ 0x802B
ERROR_DETECT_T,RUN_STATE)
check_out
990 msec TMC_Start(R2CD_R2LD_
ERROR_DETECT_T)
TMC_Check(R2CD_R2LD_
ERROR_DETECT_T,
FINISH_STATE) Coil[DC_DOLS] SWD_I[VI_CDS] TCD 97
0x90A6 0x802B
Part: TCD Code
Solon Standard / Trouble Shooting Ctrl No.: Solon(S)-TS-03-0
Page: 63/120
○ Operation CPU
TCD 98 LDS trouble Detection Application Si250
○ Speed CPU
[Meaning] When LDS is inputted after DOLS operation, the trouble is detected. [Countermeasures]
SWD_O
[VO_R2OP] SWD_I[VI_LDS]
check_out
0x8083 0x802C
SWD_I[VI_DOLS] SWD_I[VI_CDS]
0x802D
TMC_Check(R2CD_R2LD_ 0x802B
ERROR_DETECT_T,RUN_STATE)
check_out
990 msec TMC_Start(R2CD_R2LD_
ERROR_DETECT_T)
TMC_Check(R2CD_R2LD_
ERROR_DETECT_T,
FINISH_STATE) Coil[DC_DOLS] SWD_I[VI_LDS] TCD 98
0x90A6 0x802C
Part: TCD Code
Solon Standard / Trouble Shooting Ctrl No.: Solon(S)-TS-03-0
Page: 64/120
○ Operation CPU
TCD 99 Dual input signal trouble Detection Application Si250
○ Speed CPU
[Meaning] Different contact states of the same inputs between operation CPU and [Countermeasures]
speed CPU exceeds for 300ms. 1. Check trace data of TCD 99 by means of ‘A42E’ trace mode.
2. The meaning of each bit is as left table, in case that ‘1’ is set
at one of bit, meaning of the bit is the reason of trouble.
[Explanation]
err_count ++
b7 b6 b5 b4 b3 b2 b1 b0
[Meaning] [Countermeasures]
SD1D does not operate from bottom floor.
1. Check the value of address 8023 from MEMORY READ
MODE, when car is at top floor. If it is x00, it is normal. If it is x01,
check voltage of LSD-05, LSD-06 and DI-12. They must have
[Explanation] DC 24V.(DC24V is normal)
if not, check wiring and connection.
It is detected when SD1D input does not enter when car is in bottom floor.
2. Check the value of address 8023 from MEMORY READ
TCD 77 TCD 78 TCD 114 ERD_Digi_Fl_Err MODE when car is in bottom floor. If it is x01, it is normal. If it is
x00, check voltage of LSD-06 and DI-12, and They must have
DC 0V.
Coil[SV_ Coil[SW_SS_48V_ Coil[AC_OP_ Coil[AC_OP_FHM_
FORCE_DECEL] DOWN_HOLD] FHM_MODE] START_MODE] 3. Check if SD1 switches works normally.
0x921D 0x923C 0x9031 0x9032
4. Check assembly condition of SD1D
Coil[SW_GS_
OPEN_ZONE] Coil[AC_OP_MAINT_MODE] SWD_I[VI_LDC]
check_out
0x9256 0x9030 0x8025
Coil[IS_ZERO_V]
0x91F2
FTD_Current_Fl ==
check_out SPD_Floor_Spec.Bottom SWD_I[VI_SD1D]
TCD 100
0x8023
Part: TCD Code
Solon Standard / Trouble Shooting Ctrl No.: Solon(S)-TS-03-0
Page: 66/120
○ Operation CPU
TCD 101 SD2D ON trouble Detection Application Si250
○ Speed CPU
[Meaning] [Countermeasures]
SD2D does not operate from bottom floor.
1. Check the value of address 8024 from MEMORY READ
MODE, when car is at top floor. If it is x00, it is normal. If it is x01,
check voltage of LSD-07, LSD-08 and DI-14. They must have
[Explanation] DC 24V.
DC24V is abnormal, check wiring and connection.
Detected only when the rated speed is 90m/min or more.
Detected when SD2D input does not enter when car is on the bottom floor. 2. Check the value of address 8024 from MEMORY READ
MODE when car is in bottom floor. If it is x00, it is normal. If it is
x01, check voltage of LSD-08 and DI-14, and They must have
TCD 77 ERD_Digi_Fl_Err
DC 0V.
TCD 78 TCD 114
Coil[SW_GS_
OPEN_ZONE] Coil[AC_OP_MAINT_MODE] SWD_I[VI_LDC]
check_out
0x9256 0x9030 0x8025
Coil[IS_ZERO_V]
0x91F2
FTD_Current_Fl ==
check_out SPD_Floor_Spec.Bottom SWD_I[VI_SD2D] TCD 101
SPD_Control_Spec. 0x8024
Contract_Velocity >= 90