5/8" Visible Dia. Arc Spot Weld at Chords & Collectors for Shear Transfer
Minimum connections to all supports may be any of the following: arc spot welds, fillet welds,
PAF's, screws, Shearflex® anchors, welded studs or other mechanical connections³.
Chord & Collectors Design Shear Transfer Strength (ΦPn)N = 4382 plf
Notes:
1. For UL Fire rated assemblies, refer to UL Design Number for support & sidelap connection requirements.
2. Minimum connections to supporting members do not contribute to the diaphragm shear strength.
3. Support welds at interlocking sidelaps may be 3/8" x 1 1/4" arc seam welds in lieu of arc spot welds.
4. Sidelap connections between steel deck panels may be VSC2, button punch, screw, 1‑1/2 in. arc seam weld
or 1‑1/2 in. top arc seam weld. The maximum sidelap connection spacing shall not exceed 36 in. o.c.