BOILER DATA SHEET

Company's Name : ____________________________________________________________________ Location : ______________________________


Boiler Operator/Engg.: _________________________________________________________________ Contact No.: ______________________________
Sr. No. Particulars Units Boiler No. 1 Boiler No. 2 Boiler No. 3 Boiler No. 4 Boiler No. 5 Boiler No. 6
1. Basic Boiler Details
1.1 Make/Type
1.2 Year of Manufacture
1.3 Working Pressure
1.4 Hydraulic/Hydrostatic Pressure
1.5 Steam Generation Capacity
1.6 Burner Type:
1.7 Fuel
1.7.1 Baggasse, Rice Husk, Wood Chips, Saw Dust, N/G, LFO, HFO, LPG, LNG
Type of Fuel being Used
1.9 (i.e. Baggasse, Rice Husk, Wood Ships, Saw Dust etc.)
1.10 CO2 Level in Flue Gas %
Location of CO2 Probe
1.11 (After Economiser/ Air Pre Heater)
1.12 Design Pressure of Drum kg./cm2 (g)
1.13 Working Pressure of Drum kg./cm2 (g)
1.14 Working Pressure at Super Heater Outlet kg./cm2 (g)
1.15 Working Temperature at Super Heater OC
Outlet 2. Super Heater Details
2.1 Tubes/Coils for Super Heater Nos.
2.2 O/D of Super Heater Tubes mm.
2.3 Thickness of Super Heater mm.
Tubes 3. Economiser Details
3.1 Tubes/Coils in Economiser Nos.
3.2 O/D of Economiser Tubes mm.
3.3 Thickness of Economiser mm.
Tubes 4. Air Pre Heater Details
4.1 Tubes in Air Pre Heater/ Per Cell/ No. Of Nos.
Cells 4.2 O/D of Air Pre Heater Tubes mm.
4.3 Thickness of Air Pre Heater Tubes mm.
5. Heating Surface Details
5.1 Heating Surface of Furnace Tubes (EPRS for m2
Panels) 5.2 Super Heater m2
5.3 Convection Tubes m2
5.4 Economiser m2
5.5 Air Heater m2
6. Chimney Details
6.1 Chimney Height above Ground Meter
Level 6.2 Inside Diameter of Chimney Meter
at Top 7. Feed Water Mechanism Details
7.1 Feed Water Tank Capacity m3/Hr.
7.2 Height from Centre Line of Pump m3/Hr.
7.3 Available Positive Suction for Meter
Pump 7.4 Design Capacity of Feed m3/Hr.
Pump 7.5 Make & Model No.
7.6 Number of Stages of Pump Nos.
7.7 Total Head as per Designed Meter
7.8 Motor Power as Designed kW
7.9 R.P.M. of Pump Nos.
8. I/D Fan Details (Induced Draft)
8.1 Design Capacity of Fan m3/sec.
8.2 Design R.P.M. of Fan Nos.
8.3 Design Power for Motor kW
8.4 Design Draft for Fan mmWG
OC
8.5 Design Temperature of Flue Gas at Inlet of
Fan 8.6 Actual R.P.M. of Fan (By Pulley/V.F.D.) Nos.
8.7 Actual Draft of Fan mmWG
OC
8.8 Actual Inlet Temperature of Flue Gas
8.9 Actual Damper Opening %
9. F/D Fan Details (Forced Draft)
9.1 Design Capacity of Fan m3/sec.
9.2 Design R.P.M. of Fan Nos.
9.3 Design Power for Motor kW
9.4 Design Draft for Fan mmWG
OC
9.5 Design Temperature of Flue Gas at Inlet of
Fan 9.6 Actual R.P.M. of Fan (By Pulley/V.F.D.) Nos.
9.7 Actual Draft of Fan mmWG
OC
9.8 Actual Inlet Temperature of Flue Gas
9.9 Actual Damper Opening %
10. S/A Fan Details (Secondary Air)
10.1 Design Capacity of Fan m3/sec.
10.2 Design R.P.M. of Fan Nos.
10.3 Design Power for Motor kW
10.4 Design Draft for Fan mmWG
OC
10.5 Design Temperature of Flue Gas at Inlet of
Fan 10.6 Actual R.P.M. of Fan (By Pulley/V.F.D.) Nos.
10.7 Actual Draft of Fan mmWG
OC
10.8 Actual Inlet Temperature of Flue Gas
10.9 Actual Damper Opening %