TEST CERTIFICATE, Concerning examination, load test and controling of Spreader. Examination made : 2008-12-23 12. Customer : Shanghai Zhenhua Port Machinery Co., Ltd Enduser : Salalah Adjustable hoisting gear for ISO container 20’, 40° & 45° Type : YSX 45E Serial Number : 11383 Manufacturer : Bromma ( Malaysia ) Sdn. Bhd General drawing : 1021187 Material : High Tensile Steel & Fine Grain Steel Spreader weight : 6.7 Tone Load test carried out with a max. of 150% overload Safe Working Load (SWL) : Single 40.6 tonne Test load of twistlocks to 37 tonne for serial number SINGLE : WM 8200, WM 6758, WM 6514, WM 4834. As a result of this examination we the undersigned find nothing which will prevent the use of above load gear for the loads presented in the data sheet. Remarks : The load gear is to carry attached signs stating manufacturer, production number, year of manufacture and SWL — max. load. Enclosed: Spreader data sheet Malaysia 2008-12-23 Bromma ( Malaysia ) Sdn. Bhd Lot 19, Jalan Kelebang 1/6, Zon Perindustrian Bebas Kinta, 31200 Chemor, Perak MALAYSIA -7 (BROMAA pie Mohaingd Shawal | QC DEPARTMENT | BRMYFORMOS3v0 TWISTLOCK-CERTIFICATE CUSTOMER. ZPMC / Salalah, Oman CUSTOMER ORDER NO. ZP08-1147-9 BROMMA SPREADER / ORDER NO. 11383 DATE. 23” December 2008 This is to certify that the following twistlocks have been proof tested to 37 tonne’s load. No visible deformation occured. The twistlocks have been stamped on the end face with a B/C stamp and 37 tonne QTY. TYPE. DWG. MATERIAL. PARTNo. SERIAL No. MILL CODE 4PCS ISO —- 1000431 SS 2541-03 1000431 1.WM 8200 W84 2. WM 6758. W83 3. WM 6514 ws3 4, WM 4834 weo ARO) SIGN B- DATE | 23" December 2008 BRMYEORMOS4v0 Bromma (Malaysia) Sdn. Bhd. (company No: 329509-7) Lot 18, Jalan Kelebang 1/6, Zon Perindustrian Bebas Kinta, Telephone: +6-05-293 8890 Telefax: +6-05-291 4099 31200 Chemor, Perak Darul Ridzuan, Malaysia Website: www:bromma.com DIMENSIONAL AND VISUAL REPORT. BROMMA SALALAH Model : YSX 45E Drawing No : | 1021187 [articieNo: [1021187 Serial No: 11383, 4. General Assembly Main Beam Main Beam No a 3667 8 3668 Location Dasign | Tolerance | Actual Deviation | Remarks. A 5436. 22 5435 ot 8 5436 32 5435 4 c 1218 205 1219) 3 D Hi 405 1218 o E S571 22 3570 = F S571 22 5570 ot 2, Dimensional Inspection Satisfactory | Not Satisfactory Rectity Resuk ‘Above Dimensional Inspection Result Note : The measurement point between headblock must be address between center polt of the headblock ~ twistlock pocket. Before checking, QC must confiem the twistlock hole cantar marking. center Pointa—| 3. Visual Welding Inspection Satistactory | Notsatistactory Rectty Resuit Visual Welding Inspection Result v Note: The Weld Quality / Visual Welding Acceptance Criteria shall comply according to BS EN ISO 5617. Inspected By : _Sporoved By : ( ACCEPTED Kong Rum Choy Name N oo DDésignation : Superintendent Designation: Fab, Inspector BRMYFORMO08v0_(STD) Date'® DEC 2008 Date:9 DEC 2008 BROMMA DIMENSIONAL AND VISUAL REPORT Client : zPpmc End User: | SALALAH Model YSX 45E Drawing No : | 1021187 Article No : | 1021187 SerialNo: | 11383 1. General Assembly Telescopic Frame | Telescopic Beam No 7628 83024 |B 3025 C476 32053 | B3014 Location Resuit_ | Tolerance | Deviation Remarks A eT AVeB E 8 sez] ot A ——e 2258 a4 eso D PBB a a E e272 3 Ewe F ear = ° 2. Dimensional Inspection Salstctory | Not Saisactory Roctily Result Above Dimensional Inspection Result 4 3. Visual welding Inspection ‘Satisfactory Rect Result Visual Welding Inspection Result v Note : The Wold Quality / Visual Welding Acceptance Criteria shall comply according to BS EN ISO 8817, Inspected By ‘Approved By : ACCEPTED _ ‘Z ae Chay Nae a rm ‘BROMMA (MW) SON. BHD. Designation Suprtendent Designation Fab, nspecor Date 0EC 2008 (Date:18 DEC 2008 BRMYFORMO08v0_(STD) BROMMA ‘QUALITY ASSURANCE DEPT [Date : 15 DEC 2008 [Sheet : 1 of 7 MAGNETIC PARTICLE INSPECTION : FINAL INSPECTION REPORT Client _ : ZPMC/SALALAH Model :YSX45E | DWGNo. _:1021187 End User : ZPMC/SALALAH Serial No. 41383 ArtNo. _:1021187 | Test Equipment Chemical Used | Magnaflux | White Contrast Paint wor2 Equipment Used | Yoke YS Magnetic Ink | THE CleanerRemover | _ SKC-S ITEM INSPECTED: AS SHOWN Gear Si Pulley Side Location | Result | Judgment Location | Result | Judgment 1 NSD ACCEPT 4 NSD ACCEPT 2 NSD_| ACCEPT 2 NSD__|_ ACCEPT 3 NSD_| ACCEPT 3 NSD | ACCEPT 4 NSD ACCEPT 4 NSD ACCEPT 3 NSD_| ACCEPT | 3 NSD__| ACCEPT é NsD_|ACCEPT_| 6 NSO__| ACCEPT T NSD_|_ACCEPT | T NSD__|_ ACCEPT @ NSD_|ACCEPT_| 3 sD [ACCEPT 9 NSD ACCEPT | 9 NSD ACCEPT 70 | NSD_| ACCEPT 40 NsD__|_ ACCEPT 71 |_NSD_| ACCEPT 1 sD [ACCEPT Note: NSD- No Significant Defect Judgment - Accept / Reject “ Name TFAIZAL BBE Designation *- FAB. INSPE Qualification - ASNT LEVEL I Note: Acceptance criteria of the Al finishing and rough edges shall bé smoothly rounded. BRMYFORMO15v2_11383 BROMMA BROMMA ( M ) SDN BHD rasonic Testing Report-Main Beam Auto Welding Project zPMC. ‘Serial Number : 11383 End user SALALAH,OMAN Mode! YSK 45E. - BeamNo. : 367.3668 Date 1-Deco8 JOINT DETAILS Materia Thlknass@= 10mm & 30mm, b= 8mm ir Joint Type Filet weld wth bevel Welding Process: Rapid Arc ‘Surface Conditen : Clean Satstactory CCouplant: Wall Paper Paste TESTING DETAILS. |law Detector: EPOCH Il SN: $200 / EPOCH XT SIN 081105503 (caitraton block :V1,V2 & Bromma reference block 'Sensivy: BS EN 883.2 2001 [scanning Technique Transverse Later Orbital & Swivl Probe Frequency Siz0 Rotel Scanning 68 ange 009 a MR a e rm 48009 me 7 3 oe mm 60029 Tae TZ ne nm 80 Deg x tly J. i Discontina “Top Plate Ret |acication Num ransducer Angle © Reference Level einaicabon Rating [Sound Path [oepin From Surtace A Fem rom ToSignicar adeation Tio Santicantnaeaion Tio Significant Indeaton No Siaifeantndcaton [attenuation factor Note : Attenuation factor is not taken into consideration because sensitivity is set ona similar material the test spocimer fe, he undersigned, cory that ‘and tested in accordance with nis in this record are correct and tha he weld prepared BSENI712, Nave Fag basi Designation Fab inspeck Qualfcaton: ASNT Level ‘BRMYFORMO16¥0_Batom_11989 LOTT INSPECTION SDN. BHD cones rs:12080 N12 J 237 ne Sy nt, i Tl Rad L@I1 sre ea oye {wos sina ae a Erle ny ou ences ULTRASONIC TESTING REPORT ClientsBromma (Mf) Sdn Bhd Report No. TBROMMA/2008(712) Page 172 Project: ZPMC Salalah, Oman. Date of Insp’ 13 December 2008 [Job Description: — Ultrasonic Testing of Welds on Telescopic Beam SIN : 11383 Procedure No BC-200701 [Speeification: ENS83-1:1999 [Technique Sht. No:_8C200701 APPENDIX Equipment KK USM 35__ SIN: 808A. mn Range: 0~100mm ‘Surface Condition: _ Smooth Setting: BS EN 83.2. 2001 Cellulose paper paste [Welding Process: fp Pocesing Carbon steel Thickness: 8mm Weld Preparation: Fillet Weld [Joint Configuration: Toit be] Anate Sie Frequency Phoenix | Osw 80° 5x9 mm Miz \s. Trusone_| nor o omm @ aMHz feat Treatment: [Parent Metal: No Lamination Was Detected lem Tested and Result(s: i Result Beam No. Model | Joint No. Interpretation aot al 3008 YSxaSE__| JTABGD | No Relevant indication Was Deteced y 3025 ysx43e__| ABCD | Wo Relevant Indication Was Detected v 22953 ysx4se__[ TABCD | _ Wo Relevant Indication Was Detected v 08 YSx45E | FTABCD | _ NoRelevant indication Was Detected v [Remark(s): Resul(s) reported above isiare atthe te of inspection. INote: Testing standard reference to EN1714 and ENSB3 1 Acceptance criteria to EN1712. Inspection was carried out before 48 hours after completed weld. Inspector: Signature Date: LOTT INSPECTION SDN. BHD coma xo::2050) Poo 17 L@IT Sr bs Sek. ee : “oo a0an517 Fa 1 Ena gE LY cua snes ULTRASONIC TESTING REPORT Client:Bromma (M) Sdn. Bhd. Report No. UT/BROMMA/2008(712) Page 2/2 Project: ZPMC Salalah, Oman Date of Insp" 13 December 2008 [Job Description: Ultrasonic Testing of Welds on Telescopic Beam S/N : 11383, Sketch: x a GTA x K, Gro) Gr arch | |, oa {100mrp at e, yy i) ira [Remark(s): Drawing not to scale Ultrasonic Testing was carried out not inclided 100mm from the edges of the welding joints QT A,JT BJT C and JT D). inspector: Signature Date: Sh Alon Ofc 4D. Agger Moke 364, Saye 31, Kat KeSBRIRE 10706 Shh Al, henge Tel; DI-SDAOTI4 Fa 324074 Single lft with two brackets Proofloading Bromma Spreader YSX 45E Customer ZPMC / Salalah, Oman Serial Nr. 11383 General Ass. dwg. 1021187 Safe Working Load 40.6 Tonne Proof Load 150% Tonne Tare weight 6.7 Tonne Weight of Testequipment 2 Tonne Cylinders used 4 Pressure From Pump |Load In Tonne Meassure point mm ln Bar Load [Load 4 cyl jin each jin each IA =71,2cm2_ [Cylinder |Twistlock 3 4 28 2 2 73] 85 84) 140) 141 10 9 134] 142|—143 165 211 15) 157) 172) 169| 168) 281 20) 18) 183 196 190] 172| 28} 2 2 75 86 86) 140) [UNDER SUPERVISION OF DATE MOHAMED SHAWAL 3rd Dec 2008 BRMYFORMO18v1

You might also like