TEST CERTIFICATE Concerning examination, load test and controlling of Spreader. Examination made : 2008-12-22 1 Customer : Shanghai Zhenhua Port Machinery Co., Ltd Enduser : Salalah Adjustable hoisting gear for |SO container 20’, 40’ & 45° Type : YSX 45E Serial Number : 11381 Manufacturer : Bromma ( Malaysia ) Sdn. Bhd General drawing : 1021187 Material : High Tensile Steel & Fine Grain Steel ©PNORE EN Spreader weight : 6.7 Tonne Load test carried out with a max. of 150% overload s 14 Safe Working Load (SWL) : Single 40.6 tonne 42, Test load of twistlocks to 37 tonne for serial number SINGLE : WM 8167, WM 8196, WM 8188, WM 8179. As a result of this examination we the undersigned find nothing which will prevent the use of above load gear for the loads presented in the data sheet. Remarks : The load gear is to carry attached signs stating manufacturer, production number, year of manufacture and SWL — max. load. Enclosed: Spreader data sheet Malaysia 2008-12-22 Bromma ( Malaysia ) Sdn. Bhd Lot 19, Jalan Kelebang 1/6, Zon Perindustrian Bebas Kinta, 31200 Chemor, Perak MALAYSIA, BRMYFORMOS3v0 TWISTLOCK-CERTIFICATE BROMMA CUSTOMER. ZPMC / Salalah, Oman CUSTOMER ORDER NO. ZP08-1147-9 BROMMA SPREADER / ORDER NO. 11381 DATE. 22" December 2008 This is to certify that the following twistlocks have been proof tested to 37 tonne’s load. No visible deformation occured. The twistlocks have been stamped on the end face with a B/C stamp and 37 tonne. Qry. TYPE. DWG. MATERIAL. PARTNo. SERIAL No. MILL CODE 4PCS Iso 1000431 SS 2541-03 1000431 1.WM 8167 ws84 2. WM 8196 ws84 3. WM 8188 we84 4, WM 8179 we84 QA& QCDBPARTMENT SIGN] Ze DATE | 22” December 2008 —BRMYEORMNS4y0_ Bromma (Malaysia) Sdn. Bhd. (company No: 329509-7) Lot 18, Jalan Kelebang 1/6, Zon Perindustrian Bebas Kinta, Telephone: +6-05-293 8890 Telefax: +6-05-291 4099 31200 Chemor, Perak Darul Ridzuan, Malaysia. Website: werw-bromma.com DIMENSIONAL AND VISUAL REPORT BROMMA Client : zemc End User ‘SALALAH Model : YSX 45E Drawing No : | 1021187 Article No : 1021187 Serial No: 11381 1. General Assembly an Baa ain Bean Wo] t 3581 B T 3652 |____Location _| Actuz Deviation Remarks 5436 42 5436, Q 5856 $2 —| 5436 a "re [sts | g ae —| ses} — 8 ¢ ont a x eT am 3 nal Inspection Satisfactory | Not Satisfactory Rectty Result Above Dimensional Inspection Result New: The pasar pat nen hese address between center point of the headblock oY se te a ternn 2 pstaeti ‘Center Point¢— 4 3. Visual Welding Inspection ‘Satisfactory | Not satisfactory Rectiy Result Visual Welding Inspection Result v ot: Te Wi a Yun lg Asap Canta oS en opr ACCEPTED Cu dae : Tae na BROW) SOME.) natn: Supine Becraten Fa Soa necls a oEE RS BRMYFORMO08V0_(STD) DIMENSIONAL AND VISUAL REPORT Client : zpmc End User: | SALALAH Model : YSX 45E Drawing No : | 1021487 Article No: | 1021187 Serial No: | 11381 1. General Assembly Telescopic Frame | Telescopic Beam No 7605 82933 |B 2936 7608 8293882949 Location Result | Tolerance | Deviation Remarks a 3652 AVSB 5 EH 23 G - c 2258 a ene D 258 a E B22 EVsF £3 F eae | ‘on 2. Dimensional inspection Satistactory | Not Saistactory Rectfy Resut Above Dimensional inspection Result Y 3. Visual welding Inspection ‘Satisfactory | Not satisfactory Reetily Result Visual Welding Inspection Result v Note: The Weld Qualty/ Visual Welding Aceoptance Criteria shall comply according to 8S EN ISO E67. aaeaAer: RaaaeT: ACCEPTED as wy ie ae ‘BROMMA (M) SON. BHO. Designation: Superintendent Designation Fab, Inspector Date:10 DEC 2008 [ Date-10 DEC 2008 BRMYFORMO08v0_(STD) BROMMA QUALITY ASSURANCE DEPT [Date : 10 DEC 2008 [Sheet : 1 of 1 MAGNETIC PARTICLE INSPECTION : FINAL INSPECTION REPORT Client — : ZPMCISALALAH ~ [Model Sx ase | OWGNo, 1027187 | End Uso? : ZPMGISALALAH [SevalNo.:11381 | ArtNo. 1021787 | Test Equipment _ Chemical Used | Magnafie | White Convast Pant | WOP-3 | Equiment Used | Yoke ¥6 | Magnetic nk THE CleanerRemover | SKCS ITEM INSPECTED: AS SHOWN 1 { 3 Gear Side Pulley Side Location | Resuit_| Judgment Location | Result _| Judgment 1 NSD | ACCEPT 1 NSD | ACCEPT 2 NSD__| ACCEPT 2 NSD__| ACCEPT 3 NSD_| ACCEPT 3 NSD__| ACCEPT 4 NSD__| ACCEPT 4 NSD__| ACCEPT 5 NSD__| ACCEPT 5 NSD__|_ ACCEPT 6 NSD_| ACCEPT 6 NSD__| ACCEPT 7 NSD__| ACCEPT 7 NSD__| ACCEPT & NSD__| ACCEPT 8 NSD__|_ ACCEPT 3 NSD__| ACCEPT 3 NSD__| ACCEPT 10 NSD__| ACCEPT 10 NSD__|_ ACCEPT 1 NSD_| ACCEPT 11 NSD__| ACCEPT Note: NSD- No Significant Defect Judgment - Accept / Reject Visual Welding Inspection: Satistacto Inspected By FAIZAL 40 ws TENEL 1 wut / AU Name FFAIZAL BINDASIRY» Designation FAB. INSPECTOR CQ» Quaification "ASNT LEVEL It Note: Acceptance criteria ofthe weld qlaltyhall comply wth the requirements of BS EN 1291 Ail finishing and rough edges shall be smoothly rounded BRMYFORMO15V2_11381 BROMMA BROMMA ( M) SDN BHD Ultrasonic Testing Report-Main Beam Auto Welding Project zPMC. Serial Number : 31381 Enduser SALALAH,OMAN Mode! YSK 45E Beam No. | 3651,3652 Date 26-Nov-08 JOINT DETAILS. Mater Thickness :a= 10 mm & 30-mm, Jott Type Filet wed wth bevel Weiding Process: Rapis Are ‘Surface Condon : Clean Satstactony CCouplant: Wall Paper Paste =emm TESTING DETAILS. Fw detector EPOCH Il SIN 3200/ EPOCH XT SIN 081105503, Jtraton block V1.V2 & Bromma reference bloc Isererwty: 8 EN 583-2 2003 [scanning Technique Transverse Lateral Orbital & Swival Prove Frequency Sze Retteve! Scanning 68 Range O99 eo Mise mm Be Be Bm 45009 time m8 oe nm ‘De ie Sm oe em 0009 Came 8XE mm 6B Sew a Sm TEST RESULT INTERPRETATION no WELD IDENTIFICATION ue ACCEPT REJECT pene) 1 [it was cared out on aio welding int JS —— tan beam Note - enoncs oints accepted based on aeceptance level indicated inthe documentation tem BC-200701 No relevant incicaton was found xing inspection te, NOTE. Name: Fazal Basir Designation “Fab Insp Qualfcatn : ASNT Level I Testing standard reference to 589.1. Acceptance citra reference to EN 1712 BRONUAA [BROMMA (MALAYSIA) SDN BHD ULTRASONIC INSPECTION REPORT - MAIN BEAM - TOP PLATE, Cont zeMc Soria No. 11381 End User: SALALAH,OMAN Model YSK 45 Date [raat cmon Tone TS ‘Sketch srt Desgn Doubs ce Jie Process FCAW Discontinul [ranssucer Angle \tenvatin factor engin Discontinuity Evaluaton lrdicaton Number hes = lincication Rating © lncicton Lev! Fem [ron Na Sigs indestion ‘a Signiicant indication a Sighicant ination a Signicant indication nee Note: Attenuation factor isnot tajge info consideration because as the test specimen, Li sitivity is set on a similar material rs inthis record are corect ang that the wad prepared SEN 1712 We, the undersigned, comity and tested in accordance Designation Fab inspec ‘Quatfeaton- ASNT Level ‘BRUYFORMOY6¥0_Top_11981 ‘BROMMA BROMMA (MALAYSIA) SON BHD ULTRASONIC INSPECTION REPORT - MAIN BEAM - BOTTOM PLATE Clint =: 2PM 11381 End User: SALALAH.OMAN YSX 456, Date 5 28-Nov-08 era Reese ToT Sa Sketch [ine Desgn Doub |rcking Process FAW A Top Pata Ret lndication Number length th From Surface hes © atenuation factor = inaication Rating | eterence Level = |ncication Level Fem [Fon i SgAcannceation Tio Sigiticant Indeation ‘io Sgniicantindeaton io Sigaticant ington 43 the tostspecimon We, the undersigned, cot th nd tested nsccordance wired ape ull Designation Fab isp ‘Quaificatén : ASNT Level I ermvronwcio0 soten iiss N\A L@IT uurRERvces | LOTT INSPECTION SDN, BHD cconays:1245 a2 Lt 220k 2 Sy seta, Bl Tal Re. 7010 ly, Sark Moya eon tcaaaest2 Fa C12 Eat mem etry ULTRASONIC TESTING REPORT Bromma (M) Sdn. Bhd. Report Noz UT/BROMMA/2008(690) Page 12 Project: ZPMC Salalah, Oman Date of Insp'n: 09 December 2008 [Job Deseription: Ultrasonic Testing of Welds on Telescopic Beam SIN : 11381 Procedure BC-200707 [Specification: ENS83-11999 BC-200701_APPENDIXT [Equipment KK USM35__ S/Ni_7607A, 2091, 808A 0=100mm Smooth BSEN 583-2 2001 Cellulose paper paste Rapid Processing Carbon steel Thickness: Smm Fillet Weld Probe Detail [foint Configuration-T-Joint Made | tye Angle Size Frequency Phoenix | asw a $49 mm Mie las Trusonig_[ nor o 10mm Mite Ne ‘No Lamination Was Detected rem Tested and Result 5): 5 Result Beam No, Model | Joint No. Interpretation Teal eet 2983 ysx4se__ [iT ABCD | _NoRelevant ndieation Wes Deected Y 22986 ysx-isé_ [77.8 | NoRelevan indication Was Detected y 2938 YSX45E JT ABCD [No Relevant Indication Was Detected v 2949 ysxase | FTABGD | _ NoRelevant indication Was Detected v IRemark(s): Resul(s) reported above Wlare atthe tine of mepecton Note: Testing standard reference to EN1714 and ENS83.1 Acceptance criteria to EN1712. Inspection was carried out before 48 hours atter completed weld. a ‘Tang. H.Y/ Syazill/ Shahrin Signature LOTT INSPECTION SDN. BHD comm xe:12480 "No.2 Lot 2370 Bleck 2 Siu nus Este Tala Rod, Peo br Li TT 87010 Brady, Sarawak, Maya Tet oe sensi? Fac TaN Eat sGIneiny oan Ewes _ ULTRASONIC TESTING REPORT Client:Bromma (M) Sdn. Bhd. Report No.: UT/BROMMA/2008(690) Page 2/2 Project: ZPMC Salalah, Oman Date of Insp'n: 09 December 2008 Job Description: _ Ultrasonic Testing of Welds on Telescopic Beam SIN : 11381 Sketch: x we UTA. ore t— x JT " Ny JT AI Gr irs Nal LA i} re |Remark(s): Drawing not to scale Ultrasonic Testing was carried out not included 100mm from the edges of the welding joints QT AJT BITC and JT D), ltnspector: Signature Date: ‘Shah Alam Off, Anas Moka 316483 3A Ko Ka Alm lego Tel: 0521036 Fae 824074 Single lft with two brackets Proofloading Bromma Spreader YSX 45E Customer ZPMC/ Salalah, Oman Serial Nr. 11381 General Ass. dwg. 1021187 Safe Working Load 40.6 Tonne Proof Load 150% Tonne Tare weight 6.7 Tonne Weight of Testequipment 2 Tonne Cylinders used 4 [Pressure From Pump [Load In Tonne ‘Meassure point mm lin Bar Load Load 4 cyl. jineach [in each |A =71,2.cm2_|Cylinder |Twistlock 1 2 3 4 5 28 2 2[__ 142 67 74 @ 139 141 9[__ 166,132 211 14[___169| 153 281 138|173|___—*173; 28 2,143; 70 [ONDER SUPERVISIO: IWAN MOHD NOR 22nd Dec 2008 BRMYFORMO18v1

You might also like