ﻣﺴﺎﻋﺪﺓﺳﻤﺎﺭﺕ ﻓﻼﺵ
ﺁﺧﺮﺗﻌﺪﻳﻞ ﻓﻲ 19ﺳﺒﺘﻤﺒﺮ 2018
.ﻳﻤﻜﻦﺑﺮﻣﺠﺔ ﺻﻮﺭﺗﻴﻦ ﺗﻄﺒﻴﻘﻴﺘﻴﻦ ﻣﺴﺘﻘﻠﺘﻴﻦ ﻓﻲ ﻣﺴﺎﺣﺔ ﺍﻟﻔﻼﺵ .ﻳﺘﻢ ﺗﻮﻓﻴﺮ ﺧﻴﺎﺭ ﺇﺿﺎﻓﻲ ﻟﺘﺤﺪﻳﺪ ﺃﻱ ﻣﻦ ﻫﺬﻩ ﺍﻟﺼﻮﺭ ﺳﻴﺘﻢ ﺗﺸﻐﻴﻠﻬﺎ ﺍﻓﺘﺮﺍﺿﻴﺎً 3000 )68-6201("،
"OMNI 6000/ﺑﺎﻟﻨﺴﺒﺔ ﻟـ "SmartBus )LMC/RMC(".ﺃﻭ ﻟﻮﺣﺔ ﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ "( "OMNI 6000/3000 )68-6201ﺃﻭ "(7000/4000 )7201
"OMNIﻋﺒﺎﺭﺓ ﻋﻦ ﺃﺩﺍﺓ ﻣﺴﺎﻋﺪﺓ ﻟﺒﺮﻣﺠﺔ ﺻﻮﺭ ﺍﻟﺘﻄﺒﻴﻘﺎﺕ ﻓﻲ ﺫﺍﻛﺮﺓ ﻓﻼﺵ ﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ )ﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ( ﻭﻣﺴﺢ ﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ )
ﺫﺍﻛﺮﺓﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ( ﺍﺧﺘﻴﺎﺭﻳﺎً ﻋﻠﻰ SmartFlash
ﺇﻋﺪﺍﺩﺍﺕ
ﺍﻟﻌﻨﺎﺻﺮﺍﻟﻤﺪﺭﺟﺔ ﺃﺩﻧﺎﻩ ﻫﻲ ﻭﺻﻒ ﻟﻜﻞ ﺧﻴﺎﺭ ﺇﻋﺪﺍﺩ .ﺍﻧﻘﺮ ﻋﻠﻰ ﺍﻹﻋﺪﺍﺩ ﻟﻤﺰﻳﺪ ﻣﻦ ﺍﻟﻤﻌﻠﻮﻣﺎﺕ.
ﺍﻟﻮﺣﺪﺓﺍﻟﻤﺴﺘﻬﺪﻓﺔ
ﺣﺪﺩﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ ﻟﻠﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ ﺍﻟﺘﻲ ﺗﻌﻤﻞ ﻣﻌﻬﺎ .ﺍﻟﺘﺤﺪﻳﺪﺍﺕ ﻫﻲ:
ﺃﻭﻣﻨﻲ(6201-68) 6000/3000 ﻝ
ﻣﻠﻒﻓﻼﺵ
ﻣﻠﻒﺍﻟﻔﻼﺵ ﻫﻮ ﻣﻠﻒ ﺍﻟﺒﺮﻧﺎﻣﺞ ﺍﻟﺜﺎﺑﺖ ﺍﻟﺬﻱ ﻳﺘﻢ ﺇﺭﺳﺎﻟﻪ ﺇﻟﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ .ﺍﺳﺘﺨﺪﻡ ﺍﻟﺰﺭ "ﺗﺤﺪﻳﺪ" ﻻﺧﺘﻴﺎﺭ ﻣﻠﻒ ﺍﻟﻔﻼﺵ .ﻳﻈﻬﺮ ﻣﺮﺑﻊ ﺣﻮﺍﺭ "ﻓﺘﺢ ﻣﻠﻒ"
ﻗﻴﺎﺳﻲﻟﻠﺴﻤﺎﺡ ﻟﻚ ﺑﺎﻟﺘﺼﻔﺢ ﺑﺤﺜﺎً ﻋﻦ ﻣﻠﻒ ﻓﻼﺵ ﺑﺎﻣﺘﺪﺍﺩ " ."bin.ﻟﺘﺤﺪﻳﺪ ﻣﻠﻒ ،ﺍﻧﻘﺮ ﻓﻮﻕ ﺍﻟﻤﻠﻒ ﺛﻢ ﺍﺿﻐﻂ ﻋﻠﻰ "ﻓﺘﺢ" .ﻳﺘﻢ ﻋﺮﺽ ﺍﺳﻢ ﻭﻣﺴﺎﺭ ﺍﻟﻤﻠﻒ ﺍﻟﻤﺤﺪﺩ
ﻟﻠﺮﺍﺣﺔ.
ﺻﻮﺭﺓﻓﻼﺵ)ﺃﻭﻣﻨﻲ 6201-68ﻓﻘﻂ(
ﻳﻮﺟﺪﻣﺎ ﻳﺼﻞ ﺇﻟﻰ ﺻﻮﺭﺗﻲ ﻓﻼﺵ ﻳﻤﻜﻦ ﺗﺨﺰﻳﻨﻬﻤﺎ ﻓﻲ ﻟﻮﺣﺔ ﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ .OMNI 68-6201ﺇﺫﺍ ﻛﺎﻧﺖ ﻫﻨﺎﻙ ﺻﻮﺭﺓ ﻣﺨﺰﻧﺔ ﺑﺎﻟﻔﻌﻞ ،ﻓﺴﻴﺘﻢ ﻋﺮﺽ
ﺇﺻﺪﺍﺭﺻﻮﺭﺓ ﺍﻟﻔﻼﺵ .ﺑﻌﺪ ﺗﺤﺪﻳﺪ ﻣﻠﻒ ﻓﻼﺵ ،ﻳﺘﻢ ﺗﻤﻜﻴﻦ ﺗﺤﺪﻳﺪ ﺻﻮﺭﺓ ﺍﻟﻔﻼﺵ .ﺣﺪﺩ ﻣﻨﻄﻘﺔ ﺍﻟﺼﻮﺭﺓ ) 1ﺃﻭ (2ﺍﻟﺘﻲ ﺗﺮﻏﺐ ﻓﻲ ﺇﺭﺳﺎﻝ ﻣﻠﻒ ﺍﻟﻔﻼﺵ ﺇﻟﻴﻬﺎ.
ﺻﻮﺭﺓﺍﻟﺘﻤﻬﻴﺪ)ﺃﻭﻣﻨﻲ 6201-68ﻓﻘﻂ(
"ﺻﻮﺭﺓ ﺍﻟﺘﻤﻬﻴﺪ" ﻫﻲ ﺍﻟﺼﻮﺭﺓ ) 1ﺃﻭ (2ﺍﻟﺘﻲ ﻳﺘﻢ ﺗﻨﻔﻴﺬﻫﺎ ﻋﻨﺪ ﺇﻋﺎﺩﺓ ﺿﺒﻂ OMNIﺃﻭ ﺗﺸﻐﻴﻠﻪ .ﺭﺍﺟﻊ ﻗﺴﻢ "ﺻﻮﺭﺓ ﺍﻟﻔﻼﺵ" ﻟﻤﻌﺮﻓﺔ ﺍﻹﺻﺪﺍﺭ ﺍﻟﻤﺜﺒﺖ ﻓﻲ
ﺍﻟﺼﻮﺭﺗﻴﻦ 1ﻭ.2
ﺧﻴﺎﺭﺍﺕﺍﻟﻔﻼﺵ
ﺍﻝ'ﺍﻟﺘﺤﻘﻖ ﻣﻦ ﺍﻟﻔﻼﺵ' ﻳﺘﺤﻘﻖ ﻣﻦ ﺃﻥ ﺑﺮﻧﺎﻣﺞ ﺍﻟﻔﻼﺵ ﺍﻟﺬﻱ ﺗﻢ ﺇﺭﺳﺎﻟﻪ ﺗﻤﺖ ﺑﺮﻣﺠﺘﻪ ﺑﺸﻜﻞ ﺻﺤﻴﺢ ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ.
ﺇﺫﺍﺗﻢ ﺗﻨﻔﻴﺬ ﺍﻟﺨﻴﺎﺭ ﺑﻨﺠﺎﺡ ،ﻓﺴﻴﺘﻢ ﻋﺮﺽ ﻣﺮﺑﻊ ﺃﺧﻀﺮ ﻣﻊ ﻋﻼﻣﺔ ﺍﺧﺘﻴﺎﺭ ﺑﺠﻮﺍﺭ ﺍﻟﺨﻴﺎﺭ .ﺇﺫﺍ ﻟﻢ ﻳﻨﺠﺢ ﺍﻟﺨﻴﺎﺭ ،ﻓﺴﻴﺘﻢ ﻋﺮﺽ ﻣﺮﺑﻊ ﺃﺣﻤﺮ ﺑﻪ ﻋﻼﻣﺔ "."X
ﺍﻝ'ﻣﺴﺢ ﻛﺎﻓﺔ ﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲﻳﻘﻮﻡ ﺍﻟﺨﻴﺎﺭ ﺑﻤﺴﺢ ﺟﻤﻴﻊ ﺑﻴﺎﻧﺎﺕ ﺍﻟﺘﻜﻮﻳﻦ ﻭﺍﻟﻤﺠﻤﻮﻉ ﻭﺍﻟﻤﻌﺎﻳﺮﺓ ﻓﻲ ﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ ).(RAMﻣﻼﺣﻈﺔ :ﺗﺘﻢ ﺍﺳﺘﻌﺎﺩﺓ
ﺑﻴﺎﻧﺎﺕﺍﻟﻤﻌﺎﻳﺮﺓ ﻣﻦ ﻣﺨﺰﻥ ﺍﻟﻨﺴﺦ ﺍﻻﺣﺘﻴﺎﻃﻲ ﻋﻨﺪ ﺑﺪء ﺗﺸﻐﻴﻞ ﺍﻟﺘﻄﺒﻴﻖ.
ﺍﻝ'ﻣﺴﺢ ﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ ﺍﻟﺘﻜﻮﻳﻦﻳﻘﻮﻡ ﺍﻟﺨﻴﺎﺭ ﻓﻘﻂ ﺑﻤﺴﺢ ﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ ) (RAMﻟﻠﺘﻜﻮﻳﻦ ﻭﻳﺘﺮﻙ ﺟﻬﺎﺯ ﺍﻟﺘﺠﻤﻴﻊ ﻭﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ ) (RAMﻟﻠﻤﻌﺎﻳﺮﺓ ﺳﻠﻴﻤﺔ.
ﻳﺆﺩﻱﺗﺤﺪﻳﺪ ﺃﻱ ﻣﻦ ﺍﻟﺨﻴﺎﺭﻳﻦ ﺇﻟﻰ ﺑﺪء ﺇﻋﺎﺩﺓ ﺿﺒﻂ ﺍﻟﻨﻈﺎﻡ ﻋﻠﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ ﻭﺑﺪء ﺍﻟﺘﻄﺒﻴﻖ ﺍﻻﻓﺘﺮﺍﺿﻲ.
ﺇﺫﺍﺗﻢ ﺗﻨﻔﻴﺬ ﺍﻟﺨﻴﺎﺭ ﺑﻨﺠﺎﺡ ،ﻓﺴﻴﺘﻢ ﻋﺮﺽ ﻣﺮﺑﻊ ﺃﺧﻀﺮ ﻣﻊ ﻋﻼﻣﺔ ﺍﺧﺘﻴﺎﺭ ﺑﺠﻮﺍﺭ ﺍﻟﺨﻴﺎﺭ .ﺇﺫﺍ ﻟﻢ ﻳﻨﺠﺢ ﺍﻟﺨﻴﺎﺭ ،ﻓﺴﻴﺘﻢ ﻋﺮﺽ ﻣﺮﺑﻊ ﺃﺣﻤﺮ ﺑﻪ ﻋﻼﻣﺔ "."X
ﺃﺯﺭﺍﺭ
ﺍﻟﻌﻨﺎﺻﺮﺍﻟﻤﺬﻛﻮﺭﺓ ﺃﺩﻧﺎﻩ ﻫﻲ ﺃﻭﺻﺎﻑ ﻛﻞ ﺯﺭ .ﺍﻧﻘﺮ ﻋﻠﻰ ﻋﻨﺼﺮ ﻟﻤﺰﻳﺪ ﻣﻦ ﺍﻟﻤﻌﻠﻮﻣﺎﺕ.
ﻳﺘﺼﻞ
ﻳﻮﺟﺪﻣﺎ ﻳﺼﻞ ﺇﻟﻰ ﺻﻮﺭﺗﻲ ﻓﻼﺵ ﻳﻤﻜﻦ ﺗﺨﺰﻳﻨﻬﻤﺎ ﻓﻲ ﻟﻮﺣﺔ ﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ .OMNI 68-6201ﺇﺫﺍ ﻛﺎﻧﺖ ﻫﻨﺎﻙ ﺻﻮﺭﺓ ﻣﺨﺰﻧﺔ ﺑﺎﻟﻔﻌﻞ ،ﻓﺴﻴﺘﻢ ﻋﺮﺽ
ﺇﺻﺪﺍﺭﺻﻮﺭﺓ ﺍﻟﻔﻼﺵ .ﺑﻌﺪ ﺗﺤﺪﻳﺪ ﻣﻠﻒ ﻓﻼﺵ ،ﻳﺘﻢ ﺗﻤﻜﻴﻦ ﺗﺤﺪﻳﺪ ﺻﻮﺭﺓ ﺍﻟﻔﻼﺵ .ﺣﺪﺩ ﻣﻨﻄﻘﺔ ﺍﻟﺼﻮﺭﺓ ) 1ﺃﻭ (2ﺍﻟﺘﻲ ﺗﺮﻏﺐ ﻓﻲ ﺇﺭﺳﺎﻝ ﻣﻠﻒ ﺍﻟﻔﻼﺵ ﺇﻟﻴﻬﺎ.
ﺗﺄﻛﺪﺃﻭﻻ ًﻣﻦ ﺗﻮﺻﻴﻞ ﺍﻟﻜﺎﺑﻼﺕ ﺍﻟﻤﻨﺎﺳﺒﺔ ﻓﻌﻠﻴﺎً ﻗﺒﻞ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "ﺍﻻﺗﺼﺎﻝ" .ﺗﺘﻢ ﻣﺤﺎﻭﻟﺔ ﺍﻻﺗﺼﺎﻝ ﺑﺎﻟﻮﺣﺪﺓ ﻋﻨﺪ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "ﺍﻻﺗﺼﺎﻝ".ﻣﻼﺣﻈﺔ :ﺑﺎﻟﻨﺴﺒﺔ
ﻷﻫﺪﺍﻑ" "OMNI 7201ﻭ" ،"OMNI 68-6201ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ OMNIﻓﻲ ﻭﺿﻊ " "BootLoaderﻗﺒﻞ ﺇﺟﺮﺍء ﺍﻻﺗﺼﺎﻝ.
ﻓﻲﺣﺎﻟﺔ ) :(OMNI 7201ﺍﺿﺒﻂ ﻣﻔﺘﺎﺡ "ﻗﻔﻞ ﺍﻟﺒﺮﻧﺎﻣﺞ" ﺑﺎﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﻋﻠﻰ ﻭﺿﻊ "ﺗﻤﻜﻴﻦ ﺍﻟﺒﺮﻧﺎﻣﺞ" ،ﻭﺍﺿﻐﻂ ﻣﻊ ﺍﻻﺳﺘﻤﺮﺍﺭ ﻋﻠﻰ ﺍﻟﺰﺭ "ﺃﻗﺼﻰ ﺍﻟﻴﺴﺎﺭ ﺑﺎﻟﻠﻮﻥ
ﺍﻷﺣﻤﺮ" ﺃﺛﻨﺎء ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﻣﻔﺘﺎﺡ "ﺇﻋﺎﺩﺓ ﺍﻟﻀﺒﻂ" ﺍﻟﻤﻮﺟﻮﺩ ﺧﻠﻒ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﻟـ OMNIﻓﻲ ﺃﻋﻠﻰ ﺍﻟﻴﻤﻴﻦ .ﺳﺘﻌﺮﺽ ﺍﻟﺸﺎﺷﺔ "ﻗﺎﺉﻤﺔ ﺧﻴﺎﺭﺍﺕ ﺍﻟﺘﻤﻬﻴﺪ" .ﻗﻢ
ﺑﺎﻟﺘﻤﺮﻳﺮﻷﺳﻔﻞ ﺣﺘﻰ ﺗﻜﻮﻥ ﺍﻷﻗﻮﺍﺱ ﺣﻮﻝ ﺍﻟﻜﻠﻤﺎﺕ " "Enter BootLoaderﺛﻢ ﺍﺿﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "."Enter
ﻓﻲﺣﺎﻟﺔ ) :(OMNI 68-6201ﺍﺿﺒﻂ ﻣﻔﺘﺎﺡ ﻗﻔﻞ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﻋﻠﻰ ﻭﺿﻊ "ﺇﻳﻘﺎﻑ ﺍﻟﺘﺸﻐﻴﻞ" ،ﻭﺍﺿﻐﻂ ﻣﻊ ﺍﻻﺳﺘﻤﺮﺍﺭ ﻋﻠﻰ ﺍﻟﺰﺭ " "Progﺃﺛﻨﺎء ﺍﻟﻀﻐﻂ ﻋﻠﻰ
ﻣﻔﺘﺎﺡ" "Resetﺍﻟﻤﻮﺟﻮﺩ ﺧﻠﻒ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﻟـ OMNIﻓﻲ ﺃﻋﻠﻰ ﺍﻟﻴﻤﻴﻦ .ﺳﺘﻌﺮﺽ ﺍﻟﺸﺎﺷﺔ "ﻗﺎﺉﻤﺔ ﺧﻴﺎﺭﺍﺕ ﺍﻟﺘﻤﻬﻴﺪ" .ﻗﻢ ﺑﺎﻟﺘﻤﺮﻳﺮ ﻷﺳﻔﻞ ﺣﺘﻰ ﺗﻜﻮﻥ
ﺍﻷﻗﻮﺍﺱﺣﻮﻝ ﺍﻟﻜﻠﻤﺎﺕ " "Enter BootLoaderﺛﻢ ﺍﺿﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "."Enter
ﻣﻼﺣﻈﺔ:ﺃﻣﺎﻣﻚ ﺧﻤﺲ ﺛﻮﺍﻥ ٍﺑﻌﺪ ﺇﻋﺎﺩﺓ ﺍﻟﺘﻌﻴﻴﻦ ﻟﺒﺪء ﺍﻟﺘﻤﺮﻳﺮ ﻭﺇﻻ ﺳﻴﺘﻌﻴﻦ ﺗﻜﺮﺍﺭ ﺇﺟﺮﺍء ﺇﻋﺎﺩﺓ ﺍﻟﺘﻌﻴﻴﻦ.
ﺗﺘﻢﺍﻹﺷﺎﺭﺓ ﺇﻟﻰ ﺍﻻﺗﺼﺎﻝ ﺍﻟﻨﺎﺟﺢ ﻣﻦ ﺧﻼﻝ ﺭﺳﺎﻟﺔ ﺣﺎﻟﺔ ﺃﻋﻠﻰ ﻗﺴﻢ ﻣﻠﻒ Flashﻭﻣﻦ ﺧﻼﻝ ﺗﻤﻜﻴﻦ ﺯﺭ ﺗﺤﺪﻳﺪ ﻣﻠﻒ Flashﻭﺧﻴﺎﺭﺍﺕ ﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ .ﻳﺘﻐﻴﺮ
ﻧﺺﺯﺭ "ﺍﻻﺗﺼﺎﻝ" ﺇﻟﻰ "ﺍﺑﺪﺃ".
ﻳﺨﺘﺎﺭ
ﺍﻧﻘﺮﻓﻮﻕ ﺍﻟﺰﺭ "ﺗﺤﺪﻳﺪ" ﻻﺧﺘﻴﺎﺭ ﻣﻠﻒ ﺍﻟﻔﻼﺵ ﻹﺭﺳﺎﻟﻪ ﺇﻟﻰ ﺍﻟﻬﺪﻑ .ﻳﻈﻬﺮ ﻣﺮﺑﻊ ﺣﻮﺍﺭ "ﻓﺘﺢ ﻣﻠﻒ" ﻗﻴﺎﺳﻲ ﻟﻠﺴﻤﺎﺡ ﻟﻚ ﺑﺎﻟﺘﺼﻔﺢ ﺑﺤﺜﺎً ﻋﻦ ﻣﻠﻒ ﻓﻼﺵ ﺑﺎﻣﺘﺪﺍﺩ ""bin.
.ﻟﺘﺤﺪﻳﺪ ﻣﻠﻒ ،ﺍﻧﻘﺮ ﻓﻮﻕ ﺍﻟﻤﻠﻒ ﺛﻢ ﺍﺿﻐﻂ ﻋﻠﻰ "ﻓﺘﺢ".ﻣﻠﺤﻮﻇﺔ :ﺑﺎﻟﻨﺴﺒﺔ ﻟﻜﻞ ﻣﻦ ﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ " "OMNI 7201ﻭ" ،"OMNI 68- 6201ﻳﺘﻢ ﺗﻮﻓﻴﺮ
ﻣﻠﻒﻓﻼﺵ ﺑﻮﺍﺳﻄﺔ OMNIﻭﺍﻟﺬﻱ ﻳﺠﺐ ﺗﺮﺧﻴﺼﻪ ﻟﻠﺮﻗﻢ ﺍﻟﺘﺴﻠﺴﻠﻲ ﻟﻮﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ ﻟﻠﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ.
ﻋﻨﺪﺗﺤﺪﻳﺪ ﻣﻠﻒ ﺻﺎﻟﺢ ،ﻳﺘﻢ ﻋﺮﺽ ﺍﺳﻢ ﺍﻟﻤﻠﻒ ﺍﻟﻤﺤﺪﺩ ﻭﺍﻟﻤﺴﺎﺭ ﻓﻲ ﻗﺴﻢ "ﻣﻠﻒ ﺍﻟﻔﻼﺵ" ﻭﻳﺘﻢ ﺗﻤﻜﻴﻦ ﺧﻴﺎﺭﺍﺕ ﺍﻟﻔﻼﺵ.
ﻳﺒﺪﺃ
ﻳﺘﻢﺗﻤﻜﻴﻦ ﺍﻟﺰﺭ "ﺍﺑﺪﺃ" ﺑﻌﺪ ﺗﺤﺪﻳﺪ ﻣﻠﻒ ﻓﻼﺵ ،ﺃﻭ ﺗﺤﺪﻳﺪ ﺧﻴﺎﺭ ﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ ) ،(RAMﺃﻭ ﺗﻐﻴﻴﺮ ﺗﺤﺪﻳﺪ ﺻﻮﺭﺓ ﺍﻟﺘﻤﻬﻴﺪ .ﺍﺿﻐﻂ ﻋﻠﻰ ﺯﺭ "ﺍﺑﺪﺃ" ﻟﺒﺪء
ﺍﻟﻌﻤﻠﻴﺎﺕﺍﻟﻤﺤﺪﺩﺓ .ﻳﺘﻢ ﻋﺮﺽ ﺭﺳﺎﻟﺔ ﺣﺎﻟﺔ ﻣﻊ ﺷﺮﻳﻂ ﺍﻟﺘﻘﺪﻡ ﻹﻇﻬﺎﺭ ﻣﺪﻯ ﺗﻘﺪﻡ ﺍﻟﻌﻤﻠﻴﺎﺕ ﺍﻟﺘﻲ ﻳﺘﻢ ﺗﻨﻔﻴﺬﻫﺎ.
ﺇﺣﺒﺎﻁ
ﻳﻤﻜﻦﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ "ﺇﺣﺒﺎﻁ" ﻓﻲ ﺃﻱ ﻭﻗﺖ ﺑﻌﺪ ﺑﺪء ﺗﺸﻐﻴﻞ ﺍﻟﻔﻼﺵ ﺣﺘﻰ ﺍﻛﺘﻤﺎﻟﻪ .ﺇﺫﺍ ﺗﻢ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ ،ﺗﻈﻬﺮ ﺭﺳﺎﻟﺔ ﺗﺴﺄﻟﻚ ﻋﻤﺎ ﺇﺫﺍ ﻛﻨﺖ ﺗﺮﻳﺪ ﺇﻟﻐﺎء ﻫﺬﻩ
ﺍﻟﻌﻤﻠﻴﺔ.ﺇﺫﺍ ﻗﻤﺖ ﺑﺘﺤﺪﻳﺪ "ﻧﻌﻢ" ،ﻳﺘﻮﻗﻒ ﺍﻟﻮﻣﻴﺾ ﻭﺗﻈﻬﺮ ﻋﻼﻣﺔ " "Xﺣﻤﺮﺍء ﺑﺠﻮﺍﺭ ﺍﻟﻮﻇﻴﻔﺔ ﺍﻟﺘﻲ ﻳﺘﻢ ﺗﻨﻔﻴﺬﻫﺎ .ﺇﺫﺍ ﻗﻤﺖ ﺑﺘﺤﺪﻳﺪ "ﻻ" ،ﻓﺴﺘﺴﺘﻤﺮ ﺍﻟﻌﻤﻠﻴﺔ ﻣﻦ ﺣﻴﺚ
ﺗﻮﻗﻔﺖ.
ﻣﺨﺮﺝ
ﻋﻤﻠﻴﺔ
ﺣﺪﺩﺃﻭﻻ ًﻭﺣﺪﺓ ﺍﻟﻬﺪﻑ ﺃﻭ ﻧﻮﻉ ﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ .ﺍﻧﻘﺮ ﻓﻮﻕ ﻧﻮﻉ ﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ ﻟﻠﺤﺼﻮﻝ ﻋﻠﻰ ﺗﻌﻠﻴﻤﺎﺕ ﺧﺎﺻﺔ ﺑﻮﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ ﻫﺬﻩ.
ﺃﻭﻣﻨﻲ7201
ﺇﺫﺍﻛﻨﺖ ﺳﺘﻘﻮﻡ ﺑﺘﺤﻤﻴﻞ ﻣﻠﻒ ﻓﻼﺵ ﺇﻟﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ ،ﻓﺘﺄﻛﺪ ﻣﻦ ﺃﻥ ﻭﺻﻠﺔ " ،Flash Update"، J2ﻓﻲ ﺍﻟﻮﺿﻊ "ﻣﻤﻜﻦّ" ﻋﻠﻰ ﻟﻮﺣﺔ ﻭﺣﺪﺓ
ﺍﻟﻤﻌﺎﻟﺠﺔﺍﻟﻤﺮﻛﺰﻳﺔ OMNI 7201ﻗﺒﻞ ﺍﻟﺒﺪء.
ﻗﻢﺑﺘﻮﺻﻴﻞ ﻛﺒﻞ USBﻣﻦ ﻣﻨﻔﺬ mini-Bﺍﻟﻤﻮﺟﻮﺩ ﻋﻠﻰ ﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ OMNI 7201ﺑﻤﻨﻔﺬ USBﻗﻴﺎﺳﻲ ﻋﻠﻰ ﺟﻬﺎﺯ ﺍﻟﻜﻤﺒﻴﻮﺗﺮ ﺍﻟﺨﺎﺹ ﺑﻚ.
ﻣﻼﺣﻈﺔ:ﻳﺠﺐ ﺗﺜﺒﻴﺖ ﺑﺮﺍﻣﺞ ﺗﺸﻐﻴﻞ USBﻗﺒﻞ ﺇﻧﺸﺎء ﺍﺗﺼﺎﻝ ﻧﺎﺟﺢ .ﺭﺍﺟﻊ ﻣﺠﻠﺪ "ﺑﺮﺍﻣﺞ ﺗﺸﻐﻴﻞ "USBﺍﻟﻤﻮﺟﻮﺩ ﻓﻲ ﻣﺠﻠﺪ ﺗﺜﺒﻴﺖ SmartFlash
ﻟﻠﺤﺼﻮﻝﻋﻠﻰ ﻣﺰﻳﺪ ﻣﻦ ﺍﻟﻤﻌﻠﻮﻣﺎﺕ.
ﻳﺠﺐﺃﻥ ﻳﻜﻮﻥ OMNIﻓﻲ ﻭﺿﻊ " "BootLoaderﻗﺒﻞ ﺇﺟﺮﺍء ﺍﻻﺗﺼﺎﻝ .ﻟﻠﺪﺧﻮﻝ ﺇﻟﻰ ﻭﺿﻊ ،BootLoaderﺍﺿﺒﻂ ﻣﻔﺘﺎﺡ ﻗﻔﻞ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﻋﻠﻰ ﻭﺿﻊ "
ﺗﻤﻜﻴﻦﺍﻟﺒﺮﻧﺎﻣﺞ" ،ﺛﻢ ﺍﺿﻐﻂ ﻣﻊ ﺍﻻﺳﺘﻤﺮﺍﺭ ﻋﻠﻰ ﺍﻟﺰﺭ " "Left Most Redﺃﺛﻨﺎء ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﻣﻔﺘﺎﺡ " "Resetﺍﻟﻤﻮﺟﻮﺩ ﺧﻠﻒ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﻟـ OMNIﻓﻲ
ﺃﻋﻠﻰﺍﻟﻴﻤﻴﻦ .ﺳﺘﻌﺮﺽ ﺍﻟﺸﺎﺷﺔ "ﻗﺎﺉﻤﺔ ﺧﻴﺎﺭﺍﺕ ﺍﻟﺘﻤﻬﻴﺪ" .ﻗﻢ ﺑﺎﻟﺘﻤﺮﻳﺮ ﻷﺳﻔﻞ ﺣﺘﻰ ﺗﻜﻮﻥ ﺍﻷﻗﻮﺍﺱ ﺣﻮﻝ ﺍﻟﻜﻠﻤﺎﺕ " "Enter Flash Modeﺛﻢ ﺍﺿﻐﻂ ﻋﻠﻰ
ﺍﻟﺰﺭ"."Enterﻣﻼﺣﻈﺔ :ﺃﻣﺎﻣﻚ ﺧﻤﺲ ﺛﻮﺍﻥ ٍﺑﻌﺪ ﺇﻋﺎﺩﺓ ﺍﻟﺘﻌﻴﻴﻦ ﻟﺒﺪء ﺍﻟﺘﻤﺮﻳﺮ ﻭﺇﻻ ﺳﻴﺘﻌﻴﻦ ﺗﻜﺮﺍﺭ ﺇﺟﺮﺍء ﺇﻋﺎﺩﺓ ﺍﻟﺘﻌﻴﻴﻦ.
ﺍﺿﻐﻂﻋﻠﻰ ﺯﺭ "ﺍﻻﺗﺼﺎﻝ".
ﻋﻨﺪﻧﺠﺎﺡ ﺍﻻﺗﺼﺎﻝ ،ﺗﻈﻬﺮ ﺭﺳﺎﻟﺔ ﺃﻋﻠﻰ ﻗﺴﻢ "ﻣﻠﻒ ﺍﻟﻔﻼﺵ" ﻣﺸﺎﺑﻬﺔ ﻟﻤﺎ ﻳﻠﻲ:
ﻣﺘﺼﻞ:ﻣﻨﻔﺬ USBﻣﺤﻠﻲ ﺇﻟﻰ ﻣﻨﻔﺬ [ OMNI USB ]SN: 01234A7201ﻳﻌﺮﺽ
ﻗﺴﻢ"ﺣﺎﻟﺔ ﺍﻟﺼﻮﺭﺓ" ﺍﻹﺻﺪﺍﺭﺍﺕ ﺍﻟﺤﺎﻟﻴﺔ ﻣﻦ ﺻﻮﺭ ﺍﻟﻔﻼﺵ .ﺗﻢ ﺗﻤﻜﻴﻦ ﻗﺴﻢ "ﺧﻴﺎﺭﺍﺕ ﺫﺍﻛﺮﺓ
ﺍﻟﻮﺻﻮﻝﺍﻟﻌﺸﻮﺍﺉﻲ".
ﺇﺫﺍﻛﻨﺖ ﺗﺮﻏﺐ ﻓﻲ ﺗﺤﻤﻴﻞ ﻣﻠﻒ ﻓﻼﺵ ﺇﻟﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ:
ﺍﺿﻐﻂﻋﻠﻰ ﺍﻟﺰﺭ "ﺗﺤﺪﻳﺪ" ﻻﺧﺘﻴﺎﺭ ﻣﻠﻒ ﺍﻟﻔﻼﺵ ﺑﺎﻣﺘﺪﺍﺩ " "bin.ﺍﻟﺬﻱ ﺗﻢ ﺗﻮﻓﻴﺮﻩ ﺑﻮﺍﺳﻄﺔ OMNIﺍﻟﻤﺮﺧﺺ ﻟﻠﺮﻗﻢ ﺍﻟﺘﺴﻠﺴﻠﻲ ﻟﻮﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ
ﺍﻟﻤﺮﻛﺰﻳﺔﻟﻠﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ.
ﻓﻲﻣﺮﺑﻊ ﺍﻟﺤﻮﺍﺭ "ﻓﺘﺢ" ،ﺣﺪﺩ ﻣﻮﻗﻊ ﺍﻟﻤﻠﻒ ﻭﺣﺪﺩﻩ ﺛﻢ ﺍﺿﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "ﻓﺘﺢ".
ﺇﺫﺍﻟﻢ ﻳﻜﻦ ﺍﻟﻤﻠﻒ ﻣﺮﺧﺼﺎً ،ﻓﺴﻴﺘﻢ ﻋﺮﺽ ﺭﺳﺎﻟﺔ ﻭﻟﻦ ﺗﺘﻢ ﻣﺘﺎﺑﻌﺔ ﺗﺤﻤﻴﻞ ﺍﻟﻔﻼﺵ.
ﺇﺫﺍﻛﺎﻥ ﺍﻟﻤﻠﻒ ﺻﺎﻟﺤﺎً ،ﻓﺴﻴﺘﻢ ﻋﺮﺽ ﺍﺳﻢ ﺍﻟﻤﻠﻒ ﺍﻟﻤﺤﺪﺩ ﻣﻊ ﺍﻟﻤﺴﺎﺭ ﻓﻲ ﻗﺴﻢ "ﻣﻠﻒ ﻓﻼﺵ" ﻭﻳﺘﻢ ﻋﺮﺽ ﻣﻌﻠﻮﻣﺎﺕ "ﻣﺮﺧﺺ ﻟـ" ﺃﺳﻔﻠﻪ.
ﺃﻭﻣﻨﻲ6201-68
ﺇﺫﺍﻛﻨﺖ ﺳﺘﻘﻮﻡ ﺑﺘﺤﻤﻴﻞ ﻣﻠﻒ ﻓﻼﺵ ﺇﻟﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ ،ﻓﺘﺄﻛﺪ ﻣﻦ ﺃﻥ ﻭﺻﻠﺔ " ،Flash Update"، J5ﻓﻲ ﺍﻟﻮﺿﻊ "ﻣﻤﻜﻦّ" ﻋﻠﻰ ﻟﻮﺣﺔ ﻭﺣﺪﺓ
ﺍﻟﻤﻌﺎﻟﺠﺔﺍﻟﻤﺮﻛﺰﻳﺔ OMNI 68-6201ﻗﺒﻞ ﺍﻟﺒﺪء.
ﻗﻢﺑﺘﻮﺻﻴﻞ ﻛﺒﻞ USBﻣﻦ ﻣﻨﻔﺬ mini-Bﺍﻟﻤﻮﺟﻮﺩ ﻋﻠﻰ ﻭﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ OMNI 68-6201ﺑﻤﻨﻔﺬ USBﻗﻴﺎﺳﻲ ﻋﻠﻰ ﺟﻬﺎﺯ ﺍﻟﻜﻤﺒﻴﻮﺗﺮ ﺍﻟﺨﺎﺹ ﺑﻚ.
ﻣﻼﺣﻈﺔ:ﻳﺠﺐ ﺗﺜﺒﻴﺖ ﺑﺮﺍﻣﺞ ﺗﺸﻐﻴﻞ USBﻗﺒﻞ ﺇﻧﺸﺎء ﺍﺗﺼﺎﻝ ﻧﺎﺟﺢ .ﺭﺍﺟﻊ ﻣﺠﻠﺪ "ﺑﺮﺍﻣﺞ ﺗﺸﻐﻴﻞ "USBﺍﻟﻤﻮﺟﻮﺩ ﻓﻲ ﻣﺠﻠﺪ ﺗﺜﺒﻴﺖ SmartFlash
ﻟﻠﺤﺼﻮﻝﻋﻠﻰ ﻣﺰﻳﺪ ﻣﻦ ﺍﻟﻤﻌﻠﻮﻣﺎﺕ.
ﻳﺠﺐﺃﻥ ﻳﻜﻮﻥ OMNIﻓﻲ ﻭﺿﻊ " "BootLoaderﻗﺒﻞ ﺇﺟﺮﺍء ﺍﻻﺗﺼﺎﻝ .ﻟﻠﺪﺧﻮﻝ ﺇﻟﻰ ﻭﺿﻊ ،BootLoaderﺍﺿﺒﻂ ﻣﻔﺘﺎﺡ ﻗﻔﻞ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﻋﻠﻰ ﻭﺿﻊ "
ﺗﻤﻜﻴﻦﺍﻟﺒﺮﻧﺎﻣﺞ" ،ﺛﻢ ﺍﺿﻐﻂ ﻣﻊ ﺍﻻﺳﺘﻤﺮﺍﺭ ﻋﻠﻰ ﺯﺭ " "Progﺃﺛﻨﺎء ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﻣﻔﺘﺎﺡ "ﺇﻋﺎﺩﺓ ﺍﻟﻀﺒﻂ" ﺍﻟﻤﻮﺟﻮﺩ ﺧﻠﻒ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﻟـ OMNIﻓﻲ ﺃﻋﻠﻰ
ﺍﻟﻴﻤﻴﻦ.ﺳﺘﻌﺮﺽ ﺍﻟﺸﺎﺷﺔ "ﻗﺎﺉﻤﺔ ﺧﻴﺎﺭﺍﺕ ﺍﻟﺘﻤﻬﻴﺪ" .ﻗﻢ ﺑﺎﻟﺘﻤﺮﻳﺮ ﻷﺳﻔﻞ ﺣﺘﻰ ﺗﻜﻮﻥ ﺍﻷﻗﻮﺍﺱ ﺣﻮﻝ ﺍﻟﻜﻠﻤﺎﺕ " "Enter BootLoaderﺛﻢ ﺍﺿﻐﻂ ﻋﻠﻰ
ﺍﻟﺰﺭ"."Enterﻣﻼﺣﻈﺔ :ﺃﻣﺎﻣﻚ ﺧﻤﺲ ﺛﻮﺍﻥ ٍﺑﻌﺪ ﺇﻋﺎﺩﺓ ﺍﻟﺘﻌﻴﻴﻦ ﻟﺒﺪء ﺍﻟﺘﻤﺮﻳﺮ ﻭﺇﻻ ﺳﻴﺘﻌﻴﻦ ﺗﻜﺮﺍﺭ ﺇﺟﺮﺍء ﺇﻋﺎﺩﺓ ﺍﻟﺘﻌﻴﻴﻦ.
ﺍﺿﻐﻂﻋﻠﻰ ﺯﺭ "ﺍﻻﺗﺼﺎﻝ".
ﻋﻨﺪﻧﺠﺎﺡ ﺍﻻﺗﺼﺎﻝ ،ﺗﻈﻬﺮ ﺭﺳﺎﻟﺔ ﺃﻋﻠﻰ ﻗﺴﻢ "ﻣﻠﻒ ﺍﻟﻔﻼﺵ" ﻣﺸﺎﺑﻬﺔ ﻟﻤﺎ ﻳﻠﻲ:
ﻣﺘﺼﻞ:ﻣﻨﻔﺬ USBﻣﺤﻠﻲ ﺇﻟﻰ ﻣﻨﻔﺬ [ OMNI USB ]SN: 01234-567Aﻳﻌﺮﺽ
ﻗﺴﻢ"ﺻﻮﺭﺓ ﺍﻟﻔﻼﺵ" ﺍﻹﺻﺪﺍﺭﺍﺕ ﺍﻟﺤﺎﻟﻴﺔ ﻣﻦ ﺻﻮﺭ ﺍﻟﻔﻼﺵ .ﺗﻢ ﺗﻤﻜﻴﻦ ﻗﺴﻤﻲ "ﺻﻮﺭﺓ
ﺍﻟﺘﻤﻬﻴﺪ" ﻭ"ﺧﻴﺎﺭﺍﺕ ﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ".
ﺣﺪﺩﺻﻮﺭﺓ ﺍﻟﺘﻤﻬﻴﺪ ﺍﻻﻓﺘﺮﺍﺿﻴﺔ ) 1ﺃﻭ .(2ﺣﺪﺩ ﺧﻴﺎﺭﺍﺕ
ﺫﺍﻛﺮﺓﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ ) (RAMﺍﻟﻤﻄﻠﻮﺑﺔ.
ﺇﺫﺍﻛﻨﺖ ﺗﺮﻏﺐ ﻓﻲ ﺗﺤﻤﻴﻞ ﻣﻠﻒ ﻓﻼﺵ ﺇﻟﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ:
ﺍﺿﻐﻂﻋﻠﻰ ﺍﻟﺰﺭ "ﺗﺤﺪﻳﺪ" ﻻﺧﺘﻴﺎﺭ ﻣﻠﻒ ﺍﻟﻔﻼﺵ ﺑﺎﻣﺘﺪﺍﺩ " "bin.ﺍﻟﺬﻱ ﺗﻢ ﺗﻮﻓﻴﺮﻩ ﺑﻮﺍﺳﻄﺔ OMNIﺍﻟﻤﺮﺧﺺ ﻟﻠﺮﻗﻢ ﺍﻟﺘﺴﻠﺴﻠﻲ ﻟﻮﺣﺪﺓ ﺍﻟﻤﻌﺎﻟﺠﺔ
ﺍﻟﻤﺮﻛﺰﻳﺔﻟﻠﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ.
ﻓﻲﻣﺮﺑﻊ ﺍﻟﺤﻮﺍﺭ "ﻓﺘﺢ" ،ﺣﺪﺩ ﻣﻮﻗﻊ ﺍﻟﻤﻠﻒ ﻭﺣﺪﺩﻩ ﺛﻢ ﺍﺿﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "ﻓﺘﺢ".
ﺇﺫﺍﻟﻢ ﻳﻜﻦ ﺍﻟﻤﻠﻒ ﻣﺮﺧﺼﺎً ،ﻓﺴﻴﺘﻢ ﻋﺮﺽ ﺭﺳﺎﻟﺔ ﻭﻟﻦ ﺗﺘﻢ ﻣﺘﺎﺑﻌﺔ ﺗﺤﻤﻴﻞ ﺍﻟﻔﻼﺵ.
ﺇﺫﺍﻛﺎﻥ ﺍﻟﻤﻠﻒ ﺻﺎﻟﺤﺎً ،ﻓﺴﻴﺘﻢ ﻋﺮﺽ ﺍﺳﻢ ﺍﻟﻤﻠﻒ ﺍﻟﻤﺤﺪﺩ ﻣﻊ ﺍﻟﻤﺴﺎﺭ ﻓﻲ ﻗﺴﻢ "ﻣﻠﻒ ﻓﻼﺵ" ﻭﻳﺘﻢ ﻋﺮﺽ ﻣﻌﻠﻮﻣﺎﺕ "ﻣﺮﺧﺺ ﻟـ" ﺃﺳﻔﻠﻪ.
ﺍﻟﺤﺎﻓﻠﺔﺍﻟﺬﻛﻴﺔ )(LMC/RMC
ﻗﻢﺑﺘﻮﺻﻴﻞ ﻛﺒﻞ ﺗﺴﻠﺴﻠﻲ ﺑﺄﻱ ﻣﻨﻔﺬ ﺗﺴﻠﺴﻠﻲ ﻋﻠﻰ LMC/RMCﻭﺑﻤﻨﻔﺬ ﺗﺴﻠﺴﻠﻲ ﻋﻠﻰ ﺟﻬﺎﺯ ﺍﻟﻜﻤﺒﻴﻮﺗﺮ ﺍﻟﺨﺎﺹ
ﺑﻚ.ﺍﺿﻐﻂ ﻋﻠﻰ ﺯﺭ "ﺍﻻﺗﺼﺎﻝ".
ﺗﻈﻬﺮﺍﻟﺮﺳﺎﻟﺔ "ﻓﻲ ﺍﻧﺘﻈﺎﺭ ﺇﻋﺎﺩﺓ ﺗﻌﻴﻴﻦ ﺃﺩﺍﺓ ﺗﺤﻤﻴﻞ ﺍﻟﺘﻤﻬﻴﺪ" ﻣﻊ ﺷﺮﻳﻂ ﺍﻟﺘﻘﺪﻡ ﻹﻇﻬﺎﺭ ﺣﺎﻟﺔ ﺇﻋﺎﺩﺓ ﺍﻟﺘﻌﻴﻴﻦ .ﻋﻨﺪ ﻧﺠﺎﺡ ﺍﻻﺗﺼﺎﻝ،
ﺗﻈﻬﺮﺭﺳﺎﻟﺔ ﺃﻋﻠﻰ ﻗﺴﻢ "ﻣﻠﻒ ﺍﻟﻔﻼﺵ" ﻣﺸﺎﺑﻬﺔ ﻟﻤﺎ ﻳﻠﻲ:
"ﻣﺘﺼﻞ :COM1 :ﺇﻟﻰ ﻣﻨﻔﺬ RMCﺍﻟﺘﺴﻠﺴﻠﻲ ."2ﺗﻢ ﺗﻤﻜﻴﻦ
ﻗﺴﻢ"ﺧﻴﺎﺭﺍﺕ ﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻌﺸﻮﺍﺉﻲ" .ﺣﺪﺩ ﺧﻴﺎﺭﺍﺕ ﺫﺍﻛﺮﺓ ﺍﻟﻮﺻﻮﻝ
ﺍﻟﻌﺸﻮﺍﺉﻲ) (RAMﺍﻟﻤﻄﻠﻮﺑﺔ.
ﺇﺫﺍﻛﻨﺖ ﺗﺮﻏﺐ ﻓﻲ ﺗﺤﻤﻴﻞ ﻣﻠﻒ ﻓﻼﺵ ﺇﻟﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ:
ﺍﺿﻐﻂﻋﻠﻰ ﺍﻟﺰﺭ "ﺗﺤﺪﻳﺪ" ﻻﺧﺘﻴﺎﺭ ﻣﻠﻒ ﺍﻟﻔﻼﺵ ﺑﺎﻣﺘﺪﺍﺩ " ."bin.ﻓﻲ ﻣﺮﺑﻊ ﺍﻟﺤﻮﺍﺭ "ﻓﺘﺢ"،
ﺣﺪﺩﻣﻮﻗﻊ ﺍﻟﻤﻠﻒ ﻭﺣﺪﺩﻩ ﺛﻢ ﺍﺿﻐﻂ ﻋﻠﻰ ﺍﻟﺰﺭ "ﻓﺘﺢ" .ﻳﺘﻢ ﻋﺮﺽ ﺍﺳﻢ ﺍﻟﻤﻠﻒ ﺍﻟﻤﺤﺪﺩ ﻣﻊ
ﺍﻟﻤﺴﺎﺭﻓﻲ ﻗﺴﻢ "ﻣﻠﻒ ﺍﻟﻔﻼﺵ" .ﻳﺘﻢ ﺑﻌﺪ ﺫﻟﻚ ﺗﻤﻜﻴﻦ "ﺧﻴﺎﺭﺍﺕ ﺍﻟﻔﻼﺵ".
ﺍﻧﻘﺮﻋﻠﻰ ﺍﻟﺮﺍﺑﻂ ﺍﻟﺘﺎﻟﻲ ﻭﺍﻧﺘﻘﻞ ﺇﻟﻰ ﺻﻔﺤﺔ ﺍﻟﺘﻨﺰﻳﻞ ﻟﻠﺤﺼﻮﻝ ﻋﻠﻰ ﺍﻟﺘﺤﺪﻳﺜﺎﺕ.
www.omniflow.com
ﺗﻌﻠﻴﻤﺎﺕ/ﺣﻮﻝ ﺍﻟﺼﻨﺪﻭﻕ
ﺍﺳﺘﺨﺪﻡﻫﺬﻩ ﺍﻟﻤﻴﺰﺓ ﻟﻌﺮﺽ ﺇﺷﻌﺎﺭ ﺣﻘﻮﻕ ﺍﻟﻄﺒﻊ ﻭﺍﻟﻨﺸﺮ ﻭﺭﻗﻢ ﺇﺻﺪﺍﺭ ﻧﺴﺨﺘﻚ ﻣﻦ ﺍﻟﺒﺮﻧﺎﻣﺞ.