4. Multi-Language Settings
Add “English”, “Traditional Chinese” and “Simplified Chinese” three languages. The setting value are 0,1
and 2 for each language respectively.
z Double click the Traditional Chinese tab and enter “ 警示燈 ” in Traditional Chinese.
z Double click the “Simplified Chinese” and enter “ 警示燈” in Simplified Chinese”
6. In property setting of “Increment” button element, please set the write address as the internal memory
$207.
7. Then, set the setting value of “Before Execute Macro”. The users can enter the Macro command as
$207=$207%3.
8. Select Compile command and execute Off Line Simulation. Then, the users can see the text of the
“Set” button is changed in different language by pressing the “Increment” button element.
Alarm Setup
The users can set alarm by clicking Options > Alarm Setup (Fig.
2.9.3). The alarm setup should set with the alarm function in element
settings. HMI will execute alarm function automatically if both settings
are all set. When the specified conditions are matched (If condition
occurs in specific address, ON enabled or OFF enabled) after setting,
HMI will display a Alarm Setup warning dialog box automatically. In this
dialog box (Fig. 2.9.4), there are Delete, Modify, Import, Export and
Close for the users to use. For more information for the settings of
Alarm Setup, please refer to the Table 2.9.6 on the following page and
Chapter 3 for more description.
The following Alarm Property Setup dialog box will display after double
clicking the row.
Moving points It is used to set the moving points every time for the alarm moving sign.
The unit is Pixel and the range is within 1 ~ 50 points.
Interval (ms) It is used to set the interval time every time for the alarm moving sign.
The unit is ms and the range is within 50 ~ 3000 ms.
Background It is used to set the background color of the alarm moving sign.
Color
History Setup
Read Address It is used to set the starting address for sampling the history data.
Data Length It is used to set how much Word the users want to sample? The range is
(Word) within 1 ~ 13 continuous Words. It indicates that max. 13 continuous words
can be sampled.
Cycle (ms) It is used to set the sampling cycle time for reading address (how long is it to
read address one time). If the Trigger option is PLC, this option will be
ineffective. The range of the sampling cycle time is within 0 ~ 86400000 ms.
Sample Number This option is used with the Auto Stop option. If the Auto Stop option is
selected, HMI will stop recording the data after the numbers of records have
reached the setting value of Sample Number option. If the Auto Stop option
is not selected, when record number of data exceeds the setting value of
Sample Number option, it will delete the first record and insert the new
record into the last address. For example, if the setting value is set to 100
and the number of records in history exceeds 100, the first record will be
deleted and the second record will become to the third record, the third
record will become to the forth record…and the 100th record will become to
99th record. Therefore, the new record (101st record) will become to 100th
record.
Stamp Time and Use this option to determine if the time and date are also recorded during
Date sampling operation.
Auto Stop Use this option to determine if HMI stop recording when the max. number of
record data is reached.
Non-Volatile Using this option can enable to save sampling data in SRAM when the
power is turned off. The capacity for saving history data of DOP-A series is
240MBytes and DOP-AE series is 360MBytes. (The power of SRAM is
battery when the power is turned off.) (In some HMI models, the users can
save data in USB Disk or SMC card when the power is turned off and the
capacity for saving history data depends on the capacity of USB Disk or
SMC card.)
Trigger There are Timer and PLC two options.
OK / Cancel Press OK button to save the data and exit. Press Cancel to exit without
saving data.
Delete Pressing Delete button can delete a history data.
Modify Pressing Modify button can modify a history data.
Tag Table
Delete The users can use the mouse to select one row of the Tag table, and then press Delete button
to delete it.
OK Press OK button to save the settings and exit.
Cancel Press Cancel to exit without saving.
Print Typesetting