Multi-functional Flow Control Valve for

Water Treatment Systems


Hankscraft Runxin RevV20

Instruction Manual

Please read this manual in detail before using the valve and keep it in a safe place for future reference.
Hankscraft Runxin RevV20 Valve Manual

Before the valve is put into use, please fill in the below content.

Softener System Configuration

Tank Size: Dia. in/mm, Height in/mm;


Resin Volume ft /L; Brine Tank Capacity
3
L;
Hardness of Raw Water grains/mmol/L;
Pressure of Inlet Water psi/MPa;
Control Valve Model ;
Serial Number ; (13 digit number found on valve body)
Specification of Drain Line Flow Control ;
Injector No. ; Injector Color ;
Water Source: Ground-water□ Filtered Ground-water □Tap Water □
other .

Quick conversion table

1 inch 25.4 mm
1 ft3 (of resin) 28.32 L
1 kg 2.2 lbs.
1 gal 3.79 L
1 m3/h (per hour) 4.4 gal/m (per minute)
1 gpg 17.1 mg/L or (ppm)

Parameter Settings

Parameter Unit Factory Default Actual Value

Control Mode A-01 (02, 03, 04) A-01


Water Treatment Capacity (Meter type) m 3
80
Service Days (Time clock type, by days) D. 03
Service Hours (Time clock type, by hours) Hr. 20
Regeneration Time Hr:Min 02∶00
Backwash Time Min. 10
Brine & Slow Rinse Time Min. 60
Brine Refill Time Min. 05
Fast Rinse Time Min. 10
Interval Regeneration Days D. 30
Output Mode b-01 (b-02) b-01

● If there are no special requirement(s) when the product is purchased, the #3 drain line flow control and #3
injector (yellow), is used for standard configuration.
Hankscraft Runxin RevV20 Valve Manual

Notice ...................................................................................................
1. Product Overview ........................................................................... 2
1.1. Main Application & Applicability.................................................... 2
1.2. Product Characteristics ............................................................... 3
1.3. Service Condition ........................................................................ 5
1.4. Product Structure and Technical Parameters ............................... 6
1.5. Installation ................................................................................... 7
2. Basic Setting & Usage .................................................................. 10
2.1. The Function of PC Board ......................................................... 10
2.2. Basic Setting & Usage ............................................................... 11
3. Applications .................................................................................. 14
3.1. Flow Chart ................................................................................. 14
3.2. The Function and Connection of PC Board................................ 15
A. Signal Output Connector .............................................................. 16
B. Interlock ....................................................................................... 18
C. Pressure Relief Output ................................................................. 19
D. Remote Handling Connector ........................................................ 19
E. Interlock System .......................................................................... 19
F. Series System .............................................................................. 20
3.3. System Configuration and Flow Rate Curve .............................. 20
3.4. Parameter settlement ................................................................ 21
3.5. Parameter Enquiry and Setting .................................................. 23
3.6. Trial Running ............................................................................. 26
3.7. Trouble-shooting ........................................................................ 28
3.8. Assembly & Parts ...................................................................... 31

I
Hankscraft Runxin RevV20 Valve Manual

Preface

Thank you for choosing this Hankscraft Runxin water softening system for your water
treatment needs. Please read this manual carefully before attempting to use the system for the
first time, and ALWAYS adhere to all safety and operating instructions. Doing so will protect your
warranty and help keep your system running and operating safely and effectively.

***Before installing, read through this manual thoroughly. Failure to use this product
within the described conditions may void the warranty***

 All plumbing and electrical work should be performed by an accredited professional to ensure all
local, municipal, state, and federal guidelines are met.
 Do not use the control valve with water that is unsafe or of unknown quality. This system does not
sanitize or disinfect.
 Do not use the brine tube, injector body, or other connectors on the RevV valve as a handle to carry
the system.
 Ensure there is salt in the brine tank at all times when this valve is used for softening. The brine tank
should contain clean water and pellet softening salt only, at least 99.5% pure. The use of small grain
or solar salt is not recommended.
 When there is moderate to high turbidity, a filter should be installed before the water softening
system on the inlet side.
 If the water pressure exceeds 120psi, a pressure reducing valve must be installed before the water
inlet. If the water pressure exceeds 80 psi, installing a pressure reducing valve before the water inlet
is highly recommended. If the water pressure is under 21psi, a booster pump must be installed
before the water inlet.
 Replacement parts for the RevV valve should only be purchased through Hankscraft
resellers. Electrical components such as transformers are specific to the RevV valve from
Hankscraft.
 Regular interval monitoring of the water quality and work environment is recommended to insure
proper operation of the valve and system.

1. Product Overview

1.1. Main Application & Applicability

Used for softening, demineralization, or filtration of water treatment systems


RevV 20 (A & B), suitable for:
Ion exchange equipment, with raw water hardness ≤ 6.5mmol/L.
Boiler water softening system
RO pretreatment softening system, etc.

2
Hankscraft Runxin RevV20 Valve Manual

1.2. Product Characteristics

Overview
The advanced design incorporates a microcomputer control that analyzes real-world operating
conditions and performs regeneration automatically. This unique control valve features highly
polished, patented ceramic discs. The design incorporates one fixed and one moving disc,
which rotates through positions to align channels creating five different fluid pathways. These
five pathways, or stages, are: Service, Backwash, Brine & Slow Rinse, Brine Refill, and Fast
Rinse.

 Two Installation Options


Use side-mounted connector to change the valve from a top-mounted to side-mounted
system.

 Brine Refill Controlled By Electronic Ball Valve


During service, electronic ball valve will trigger during the brine refill.

 Manual Function
Regeneration can be prompted by pressing at any time.

 Extended Power Outage


If there is a power outage of more than 72 hours (3 days), the time of day indicator “” will
flash to remind the end user to reset the current time of day. The other set parameters do not
need to be reset. The system will resume working after power is restored.

 LED Dynamic Screen Display


Moving (green) display bar indicates the control valve is in service, otherwise, it is in the
regeneration cycle.

 Buttons Lock
If the display board is not in use for more than 1 minute the buttons will lock. A light indicating
this will appear. Before operating again press and hold the “ ” and “ ” buttons for 5 seconds
to unlock. This function can deter unintended operation.

 Program Model Selection


Press and hold “ ” and “ ” buttons for 2 seconds, all the icons will light up, indicating access
to the model setting interface. Press “ ” or “ ” to navigate to specific model, then press to
save the setting chosen, after reconnecting the power, the model will be visible on the display
board.

 Interlock Function
The interlock function is designed to have only one valve in regeneration, at a time, while
multiple other valves are in service in a parallel valve system. In multi-step treatment systems
such as RO pre-treatment, when several valves are in series, there is only one valve in
regeneration or washing to ensure product water at all times.(Application refer to Figure 3-9)

 All Parameters Can Be Modified


Depending on the water quality and usage, the parameters in the system can be adjusted.

3
Hankscraft Runxin RevV20 Valve Manual

 Signal Output
There is a signal output connector on the main control board. This connector is designed to
control external devices (Refer to Figure from Figure3-1 to Figure 3-8).

b-01 and b-02 output modes: b-01: a signal that is sent through the entire duration of
cycles during regeneration. In this mode, the signal can be sent once per cycle; b-02 Mode: the
signal is sent at the end of one cycle and at the beginning of another. In this mode, the signal is
sent five times per one complete cycle.

 Remote Handling Connector


This valve has a remote handling connector. An external device can determine when water
quality is below desirable levels. When this occurs, the valve has the capability to respond to a
remote signal and regenerate. (Application refer to Figure3-11)

 Pressure Relief Output


The valve will cut off feed water to the drain line when it switches in regeneration cycles (Same
as signal output b-02). Some water treatment system, e.g. Deep Well, one booster pump is
installed on the inlet to increase the system feed water pressure; this cut-off will prevent
pressure on inlet from rising too quickly, potentially preventing damage to the valve. Pressure
Relief Output can be used to avoid this problem. (For application refer to Figure3-10)

 Meter type(s) that can be selected (RevV 20)


Model Name Instruction
Regeneration happens when the capacity reaches zero and
A-01 Meter Delayed
the preset time of regeneration is reached.
A-02 Meter Immediate Regeneration happens when the capacity reaches zero.
Meter Delayed Regeneration type, but by setting Resin
Intelligent Meter Volume, Feed Water Hardness, Regeneration Factor, the
A-03
Delayed controller will calculate the System Capacity. Regeneration
mode is the same as A-01.
Meter Immediately Regeneration Type, but by setting Resin
Intelligent Meter
A-04 Volume, Feed Water Hardness, Regeneration Factor, the
Immediate
controller will calculate the System Capacity.
 Maximum Interval Regeneration Days
System will automatically regenerate even if the water capacity was not reached in the time
allotted. (Set on site)

4
Hankscraft Runxin RevV20 Valve Manual

1.3. Service Condition

Hankscraft valve(s) should be used within the below conditions:


Items Requirement

Working Water pressure 0.2MPa~0.6MPa (29-87psi)


conditions Water temperature 5℃~50℃ (41-122 F)
Environment temperature 5℃~50℃ (41-122 F)
Working
Relative humidity ≤95% (25℃) (77 F)
environment
Electrical facility AC100~240V/50~60Hz
Water turbidity < 5FTU
First Grade Na+ < 6.5mmol/L; Second
Water hardness
Grade Na+ < 10mmol/L
Inlet water
quality Free chlorine < 0.1mg/L or ppm
Iron2+ < 0.3mg/L or ppm
CODMn < 2mg/L (O2)

In the above table, First Grade Na+ represents First Grade Na+ Exchanger. Second Grade Na+
represents Second Grade Na+ Exchanger.

When the water turbidity exceeds the conditions, a filter should be installed on the inlet of
control valve.
When the water hardness exceeds the conditions, the outlet water hardness will hardly reach
the requirement of boiler feed water (0.03 mmol/L or 0.18 gpg). It is suggested to adopt a
second grade softener.

5
Hankscraft Runxin RevV20 Valve Manual

1.4. Product Structure and Technical Parameters

A. Product Dimension (The below images are used for reference and are subject to the real
product).

248.5

Riser Pipe
·I/2' D-GB
(SOmm)

Stmcture RevV 20-A2

9 06.5

BOITOM
02

_ TOP
02

( view without side eonnccloJ)

L~...f=:!~-~-, <f'Ba...,
_ gUN \ Flow Met«
Rire.-Pipe
1-t n. ' D-GB OOmm)
( v1cw without stdc ~<~neetor)

Structure ofRevV 20-B2

6
Hankscraft Runxin RevV20 Valve Manual

B. Technical Parameter

Transformer Output: DC24V/1.5A


Connector Size Flow Rate
Model Inlet/ Drain Brine Line Riser m3/h Remark
Base @0.3MPa
Outlet Outlet Connector Pipe
Time clock or
4”- 1.5″OD 10
RevV 20-A 2″M 1″M 3/4″M meter type;
8UN (50mm) (44GPM)
Top-mounted
Time clock or
4”- 1.5″OD 10
RevV 20-B 2″M 1″M 3/4″M meter type;
8UN (50mm) (44GPM)
Side-mounted

Remark: M—Male F—Female OD—Outer Diameters

1.5. Installation

A. Installation notice
Before installation, read all instructions completely. Then obtain all materials and tools
needed for installation.

The installation of the softening system, pipes, and circuits should be completed by a
certified water professional to ensure the product will function and operate correctly.

Perform installation according to the regional pipeline regulations and the specification of
Water Inlet, Water Outlet, Drain Outlet, and Brine Line Connector.

7
Hankscraft Runxin RevV20 Valve Manual

B. Device Location

① The filter or softener should be located close to the


drain.
② Ensure that the unit is installed with enough space for
operation and maintenance.
③ Brine tank needs to be close to the softener.
④ The unit should be kept away from heat, and should not
be exposed to the elements. Sunshine or rain will cause the
system damage.
⑤ Avoid introducing the system to Acid/Alkaline feed water
or Magnetism/vibration, as this may cause the system to
malfunction.
⑥ Do not install the filter, softener, or drain pipeline in
areas where temperature may drop below 5℃, or rise above
50℃. (41F~122F)
⑦ Install the system in a location where the risk of loss for
the customer is minimal, in case of water leaking.
C. Pipeline installation (RevV 20-A top-mounted as an example:
Figure 1-3)

① Install Control Valve

a. As the Figure 1-1 shows, select a riser pipe that is 50mm OD, glue the riser pipe to the
bottom strainer and put it into the mineral tank, cut the excessive tube off that is coming out the
top opening of the pressure tank. Plug the riser tube to prevent unwanted minerals.
b. Fill the mineral tank with resin, height according to the design code.
c. Attach the top distributor basket to the valve.
d. Insert and fasten the riser tube into the control valve.

Note:
●The length of riser tube should not be higher than 2mm nor lower than 5mm from the tank’s
top opening height, and its top end should be rounded to avoid damage of the O-ring inside the
valve.
●Avoid dropping the O-ring from inside the control valve while rotating it on the tank.

② Install Flow Meter

As below figure shows, put the sealing ring into the nut of the flow meter, and attach it to the
water outlet; insert sensor (probe wire) into the flow meter.

8
Hankscraft Runxin RevV20 Valve Manual

③ Pipeline Connection

a. As Figure1-3 shows, installation of a pressure gauge on water inlet.


b. Install sampling valves to inlet, outlet, and pipeline A.B.C.D.
c. Inlet pipeline should be parallel to outlet pipeline. Fasten the inlet and outlet pipeline(s) with a
fixed holders.

Note:
● If making a soldered copper installation, do all sweat soldering before connecting pipes to the
valve. Torch heat will damage plastic parts.
●When turning threaded pipe fittings onto plastic fitting, be sure not to cross thread.
●If the valve is a time clock type, skip step ②.

④ Install Drain Pipeline

 Glue the drain outlet with UPVC (DN40). Put drain


outlet pipe to sewer as shown in the Figure 1-4.

Note:
● Control valve should be higher than the drain outlet, and
should be separated from the drain hose by at least 2 inches.
● Be sure not to connect the drain line directly to the sewer to
avoid wastewater contamination.

⑤ Connect Brine Tube

a. As Figure1-5 shows, use 3/4” brine tube hose connector over the end of the brine tube.
b. Insert the tube bushing into the end of the brine tube.
c. Tighten the brine draw hose connector to the brine line connector.
d. Connect the other end of the brine line hose to the brine tank.

Note: Keep brine line short and smooth. Line should not be bent or plugged.

9
Hankscraft Runxin RevV20 Valve Manual

2. Basic Setting & Usage

2.1. The Functions of the PC Board

A. Time of day indicator

Light on,display the time of day.


Light flashes,reminds you to reset the time of day if electrical service was interrupted
for 3 days or more (If electrical service was interrupted for less than 3 days, there is no need to
reset the time).

B. Button lock indicator

 Light on, indicates the buttons are locked. At this time, pressing any single button will not work
(If the display is not used for 1 minute, will light and lock the buttons).
 Solution:to unlock press and hold both and for 5 seconds until the light turns off.

C. Program mode indicator

 Light on,enter program display mode. Use or to view all values.


 When flashes, enter program set mode. Press or to adjust values.

D. Menu/Confirm button

 Press , light turns on, enter program display mode and use or to view all values.
 In program display mode, press , will flash, enter program set mode, press or

10
Hankscraft Runxin RevV20 Valve Manual

and adjust values.


 Press after all programs are set, a confirmation beep will sound meaning all settings are
complete; returning to program display mode.

E. Manual/Return button

 Press in any status, it will proceed to next cycle. (Example: Press In Service status, it
will start regeneration cycles instantly; Press while it is in Backwash status, it will end
backwash and go to Brine & Slow Rinse).
 Press in program display mode, and it will return to in Service;
 Press in program set mode, and it will return program display mode.
 Press while adjusting the value, it will return to the program display mode directly without
saving value(s).

F. Down ▼ and Up ▲
 In program display mode, press ▲or ▼ to view all values.
 In program set mode, press ▲ or ▼ to adjust values.

2.2. Basic Setting & Usage

A. Parameter Specification
Factory Parameter
Function Indicator Instruction
Default set range
00:00~
Time of Day Set the time of day when “:” is flashing.
23:59
Regeneration happens when the capacity reaches
A-01
zero and the preset time of regeneration is reached.

Regeneration happens when the capacity reaches


A-02
zero.
Meter Delayed Regeneration type, but by setting
Control Mode A-01 A-01 Resin Volume, Feed Water Hardness, Regeneration
A-03
Factor, the controller will calculate the System
Capacity. Regeneration mode same as A-01.
Meter Immediately Regeneration Type, but by
setting Resin Volume, Feed Water Hardness,
A-04 Regeneration Factor, the controller will calculate the
System Capacity. Regeneration mode same as A-
02.
0~99
Service Days 1-03D. Only for Time Clock Type, regeneration by days.
Days
0~99
Service Hours 1-20H. Only for Time Clock Type, regeneration by hours.
Hours
Regeneration 00:00~
02:00 02:00 Regeneration time; when “:” light is on.
Time 23:59

11
Hankscraft Runxin RevV20 Valve Manual

Resin Volume 20L. 20L. 5-500L. Resin volume in brine tank (L).

Feed Water
Yd1.2 1.2 0.1-9.9 Feed water hardness (mmol/L).
Hardness
Exchange Related to the raw water hardness. When hardness
AL.65 0.65 0.30-0.99
Factor is higher, the factor is smaller.
Water
0~999.99 Water treatment capacity per cycle (m3).
Treatment 10 m3
m3
Capacity
Backwash Backwash time (Minute).
10 min. 0~99
Time
Brine & Slow Brine & Slow rinse time (Minute).
60 min. 0~99
Rinse Time
Brine Refill Brine refill time (Minute).
5 min. 0~99
Time
Fast Rinse Fast rinse time (Minute).
10 min. 0~99
Time
Maximum
Interval Regenerate on this day even though the available
H-30 30 0~40
Regeneration volume of treated water did not reach to zero (0).
Days
Mode b-01: Signal is sent at the start of
regeneration and shuts off at the end of
Output regeneration. (Connection refer to the Figure on P3)
b-01 b-01 b-01 or b-02
Control Mode Mode b-02: Signal is available only during intervals
of the regeneration cycles and in service
(Connection refer to the Figure on P3).

12
Hankscraft Runxin RevV20 Valve Manual

B. Process Display

Illustration

 In Service status, shown in figure A/B/C/D; In Backwash status, shown in figure E/C; In Brine &
Slow Rinse status, shown in F/C; In Brine Refill status, shown in figure G/C; In Fast Rinse
status, shown in figure H/C. In each status, every figure is shown for 15 seconds.
 Above displays are using the Meter Type as an example. For the Time Clock Type, it shows the
rest days or hours, such as 1-03D or 1-10H.
 The display screen will only show “-00-” when the electrical motor is running.
 The time of day figure “” flashes continuously, such as “12:12” flashing, indicates a long
outage of power. This is a reminder to reset the time of day.
 The display will show the error code, “-E1-” when the system is in error.

C. Working Process: Service→ Backwash→ Brine & Slow Rinse→ Brine Refill→ Fast
Rinse→ Service.

D. Usage
After installation is completed, parameters are set, and a trial run is completed, the valve is
ready to be put into use. In order to ensure the quality of outlet water, the user should complete
the steps below:
① Ensure that there is solid salt at all times in the brine tank when the valve is used for
softening. The brine tank should use softening salts only, 99.5% pure.
② Test the product water and raw water hardness on a regular basis. When the outlet
water hardness is at an undesired level, press the button; the valve will temporary
regenerate (It will not affect the original set operation cycle.)
③ When the feed water hardness changes, you can adjust the water treatment capacity as
follows:
Press and hold both and for 5 seconds to lift the lock status. Press , and the
light turns on, then press , the display shows the control mode. If it shows A-01 or A-02, press
two times, and the display will show the given water treatment capacity (If the control mode
shows A-03 or A-04, then press three times, the display will show the feed water hardness);
Press again, on display will flash. Press or to change the capacity value (Or water
hardness). Press a confirmation beep will sound finishing the adjustment. Press to exit
and return to service status.
To calculate the water treatment capacity, refer to the manufacturer’s specifications.
Selecting A-03 or A-04 intelligent control mode, the control will automatically calculate the water
treatment capacity by setting resin volume, feed water hardness, and regeneration factors.

13
Hankscraft Runxin RevV20 Valve Manual

④ For A-01 or A-03 control mode (Delayed regeneration type), ensure the time is set
correctly. If the time is not correct, you can adjust as follow: After lifting the lock status, press ,
the buttons and light will turn on. Then press , the buttons and hour value will
flash. Press or to change the hour value; Press again, and minute value will
flash. Press or to change the minute value; Press a confirmation beep will sound
finishing the adjustment. Press to exit and return to service status.
The regeneration parameters have been set when the control valve left the factory to
default settings or set up on initial installation. Generally, there is no need for it to be reset.

3. Applications

3.1. Softener Flow Chart

14
Hankscraft Runxin RevV20 Valve Manual

3.2. The Function and Connection of PC Board

Open the front cover of the control valve, you will see the main control board and
connection port as seen below:

Functions on PC board:
Function Application Explanation
Outlet If the system requires no hard water to flow from
solenoid valve outlet or if controlling the liquid level in water tank.
Signal output
connector b-01 Increase pressure for regeneration or washing.
Inlet pump Use the liquid level controller to control inlet pump,
ensuring there is water in tank.

Signal output Inlet solenoid valve or inlet Used when inlet pressure is high, closes water inlet
connector b-02 pump when valve is rotating to protect motor.

Pressure relief Control the inlet bypass to When valve is rotating, pressure relief connector
connector release pressure opens to prevent pressure from increasing rapidly.
To ensure only one control Used in RO Pre-treatment, water is supplied
Interlock
valve is in regeneration at a simultaneously but regenerate in turn. Also, used in
connector
time in a system. second grade ion exchange equipment, etc.
Remote It is used for on-line inspection systems, PC
Signal triggers the control to
handling connections, and automatic or remote controlling
rotate to the next cycle.
connector valve.

15
Hankscraft Runxin RevV20 Valve Manual

A. Signal Output Connector

1) Control Solenoid Valve (Set b-01)

① Solenoid valve on the outlet controls the water level in brine tank.

Instruction: If the system requires there to be no hard water flow from the outlet in regeneration
cycle (Mainly for no hard water flow out when valve is switching or valve is in backwash or brine
drawing positions), a solenoid valve could be installed on outlet, for wiring refer to Figure 3-1.

Function:
When valve is in service status, if soft water tank is short of water, solenoid valve is open to
supply soft water, but if water tank has enough water, solenoid valve is closed, and no soft water
is supplied.
When the valve is in backwash status, there is no signal output. Therefore, the solenoid valve
is closed, and no water flows into soft water tank.

② Solenoid valve on inlet (Set b-02)

Instruction: When inlet pressure exceeds (0.6MPa~87psi), install a solenoid valve on inlet.
Control mode is b-02. Pressure is relieved when valve is switching to prevent damage, for wiring
refer to Figure 3-2. As Figure 3-3 shows, it can also use the pressure relief port to work.

Instruction:
When inlet pressure is high, install a solenoid valve on inlet to ensure the valve can switch
properly. When valve is in position for Service, Backwash, Brine & Slow Rinse, Brine Refill and
Fast Rinse, solenoid valve is open. When valve is switching between cycles, the solenoid valve

16
Hankscraft Runxin RevV20 Valve Manual

is closed, ensuring no water can flow to the valve protecting it from damage during transition.
This can prevent water bleed through or water hammering.
Use interlock cables to daisy chain valves in parallel, or series, in the same system which is
suited for RO pretreatment system or second grade Na+ system. For wiring refer to Figure 3-4:

2) Liquid Level Controller Controls Inlet Pump (Two-phase motor) ( Set b-01)

Instruction: For a system using well or middle-tank supplying water, liquid level controller and
valve, together, control pump opening or closing. For wiring refer to Figure 3-5:

Function:
When the valve is in service, if the water tank is short of water, it starts the pump, but if the
tank has enough water, the switch of liquid level controller is closed, so the pump will not be in
operation.
When valve is in regeneration, inlet always has water no matter the condition(s) in the water
tank. Valve does not pass water through the outlet in regeneration cycle, ensuring no water
drains into the brine tank.

3) Liquid Level Switch in Water Tank Controls Inlet pump (Three-phase) (Set b-01)

17
Hankscraft Runxin RevV20 Valve Manual

4) Control Inlet Booster Pump (Set b-01 or b-02)

Instruction:
If inlet water pressure is less than (0.2MPa~29psi), which makes drawing difficult, a
booster pump is suggested to be installed on the inlet. Control mode b-01. When the system is
in regeneration, booster pump is open, for wiring refer to Figure 3-7. If the booster pump current
is higher than 5A, system needs to have a contactor installed. For wiring refer to Figure 3-8
below.

B. Interlock

Instruction:
In a parallel water treatment system, to ensure only one valve in regeneration or washing
cycle and (n-1) valves in service, that is, that the function of supplying water simultaneously and
regenerating individually, for wiring refer to Figure 3-9.

Note: Use Interlock Cable to connect CN8 to CN7 on next valve in the loop.
In a system with several valves, if the interlock cable is disconnected, the system will be
divided into two individual systems.

18
Hankscraft Runxin RevV20 Valve Manual

C. Pressure Relief Output

Valve will cut off feed water to the drain line when there is a switch in regeneration cycles.
In some water treatment system, e.g. Deep Well, one booster pump was installed on the inlet to
increase the system water feed pressure. This cut-off will prevent pressure on the inlet from
rising too fast, protecting the valve. Pressure Relief Output can be used to avoid this problem.
For wiring refer to Figure 3-10.

D. Remote Handling Connector

Online TDS meter can monitor treated water rather than a flow meter, or PLC controlling
the regeneration time. When the controller receives a contact closure from above instruments,
regeneration begins. For wiring refers to Figure 3-11:

E. Interlock System

For 2 or more valves that are interlocked, connected in one system, and when all valves are in
service but regenerate individually. For wiring refer to Figure 3-12.

19
Hankscraft Runxin RevV20 Valve Manual

F. Series System

This is a 2 or more valve system, all in service, with one flow meter for the entire system. For
the time type valve, the regeneration time should be set and adjusted to the Max; for the volume
type valve, connect its signal output connector with the remote handle connector of the time-
type valve. This provides the function of supplying water simultaneously and regenerating in
order. For wiring refer to Figure 3-13:

3.3. System Configuration and Flow Rate Curve

A. Product Configuration

Softener valve for floating bed configuration with tank, resin volume, brine tank and injector
model.

The Minimum Salt


Brine Tank
Tank Size Resin Volume Flow Rate Consumption for Injector
Size
(in & mm) (ft3 & L) (m3/h) Regeneration Model
(in & mm)
(lbs. & kg)
19.69”/500× 29.13”/740×
7.06/200 5.0 66.14/30.00 7401
70.87”/1800 50.20”/1275
23.63”/600× 29.13”/740×
10.60/300 7.0 99.21/45.00 7403
70.87”/1800 50.20”/1275
29.53”/750× 33.87”/840×
15.90/450 11.0 148.81/67.50 7404
70.87”/1800 52.56”/1335
Attention: The flow rate calculation is based on linear velocity 25m / hr.; the minimum salt
consumption for regeneration calculation is based on salt consumption 150g / L (Resin).

B. Flow Rate Characteristic

1) Pressure-flow Rate Curve

20
Hankscraft Runxin RevV20 Valve Manual

2) Injector Parameter Table


Inlet Pressure Draw Rate (Gal/m & L/m)
7401 7402 7403 7404
psi & MPa
Coffee Pink Yellow Blue

21.76/0.15 2.80/10.61 3.66/13.86 4.25/16.08 6.61/25.02


29.01/0.20 3.43/13.00 4.39/16.60 5.10/19.32 7.76/29.37
36.26/0.25 3.82/14.47 4.80/18.17 5.63/21.30 8.69/32.91
43.51/0.30 4.23/16.00 5.28/20.00 6.18/23.40 9.56/36.20
50.76/0.35 4.56/17.28 5.72/21.64 6.65/25.19 10.23/38.73
58.02/0.40 4.90/18.55 6.16/23.33 7.13/26.98 10.94/41.43

3) Configuration for Standard Injector and Drain Line Flow Control


Draw Slow Brine Backwash /
DLFC&
Tank Dia. Injector Injector Rate Rinse Refill Fast Rinse
Holes
In & mm Model Color Gal/m & Gal/m & Gal/m & Gal/m &
Quantity
L/m L/m L/m L/m
19.69”/500 7401 Coffee 4.23/16.0 2.79/10.56 6.08/23 #1 12.23/46.3
21.65”/550 7402 Pink 5.28/20.0 3.67/13.88 7.45/28.2 #2 17.70/67
23.62”/600 7403 Yellow 6.18/23.4 4.16/15.75 8.69/32.9 #3 18.76/71
29.53”/750 7404 Blue 9.56/36.2 6.39/24.17 13.34/50.5 #4 19.81/75
Attention: The above data for the product configuration and relevant characteristics are only for
reference. When put into practice, results are subject to the different requirements of raw water
hardness and application.

3.4. Parameter Settlement

① Service Time T1
Water treatment capacity:
Q=VR×K÷YD (m3)
Hardness of inlet water (mmol/L)

Exchange factor (mmol/L) 400~1000. Down-flow


regeneration, take 400~750. Up-flow regeneration, take
450~1000. If the inlet water hardness is higher, the factor
is smaller.

Resin volume (m3)

21
Hankscraft Runxin RevV20 Valve Manual

By hours: T1=Q÷Qh (Hour)

Water treatment capacity per hour (m3/h)


Water treatment capacity (m3)
By days: T1=Q÷Qd (Day)

Water treatment capacity per day (m3/d)


Water treatment capacity (m3)

② Backwash Time T2
It is subject to the turbidity of inlet water. Generally, It is suggested to be set to 10~15
minutes. The higher the turbidity is, the longer backwash time can be set. However, if the
turbidity is more than 5 FTU, it would be better to install a filter before the exchanger.

③ Brine & Slow Rinse Time T3


T3= (40~50) × HR (min.)
Generally, T3=45HR (min.)
In this formula, HR——the height of resin in exchange tank (m.)

④ Brine Refill Time T4


Down-flow regeneration:T4=0.45×VR÷Brine refill speed (min.)
Up-flow regeneration:T4=0.34×VR÷Brine refill speed (min.)
In this formula, VR—— Resin volume (m3)
The Brine refill speed is related to inlet water pressure. It is suggested to increase by 1~2
minutes of calculated brine refilling time to make sure there is enough water in tank. (The
condition is that there is a level controller installed in the brine tank).

⑤ Fast Rinse Time T5


T5=12×HR (min.)
Generally, the water for fast rinse is 3~6 times of resin volume. It is suggested to be set
10~16 minutes, but subject to the outlet water reaching the requirement.

⑥ Exchange Factor
Exchange factor =E / (k×1000)
In this formula, E——Resin working exchange capability (mmol/m3), it is related to the
quality of resin. Down-flow regeneration, take 800~900. Up-flow regeneration, take 900~1200.
K——Security factor, always take 1.2~2. It is related to the hardness of inlet water: the higher
the hardness is, the bigger the K is.

⑦ Regeneration Time
The whole cycle for regeneration is about two hours. Please try to set up the regeneration time
when you don’t need water according to the actual situation.
The calculation of parameters for each step is only for reference, the actual time will be
determined/adjusted by the water softener supplier. This calculation procedure of softener is
only for industrial application; it is not suitable for small softeners in residential applications.

22
Hankscraft Runxin RevV20 Valve Manual

3.5. Parameter Enquiry and Setting

3.5.1. Parameter Enquiry


When light is on, press and hold both and for 5 seconds to lift the button lock
status; then press and lights up, enter to program display mode; press or to view
each value according to below process. (Press to exit and return to service status).

3.5.2. Parameter Setting


In program display mode, press and enter into program set mode. Press or to
adjust the value.

23
Hankscraft Runxin RevV20 Valve Manual

3.5.3. The Steps of Parameter Setting

Items Process steps Symbol


When time of day “08:30” continuously flashes; it is a reminder to
reset;
1. Press to enter into program display mode; both and
symbol light on, “:” flashes; Press , both and hour value flash,
Time of Day use or to adjust the hour value;
2. Press again, both and hour value flash, use or to
adjust the minute value;
3. Press a confirmation beep will sound, then finish adjustment,
press to return.

1. In control mode display status, press and enter into program


set mode, and 01 values flash;
2. Press or , set the value to be A-01, A-02, A-03 or A-04
Control Mode
control mode
3. Press a confirmation beep will sound, then finish adjustment,
press to return.
1. In regeneration time display status, press and enter into
program set mode. and 02 flashes; Press or to adjust the
hour value;
Regeneration
Time 2. Press again, and 00 flashes, press or to adjust the
minute value;
3. Press a confirmation beep will sound, then finish adjustment,
press to return.
1. In water treatment capacity display status, it shows and 80.00.
Press and enter into program set mode. Press and 80.00 will
Water flash;
Treatment
2. Press or to adjust the water treatment capacity value (m3);
Capacity
3. Press a confirmation beep will sound, then finish adjustment,
press to return.
1. In resin volume display status, it shows 100 L. Press and
enter into program set mode. and 50 value will flash;
Resin Volume 2. Press or to adjust the volume value(L);
3. Press a confirmation beep will sound, then finish adjustment,
press to return.
1. In feed water hardness display status, it shows yd1.2. Press
and enter into program set mode. and 1.2 value flash;
Feed Water
Hardness 2. Press or to adjust the volume value(mmol/L);
3. Press a confirmation beep will sound, then finish adjustment,
press to return.

24
Hankscraft Runxin RevV20 Valve Manual

1. In exchange factor display status, it shows AL.55. Press and


enter into program set mode. and 55 flash;
Exchange
Factor 2. Press or to adjust the exchange factor value;
3. Press a confirmation beep will sound, then finish adjustment,
press to return.
1. In backwash time display status, it shows and 2-10. Press
and enter into program set mode. and 10 flash;
Backwash
2. Press or to adjust the backwash time;
Time
3. Press a confirmation beep will sound, then finish adjustment,
press to return.
1. In Brine& slow rinse time display status, it shows and 3-60:00.
Press and enter into program set mode. Press and 60 will
Brine& Slow flash;Press and , modify the Brine & slow rinse minute time;
Rinse Time modify the Brine & slow rinse second time;
3. Press a confirmation beep will sound, then finish adjustment,
press to return.
1. In Fast rinse time display status, it shows and 5-10:00. Press
and enter into program set mode. Press and 10 will flash;
Fast Rinse
Press and , to modify the Fast rinse minute time;
Time
2. Press a confirmation beep will sound, then finish adjustment,
press to return.
1. In Brine refill time display status, it shows and 4-05:00. Press
and enter into program set mode. Press and 05 flashes;
Brine Refill Press and , to modify the Brine refill minute time;
Time modify the Brine refill second time;
2. Press a confirmation beep will sound, then finish adjustment,
press to return.
1. In maximum Interval regeneration days display status, it shows
Maximum H-30. Press and enter into program set mode. Press and 30
Interval flashes;
Regeneration 2. Press or to adjust the Interval regeneration days;
Days 3. Press a confirmation beep will sound, then finish adjustment,
press to return.
1. In signal output mode display status, it shows b-01. Press and
enter into program set mode. and 01 will flash;
Signal Output 2. Press or to adjust the b-02;
Mode
3. Press a confirmation beep will sound, then finish adjustment,
press to return.
For example, the fast rinse time of a softener is 12 minutes. After regenerating, the chlorides in
the outlet water are always higher than normal, indicating that there is not enough time for fast
rinse. If you want to increase the fast rinse time, the modification steps as follows:

① Press and hold both and to lift the button lock status ( light off);

25
Hankscraft Runxin RevV20 Valve Manual

② Press , and lights up;

③ Press or continuously until lights up. Then the digital area shows: 4-12M;

④ Press , then and 12 will flash;

⑤ Press continuously until 12 changes to 15;

⑥ Press , there will be a confirmation beep and the figure will stop flashing; the program will
return to the adjustment status.

⑦ If you want to adjust other parameters, you can repeat the steps from ② to ⑤; if you
don’t, press and quit from the inquiry status, the display will show the current service status.

3.6. Trial Running

After installing the control valve on the resin tank with the connected pipes, and setting up
the relevant parameters for the system, please conduct a trail run as follows:

A. Close the inlet valve B & C, and open the bypass valve A. After cleaning the foreign
materials in the pipe, close the bypass valve A. (as Figure 1-4 shows)

B. Fill the brine tank with the planned amount of water and adjust the air check valve. Then
add solid salt to the tank dissolving the salt as much as possible.

C. Turn on power. Press and go in the Backwash position; when light is on (For
floating bed, switch valve to Fast Rinse), slowly open the inlet valve B to 1/4 position, making
the water flow into the resin tank; you should hear the sound of air-out from the drain pipeline.
After all of the air is out of the pipeline, open inlet valve B completely to clean the foreign
material out of the resin tank until the outlet water is clean. It will take 8~10 minutes to finish the
whole process depending on media.

D. Press , advancing the position from Backwash to Brine & Slow Rinse; when light is
on it indicates the valve is entering Brine & Slow Rinse. The air check valve closes when control
valve finishes drawing brine; slow rinse starts. About 60~65 minute process.

E. Press to get to Fast rinse position. Light turns on. It takes about 10~15 minutes.
Remove some outlet water for testing: if the water hardness reaches the desired requirement,
and the chlorides in the water are almost the same level compared with the inlet water, then
proceed to the next step.

F. Press to Brine refill position. When the light is on it indicates the brine tank is

26
Hankscraft Runxin RevV20 Valve Manual

being refilled with water to the required level. It takes about 5~6 minutes, then add solid salt to
the brine tank.

G. Press , this forces the control valve to advance to “In Service” status; light turns on
and valve will start running.

Note:

 When the control valve enters into the regeneration status, all programs will be finished
automatically according to the setting time; if you want one of the steps to terminate early, press
.

 If the water inflow is too fast, the media in tank will be damaged. When water inflow is too
slow, there is a sound of air emptying from the drain pipeline.

 After changing resin, empty air that is in the resin according to the above Step C.

 In the process of trial running, ensure there are no leakages in any cycle.

 The time for Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse position can be set
and carried out according to the calculation in the formula or suggestions from the control valve
suppliers.

27
Hankscraft Runxin RevV20 Valve Manual

3.7. Trouble-Shooting

A. Control Valve Fault

Problem Cause Correction

A. Electrical service to unit has been A. Verify permanent electricity (Check


interrupted. fuse, plug, pull chain or switch).
1. Softener fails to
B. Regeneration cycles set incorrectly. B. Reset regeneration cycles.
regenerate.
C. Controller is defective. C. Replace controller.
D. Motor fails to work. D. Replace motor.
2. Regeneration A. Time of Day is not set correctly. Check program and reset time of day.
time is not correct. B. Power failure for more than 3 days.
A. Close or repair bypass valve.
B. Add salt to brine tank and maintain
A. Bypass valve is open or leaking.
salt level above water level.
B. No salt in brine tank.
C. Change or clean injector.
C. Injector plugged.
D. Check brine tank refill time.
D. Insufficient water flowing into brine
E. Make sure riser pipe is not cracked.
tank.
3. Softener yielding Check O-ring and tube pilot.
E. Leak at O-ring on riser pipe.
hard water. F. Change valve body.
F. Internal valve leak.
G. Set correct regeneration cycles in
G. Regeneration cycles not correct.
the program.
H. Shortage of resin.
H. Add resin to mineral tank and check
I. Bad quality of feed water or turbine
whether resin leaks.
blocked.
I. Reduce the inlet turbidity, clean or
replace turbine.
A. Increase line pressure.
A. Line pressure is too low.
B. Clean brine line.
B. Brine line is plugged.
C. Replace brine line.
C. Brine line is leaking.
D. Clean or replace injector.
D. Injector is plugged.
4. Softener fails to E. Replace valve body.
E. Internal control leak.
draw brine. F. Clean drain line flow control.
F. Drain line is plugged.
G. Select correct injector size and
G. Sizes of injector and DLFC don’t
DLFC according to the P32
match system size.
requirements.
H. Ball valve or cable failure
H. Replace ball valve or cable
5. Unit uses too A. Improper salt setting. A. Check salt usage and salt setting.
much salt. B. Excessive water in brine tank. B. See problem no.6.
A. Brine refill time set too long.
A. Reset correct brine refill time.
B. Foreign material in brine line.
B. Clean brine line.
C. Foreign material in brine valve /
6. Excessive water C. Clean brine valve and brine line.
plugs drain line flow control.
in brine tank. D. Stop water supply and reinstall float
D. No overflow safety in brine tank /
assembly in brine tank.
float assembly.
E. Close or replace ball valve or cable.
E. Ball valve doesn’t close.
A. Iron in the inlet pipe. A. Clean the inlet pipe.
7. Pressure lost or
B. Iron mass in the softener. B. Clean valve and add resin cleaning
iron in outlet water.
C. Fouled resin bed. chemical, increase frequency of

28
Hankscraft Runxin RevV20 Valve Manual

D. Too much iron in the raw water. regeneration.


C. Check backwash, brine draw and
brine tank refill. Increase frequency of
regeneration and backwash time.
D. Iron removal equipment is required
to install before softening system.
A. Air in water system. A. Check that well system has proper
8. Loss of mineral B. Bottom distributor basket damaged. air elimination.
through drain line. C. Improperly sized drain line flow B. Replace bottom distributor basket.
control. C. Check for proper drain rate.
A. Locating signal writing breakdown.
A. Check and connect locating signal
B. Controller is faulty.
wiring.
9. Control cycles C. Foreign material stuck the driving
B. Replace controller.
continuously. gear.
C. Remove foreign material.
D. Time of regeneration steps were
D. Check program setting and reset.
set to zero.
A. Internal valve leak. A. Check and repair valve body or
10. Drain flows B. If there was a power outage during replace it.
continuously. the backwash cycle. B. Adjust valve to service position or
turn off bypass valve and restart.
A. Water pressure too low or not
A. Increase water pressure.
stable.
B. Clean or replace injector.
11. Interrupted or B. Injector is plugged or faulty.
C. Check and find the reason.
irregular brine. C. Air in resin tank.
D. Remove the material in resin tank.
D. Material in resin tank during
backwash.
A. Foreign material in the valve; valve
cannot close completely. A. Clean foreign material in valve body.
12. Water flows from B. Hard water mixed in valve body. B. Change valve core or sealing ring.
drain or brine line C. Water pressure is too high which C. Reduce water pressure or use
after regeneration. results in the valve not being in the pressure release device.
right position. D. Replace ball valve or cable.
D. Ball valve or cable failure.
A. Foreign material in injector or
A. Clean and repair injector.
13. Salt water in injector fails to work.
B. Repair brine valve or clean it.
softened water. B. Brine valve cannot be shut-off.
C. Extend rapid rinse time.
C. Time of rapid rinse too short.
A. Regenerate according to the correct
operation requirement.
A. Unit fails to regenerate or does not B. Increase backwash flow rate and
regenerate properly. time, clean or change resin.
B. Fouled resin bed. C. Readjust brine drawing time.
14. Unit capacity C. Salt setting incorrect. D. Test outlet water, recount, and reset
decreases. D. Softener setting incorrect. parameters.
E. Reduced quality of raw water. E. Manual regenerate the system
F. Turbine of flow meter is stuck. temporarily, then reset regeneration
cycle.
F. Disassemble flow meter and clean it
or replace turbine.

29
Hankscraft Runxin RevV20 Valve Manual

B. Controller Fault
Problem Cause Correction
A. Wiring of front panel failure. A. Check and replace the wiring.
1. All indicators
B. Control board is faulty. B. Replace control board.
displayed on front
C. Transformer damaged. C. Check and replace transformer.
panel.
D. Electrical service not stable. D. Check and adjust electrical service.
A. Wiring of front panel failure. A. Check and replace wiring.
2. No display on B. Front panel damaged. B. Replace front panel.
front panel. C. Control board damaged. C. Replace control board.
D. Electricity is interrupted. D. Check electricity.
A. Wiring of locating board failure. A. Replace wiring.
B. Locating board damaged. B. Replace locating board.
C. Mechanical driven failure. C. Check and repair mechanical part.
3. E1 Flash
D. Faulty control board. D. Replace control board.
E. Wiring of motor failure. E. Replace wiring.
F. Motor 1 damaged. F. Replace motor 1.
A. Wiring of locating board failure. A. Replace wiring.
B. Locating board damaged. B. Replace locating board.
C. Mechanical driven failure. C. Check and repair mechanical part.
4. E2 Flash
D. Faulty control board. D. Replace control board.
E. Wiring of motor failure. E. Replace wiring.
F. Motor 2 damaged. F. Replace motor 2.
6. E3 or E4 Flashes A. Control board is faulty. A. Replace control board.

30
Hankscraft Runxin RevV20 Valve Manual

3.8. Assembly & Parts

REVV 20-A (63610) exploring drawing

31
Hankscraft Runxin RevV20 Valve Manual

RevV 20-A: Valve Body Components (set up as filter: remove item no. 46 and no.47)

Item Item
Description Part No. Quantity Description Part No. Quantity
No. No.

1 O-ring 48.9x2.62 8378071 1 25 Dust Cover 8005010 1


2 O-ring 104.6X5.7 8378146 1 26 Control Board 6382027 1
Wire for Locating
3 Connector 8458018 1 27 5511002 1
Board
Screw, Cross Wire for Display
4 8909003 8 28 5512001 1
ST3.9X16 Board
Drain Line Flow
5 8468010 1 29 Display Board 6381003 1
Control
6 Injector 5468014 1 30 Front Cover 8300017 1
7 O-Ring 8371004 1 31 Label 8865016 1
8 Cover, Injector 8315006 1 32 Cable Clip 8126004 2
9 Hexagonal Nut 8940016 1 33 Wire for power 5513001 1
10 Tube 8457025 1 34 Pin 8994009 1
Screw, Cross
11 8909008 3 35 Small Gear 8241008 1
ST2.9X9.5
12 Seal Ring 8370016 1 36 Bolt C4X12 8971001 1
13 Fix Disk 8469010 1 37 Motor 6158036 1
14 Moving Disk 8459011 1 38 Hexagonal Nut 8940002 3
15 Moving Seal Ring 8370018 1 39 Line clip 8126002 1
Screw, Cross
16 Shaft 8258005 1 40 8902007 1
M4X20
Anti-friction
17 8216006 1 41 Connecting Board 8152007 1
Washer
O-ring Screw, Cross
18 8378110 2 42 8909016 4
59.92x3.53 ST3.9X16
O-ring Screw, Cross
19 8378133 1 43 8902005 1
117.6X3.55 M4×12
Screw, Cross
20 Fitting Nut 8092005 1 44 8902012 4
M4X36.5
Valve Body
21 Locating Board 6380015 1 8022052
(ABS+GF10)
45 1
Screw, Cross Valve Body
22 8909004 6 8022053
ST2.2X6.5 (PPO+GF10)
23 Gear 5241004 1 46 Flow Meter 5447003 1
Screw, Cross
24 8909018 1 47 Probe Wire 6386001 1
ST4.8X19

32
Hankscraft Runxin RevV20 Valve Manual

5447003 Flow meter:

5447003 Flow Meter Components:


Item Item
Description Part No. Quantity Description Part No. Quantity
No. No.
1 Animated Connector 8947004 1 5 O-ring 60X4 8378137 1
2 Seal Ring 8371008 1 6 Turbine 5436005 1
3 Connector 8458016 1 7 Rotator 8211003 1
4 Fixed Connector 8109006 1 8 Flow Meter Shell 8002702 1

5458002 Side-mounted Connector:

5458002 Side-mounted Connector Components:


Item Item
Description Part No. Quantity Description Part No. Quantity
No. No.
1 Connector 8458037 1 3 Joint 8457017 1
2 O-ring 110X4.5 8378140 1 4 Steel Yoke End 8271003 1

33
Hankscraft Runxin RevV20 Valve Manual

RevV 20-B (63610B) Exploring Drawing

34
Hankscraft Runxin RevV20 Valve Manual

RevV 20-B: Valve Body Components (set up as filter: remove item no. 38 and no.52)
Item Item
Description Part No. Quantity Description Part No. Quantity
No. No.
Wire for Locating
1 Side Connector 5458002 1 28 5511002 1
Board
Screw, Cross
2 8909003 8 29 Dust Cover 8005023 1
ST3.9X16
Three Core Spring
3 Connector 8458018 1 30 5517001 1
Line
4 O-ring 104.6X5.7 8378146 1 31 Bushings 8126006 1
5 O-ring 48.9x2.62 8378071 1 32 Wire Clip 8126001 1
Drain Line Flow
6 8468010 1 33 Front Box 8300025 1
Control
7 Cover, Injector 8315006 1 34 Label 8865023 1
8 O-ring 8371004 1 35 Display Board 6381003 1
9 Injector 5468013 1 36 Cover 8315016 1
10 Tube 8457025 1 37 Buckle 8126004 2
11 Hexagonal Nut 8940016 1 38 Probe Wire 6386002 1
12 Seal Ring 8370016 1 39 Wire for Power 5513001 1
13 Fix Disk 8469010 1 40 Pin 8994009 1
14 Moving Disk 8459011 1 41 Small Gear 8241008 1
15 Moving Seal Ring 8370018 1 42 BoltC4X12 8971001 1
16 Shaft 8258005 1 43 Motor 6158036 1
17 Anti-friction Washer 8216006 1 44 Hexagonal Nut 8940002 3
18 O-ring 59.92x3.53 8378110 2 45 Buckle 8126002 1
19 O-ring 117.6X3.55 8378133 1 46 Screw, Cross M4X20 8902007 1
20 Fitting Nut 8092005 1 47 Connecting Board 8152007 1
Screw, Cross
21 Locating Board 6380015 1 48 8909016 4
ST3.9X16
Screw, Cross
22 8909004 6 49 Screw, Cross M4×12 8902005 1
ST2.2X6.5
Screw, Cross
23 Gear 5241004 1 50 8902012 4
M4X36.5
Screw, Cross Valve Body
24 8909018 1 8022052
ST4.8X19 (ABS+GF10)
51 1
Valve Body
25 Fixed Base 8109004 1 8022053
(PPO+GF10)
26 Control Board 6382027 1 52 Flow Meter 5447003 1
Screw, Cross
27 8909008 15
ST2.9X9.5

35