1 GENERAL i) Name of Manufacture KEI INDUSTRIES LIMITED ii) No. of Cores 3.5 iii) Area Sq.mm 50 iv) Cable Type / Code A2XFY - FR-LSH v) Voltage Grade 1100 Volts vi) Standards Applicable IS: 7098 (Part I) 1988, IS:5831-1984, IS:8130-2013 ,IS 3975-1999 2 CONDUCTOR i) Material Stranded (Class 2) H2/H4 Grade Aluminium conductor as per IS : 8130-2013 ii) Shape Compacted Sector Shaped iii) Cross Sectional Area (Main) sq.mm. 50 iv) Cross Sectional Area (Reduced Neutral) sq.mm. 25 3 INSULATION i) Material Extruded Cross linked polyethylene (XLPE) as per IS 7098 Part-1 : 1988 ii) Thickness (Nom.) (Main) mm 1 iii) Thickness (Nom.) (Reduced Neutral) 0.9 iv) Core identification Red,Yellow,Blue & Black v) Tensile Strength (Min.) - XLPE 12.5 N/sq.mm vi) Elongation at break (Min.) - XLPE 200% vii) Dielectric Strength 20-30 kV/mm 4 INNER SHEATH i) Material Extruded PVC Type ST-2 as per IS: 5831-1984 ii) Thickness (Min.) mm 0.3 iii) Colour Black 5 ARMOUR i) Material Galvanized Steel as per IS : 3975-1999 ii) Type Flat Strip iii) Size - Nominal mm ( Width x Thickness) 4.0 x 0.8 iv) Tape over armour Suitable Water Swellable tape shall be provided over armour 6 OUTER SHEATH Extruded PVC Type ST-2 as per IS: 5831-1984 with FR-LSH, Anti Rodent & termite, UV i) Material Resistant Properties ii) Thickness(Min.) mm 1.40 iii) Colour Black iv) Approx. Overall dia of cable mm 27.7 v) Tolerance on overall dia ± 3 mm 6A FR-LSH Properties i) Oxygen Index at room Temp °C. 29% Min. as per ASTM-D-2863 ii) Temperature Index. Min. 250 deg.C. as per ASTM-D-2863 iii) Smoke density Rating 60% max. as per ASTM-D-2843 iv)Acid Gas Generation 20% max. as per IEC 60754-1 v)Flammability test As per IEC 60332-1 7 ELECTRICAL DATA i) Max DC resistance at 20 deg C (Main) Ω/Km 0.641 ii) Max DC resistance at 20 deg C (Neutral) Ω/Km 1.20 iii) Max. AC Resistance at 90 deg C (Main) Ω/Km 0.820 iv) Capacitance µf/Km 0.50 v) Reactance at 50Hz Ω/Km 0.078 vi) Current Ratings a)In ground at 30 deg C Amps 134 b)In air at 40 deg C Amps 138 vii) Short circuit rating of conductor KA for 1 second 4.7 viii) Volume Resistivity Ω. cm a) at 27 deg.c. 1 x 10^14 b) at 90 deg.c. 1x 10^12 ix) Conductor Temperature a) under normal operating conditions 90 0C. b) at the termination of short circuit 250 0C. x) HV Test Voltage (AC, for 5 min. as per IS) 3 kV (rms) 8 CABLE DATA i) Standard Drum Length Meters with ± 5% tolerance 1000 ii) Drum Material Non returnable Wooden iii) Pulling Force a)for Cables pulled with stocking 9 x D² Newtons, D is the cable OD in mm b) Cables pulled with pulling eyes 5250 Newtons iv) Printing/Embossing Manufacturer's Name , Voltage Grade, Cable Size & Type ,Year Of Manufacturing, FR-LSH v) Min. Bending radius 12 x D ( where D is overall diameter ) vi) Sequential Marking Shall be provided at every one meter
NOTE :- Suitable Binder/Wrapping tapes shall be provided wherever necessary. The values given above are subject to tolerances as per the relevant standards