Professional Documents
Culture Documents
15 Hidraulico Inicial A320 Alfa Jun23
15 Hidraulico Inicial A320 Alfa Jun23
EN EL EQUIPO
A320/A319 FAMILY
AGOSTO - 2022
2
3
SISTEMA HIDRÁULICO (ATA 29)
A T E N C I Ó N:
LA PRESENTE PUBLICACIÓN HA SIDO PREPARADA CON
EL ÚNICO PROPÓSITO DE CAPACITACIÓN Y ADIESTRAMIENTO
DEL SISTEMA HIDRÁULICO ATA 29 DE LOS EQUIPOS A319 –
A320.
3
CURSO INICIAL A320/A319 FAMILY
The aircraft has three independent hydraulic systems: The yellow hydraulic system can also be
- green, pressurized by an electric pump.
- yellow,
- blue. It is mainly used on ground for maintenance and
cargo door operation.
The three hydraulic systems supply hydraulic power at
3000 psi to the users: If no electric power is available, a hand pump in
- flight controls, the yellow system can be used to operate the
- landing gear, cargo doors.
- brakes,
- nose wheel steering, A Power Transfer Unit (PTU) enables the green
- cargo doors, system to be pressurized by the yellow system
- thrust reverser operation, and vice versa. It transfers the hydraulic power
- Constant Speed Motor / Generator (CSM/G). but does not transfer the hydraulic fluid.
Hydraulic fluid cannot be transferred from one system Fire shut-off valves shut off Hydraulic fluid supply
to another. to the EDPs in case of fire.
A reservoir in each hydraulic system is pressurized They isolate the systems in case of an engine
with air to prevent cavitation. fire.
PURPOSE: The three hydraulic systems supply hydraulic power at 3000 psi
to the users:
FLAPS
SLATS
THRUST CSM/G
REVERSER
Constant Speed Motor / Generator
FLIGHT CONTROLS
5
CURSO INICIAL A320/A319 FAMILY
6
SISTEMA HIDRÁULICO (ATA 29)
SYSTEM OVERVIEW
7
CURSO INICIAL A320/A319 FAMILY
The RAT is an auxiliary pressure supply for the In the event of low hydraulic
blue system, and for the emergency electrical pressure, the priority valves
power CSM/G. maintain the operation of
It can be deployed automatically or manually
depending on the failure conditions. essential systems by cutting off
The RAT is locked when extended. hydraulic power to heavy load
An index lock mechanism will only permit RAT users.
stowage if the blades are properly aligned.
It also prevents rotation when stowed. The
index lock will release at approximately 5
degrees from the full extension position.
Extension is by spring force. Retraction
(stowage) is by blue hydraulic pressure.
Up lock release is by solenoid operation.
Down lock release is by hydraulic pressure.
8
SYSTEM OVERVIEW
Auxiliar source
G&Y
Normal source
Normal source Normal source Auxiliar source
Auxiliar source
9
SISTEMA HIDRÁULICO (ATA 29)
RAT
11
SISTEMA HIDRÁULICO (ATA 29)
12
SYSTEM OVERVIEW - PTU & RAT
CURSO INICIAL A320/A319 FAMILY
COMPONENT LOCATION
PTU/ELEC PUMPS/RAT
13
SISTEMA HIDRÁULICO (ATA 29)
14
COMPONENT LOCATION - PTU/ELEC PUMPS/RAT
CURSO INICIAL A320/A319 FAMILY
ENGINE PUMP
RESERVOIR
15
SISTEMA HIDRÁULICO (ATA 29)
SERVICING PANELS
17
SISTEMA HIDRÁULICO (ATA 29)
COMPONENT LOCATION
SERVICING PANELS
18
CURSO INICIAL A320/A319 FAMILY
PRIORITY VALVES
19
SISTEMA HIDRÁULICO (ATA 29)
PIPE ROUTING
pipe identification
21
SISTEMA HIDRÁULICO (ATA 29)
22
CURSO INICIAL A320/A319 FAMILY
ACOUSTIC FILTER
PRESSURE SWITCH
24
CURSO INICIAL A320/A319 FAMILY
27
SISTEMA HIDRÁULICO (ATA 29)
The optional leak measurement manifold supplies the - One temperature sensor which has one
flight controls of the RH wing, LH wing and tail section temperature switch and two temperature
via three outputs. After closing the related leak transducers.
measurement valve, operating manually a spool valve
lets the related section be supplied for leak The red pin of clogging indicator comes out when
measurement testing. the differential pressure across the filter is more
than 29 ± 4.4 psi (2 ± 0.3 bar).
PTU MANIFOLD
The by-pass operates when the differential
The PTU manifold is composed of three different pressure across the filter is more than 58 ± 6.0
valves: psi (4.0 ± 0.4 bar). Then the device lets the fluid
go from inlet to outlet without filtration. The
-The normal braking selector valve which cuts
temperature switch and temperature transducers
the hydraulic supply to the normal brakes,
send data for ECAM warnings and indication on
-The solenoid valve installed in the PTU supply line overhead P/Bs.
which stops the PTU operation,
-The priority valve which makes sure that all
available hydraulic pressure is sent to the primary flight
controls if pressure in the system is reduced.
RETURN MANIFOLD
31
SISTEMA HIDRÁULICO (ATA 29)
PTU INHIBITED
34
ELECTRIC PUMP
RESERVOIR
With the ELECtric (ELEC) PUMP P/B set to
The reservoir has a direct reading gage, a quantity
indicator and a low level switch for ECAM indicating
AUTO, the blue electric pump will run, if one
and warning. Normal fill level: 6 l (1.58 US gal). engine is running, or the BLUE PUMP
Maximum gageable level: 8 l (2.11 US gal). Low level OverRiDe (OVRD) P/B is set to ON, or NLG is
warning: between 2.0 and 2.3 l (0.52 and 0.6 US gal). not compressed and AC power is available
from the APU.
RESERVOIR PRESSURIZATION
With the last condition, at touchdown a time
delay relay maintains the pump operation for
The reservoir is normally pressurized with air to
two minutes after NLG compression. The
prevent pump cavitation.
pump outlet pressure is 3000 psi (206 bar) at
zero flow.
The reservoir is pressurized to 50 psi (3.43 bar) and
is sealed to hold the pressure when there is no air
A temperature switch sends a signal to the
supply. The threshold of the air pressure switch is ECAM if the pump body temperature exceeds
22 psi (1.52 bar). The threshold of the air pressure 165°C. The electric pump cooling and
relief valve is 77 psi (5.3 bar). lubricating flow goes through the case drain
filter installed in the return circuit. Case drain
filter clogging indication: P = 87 ± 8.7 psi (6 ± 0.6
bar).
35
SISTEMA HIDRÁULICO (ATA 29)
The acoustic filter is installed in the outlet from the blue On ground it is possible to pressurize the blue
electrical pump. hydraulic system from a ground power unit.
PRESSURE SWITCH
37
B2 SCOPE ... GROUND COUPLINGS
SISTEMA HIDRÁULICO (ATA 29)
CURRENT TRANSFORMER
AND PHASE UNBALANCE DETECTOR
(HYD/BLUE/ELEC PUMP)
38
CURSO INICIAL A320/A319 FAMILY
39
CURRENT TRANSFORMER AND PHASE UNBALANCE DETECTOR
SISTEMA HIDRÁULICO (ATA 29)
The High Pressure (HP) manifold is composed of: The leak measurement valve isolates the flight
- two pressure switches, controls when the guarded LEAK
- a pressure transducer, MEASUREMENT VALVES P/B on the
- a leak measurement valve, maintenance panel is set to OFF.
- a HP filter,
- a priority valve, HP FILTER
- a pressure relief valve,
- a sampling valve. The HP filter has a clogging indicator. The
clogging indicator operates when the differential
PRESSURE SWITCHES pressure is higher than 87 ± 8.7 psi (6 ± 0.6 bar).
40
CURSO INICIAL A320/A319 FAMILY
SAMPLING VALVE
ACCUMULATOR
41
SISTEMA HIDRÁULICO (ATA 29)
42
HIGH PRESSURE MANIFOLD & ACCUMULATOR
CURSO INICIAL A320/A319 FAMILY
RETURN MANIFOLD
PRESSURE SWITCH
GROUND COUPLINGS
46
CURSO INICIAL A320/A319 FAMILY
HAND PUMP
ELECTRIC PUMP
48
CURSO INICIAL A320/A319 FAMILY
CURRENT TRANSFORMER
AND PHASE UNBALANCE DETECTOR
(HYD/YELLOW/ELEC PUMP)
50
CURSO INICIAL A320/A319 FAMILY
52
CURSO INICIAL A320/A319 FAMILY
53
POWER TRANSFER UNIT (PTU) - PTU NORMAL OPERATION (NOT INHIBITED)
SISTEMA HIDRÁULICO (ATA 29)
PTU INHIBITED
55
POWER TRANSFER UNIT (PTU) - PTU INHIBITED
SISTEMA HIDRÁULICO (ATA 29)
The pressure transducer gives data for pressure A sampling valve is installed on the HP manifold.
indication on the ECAM and sends information to
ELevator Aileron Computers (ELACs) 1 and 2. NOTE: CAUTION: when sampling, let the fluid
run for a moment into a container, then put 0.2L
(0.05USG) of fluid into an appropriate bottle for
analysis.
56
CURSO INICIAL A320/A319 FAMILY
LEAK MEASUREMENT MANIFOLD (OPTIONAL) The priority valve makes sure that all available
hydraulic pressure is sent to the primary flight
The optional leak measurement manifold supplies the controls if pressure in the system is reduced.
flight controls of the RH wing, LH wing and tail section
via three outputs. Operating manually, a spool valve
lets the associated section of the flight controls be
supplied for leak measurement testing.
PTU MANIFOLD
57
The PTU manifold is composed of one disconnection
SISTEMA HIDRÁULICO (ATA 29)
RETURN MANIFOLD
The red pin of the clogging indicator pops out when the
differential pressure across the filter is more than 29 ±
4.4 psi (2 ± 0.3 bar).
58
CURSO INICIAL A320/A319 FAMILY
59
HP MANIFOLD ... RETURN MANIFOLD
SISTEMA HIDRÁULICO (ATA 29)
WATER SEPARATOR
switch generates LOW AIR PRESS warning if
A water separator is installed on the reservoir the pressure is less than 22 psi (1.52 bar).
pressurization unit. It makes sure that the air delivered
to the reservoirs is clear of any fluid. There are two PRESSURE RELIEF VALVE
drain valves that prevent freezing of the water in the
reservoir pressurization unit. One is an automatic drain A pressure relief valve, installed on each
valve that is opened after each engine or APU reservoir, relieves pressure to the atmosphere in
shutdown; the other one is a manual self-sealing drain the event of a system overpressure. The
valve. threshold of the pressure relief valve is 77 psi
(5.3 bar).
RESERVOIR CHECK VALVE
MANUAL DEPRESSURIZATION VALVE
Downstream of the reservoir pressurization unit, the air
supply is divided into three flows to supply the A manual depressurization valve is fitted on each
reservoirs through their related check valve. ground service panel to depressurize each
reservoir.
The green and yellow check valves are installed
between the floor beams above the hydraulic bay and WARNING: WHEN USING THE MANUAL
the blue one is installed in the aft cargo compartment. DEPRESSURIZATION VALVE, PUT ON EYE
PROTECTION AND KEEP AWAY FROM THE
PRESSURE GAGE OUTLET OF THE VALVE. THE AIR CAN BE
HOT AND CONTAIN PARTICLES OF DUST
An air pressure gage is installed on each hydraulic AND/OR HYDRAULIC FLUID.
reservoir to indicate the actual pressure. The pressure
61
SISTEMA HIDRÁULICO (ATA 29)
63
SISTEMA HIDRÁULICO (ATA 29)
CHECK VALVE
64
CURSO INICIAL A320/A319 FAMILY
SERVICING
RESERVOIR AIR PRESSURIZATION
All three reservoirs are pressurized to 50 psi to prevent It is put into the blue hydraulic bay and
pump cavitation. adjusts the normal or ground supply to 50 psi.
The non-return valves are in each reservoir supply There are two water drains: one is automatic
manifold. Make sure that the pressure is kept for until after engine and APU shutdown, and the other is
12 hours after engine shutdown on ground and for until manually operated.
3 hours after a failure of the air supply in flight.
After maintenance on the hydraulic system, the
Each reservoir has a depressurization valve on its reservoir pressurization can be done with a
related service panel. pneumatic ground cart connected to the reservoir
pressure unit, the APU or the pneumatic system
For long time depressurization, a depressurization tool ground connection.
can be installed on the depressurization valve.
67
68
CURSO INICIAL A320/A319 FAMILY
69
SERVICING - FLUID LEVEL CHECK
SISTEMA HIDRÁULICO (ATA 29)
70
SISTEMA HIDRÁULICO (ATA 29)
RESERVOIR FILLING
Set the yellow electric pump to ON to make sure that Large changes in ambient temperature can also
the brake accumulator is pressurized, then set the have an effect on the reservoir level. For every
pump to OFF. 10°C change, the green and yellow volumes
change by 0.50 l and the blue volume changes
Connect the selected servicing source to the green by 0.25 l.
servicing panel.
When you use the panel hand pump, connect the hose
to the hand pump and insert it into the fluid container,
and then install the pump handle. The handle is stowed
at the yellow servicing panel.
BLEEDING
If you have filled the reservoir after: -read the gauge of the associated reservoir and
- maintenance, make a note of the fluid level,
- or removal/installation of large hydraulic components, -depressurize the reservoir of the associated
-or hydraulic fluid low level (loss of the hydraulic hydraulic system,
system), -after 5 minutes, read the gauge again and make
- or high loss of hydraulic fluid, a note of the level,
- compare both levels,
Do the related bleeding procedure to make sure that -if the difference between both levels is more
the quantity of hydraulic fluid in the system is correct. than 2 liters, do the bleeding procedure again
until the result is satisfactory.
For instance, after maintenance of the hydraulic
system upstream of the EDP.
Loosen the nut of the case drain hose so that the air
(or hydraulic fluid mixed with air bubbles) comes out of
the connection. Wait until the fluid flows freely and
tighten the nut again.
74
SERVICING - BLEEDING
SISTEMA HIDRÁULICO (ATA 29)
75
CURSO INICIAL A320/A319 FAMILY
76
SISTEMA HIDRÁULICO (ATA 29)
77
SERVICING - HIGH PRESSURE (HP), CASE DRAIN, AND LOW PRESSURE (LP) FILTERS
MANUALES DEL FABRICANTE ……..