PUMP FRAME KW RATING


SIZE PV* 15 For contact details - PUMP

40 VC 15 PERFORMANCE
visit www.warman.co.za CURVE
VCH 15 REFERENCE
TYPE
IMPELLER SP4206 LINER
WPG
SP VANES TYPE MAT’L VANE O MAT’L
40SP31
5 OPEN METAL 188 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER 12 mm
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE 2800
PRESENCE AND EFFECTS OF SOLIDS
SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

60
Note:
Shaft length to be checked
for suitability at selected
operating speed

50

2800
20%
30%
35%
40%
2600
H (m)

40

2400 44%

30
2200

Reference Test: Curve Redrawn


2000

20 1800

1600 40%

1400

10
1200
35%
1000
Revision: 0

0
0 5 10 15 20 25
Q (l/sec)
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE PV* 15 For contact details - PUMP

40 15 PERFORMANCE
VC
visit www.warman.co.za CURVE
VCH 15 REFERENCE
TYPE
IMPELLER SP4191 LINER
WPG
SP VANES TYPE MAT’L VANE O MAT’L
40SP74
8 CYKLO METAL 190 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
26 mm
PRESENCE AND EFFECTS OF SOLIDS
2600 SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

40
Note:
2600 Shaft length to be checked
15% for suitability at selected
r/min
25% operating speed
30%
35

2400

36%
30

2200
H (m)

25
30%

2000

20

1800

Reference Test: Curve Redrawn

15
1600

1400

10

1200

5
Revision: 0

0
0 2 4 6
Q (l/sec) 8 10 12 14 16
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE QV* 30 For contact details - PUMP

65 VD 30 PERFORMANCE
visit www.warman.co.za CURVE
VDH 30 REFERENCE
TYPE
IMPELLER SP65206A LINER
WPG
SP VANES TYPE MAT’L VANE O MAT’L
65SP31
5 OPEN METAL 280 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
15 mm
PRESENCE AND EFFECTS OF SOLIDS
1850 SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

50 1850 25% Note:


35% Shaft length to be checked
40% for suitability at selected
45% operating speed
45
48%
50%
1700
40
51%

50%
35
48%
H (m)

1500

30

25
1300

Reference Test: Curve Redrawn


20

1100

15

900

10

700

5
Revision: 0

0
0 5 10 15 20 25 30 35 40
Q (l/sec)
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE QV* 30 For contact details - PUMP

65 30 PERFORMANCE
VD visit www.warman.co.za CURVE
VDH 30 REFERENCE
TYPE
IMPELLER SP65191 LINER
WPG
SP VANES TYPE MAT’L VANE O MAT’L
65SP74
8 CYKLO METAL 290 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
40 mm
PRESENCE AND EFFECTS OF SOLIDS
1850 SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

50
Note:
Shaft length to be checked
for suitability at selected
1850
45 20% operating speed
25%
30%
35%
40
1700

38%
35
H (m)

1500
30
35%

25
30%
1300

Reference Test: Curve Redrawn


20

1100
15

900
10

700
25%
5
Revision: 0

0
0 5 10 15 20 25 30 35 40 45 50
Q (l/sec)
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE RV* 75 PUMP
For contact details -
100
PERFORMANCE
VE 75
VEH 75 visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER SP10206A LINER
WPG
SP VANES TYPE MAT’L VANE O MAT’L
100SP31
5 OPEN METAL 370 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER 32 mm
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS
1400 SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

60
Note:
Shaft length to be checked
for suitability at selected
operating speed

1400 20% 30%


50
r/min 40% 45%
50%

1300 55%

56%
H (m)

40

1200
55%

1100
30

1000

Reference Test: Curve Redrawn

900
20

800

700

10
600

500
Revision: 0

0
0 20 40 60 80 100 120
Q (l/sec)
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE RV* 75 PUMP
For contact details -
100
PERFORMANCE
VE 75
visit www.warman.co.za CURVE
VEH 75 REFERENCE
TYPE
IMPELLER SP10206A LINER
SP VANES TYPE MAT’L VANE O MAT’L WPG
5 OPEN POLYURETHANE 370 METAL 100SR33
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE

Last Issue: April 2003


MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER 32 mm
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS
1400 SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

60
Note:
1486
20%
Shaft length to be checked
30% for suitability at selected
r/min 40%
45% operating speed
50%

1400
50
55%

56%

1300

55%
H (m)

40

1200

1100
30

1000

Reference Test: Curve Redrawn

900
20

800

700

10
600

500
Revision: 0

0
0 20 40 60 80 100 120
Q (l/sec)
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE RV* 75 PUMP
For contact details -
100 VE 75 PERFORMANCE

VEH 75
visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER SP10191 LINER
WPG
SP VANES TYPE MAT’L VANE O MAT’L
100SP74
8 CYKLO METAL 390 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER 70 mm
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS
1400 SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

50
Note:
Shaft length to be checked
for suitability at selected
operating speed
45
1400 20%25%
r/min 30%
35%

40 40%
1300

35 42%
H (m)

1200

30
40%
1100

25

1000

Reference Test: Curve Redrawn


20
900

15 800
35%

700
10
600 Q (l/sec)
30%

5
NPSH (m)

Revision: 0

0
0 10 20 30 40 50 60 70 80 90 100
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE SV* 110 PUMP
For contact details -
150
PERFORMANCE
visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER SP15206A LINER
SP VANES TYPE MAT’L VANE O MAT’L WPG
5 OPEN METAL 480 METAL 150SP31
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE
MIN PASSAGE SIZE
NORM MAX RPM
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER 45 mm
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS
1000 SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

40
Note:
1000 20% 30% Shaft length to be checked
40% for suitability at selected
r/min 45% operating speed
50%
35
52%

900
55%
30
H (m)

25
800 52%

20
700

Reference Test: Curve Redrawn


15
600

10
500

Q (l/sec)

5
NPSH (m)

Revision: 0

0
0 20 40 60 80 100 120 140 160 180
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE SV* 110 PUMP
For contact details -
150
PERFORMANCE
visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER SPR15206A LINER
SP VANES TYPE MAT’L VANE O MAT’L WPG
5 OPEN POLYURETHANE 450 METAL 150SR33
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
45 mm
PRESENCE AND EFFECTS OF SOLIDS
1000 SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

40
Note:
Shaft length to be checked
for suitability at selected
1000 20% operating speed
30%
r/min 40%
35
45%
50%
53%

30
900
55%
H (m)

53%
25

800

20

700

Reference Test: Curve Redrawn


15

600

10
500

5
Revision: 0

0
0 20 40 60 80 100 120 140 160 180
Q (l/sec)
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE SV* 110 PUMP
For contact details -
150
PERFORMANCE
visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER SP15191 LINER
SP VANES TYPE MAT’L VANE O MAT’L WPG
8 CYKLO METAL 460 METAL 150SP74
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE
MIN PASSAGE SIZE
NORM MAX RPM
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER 75 mm
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS
1000 SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

40
1000 Note:
20% Shaft length to be checked
r/min for suitability at selected
30%
operating speed
35%
35
38%

900
40%
30

38%
H (m)

25
800 35%

20
700

Reference Test: Curve Redrawn


15
600

10 500

5
Revision: 0

0
0 20 40 60 80 100 120 140 160 180
Q (l/sec)
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE SV* 110 PUMP
For contact details -
200
PERFORMANCE
visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER SP20206 LINER
SP VANES TYPE MAT’L VANE O MAT’L WPG
5 OPEN METAL 520 METAL
200SP31
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
NO SUBMERGED BEARINGS June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
65 mm
PRESENCE AND EFFECTS OF SOLIDS
850 SPHERE
For Standard Length
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

45
Note:
Shaft length to be checked
850 for suitability at selected
r/min operating speed
30%
40
40%
50%
800 58%
35
62%

750
64%
H (m)

30

700
62%

25
650

600
20

550 Reference Test: Curve Redrawn

15
500

450

10
400

5
Revision: 0

0
0 50 100 150 200 250 300
Q (l/sec)