You are on page 1of 1

Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE G* 600 PUMP
For contact details -
12/10
PERFORMANCE
GG 900
visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER BOWL
WPG
GH
GGH10137

VANES TYPE MAT’L VANE O MAT’L


3 CLOSED METAL 915 METAL
1210GH15
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
GLAND SEALED PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE

Last Issue: April 2002


MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER 210 mm
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 700 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

90

700
40%
80 r/min 50%
60%

70%
650
70 73%

600 70%
60
H (m)

550
50

500
40

450

30
400

Reference Test: Curve Redrawn


350
20

10

0
0 100 200 300 400 500 600 700 800 900
Q (l/sec)
12
700
r/min
8
NPSH (m)

4
Revision: 0

350