You are on page 1of 2

Project Job Ref.

Structure Sheet no.


Page 1/2
Calc. by Date Chk'd by Date App'd by Date
LEGION 8/28/2023 8/22/2023 8/22/2023

Slab: S 1, Panel: TOP SLAB


Static & RSA Design Summary
Reinforcement Design Summary
Reinforcement Layer Reinforcement Provided Area Provided Area Required Utilization
[mm2/m] [mm2/m]
Bottom-X H8-175.0-B2 286 146 0.512
Bottom-Y H8-175.0-B1 286 127 0.445
Top-X H10-175.0-T2 451 268 0.594
Top-Y H10-200.0-T1 395 219 0.553

Static & RSA Design Calculations


Reinforcement Design Details
Bottom-X
Summary
Utilization ratio As,reqd / As,prov = 0.512
Analysis method FE chase-down
Critical combination 1 LOAD COMBINATION

Pass

Moment Capacity Check


As,prov X Bottom 286 mm2/m
MdX Bottom -5.728 kNm/m
As,req X Bottom 146 mm2/m
Utilization ratio As,reqd / As,prov = 0.512

Pass

Limiting Reinforcement Parameters Checks


Check Minimum Diameter Pass
Check Maximum Diameter Pass
Check Minimum Bar Distance Pass EN 1992-1-1:2004 Section 8.2(2)
Check Maximum Spacing Tension Bars Pass EN 1992-1-1:2004 Section 9.3.1.1(3)
Check Minimum Area of Reinforcement Pass EN 1992-1-1:2004 Sections 9.2.1.1(1) and 7.3.2(2)
Check Maximum Area of Reinforcement Pass EN 1992-1-1:2004 Section 9.2.1.1(3)

Bottom-Y
Summary
Utilization ratio As,reqd / As,prov = 0.445
Analysis method FE chase-down
Critical combination 1 LOAD COMBINATION

Pass

Moment Capacity Check


As,prov Y Bottom 286 mm2/m
MdY Bottom -5.368 kNm/m
As,req Y Bottom 127 mm2/m
Utilization ratio As,reqd / As,prov = 0.445

Pass

Limiting Reinforcement Parameters Checks


Check Minimum Diameter Pass
Tekla Structural Designer, version: 23.2.0.79
Project Job Ref.

Structure Sheet no.


Page 2/2
Calc. by Date Chk'd by Date App'd by Date
LEGION 8/28/2023 8/22/2023 8/22/2023

Check Maximum Diameter Pass


Check Minimum Bar Distance Pass EN 1992-1-1:2004 Section 8.2(2)
Check Maximum Spacing Tension Bars Pass EN 1992-1-1:2004 Section 9.3.1.1(3)
Check Minimum Area of Reinforcement Pass EN 1992-1-1:2004 Sections 9.2.1.1(1) and 7.3.2(2)
Check Maximum Area of Reinforcement Pass EN 1992-1-1:2004 Section 9.2.1.1(3)

Top-X
Summary
Utilization ratio As,reqd / As,prov = 0.594
Analysis method FE chase-down
Critical combination 1 LOAD COMBINATION

Pass

Moment Capacity Check


As,prov X Top 451 mm2/m
MdX Top 10.198 kNm/m
As,req X Top 268 mm2/m
Utilization ratio As,reqd / As,prov = 0.594

Pass

Limiting Reinforcement Parameters Checks


Check Minimum Diameter Pass
Check Maximum Diameter Pass
Check Minimum Bar Distance Pass EN 1992-1-1:2004 Section 8.2(2)
Check Maximum Spacing Tension Bars Pass EN 1992-1-1:2004 Section 9.3.1.1(3)
Check Minimum Area of Reinforcement Pass EN 1992-1-1:2004 Sections 9.2.1.1(1) and 7.3.2(2)
Check Maximum Area of Reinforcement Pass EN 1992-1-1:2004 Section 9.2.1.1(3)

Top-Y
Summary
Utilization ratio As,reqd / As,prov = 0.553
Analysis method FE chase-down
Critical combination 1 LOAD COMBINATION

Pass

Moment Capacity Check


As,prov Y Top 395 mm2/m
MdY Top 9.137 kNm/m
As,req Y Top 219 mm2/m
Utilization ratio As,reqd / As,prov = 0.553

Pass

Limiting Reinforcement Parameters Checks


Check Minimum Diameter Pass
Check Maximum Diameter Pass
Check Minimum Bar Distance Pass EN 1992-1-1:2004 Section 8.2(2)
Check Maximum Spacing Tension Bars Pass EN 1992-1-1:2004 Section 9.3.1.1(3)
Check Minimum Area of Reinforcement Pass EN 1992-1-1:2004 Sections 9.2.1.1(1) and 7.3.2(2)
Check Maximum Area of Reinforcement Pass EN 1992-1-1:2004 Section 9.2.1.1(3)