Bolted Connection Check For Corrugated Sheets
The first part of this section is for vertical seams which will give the
allowable hoop stress for the gauge and bolt configuration used.
The sheet does not check the following:
Slotted holes
Welds
Double shear sheets
1. Input Data:
Flat sheet connection (input "Yes" or "No"):
(as shown above) FlatSheet "Yes"
Thickness of thinnest part in contact with head and nut: t 2 .158in 0.316in
7
Edge distance measured in line with force from center ev in
of bolt hole to the end of the connected part: 8
7
Edge distance measured perpendicular to line of force eh in
from center of bolt hole to the edge of the part: 8
6
Nominal bolt diameter d in 0.375in
16
Washers are provided under both head and nut: Washer=2
Only one or no washer is provided: Washer=1
For single shear: =1
For double shear: =2 ShearFace 1
Bolt ASTM number (A307, A325, A354, A449, A490): ASTM_NO "A354"
Rupture Inputs
Total gross length of failure path subject to tension (failure
path or projection that is perpendicular to force): Lt 46 in
d 0.375in
b Icor
s 2.156in
No_blt
SumSv2
b Icor No_blt d h
An
4 s h tmin
NoBltRow
2. Minimum Edge Distance and Bolt Spacing Requirement (Section E4.1 & E4.2):
b Icor
s 2.156in
No_blt
dh
min eh s h
2
dh
min eh s h
2
s v 2.5 d
evm in 1.5d
ehm in 1.5d
Fu
1.08
Fy
E3.1 .6
E3.3.1 .6
d (Table E3.3.1-1)
COutSht 3.0 if 10
t
COutSht 4 0.1
d d
if 10 t 22
t
COutSht 1.8
vblt .65
d
Usl 2.5 if Washers 0
s
d
Usl 3.33 if ( Washer 2)
s
Usl 1
E6.2 .65
2
Agt Lt t Icor 15.117in