You are on page 1of 1

LEGEND

.................... PVC WASTE WATER


.................... G.S.P.FOR HOTE WATER
.................... GATE VALVE
FIRST FLOOR .................... ONE WAY VALVE
GROUND FLOOR SCALE 1:50 ∅50 to vent cup & ∅
110 to below S-1
.................... G.S.P FOR COLD WATER
SCALE 1:50 ∅25 from water tank H.W .................... HAND WASH BASIN
W.C .................... LOW FLUSH WATER CLOSET
∅50 to vent cup & ∅ A B & ∅ 25 to below W1 C
A ∅50 to vent cup & ∅ B 110 to below S-1 C ∅50 to vent cup & ∅ 700
K.S ....................KITCHEN SINK
110 to below S-2 110 to below S-2 B.T ....................BATH TUB
F.D ....................FLOOR DRAIN
∅25 from water tank
M.H ....................MANHOLE
MH 3 MH 2 MH 1 & ∅ 25 to below W2
W.H .................ELECTRIC WATER HEATER
F/A ....................FROM ABOVE
1 1 T/B ....................TO BELOW
D/P .....................DOWN PIPE
& ∅ 25 to below W3

SH. .....................SHOWER

& ∅ 25 to below W3
∅25 from water tank

∅25 from water tank


KITCHEN ROOM M.BATH & TOILET
LND. ...................LAUNDRY
CERAMIC TILES FF.
A=6.5m2
DINNING ROOM CERAMIC TILES FF.
A=5m2 CP. ....................CONCRETE PIPE
CERAMIC TILES FF.
+0.00 A=7m2 +660.00
+0.00
CH.BED ROOM
CERAMIC TILES FF.
A=7m2
+330.00

NOTE
THIS DRAWING IS TO BE READ IN CONJUNCTION
MH 4
WITH ALL RELEVANT ARCHITECTS AND ENGINEERS
WH
2 2 DRAWINGS AND SPECIFICATIONS.

PIPES SHOULD BE LAID AS PER THE FOLLOWING


∅50 to vent cup & ∅

∅50 to vent cup & ∅


LOBBY
S-3

110 to below S-3


935
CERAMIC TILES FF.
A=6m2
SLOPE
+0.00
M.BED ROOM
110 to below

CERAMIC TILES FF.

Provide a minimum of 2.5% slope for Ø50 horizontal


A=16m2
+660.00
LIVING ROOM
CERAMIC TILES FF.
A=14m2 drainage pipes.
+0.00
Provide a minimum of 1.50% slope for Ø65 horizontal
1250

drainage pipes.
Provide a minimum of 1.25% slope for Ø110
horizontal drainage pipes.
Provide a minimum of 0.85% slope for Ø150
GUEST BED ROOM
CERAMIC TILES FF.
horizontal drainage pipes.
A=6m2
+0.00 CH.BED ROOM
CERAMIC TILES FF.
A=6m2
Provide a minimum of 0.65% slope for Ø200
+330.00
horizontal drainage pipes.
MH 5
3 3 ALL PIPE DIAMETERS ARE IN MILLIMETERS UNLESS
OTHERWISE STATED
170

400
200

50
200

A A
50

400

800

400

Ø25From Roof Ø25From Roof Ø25From Roof


Water Tank Water Tank Water Tank
200

WATER TANK

TWO TYPICAL DETAIL OF WATER TANKER PLAN


SCALE 1:25
Schematic Diagram
20 m3 capacity water tank
450 DIA. SECURELY FIXED SCREENED AIR INLET WITH
ACCESS/INSPECTION MANHOLE CORROSION RESISTANT MESH.
COVER. (0.65mm MAX. OPENING) 25 DIA.
STORAGE TANK
OVERFLOW
ROOF
100mm WARNING PIPE

400
25 DIA. INLET MESH SCREEN TO
MAINS COLD PREVENT INGRESS
WATER SUPPLY OF INSECTS ETC.
200

+16.90m From 100mm 125mm

Ground Floor 20 DIA. DRAIN 25 DIA.


COLD WATER OUTLET
CONNECTION
Ø to Gravity Distribution
BATH
Ø
Ø

WC
WC
Ø
Ø
1st FLOOR

Ø
Ø

S.K.

WC Ø

GROUND FLOOR
30

30

30

ROOF ROOF ROOF


ROOF
To vent cap

To vent cap

To vent cap

TYPICAL SECTION OF MAN HOLE


FOR WASTE WATER

150
1st FLOOR
Ø

Ø
Ø

To vent cap
Ø

Ø
Half concrete pipe open channel
Sc.1:10
300
MH 2 MH 4
MH 1
Ø

GROUND FLOOR
Ø

b DessiePiasa
Seid Yasin Building
Project:-
Stone Fourth Floor
Stone office number 415
G+1 RESIDENCE(TYPE ONE)
150mm
red ash TYPE
NEW MODIFICATION AS BUILT
Half concrte mayaarchitects669@gmail.com

pipe mame8051@gmail.com
LOCATION: dessie-gerado-kebele 015
b=250 initial and as per the slope OWNER: lemenor begara housing union
0910134304
0914738717

www.mayaarchitects360.com Designed by mohammed ali PAR/22777

Cad by
Checked by
MAYA CONSULTING Approved by
ARCHITECTS AND ENGINEERS Dr. Number
Drawing Title site plan
A NEW VISION OF ARCHITECTURE AND DESIGN
scale 1:200 Date
SN
1:400 2023