Fresh concrete
T (°C) temperature directly 20 °C
after concreting
h (m) Pouring height 2.35 m
Results
Characteristic value of the
CCP max
maximum possible lateral 53 kPa
(kPa)
pressure
hs (m) Hydrostatic pressure head 2.10 m
Notes
Equation 4.2.2.1b(b) used for calculation (ACI 347R-14)
(IV) Cement blends containing less than 70% slag and less than 40% fly ash with retarder
CC = 1.4 (V) Cement blends containing more than or equal to 70% slag or more than or equal to 40% fly
ash without retarder
(VI) Cement blends containing more or equal than 70% slag or more than or equal to 40% fly ash
CC = 1.5 with retarder
List of concrete types
You can find the accepted Terms of Use for PERI Applications by clicking on the following link:
https://apps.peri.com/core/views/media/pdfs/en_tc.pdf