You are on page 1of 3

FERMES DE BUTONNAGE

Les fermes de butonnage transfèrent aux fonda ons la pression de bétonnage des éléments coffrés
sur une face unique. Celles-ci peuvent être u lisées avec tous les systèmes de coffrage de voiles.

En cas de bétonnage une face contre des parois rocheuses, la pression maximale de bétonnage
exercée sur la surface du coffrage doit être transférée par le soubassement via un système de fermes
de butonnage correctement ancré.

Les charges admissibles pour les applica ons standards figurent dans le tableau ci-dessous
Formwork Load Calculator | Results
based on DIN 18218:2010-01

Boundary Conditions Legend


Consistency class F4 Input value
tE (h) End of setting tE at TC,Ref 7h Output value
Fresh concrete temperature which is
TC,Ref (°C) the basis for the determination of the 15 °C
end of setting tE
Fresh concrete temperature
TC,placing (°C) directly after 20 °C
concreting
Lowest concrete temperature up to tE 20 °C

H (m) Pouring height 2.70 m

Results
Characteristic value
σ hk, max
of the maximum possible 37.0 kN/m²
(kN/m²)
fresh concrete pressure
hs (m) Hydrostatic pressure head 1.48 m

t (h) Minimum pouring time 2.7 h

n (m/h) Maximum rate of rise 1.00 m/h

Please pay attention:


The illustrations and icons are understood to be system representations only. The additionally required
access and safety equipment for the use of this formwork system in accordance with the regulations are
to be taken from the corresponding assembly instructions.
The assembly instructions provide a basis for the project related risk assessment and the procedures for
the preparation and use of the formwork system by the company.
They do not replace however the latter.

This application is based on the following documents:


DIN 18218:2010-01 Pressure of fresh concrete on vertical formwork.
DIN 18202:2013-04 Tolerances in building construction - Buildings.
Performance data of the formwork systems PERI MAXIMO, TRIO and DOMINO, which have to be taken
from the assembly and usage instructions for the formwork systems PERI MAXIMO, TRIO and DOMINO.
The regulations and conditions of the valid standards are always applicable.

Notes