You are on page 1of 2

IMPORTANT NOTES

All dimensions are in millimitres and all levels


are in metres, unless stated other wise.

FOUNDATIONS AND WALLS


MEMBER SIZES 1. Foundations to be founded on firm ground
and to be approved by the Engineer prior
TOP+BOT = 50X50X6L to casting of concrete. Minimum depth to
be 1500 mm.
VERT+DIA = 40X40X6L 2. All foundation trenches to be back filled
with granular material.
3. Minimum strength of wall material to be
as follows:-
Concrete Block=3.5 MPa, SSB = 5.5 MPa.
4. Brickforce to be provided as follows:-
4960 Concrete Block - Every 2nd course
SSB - Every 3rd course.
5. Brickforce under windows every 2nd course
35

1490
with 400 mm overlap either way.
16 0

320
140

1100
CONCRETE
1245 6. Structural reinforced concrete to be:

710
Mass concrete = 15/40, Bases & Columns
= 30/20, Beams & Slabs = 25/20

18°
7. Structural concrete shall be cured for a
minimum of 28 days.

REINFORCING STEEL
985 1200 1200 1200 1200 1200 1200 985 8. Rebar notation shall be as follows:-
Y = High yield deformed bar
R = Mild steel round bar
9. Minimum lap length of re-bars to be 45Ø
9175 10. Cover to the outermost layer of re-bars
shall be as follows:-Base bottom =75 mm,
T1 (4No.) Base sides = 50 mm, Columns = 30 mm,
1:50 Slabs and Beams = 20 mm

ROOF STRUCTURE
11. Steelwork to be grade 43, All weld to be
6mm continuos fillet weld, All bolts to be
10400 grade 4.6 unless otherwise stated

12 Prime coat to be patch primed prior to


5790 4610 final painting on site

13. All levels and dimensions to be confirmed


6rows Steel Purlins on site prior to fabrication of roof trusses.
76X38X2.5 RHS @905 c/c
14. READ THIS DRAWING IN
CONJUNCTION WITH THE RELEVANT
ARCHITECTURAL AND STRUCTURAL
DRAWINGS

4095
4000

SUB. NO. DATE DESCRIPTION


4800

Steel Trusses (4No.) CLIENT :

@3300 c/c
T1

T1

T1

T1
JEHOVAH WITNESS OF MALAWI
P.O BOX 30749
LILONGWE 3

FUNDED BY :
3200

CONSULTANT :

PROJECT DESCRIPTION:
MALAWI BRANCH
EXPANSION - SCHOOL
CAMPUS AND RESIDENCE PROJECT

6rows Steel Purlins SHEET DESCRIPTION:


76X38X2.5 RHS @905 c/c ROOF STRUCTURE LAYOUT PLAN
RESINTIAL TYPE A

Scale As shown Local Authority


ROOF STRUCTURE LAYOUT PLAN(RESIDENTIAL TYPE A)
GENERAL ARRANGEMENT Drawing Date 2023

SCALE 1:75 Designed by R.F.M Drawing No. ENG-01

Drawn by A. M Revision.

Approved by R.F.M Plot Date : FEB. 2023


IMPORTANT NOTES
All dimensions are in millimitres and all levels
are in metres, unless stated other wise.

FOUNDATIONS AND WALLS


1. Foundations to be founded on firm ground
and to be approved by the Engineer prior
700 5200 5200 700 to casting of concrete. Minimum depth to
be 1500 mm.
2. All foundation trenches to be back filled
with granular material.
3. Minimum strength of wall material to be
as follows:-
Concrete Block=3.5 MPa, SSB = 5.5 MPa.
4. Brickforce to be provided as follows:-
Concrete Block - Every 2nd course

200
SSB - Every 3rd course.
5. Brickforce under windows every 2nd course
with 400 mm overlap either way.

600 CONCRETE
6. Structural reinforced concrete to be:
Mass concrete = 15/40, Bases & Columns
= 30/20, Beams & Slabs = 25/20

200
7. Structural concrete shall be cured for a
minimum of 28 days.

REINFORCING STEEL
8. Rebar notation shall be as follows:-
Y = High yield deformed bar
R = Mild steel round bar
9. Minimum lap length of re-bars to be 45Ø
10. Cover to the outermost layer of re-bars
shall be as follows:-Base bottom =75 mm,
Base sides = 50 mm, Columns = 30 mm,
6 Rows 75x50 CFLC Purlins Slabs and Beams = 20 mm
6 Rows 75x50 CFLC Purlins @1100 c/c ROOF STRUCTURE
@1100 c/c 11. Steelwork to be grade 43, All weld to be
6mm continuos fillet weld, All bolts to be
grade 4.6 unless otherwise stated

12 Prime coat to be patch primed prior to


final painting on site
5000

13. All levels and dimensions to be confirmed


on site prior to fabrication of roof trusses.

14. READ THIS DRAWING IN


CONJUNCTION WITH THE RELEVANT
1000 ARCHITECTURAL AND STRUCTURAL
DRAWINGS

SUB. NO. DATE DESCRIPTION


2800

1240

200
CLIENT :

152x76 Rsc rafters


@2440 c/c ..\SMEDI
JEHOVAH LOGO OF
WITNESS 1.png
MALAWI
P.O BOX 30749
LILONGWE 3
600
300

152x76 Rsc rafters (4No.)


@approx. 2460 c/c FUNDED BY :

ROOF STRUCTURE LAYOUT PLAN(RESIDENTIAL TYPE B)


GENERAL ARRANGEMENT CONSULTANT :

SCALE 1:75

PROJECT DESCRIPTION:
MALAWI BRANCH
EXPANSION - SCHOOL
CAMPUS AND RESIDENCE PROJECT

SHEET DESCRIPTION:

ROOF STRUCTURE LAYOUT PLAN


RESINTIAL TYPE A

Scale As shown Local Authority

DOWA DISTRICT COUNCIL


Drawing Date :2023

Designed by R.F.M Drawing No. ENG-02

Drawn by A. M Revision.

Approved by R.F.M Plot Date : FEB. 2023

You might also like