Professional Documents
Culture Documents
Proy - Edif.f - Plano-Prueba Part.2
Proy - Edif.f - Plano-Prueba Part.2
2-12 2-12
1-12t 1-12t
17 COMP.
COMP.
A COMP.
1-12t 1-12t 2-12
C3
C1 2 3
PASE A
549
PASE B
C6 1-14 1-14
1-14
2-12
2-12
1-12t A 2-12
2-12
1-12t
A
1-12t 1-12t
CARGA TOTAL C3
1836 W
A C3
2-12
1-12t
2-12
1-12t
C2
1-14
2-12
1-12t
2-12 2-12
16 AWG 1-12t C3
ALIMENTADOR 14 CAL. 1X30 A. 1-12t
120 V 10 CAL.
0.0604 1.2 %
CARG. TOTAL 9.2 A 8 m. C2
12
1836 W X FD(0.6)
1101.16 W FRE
A 1-14
1-14
2-12
1-12t A FRESADORA FRESADORA
1-14
2-12
2-12
1-12t C2
2-12
1-12t A C2
2-12
1-12t
FRE
1-12t 2-12
DIAGRAMA UNIFILAR C2
1-12t
C. F. E. 2-12
1F-2H
CONTACTOR TRICASICO C1 1-12t
A
INTERRUPTOR TRIFASICO
C1 A 1-14
2-12
1-12t
A
1-14
1-14 C1 2-12
LAMPARA (LIMINARIA) 2-12 1-12t
1-12t C1
C1
tablero C 1- 22mm
26 AMP
Tuberia
Tuberia
subterranea 2-12
1-12t
Acometida M6
C. F. E.
T-21mm
2-10
1-10t
L=8 m
CAJA DE
CONEXION
(Cuchillas)
EQUIPO
M4 M5 M6
1X20 A 1X20 A
e%=1.2%
1X20 A 1X20 A
DE
MEDICION
PUESTA
2 1-14
2-12
1-12t
1-14
5HP 5HP 5HP
2-12 2-12 2-12 2-12 TUBERIA 2-12
PARA BOTON 1-12t
1-12t 1-12t 1-12t 1-12t O PARO DE PASILLO
L=8 m L=11 m L=15.3m L= EMERGENCIA
20.5m M5
e%=0.33 e%=0.44 e%=0.60
BOTON O
e%=0.27 PARO DE
EMERGENCIA 1-14
2-12
1-12t
C1 C2 C3 C4
DIAGRAMA UNIFILAR EDIFICIO F M1
549 W
4.5 A
549 W
4.5 A
549 W
4.5 A
189 W
1.5 A Acometida
C. F. E. M1 M2 M3
1F-2H
ACCESO 3
1-14
5HP
T-22mm
1-12
CROQUIS DEL LUGAR
26 Amp M1
MATERIALES T-21mm
2-10
No. DESCRIPCION MARCA 1-10t 1-14
Tablero C L=8 m 2-12
1-12t
Tablero de distribución 6 circuitos Square D QOD-6 e%=1.72%
1
100 A, 250 V 1X20 A
1X20 A 1X20 A 1X20 A 1X20 A 1X20 A 1X20 A 1X20 A
1X20 A 1X20 A 1X20 A 1X20 A
Interruptor termomagnetico tipo Square D 1-14
2 QO 3 polos 20 Amperes 2-12 M2
M3
1-12t
2-12
1-12t T-16mm T-16mm T-16mm T-16mm CONTACTOR TRICASICO
PROYECTO: INSTALACIONES ELECTRICAS EDIFICIO F
BOTON DE EMERGENCIA L=10 m
e%=1.3 T-16mm T-16mm T-16mm T-16mm
2-12 2-12
1-12t
2-12
1-12t
2-12 T-16mm
2-12
T-16mm
2-12
T-16mm
2-12
1-12t 1-12t
L=12 m 1-12t LAMPARA (LIMINARIA)
2-12 2-12 2-12 2-12 L=22 m L=15 m L=12 m 1-12t 1-12t
M1 1-12t 1-12t 1-12t 1-12t e%=1.6 e%=1.19 e%=1.48 e%=1.19 L=17.5m L=17.5m L=12 m
CALVE DE
VOLTAJ L=6 m L=16 m L=16 m L= 27m e%=1.2 e%=1.2 e%=1.19 tablero C INSTALACION
5 CP
e%=0.38 e%=0.95 PLANO: PLANO:
TIPO AMP 3.75 KW
e%=0.9 e%0=0.8 M6 M7 M8 M9 M10
Tuberia
ELECTRICA F08-CC-01
E 15.2 A
M2
Tuberia
subterranea
M3 M4 M5 7.5 CP 7.5 CP 5 CP 5 CP
5 CP
3.75 KW
5.6 KW 5.6 KW 3.75 KW 3.75 KW
Acometida
C. F. E.
ESCALA: 1:75 NUMERO DE
Botón, 22 26 AMP 500V 5 CP 5 CP 5 CP 15.2 A
22 A 22 A
3X30 A
15.2 A 15.2 A ACOTACION: METROS PLANO: 12 / 15
5 CP CAJA DE
3.75 KW
mm 15.2 A
3.75 KW
15.2 A
3.75 KW
3.75 KW TR ALUMBRADO
3X30 A
CONEXION PROPIETARIO: INSTITUTO TECNOLOGICO DE UBICACION: AV. INSTITUTO
TZOMPANTEP
15.2 A (Cuchillas) APIZACO TECNOLOGICO S/N
Siemens 15.2 A 220V/127V
15KVA
TR ALUMBRADO
220V/127V EC, APIZACO
EQUIPO
3SU1150-1 15KVA DE
MEDICION
BA20-1CA0
PUESTA
ATIERRA PROYECTO: JOSE JESUS SALDAÑA LOPEZ FECHA: 5 JUNIO 2023
TUBERIA
PARA BOTON ELABORACION DEL DIBUJO: JOSE JESUS
O PARO DE SALDAÑA EZ
EMERGENCIA
BOTON O
PARO DE
EMERGENCIA