FORMATE NO: RIS/SIR/010-REV.

01
RIKSONS CUSTOMER / SUPPLIER DATE : 8-Mar-24
INSPECTION
SERVICES INSPECTION REPORT INSPECTOR NAME: ANSAR MULLA
REPORT NO: AM-129
CUSTOMER: AR Wilfely India Pvt Ltd
SUPPLIER : The Sky Industries, Tilawni-Kolhapur
HEAT No.: PART NO- TSI/WILFELY/23/BF/44 -MAR
PART DETAILS : A9-MS BASE FRAME 398 DRG. NO: ZBPA9398-315SM-MS REV.00
PO NO / LINE : 2224/SKY/1 LN 4 GRADE : MS IS 2062 Gr. A
OFFER INSPECTED ACCEPTED REWORK REJECT
PO QTY. REASON FOR REWORK / REJECTION
QTY QTY. QTY. QTY. QTY.
3 2 2 - 2 - Dimensional; fillet weld leg size rework

Inspection Summery / details as below,


# Rework Points / General Comments / Visual Rework Point :- REMARK
1. Depth 53 [-1.0] is observed as 1) 50.70/52.24 ; 2) 51.35/ 52.2 Rework
2. 4x 26 drill hole for foundation missing at channel top side of one base Rework
3. Fillet Weld- leg size 10 mm required actual observed 6-7 mm at found pump & motar base pad Rework
4. Documents Reviewed - MTC Balance
5. Visually Checked & found satisfactory Acc
6. GD & T not offered during Inspection FYI
7. After welding leg rework , Re-check again rework related area of dimension Re-check

# DEVIATION POINTS / CONCESSION REQUEST:- REMARK

NIL

TICK AS ''√ '' > √


FINAL INSPECTION REMARKS :
UNDER REWORK UNDER DEVIATION CLEARED FOR DISPATCH

CUSTOMER / SUPPLIER QA FOR RIKSONS INSPECTION SERVICES