Network DIRIS Am
DIRIS A40 analysis DIRIS A20
L
DIRIS A40 / DIRIS A41
DIRIS A41 Communication interfaces
DIRIS VISION software
CONTROL VISION software
BILLING APPLICATION software
Functions
DIRIS A40 and A41 are multi-function
meter for measuring the extent of
electrical values for all LV/HV networks.
They allow starting from the front panel
to configure and display all the electric
parameters and to exploit the functions
of measurement, metering and energies
management, harmonics analysis, remote
control and control state of control
devices, communication and detection
of high voltages, peaks and voltage
disconnections.
In addition, DIRIS A40 and A41 have
a function for correcting connection errors.
Conformity to standards
• IEC 62053-22 class 0.5 S
diris_561_b_3_x_cat
Applications
Using electrical parameters means using - frequency, instantaneous, average and
several analogue or digital single-function maximum over a programmable period,
products such as ammeters, voltmeters or - active power on 4 quadrants (±)
wattmeters. per phase and total in instantaneous,
DIRIS A40 and A41, with their six direct average and maximal values over
Diris A40 access keys keyboard and LCD display, a programmable period,
allow exploiting all the parameters of a LV - reactive power on 4 quadrants (±)
RS485
and HV installation. These parameters may per phase and total in instantaneous,
be centralized on a PC or an automaton average and maximal values over
through an RS485 link using a programmable period,
Diris A41 JBUS/MODBUS® or PROFIBUS ® DP - apparent power per phase and total
485
protocol. The casing allows the installer in instantaneous, average and maximal
Main
232 meter panel easily fit DIRIS A40 or A41 panel board. To values over a programmable period,
PLC facilitate and optimize the operator’s work,
- power Factor (PF) per phase and total
DIRIS A40 and A41 use one of the most
with inductive or capacitive indication,
functional principles for integrating
PC Currents communications, metering, harmonics, - harmonic distortion rate (THD) up to 51
per phase
on phase-to-neutral and phase-to-phase
diris_581_a_1_gb_cat
CON
ciel
de
supe
TRO
rvisi
L VISI
on
DIR
ON
et
CO
®
UN
TIS
1
®
This document is not a contract. SOCOMEC reserves the right to modify features
B. 54 without prior notice in view of continued improvement. 2008 - 2009
SOCOMEC general catalogue
Services + Energy management
> Audit
DIRIS A40 / DIRIS A41
picto_108_a_gb
> Setting up
> Training
See page IV
Plug-in modules
Pulse outputs
2 pulse outputs able for configuration (type, weight and run) on ± kWh, ± kvarh and kVAh.
diris_445_a_1_cat
DIRIS® A40
diris_446_a_1_cat
Spectral analysis of harmonics by range and by phase for 3I, In, 3V and 3U up to range 25.
diris_563_a_1_cat
Analogue outputs
diris_564_a_1_cat
2 outputs able for configuration on 3I, In, 3V, 3U, F, ±ΣP, ±ΣQ, ΣS, ΣPFL/C and 30 VDC
diris_448_a_1_cat
power supply.
2 modules may be connected at maximum, that is 4 analogue outputs.
2 inputs - 2 outputs
2 outputs assignable for the control of 3I, In, 3V, 3U, F, ±ΣP, ±ΣQ, ΣS, ΣPFL/C, THD 3I,
diris_449_a_1_cat
THD In, THD 3V, THD 3U and of the hour meter (storing of the 3 last alarms) or to the remote
control. 2 inputs for pulses metering. 3 modules may be connected at maximum, that is 6
inputs / outputs.
Memory
• Storing maximum over 62 days of P+, P-, Q+, Q- with an internal or external
diris_682_a_1_cat
Accessories
diris_720_a
diris_718_a
This document is not a contract. SOCOMEC reserves the right to modify features
SOCOMEC general catalogue without prior notice in view of continued improvement. 2008 - 2009
B. 55
Energy management
Network DIRIS Am
DIRIS A40 analysis DIRIS A20
L
DIRIS A40 / DIRIS A41
DIRIS A41 Communication interfaces
DIRIS VISION software
CONTROL VISION software
BILLING APPLICATION software
References
diris_561_b_2_cat
DIRIS A40 DIRIS A41
Basic device 4CT inputs (not UL/CSA)
Auxiliary power supply Us References e HT References e HT
110 … 400 VAC / 120 … 350 VDC (IEC) - 110 … 240 VAC / 120 … 250 VDC (UL/CSA) 4825 0A40 671,00 4825 0A41 996,00
12 … 48 VDC (not UL/CSA) 4825 1A40 842,00 4825 1A41 1 104,00
Optional plug & display modules
Plug-in modules (1)
Pulse outputs 4825 0090 82,80 4825 0090 82,80
Pulse outputs and harmonics 4825 0091 171,00 4825 0091 171,00
RS485 JBUS / MODBUS® communication 4825 0092 154,00 4825 0092 154,00
Analogue outputs 4825 0093 103,00 4825 0093 103,00
2 inputs - 2 outputs 4825 0094 134,00 4825 0094 134,00
RS485 PROFIBUS® DP communication 4825 0096 342,00 4825 0096 342,00
Memory 4825 0097 325,00 4825 0097 325,00
Accessories
IP65 protection cover (not UL/CSA) 4825 0089 44,00 4825 0089 44,00
Fitting kit for 144 x 96 mm cut out (not UL/CSA) 4825 0088 0,00 4825 0088 0,00
(1) Ease of integration for additional functions (maximum 4 on A40 and 3 on A41) by clutchable modules on the rear of the device, by the user at any moment.
Terminals
• DIRIS A40
V1 V2 V3 VN A U X
diris_569_a_1_x_cat
S1 S2 S1 S2 S1 S2
S1 - S2: current imputs
I1 I2 I3 AUX: auxiliary power supply Us
V1 - V2 - V3 - VN: voltage inputs
DIRIS A40
• DIRIS A41
V1 V2 V3 VN A U X
diris_570_a_1_x_cat
S1 S2 S1 S2 S1 S2 S1 S2
S1 - S2: current imputs
I1 I2 I3 IN
AUX: auxiliary power supply Us
V1 - V2 - V3 - VN: voltage inputs
DIRIS A41
0V - + 1 2 3 4 5 6 7 8
diris_571_a_1_x_cat
diris_572_a_1_x_cat
diris_573_a_1_x_cat
1
0n + - + -
RS485 R = 120 Ω 0/4-20 mA 0/4-20 mA
OUT 1 OUT 2
OUT 1 OUT 2
DIRIS A40 / A41 DIRIS A40 / A41 DIRIS A40 / A41
9 10 11 12 17 18
diris_683_a_1_x_cat
+ -
OUT 1 OUT 2
IN
A-Cd A-Cd
synchro
diris_574_b_1_x_cat
This document is not a contract. SOCOMEC reserves the right to modify features
B. 56 without prior notice in view of continued improvement. 2008 - 2009
SOCOMEC general catalogue
Energy management
DIRIS A40 / DIRIS A41
Electrical characteristics
Current measurement on insulated inputs (TRMS) Auxiliary power supply
CT primary 10 000 A AC voltage (IEC) 110 … 400 VAC
CT secondary 1 and 5 AC voltage (UL/CSA) 110 … 240 VAC
Measurement range 0 … 11 kA AC tolerance ± 10 %
Input consumption ≤ 0.1 VA DC voltage (IEC) 120 … 350 VDC / 12 … 48 VDC
Measurement updating period 1s DC voltage (UL/CSA) 120 … 250 VDC
Accuracy 0.2 % DC tolerance ± 20 % / - 6 … + 20 %
Sustained overload 6A Frequency 50 / 60 Hz
Intermittent overload 10 In for 1 s Consumption ≤ 10 VA
This document is not a contract. SOCOMEC reserves the right to modify features
SOCOMEC general catalogue without prior notice in view of continued improvement. 2008 - 2009
B. 57
Energy management
Network DIRIS Am
DIRIS A40 analysis DIRIS A20
L
DIRIS A40 / DIRIS A41
DIRIS A41 Communication interfaces
DIRIS VISION software
CONTROL VISION software
BILLING APPLICATION software
Overall dimensions
92 +- 0,8 Type panel mounting
0,0
Dimensions W x H x D 96 x 96 x 60 mm
Case protection rating IP30
Front protection rating IP52
Display type LCD
Terminal block type fixed or pull-out
Voltage and other connection section 0.2 … 2.5 mm2
Current connection section 0.5 … 6 mm2
96 92 +- 0,8
diris_582_b_1_x_cat
0,0
Weight 400 g
20
60
96
Connections
Recommendation: when disconnecting the DIRIS, the secondaries of each current transformer must be short-circuited.
This operation can be carried out automatically from a product in the SOCOMEC catalogue, PTI, please consult us.
1 1 1 1 1 1 1 1
diris_392_c_1_gb_cat
diris_393_c_1_gb_cat
diris_394_c_1_gb_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
• 3/4 wires with 3 CTs • 3 wires with 2 CTs • 3 wires with 2 CTs
1 = Fus. 0.5 A gG / BS88 2 A gG / 0.5 A CC Class 1 = Fus. 0.5 A gG / BS88 2 A gG / 0.5 A CC Class 1 = Fus. 0.5 A gG / BS88 2 A gG / 0.5 A CC Class
N P1 P1
P1
L1 L1
L1 S1 S2 S1 P1
S1 S2 L2 L2
L2 P1 S1 S2
P1
L3 L3
L3 S1 S2
S1 S2
1 1 1 1 1 1
1 1 1
diris_395_c_1_gb_cat
diris_396_c_1_gb_cat
diris_397_c_1_gb_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
The use of 2 CTs reduces by 0.5 % the accuracy of the The use of 2 CTs reduces by 0.5 % the accuracy of the
phase whose current is determined by vector calculation phase whose current is determined by vector calculation
This document is not a contract. SOCOMEC reserves the right to modify features
B. 58 without prior notice in view of continued improvement. 2008 - 2009
SOCOMEC general catalogue
Energy management
DIRIS A40 / DIRIS A41
Connections
Low voltage unbalanced network for DIRIS A41
L
1 1 1
diris_575_b_1_gb_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 S1 S2
I1 I2 I3 IN
Other information
L
• Communication via RS485 link • Voltage transformer connection • AC & DC auxiliary power supply
for HV networks
110 / 400 VAC (IEC)
120 / 350 VDC (IEC)
L1
L2 110 / 240 VAC (UL/CSA)
120 / 250 VDC (UL/CSA)
L3 or
12-48 VDC (IEC)
LIYCY-CY
diris_400_e_1_gb_cat
diris_399_b_1_x_cat
diris_398_c_1_x_cat
0V - + A U X
V1 V2 V3 N
ON
RS485
This document is not a contract. SOCOMEC reserves the right to modify features
SOCOMEC general catalogue without prior notice in view of continued improvement. 2008 - 2009