Technical Information Series 51 and 51-1 Bent Axis Variable Displacement Motors
Contents
General description
Sectional view
Series 51-1, two-position control................................................................................................................................................7
Series 51, proportional control.................................................................................................................................................... 8
System circuit description
Pictorial diagram...............................................................................................................................................................................9
System circuit diagram...................................................................................................................................................................9
Technical specifications
General specifications.................................................................................................................................................................. 10
Specific data.....................................................................................................................................................................................10
Fluid specifications........................................................................................................................................................................11
Determination of nominal motor sizes.................................................................................................................................. 11
General technical specifications
Case pressure...................................................................................................................................................................................13
Speed range.....................................................................................................................................................................................13
Pressure limits................................................................................................................................................................................. 13
Loop flushing...................................................................................................................................................................................14
Minimum displacement limiter................................................................................................................................................ 15
Hydraulic fluids............................................................................................................................................................................... 16
Temperature and viscosity......................................................................................................................................................... 16
Fluid and filtration......................................................................................................................................................................... 17
Independent braking system.................................................................................................................................................... 17
Reservoir............................................................................................................................................................................................17
Motor bearing life.......................................................................................................................................................................... 18
External shaft loads....................................................................................................................................................................... 18
External shaft load orientation..................................................................................................................................................19
Allowable external shaft load, when shaft load distance is different from standard............................................20
Efficiency graphs and maps....................................................................................................................................................... 20
Speed sensor................................................................................................................................................................................... 22
Typical control and regulator applications
Typical control and regulator applications...........................................................................................................................24
Controls circuit diagram – nomenclature – description
Hydraulic two-position control – option N1NN for 51-1 frame size 060, 080, 110.................................................25
Hydraulic two-position control N1NN.............................................................................................................................. 25
Control pressure........................................................................................................................................................................25
Hydraulic two-position control – option HZB1 for 51 frame size 160, 250............................................................... 26
Hydraulic two-position control HZB1................................................................................................................................27
Control pressure........................................................................................................................................................................27
Pressure compensator control – options TA** for 51-1 frame size 060, 080, 110.................................................. 27
Pressure compensator control TA**.................................................................................................................................. 28
Pressure Compensator Configuration: TACA with Hydraulic Brake Pressure Defeat...................................... 28
Pressure Compensator Configuration: TAD1, TAD2, TAD7 with Electric Brake Pressure Defeat.................29
Solenoid Connectors............................................................................................................................................................... 29
Pressure Compensator Configuration: TAC2 without Brake Pressure Defeat.................................................... 29
Pressure Compensator Control – Options TA** for 51 Frame Size 160, 250.............................................................30
Pressure Compensator Control TA**................................................................................................................................. 30
Pressure Compensator Configuration: TAC0 with Hydraulic Brake Pressure Defeat.......................................31
Pressure Compensator Configuration: TAC2 without Brake Pressure Defeat.................................................... 31
Hydraulic Two-Position Control – Options TH** for 51-1 Frame Size 060, 080, 110..............................................31
Hydraulic Two-Position Control TH**................................................................................................................................32
Pressure Compensator Override (PCOR)..........................................................................................................................32
Pressure Compensator Configuration: THCA with Hydraulic Brake Pressure Defeat...................................... 32
Pressure Compensator Configuration: THD1, THD2, THD7 with Electric Brake Pressure Defeat................ 33
Solenoid Connectors............................................................................................................................................................... 33
Contents
Contents
General description
Series 51 and 51-1 variable displacement motors are bent axis design units, incorporating spherical
pistons.
These motors are designed primarily to be combined with other products in closed circuit systems to
transfer and control hydraulic power. Series 51 and 51-1 motors have a large maximum / minimum
displacement ratio (5:1) and high output speed capabilities. SAE, cartridge, and DIN flange configurations
are available.
A complete family of controls and regulators is available to fulfill the requirements of a wide range of
applications.
Motors normally start at maximum displacement. This provides maximum starting torque for high
acceleration.
The controls may utilize internally supplied servo pressure. They may be overridden by a pressure
compensator which functions when the motor is operating in motor and pump modes. A defeat option is
available to disable the pressure compensator override when the motor is running in pump mode.
The pressure compensator option features a low pressure rise (short ramp) to ensure optimal power
utilization throughout the entire displacement range of the motor. The pressure compensator is also
available as a stand-alone regulator.
Sectional view
TAPERED
ROLLER BEARINGS
FLANGE
SYNCHRONIZING
SPEED SENSOR SHAFT
SERVO
PISTON PISTON
ELECTROHYDRAULIC
TWO-POSITION CONTROL
CHARGE PRESSURE P001 831E
RELIEF VALVE
Name plate
Neumünster/Germany Ident
number
Model No./Ident. No. 511685
Model
Model Code 51D110-1-RD4N
code E1B1 NNU2 ADD
030AAA3 0000 Serial
number
Serial No. N973212355
Barcode
serial number
Made in Germany
Place of manufacture
P001 832E
511 685
Sectional view
FLANGE
SERVO PISTON
CHARGE PRESSURE P001 196E
RELIEF VALVE
Name plate
Neumünster/Germany Ident
number
Model No./Ident. No. 5084092
Model
Model Code 51V080 RS1N
code L1B1 WB31 ADA
051AAF0 D400 Serial
number
Serial No. N982211215
Barcode
serial number
Made in Germany
Place of manufacture
P001 832E
508 4092
Pictorial diagram
Displacement
Control Handle Control Valve Heat Exchanger
Bypass Valve
Reservoir
Vacuum Gauge
Orificed Check
Valve
Charge Pump
Input Shaft
To Synchronizing Shaft
Multi-Function Valve Motor
Servo Control Case
Pump Swashplate Cylinder
Loop Flushing Relief Valve
Working Loop Working Loop Suction Line Control Fluid Case Drain Fluid P001 175E
(High Pressure) (Low Pressure)
M3 L2 M4 M3 N
A A
M1 M1
n
M4
max.
disp.
M5
T3
T2
T7 T8
T1 M5
M2
B B M2
S L2 L1 X1 M7
SIGNAL PRESSURE SUPPLY
P001 833E
Above schematics show the function of a hydrostatic transmission using a Series 90 Axial Piston Variable
Displacement Pump with manual displacement control (MA) and a Series 51 Bent Axis Variable
Displacement Motor with hydraulic two-position control (HZ).
Technical specifications
General specifications
Most specifications for bent axis variable displacement motors are listed on these pages. For definitions
of the various specifications, see the related pages in this publication. Not all hardware options are
available for all configurations; consult the series 51 and 51-1 model code supplement or price book for
more information.
General Specifications
Motor type Axial piston motor with variable displacement bent axis design.
Direction of rotation Clockwise and counter-clockwise (bi-directional).
Installation position Discretionary, the housing must always be filled with hydraulic fluid.
Other system requirements Independet braking system, circuit overpressure protection, suitable reservoir.
Specific data
Specific Data
Frame size
Dimension 060 080 110 160 250
cm3 60.0 80.7 109.9 160.9 250.0
Displacement maximum Vgmax
[in ]
3
[3.66] [4.92] [6.71] [9.82] [15.26]
cm3 12.0 16.1 22.0 32.2 50.0
Displacement minimum Vgmin
[in ]
3
[0.73] [0.98] [1.34] [1.96] [3.05]
l/min 216 250 308 402 550
Rated flow Q
[US gal/min] [57] [66] [81] [106] [145]
l/min 264 323 396 515 675
Maximum flow Qmax
[US gal/min] [70] [85] [105] [136] [178]
P corner kW 336 403 492 644 850
Maximum corner power
max. [hp] [450] [540] [660] [864] [1140]
kg 28 32 44 56 86
Weight (approx.) m
[lb] [62] [71] [97] [123] [190]
Mass moment of inertia kgm 2
0.0046 0.0071 0.0128 0.0234 0.0480
J
of the internal rotating parts [lb•ft2] [0.1092] [0.1685] [0.3037] [0.5553] [1.1580]
Four (4) bolt flange, SAE or DIN-flange configuration.
Type of mounting
Two (2) bolt flange cartridge motor configuration.
Main pressure ports: SAE-flange.
Pipe connections
Remaining ports: SAE straigt thread O-ring boss.
Controls N1, HZ, E1, E2, E7, F1, F2, T1, T2, TA, TH, EP, EQ, L1, L2, L7, D7, D8, HS
All Series 51 motors incorporate mechanical minimum and maximum
Displacement limiter
displacement limiters.
Shaft configuration Splined ANSI or DIN shaft.
Case pressure
bar [psi]
Rated pressure 3 [44.0]
Maximum pressure (cold start) 5 [73.0]
Minimum pressure (at rated speed) 1 [14.5]
Speed Limits
min-1 (rpm)
Frame size 060 080 110 160 250
at max. disp. 3600 3100 2800 2500 2200
Rated speed
at min. disp. 5600 5000 4500 4000 3400
at max. disp. 4400 4000 3600 3200 2700
Maximum speed1)
at min. disp. 7000 6250 5600 5000 4250
1)
Contact your Sauer-Danfoss representative for max. speed at displacements between
max. and min. displacement.
Technical specifications
Theoretical Torque
Frame size 060 080 110 160 250
At maximum Nm/bar 0.95 1.28 1.75 2.56 3.98
displacement [lbf•in/1000 psi] [583] [784] [1067] [1563] [2428]
At minimum Nm/bar 0.19 0.26 0.35 0.51 0.80
displacement [lbf•in/1000 psi] [117] [156] [214] [313] [486]
Fluid specifications
Temperature range 1)
°C [°F]
Minimum -40 [-40] intermittent, cold start
Rated 104 [220]
Maximum 115 [240] intermittent
1) At the hottest point, normally the case drain port.
Viscosity
mm²/s [SUS]
Minimum 7 [49] intermittent
Recommanded operating range 12-80 [70-370]
Maximum 1600 [7500] intermittent cold start
Technical specifications
Case pressure
Under normal operating conditions, case pressure must not exceed the rated pressure. Momentary case
pressure exceeding this rating is acceptable under cold start conditions, but still must stay below the
maximum pressure rating. The minimum pressure provides proper lubrication at high speeds. Operation
with case pressure in excess of these limits may result in external leakage due to damage to seals,
gaskets, and/or housings.
Case pressure
bar [psi]
Rated pressure 3 [44.0]
Maximum pressure (cold start) 5 [73.0]
Minimum pressure (at rated speed) 1 [14.5]
Speed range
Rated Speed is the speed limit recommended at full power condition and is the highest value at which
normal life can be expected.
Maximum Speed is the highest operating speed permitted and cannot be exceeded without reduction
in the life of the product or risking immediate failure and loss of driveline power (which may create a
safety hazard). In the range between rated and maximum speed please contact your Danfoss
representative.
W Warning
The loss of hydrostatic drive line power in any mode of operation (e.g., forward, reverse, or “neutral”
mode) may cause the loss of hydrostatic braking capacity. A braking system, redundant to the hydrostatic
transmission must, therefore, be provided which is adequate to stop and hold the system should the
condition develop.
Speed Limits
min-1 (rpm)
Frame size 060 080 110 160 250
at max. disp. 3600 3100 2800 2500 2200
Rated speed
at min. disp. 5600 5000 4500 4000 3400
at max. disp. 4400 4000 3600 3200 2700
Maximum speed1)
at min. disp. 7000 6250 5600 5000 4250
1)
Contact your Sauer-Danfoss representative for max. speed at displacements between
max. and min. displacement.
Speed limits
max. speed
at min. Curve determined
displacement by rated flow
For operation within this range contact
Sauer-Danfoss representative.
max. speed
rated speed at max.
at min. displacement
Speed min-1 (rpm)
displacement
Acceptable operating range
rated speed
at max.
displacement
Pressure limits
System pressure is the dominant operating variable affecting hydraulic unit life. High pressure, which
results from high load, reduces expected life in a manner similar to the affects of high load on other
mechanical assemblies such as engines and gear boxes. There are load-to-life relationships for the
rotating group and for the shaft anti-friction bearings.
Continuous pressure is the pressure at which the hydrostatic system could operate continuously and still
achieve acceptable hydrostatic life. This pressure level varies depending on operating speed, and on the
life requirements for a particular application. While most mobile applications require system pressure to
vary widely during operation, a “weighted average” pressure can be derived from a machine duty cycle.
(A duty cycle is a means of quantifying the pressure and speed demands of a particular system on a
percent time basis). Once a duty cycle has been determined or estimated for a specific application,
contact your Danfoss representative for system life ratings for the application.
Maximum delta pressure is the highest intermittent pressure allowed, and is the relief valve setting. It is
determined by the maximum machine load demand. For most systems, the load should move at this
pressure.
Maximum pressure is assumed to occur a small percentage of operating time, usually less than 2 % of
the total. Both the continuous and maximum pressure limits must be satisfied to achieve the expected
life.
Minimum low pressure must maintained under all operating conditions to avoid cavitation.
Loop flushing
An integral non-adjustable loop flushing valve is incorporated into all these motors. Installations that
require fluid to be removed from the low pressure side of the system circuit because of cooling
requirements or contamination removal will benefit from loop flushing.
The integral loop flushing valve is equipped with an orificed charge pressure relief valve designed with a
cracking pressure of 16 bar [232 psi]. Valves are available with several orifice sizes to meet the flushing
flow requirements of all system operating conditions.
The total system charge pump flow should be of sufficient volume to accommodate:
Although charge pump sizing requires the consideration of many system variables, the following table
gives a recommendation of what charge pump displacement may be required to accommodate the
flushing flow of each available charge relief valve orifice.
W Warning
Warning: The loss of hydrostatic drive line power in any mode of operation (e.g., forward, reverse, or
“neutral” mode) may cause the loss of hydrostatic braking capacity. A braking system, redundant to the
hydrostatic transmission must, therefore, be provided which is adequate to stop and hold the system
should the condition develop.
A B
P001 830
Low system pressure minus case pressure
E4 E6 F0 F3 G0 G3 H0
[508]
35
[363]
25
bar [psi]
[218]
15
[73]
5
0 5 10 15 20 25 30 35 40
[1.3] [2.6] [4.0] [5.3] [6.6] [8.0] [9.2] [10.6]
Case flow l/min [US gal/min]
P001 860E
Equation:
Where:
QFlush = flushing flow per motor
QCharge = charge flow at operating speed
kMo = number of motors feeded by one pump
QLeak. = sum of external leakages including
• motor leakage
• pump leakage + internal consumers:
Hydraulic fluids
Ratings and data are based on operating with hydraulic fluids containing oxidation, rust and foam
inhibitors. These fluids must possess good thermal and hydrolytic stability to prevent wear, erosion and
corrosion of the internal components.
Fire resistant fluids are also suitable at modified operating conditions. Please see
Danfoss literature Hydraulic Fluids and Lubricants Technical Information for more information.
It is not permissible to mix hydraulic fluids. For more information contact your
Danfoss representative.
Suitable Hydraulic fluids:
Temperature range 1)
°C [°F]
Minimum -40 [-40] intermittent, cold start
Rated 104 [220]
Maximum 115 [240] intermittent
1) At the hottest point, normally the case drain port.
Viscosity
mm²/s [SUS]
Minimum 7 [49] intermittent
Recommanded operating range 12-80 [70-370]
Maximum 1600 [7500] intermittent cold start
W Warning
The loss of hydrostatic drive line power in any mode of operation (e.g., forward, reverse, or “neutral”
mode) may cause the loss of hydrostatic braking capacity. A braking system, redundant to the hydrostatic
transmission must, therefore, be provided which is adequate to stop and hold the system should the
condition develop.
Reservoir
The function of the reservoir is to remove air and to provide make up fluid for volume changes associated
with fluid expansion or contraction, possible cylinder flow, and minor leakage.
The reservoir should be designed to accommodate maximum volume changes during all system
operating modes and to promote deaeration of the fluid as it passes through the tank.
A minimum reservoir volume equal to 1/2 to 1 1/2 times charge pump flow/min is suggested. This allows
30 seconds fluid dwell for removing entrained air at the maximum return flow. This is usually adequate to
allow for a closed reservoir (no breather) in most applications. The reservoir outlet to the charge pump
inlet should be above the bottom of the reservoir to take advantage of gravity separation and prevent
large foreign particles from entering the charge inlet line.
The reservoir inlet (fluid return) should be positioned so that the flow to the reservoir is discharged below
the normal fluid level, and also directed into the interior of the reservoir for maximum dwell and efficient
deaeration.
Motor bearing life
The rated motor bearing life, Lh10 , shown in the table below, is based on a 90 % survival rate of shaft
bearings, when operating at a speed of n = 1500 min-1 (rpm) with a charge pressure of 20 bar [290 psi]
and without external shaft load.
Contact your Danfoss representative for bearing life values at other pressures and angles.
Lifetimes for speeds other than 1500 min-1 (rpm) can be calculated from:
Fr
Fa
X1
Fr
Fa
X1
Fr
Fa
P001 166E
• The maximum allowable radial load (Fr) based on the distance (x1) from the mounting flange to the
load.
• The maximum allowable axial load (Fa).
• The actual distance of (Fr) for a given application from the mounting flangeto the load is (x2).
• A is the basic distance.
• Fa/∆p ratio of allowable axial load, dependent upon system pressure.
The values in the table are maximum values, and are not allowed under continuous load conditions.
Allowable external shaft load, when shaft load distance is different from standard
Use this formula to calculate maximum allowable radial load when max. shaft load distance (X2) is
different from (X1):
(X2) is the actual distance of (Fr) from the mounting flange to the load for a given application. If X2 < X1,
(Fr) could also be calculated by the first equation, but in addition the bearing life has to be checked.
Contact your Danfoss representative for load ratings of specific shafts or when the load orientation
deviates more than 35° in either direction from the optimum.
Metric system:
Inch system:
ar [6090 psi]
η v = 420 b
95
tota
psi] η = l efficie
Efficiency %
η
t
85
80
0 25 50 75 100
Speed % of rated speed P001 155E
This graph shows typical overall efficiencies for Series 51 and 51-1 motors operating at maximum
displacement and system pressures up to 420 bar [6090 psi], and a fluid viscosity of 8.2 mm²/s [53 SUS].
These efficiencies can be used for all frame sizes.
Overall efficiency at maximum displacement
420
[6090]
280
System pressure bar [psi]
[4060] 94.5%
93.5%
140
[2030] 90.5%
84.5%
74.5%
0
0 25 50 75 100
Speed % of rated speed
P001 137E
This graph shows typical overall efficiencies for Series 51 and 51-1 motors operating at 30% of maximum
displacement and system pressures up to 420 bar [6090 psi], and a fluidviscosity of 8.2 mm²/s (53 SUS).
These efficiencies can be used for all frame sizes.
Overall efficiency and volumetric efficiency at 30% of maximum displacement
100
95
volumetric efficiency η v = 210 bar [3050 psi]
90
η v = 420 bar [6090 psi]
85
Efficiency %
70
65
60
0 25 50 75 100
Speed % of rated speed P001 156E
This graph shows typical overall efficiencies for Series 51 and 51-1 motors operating at 30% of maximum
displacement and system pressures up to 420 bar [6090 psi], and a fluidviscosity of 8.2 mm²/s (53 SUS).
These efficiencies can be used for all frame sizes.
Overall efficiency at 30% of maximum displacement
420
[6090]
System pressure bar [psi]
280
[4060]
81%
80%
140
[2030] 77%
71%
61%
0
0 25 50 75 100
Speed % of rated speed P001 138E
Speed sensor
An optional speed sensor for direct measurement of speed is available. This sensor may also be used to
sense the direction of rotation.
A special magnetic speed pick-up ring is pressed onto the outside diameter of the shaft and a Hall effect
sensor is located in the motor housing. The sensor accepts supply voltage and outputs a digital pulse
signal in response to the speed of the ring. The output changes its high/low state as the north and south
poles of the permanently magnetized speed ring pass by the face of the sensor. The digital signal is
generated at frequencies suitable for microprocessor based controls.
The sensor is available with different connectors (see below).
The SAE and DIN flange motors use a flat end speed sensor. The cartridge flange motors use a conical end
speed sensor.
Contact your Danfoss representative for more information.
Data Magnetic Speed Pick-up Ring
Frame Size 060 080 110 160 250
Pulse/Rev 45 49 54 61 71
P001 492
P002 108E
Packard Weather-Pack
4 pin A
(Supplied Connector) B
Mating Connector C
No.: K03379 D
P001 758E
Id.-No.: 505341
m = Suitable configuration
Hydraulic two-position control – option N1NN for 51-1 frame size 060, 080, 110
Circuit Diagram–Motor with Hydraulic Two-Position Control N1NN
L2 N
A
n
min.
disp.
T3
T2
X1 M5
(M3) B
L1 M4 P001 779E
Ports:
A, B = Main pressure lines
L1, L2 = Drain lines
M4 = Gauge port
servo pressure
M5 = Gauge port
servo supply pressure
internal
X1 (M3) = Control pressure port
T2, T3, T3 = Optional orifices
N = Speed sensor
Control pressure
No pressure on port X1 (M3) = maximum displacement
Control pressure on port X1 (M3) = minimum displacement.
Max. control pressure X1(M3) = 50 bar [725 psi]
The graph shows the necessary external and internal (= low system pressure) control pressure X1, which
is needed to stroke the motor depending on high system pressure.
0
0 100 200 300 400
[1450] [2900] [4350] [5800]
System pressure bar [psi]
P001 877E
min max
Displacement
P001 875E
T3
T2
T7 T8
T1
M5
B M2
L1 X1 M7 P100 177E
Ports:
A, B = Main pressure lines
L1, L2 = Drain lines
M1, M2 = Gauge port for A and B
M3, M4 = Servo pressure port
M5 = Gauge port servo supply pressure internal
M7 = Gauge port control pressure
Control pressure
No pressure on port X1 = maximum displacement
Control pressure on port X1 = minimum displacement.
Max. control pressure X1 = 50 bar [725 psi]
The standard control start point setting = 3 bar [44 psi]
Control operation HZB1
Control pressure Δ bar [psi]
[44]
0 3
min max
Displacement
P100 179E
n
min.
disp.
T3 T3 T3
M3 M3 M3
with Electric with Hydraulic without B
brake pressure brake pressure Brake pressure L1 M4
defeat defeat defeat P001 834E
Ports:
A, B = Main pressure lines T3 = Orifice
min max
Displacement
P001 173E
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
Pressure Compensator Configuration: TAD1, TAD2, TAD7 with Electric Brake Pressure Defeat
A solenoid-switched valve ahead of the pressure compensator prevents operation in the deceleration
direction (when motor is running in pump mode). This is designed to prevent rapid or uncontrolled
deceleration while the vehicle/machine is slowing down.
The solenoid valve must be controlled by an external electric signal, based on direction of motor rotation,
based on the following table.
Solenoid Connectors
Magnet-Steckanschluss AMP Junior Timer
für DIN 46350 Two Pin Connector
(angebauter Stecker) (Supplied Connector)
2 1
Gegenstecker A B Mating Connector
Nr.: K09129 No.: K19815
Id.-Nr.: 514117 P001 752D Id.-No.: 508388 P001 751E
Solenoid Data
Configuration Voltage Electric power Connector
TAD1 12 VDC 34 W DIN 46350
AMP Junior Timer
TAD7 12 VDC 34 W
two pin connector
TAD2 24 VDC 34 W DIN 46350
Pressure Compensator Control – Options TA** for 51 Frame Size 160, 250
Circuit Diagram–Motor with Pressure Compensator Control TA**
L2 M4 M3 N
XA A
X4 X4
M1
n
max.
disp.
T2 T3
(X3)
T1 T7 T8 M5
XB B M2
with without
Brake pressure Brake pressure L1 P001 836E
defeat defeat
Ports:
A, B = Main pressure lines XA, XB = Control pressure ports,
L1, L2 = Drain lines brake pressure defeat
M1, M2 = Gauge port for A and B X4 = Gauge port pressure compensator
M3, M4 = Gauge port servo pressure T1, T2, T3, = Optional orifices
M5 (X3) = Gauge port servo supply T7, T8
N = Speed sensor
min max
Displacement
P001 173E
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
Not all control options are shown in this Technical Information Contact your Danfoss representative for
special control functions.
Hydraulic Two-Position Control – Options TH** for 51-1 Frame Size 060, 080, 110
Circuit Diagram–Motor with Two-Position Control TH**
L2 N
A
XB XA
min.
disp.
T3 T3 T3
X1 M3 X1 M3 X1 M3
B
with Electric with Hydraulic without
brake pressure brake pressure Brake pressure L1 M4
defeat defeat defeat P001 835E
Ports:
A, B = Main pressure lines XA, XB = Control pressure ports
L1, L2 = Drain lines brake pressure defeat
M3, M4 = Gauge port servo pressure T3 = Orifice
X1 = Control pressure port, N = Speed sensor hydr. override to max. angle
Pressure compensator
override bar, [psi]
setting range
PCOR start
130 370 [5370]
Hydraulic
two-position-
control
[1890]
[145 psi]
min. 10 bar
[510 psi]
Ramp < 10
[145]
max. 35 bar
min. max.
Displacement
P001 776E
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
Pressure Compensator Configuration: THD1, THD2, THD7 with Electric Brake Pressure Defeat
A solenoid-switched valve ahead of the pressure compensator prevents operation in the deceleration
direction (when motor is running in pump mode). This is designed to prevent rapid or uncontrolled
deceleration while the vehicle/machine is slowing down.
The solenoid valve must be controlled by an external electric signal, based on direction of motor rotation,
based on the following table.
Pressure Compensator Operation
Rotation High pressure port Solenoid PCOR-Function
CW A energized yes
CW A non energized no
CCW B energized no
CCW B non energized yes
Solenoid Connectors
Magnet-Steckanschluss AMP Junior Timer
für DIN 46350 Two Pin Connector
(angebauter Stecker) (Supplied Connector)
2 1
Gegenstecker A B Mating Connector
Nr.: K09129 No.: K19815
Id.-Nr.: 514117 P001 752D Id.-No.: 508388 P001 751E
Solenoid Data
Configuration Voltage Electric power Connector
THD1 12 VDC 34 W DIN 46350
AMP Junior Timer
THD7 12 VDC 34 W
two pin connector
THD2 24 VDC 34 W DIN 46350
Hydraulic Two-Position Control – Options TH** for 51 Frame Size 160, 250
Circuit Diagram–Motor with Two-Position Control TH**
L2 M4 M3 N
A
XA X4 X4 M1
n
max.
disp.
T2 T3
X1 X1 T1 T7 T8 (X3)
M5
XB
B M2
with without
Brake pressure Brake pressure L1
P001 837E
defeat defeat
Ports:
A, B = Main pressure lines X4 = Gauge port pressure compensator
L1, L2 = Drain lines XA, XB = Control pressure ports M1, M2 = Gauge port for A and B brake pressure
defeat
M3, M4 = Gauge port servo pressure T1, T2, T3, = Optional orifices
M5 (X3) = Gauge port servo supply T7, T8
X1 = Hydr. two-position signal N = Speed sensor
Pressure compensator
override bar, [psi]
setting range
PCOR start
130 370 [5370]
Hydraulic
two-position-
control
[1890]
[145 psi]
min. 10 bar
[510 psi]
Ramp < 10
[145]
max. 35 bar
min. max.
Displacement
P001 776E
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
Not all control options are shown in this Technical Information Contact your Danfoss representative for
special control functions.
Electrohydraulic Two-Position Control – Options E1B1, E2B1, E7B1 for 51-1 Frame Size 060, 080,
110
Circuit Diagram–Motor with Electrohydraulic Two-Position Control E1B1, E2B1, E7B1
L2 N
A
n
min.
disp.
T3
T2
M5 M3
B
L1 M4 P001 780E
Ports:
A, B = Main pressure lines
L1, L2 = Drain lines
M3, M4 = Servo pressure port
M5 = Gauge port
servo supply pressure internal
T2, T3 = Optional orifices
N = Speed sensor
20
[290]
10
[145] min. pilot pressure at all other
conditions motor and pump mode
in both directions
0
0 100 200 300 400
[1450] [2900] [4350] [5800]
System pressure bar [psi] P001 878E
12V
/24V
min max
Displacement
P001 870E
Solenoid Connectors
Magnet-Steckanschluss AMP Junior Timer
für DIN 46350 Two Pin Connector
(angebauter Stecker) (Supplied Connector)
2 1
Gegenstecker A B Mating Connector
Nr.: K09129 No.: K19815
Id.-Nr.: 514117 P001 752D Id.-No.: 508388 P001 751E
Solenoid Data
Configuration Voltage Electric power Connector
E1B1 12 VDC 14.7 W DIN 46350
AMP Junior Timer
E7B1 12 VDC 14.7 W
two pin connector
E2B1 24 VDC 14.7 W DIN 46350
T2 T3
T1 T7 T8
M5
B M2
L1 M8 M7 P100 180E
Ports:
A, B = Main pressure lines
L1, L2 = Drain lines
M1, M2 = Gauge port for A and B
M3, M4 = Gauge port
servo pressure
M5 = Gauge port servo supply pressure, internal
M7, M8 = Gauge port control pressure, internal
T1, T2, T3, = Optional orifices
T7, T8
N = Speed sensor
12V
/24V
min max
Displacement
P001 870E
Solenoid Connector
Magnet-Steckanschluss
für DIN 46350
(angebauter Stecker)
Gegenstecker A B
Nr.: K09129
Id.-Nr.: 514117 P001 752D
Solenoid Data
Configuration Voltage Electric power Connector
E1A5 12 VDC
14.7 W DIN 46350
E2A5 24 VDC
n
min.
disp.
T3
T2
M5 M3
B
L1 M4 P001 867E
Ports:
A, B = Main pressure lines
L1, L2 = Drain lines
M3, M4 = Servo pressure port
M5 = Gauge port servo supply pressure, internal
T2, T3 = Optional orifices
N = Speed sensor
10
[145] min. pilot pressure at all other
conditions motor and pump mode
in both directions
0
0 100 200 300 400
[1450] [2900] [4350] [5800]
System pressure bar [psi] P001 879E
12V
/24V
min max
Displacement
P001 871E
Solenoid Connector
Magnet-Steckanschluss
für DIN 46350
(angebauter Stecker)
Gegenstecker A B
Nr.: K09129
Id.-Nr.: 514117 P001 752D
Solenoid Data
Configuration Voltage Electric power Connector
F1B1 12 VDC
14.7 W DIN 46350
F2B1 24 VDC
T2 T3
T1 T7 T8
M5
B M2
L1 M8 M7 P001 874E
Ports:
A, B = Main pressure lines
L1, L2 = Drain lines
M1, M2 = Gauge port for A and B
M3, M4 = Gauge port servo pressure
M5 = Gauge port servo supply pressure, internal
M7, M8 = Gauge port control pressure, internal
T1, T2, T3, = Optional orifices
T7, T8
N = Speed sensor
12V
/24V
min max
Displacement
P001 871E
Solenoid Connector
Magnet-Steckanschluss
für DIN 46350
(angebauter Stecker)
Gegenstecker A B
Nr.: K09129
Id.-Nr.: 514117 P001 752D
Solenoid Data
Configuration Voltage Electric power Connector
F1A5 12 VDC
14.7 W DIN 46350
F2A5 24 VDC
Electrohydraulic Two-Position Control – Options T1**, T2**, T7** for 51-1 Frame Size 060, 080, 110
Circuit Diagram–Motor with Electrohydraulic Two-Position Control T1**, T2**, T7**
L2 N
XB XA A
n
min.
disp.
T3 T3 T3
M3 M3 M3
B
with Electric with Hydraulic without
brake pressure brake pressure Brake pressure L1 M4
P001 784E
defeat defeat defeat
Ports:
A, B = Main pressure lines
L1, L2 = Drain lines
M3, M4 = Gauge port servo pressure
XA, XB = Control pressure ports, brake pressure defeat
T3 = Optional orifices
N = Speed sensor
setting range
Electrohydraulic
370 [5 370]
PCOR start
two-position-
control
[1890]
130
12V/24V
10 [145]
Ramp <
min. max.
Displacement
P001 872E
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
Pressure Compensator Configuration: T*D1, T*D2, T* D7 with Electric Brake Pressure Defeat
A solenoid-switched valve ahead of the pressure compensator prevents operation in the deceleration
direction (when motor is running in pump mode). This is designed to prevent rapid or uncontrolled
deceleration while the vehicle/machine is slowing down.
The solenoid valve must be controlled by an external electric signal, based on direction of motor rotation,
based on the following table.
Pressure Compensator Operation
Rotation High pressure port Solenoid PCOR-Function
CW A energized yes
CW A non energized no
CCW B energized no
CCW B non energized yes
Solenoid Connectors
Magnet-Steckanschluss AMP Junior Timer
für DIN 46350 Two Pin Connector
(angebauter Stecker) (Supplied Connector)
2 1
Gegenstecker A B Mating Connector
Nr.: K09129 No.: K19815
Id.-Nr.: 514117 P001 752D Id.-No.: 508388 P001 751E
Solenoid Data
Configuration Voltage Electric power Connector
T1D1 12 VDC 34 W DIN 46350
AMP Junior Timer
T7D7 12 VDC 34 W
two pin connector
T2D2 24 VDC 34 W DIN 46350
Not all control options are shown in this Technical Information. Contact your Danfoss representative for
special control functions.
Electrohydraulic Two-Position Control – Options T1**, T2** for 51 Frame Size 160, 250
Circuit Diagram–Motor with Electrohydraulic Two-Position Control T1**, T2**
L2 M4 M3 N
A
XA X4 X4
M1
n
max.
disp.
T2 T3
T1 T7 T8
M5
XB
B M2
with without
L1 P001 785E
Brake pressure Brake pressure
defeat defeat
Ports:
A, B = Main pressure lines XA, XB = Control pressure ports,
L1, L2 = Drain lines brake pressure defeat
M1, M2 = Gauge port for A and B T1, T2, T3, = Optional orifices
M3, M4 = Gauge port servo pressure T7, T8
M5 = Gauge port servo supply N = Speed sensor pressure internal
Electrohydraulic
370 [5 370]
PCOR start
two-position-
control
[1890]
130
12V/24V
10 [145]
Ramp <
min. max.
Displacement
P001 872E
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
Solenoid Connector
Magnet-Steckanschluss
für DIN 46350
(angebauter Stecker)
Gegenstecker A B
Nr.: K09129
Id.-Nr.: 514117 P001 752D
Solenoid Data
Configuration Voltage Electric power Connector
T1C2 12 VDC
34 W DIN 46350
T2C2 24 VDC
A
M1
n
T4
max.
disp.
T5 T5
U7 U6 U7 U6 T2 T3
T6
T1 T7 T8
M5
XA XB
B M2
WITH WITHOUT
BRAKE PRESSURE BRAKE PRESSURE
DEFEAT DEFEAT
L1 M7 X1 M8 P001 786E
Ports:
A, B = Main pressure lines
X1 = Port for control supply
L1, L2 = Drain lines pressure external
M1, M2 = Gauge port for A and B
XA, XB = Control pressure ports, brake pressure defeat
M3, M4 = Gauge port servo pressure
M5 = Gauge port servo supply pressure internal
T1, T2, T3,T4, T5, T6,T7, T8,U6, U7 = Optional orifices
M7, M8 = Gauge port control pressure internal
N = Speed sensor
J K
[1890] PCOR start
370 [5370]
High pressure Dp bar [psi]
setting range
Control start
50
85
130
Current mA
Ramp < 10 bar
15
50
[145 psi]
min max
Ramp
Connectors
MS Connector Packard Weather-Pack
A
MS3102C-14S-2P 4 pin
(Supplied Connector) (Supplied Connector) B
D A
C B C
Mating Connector Mating Connector D
No.: K08106 No.: K03384
Id.-No.: 615062 P001 753E Id.-No.: 712208 P001 759E
Configuration Options
Configuration PCOR at port Brake pressure defead
EPA1/EQA1 A+B with
EPA2/EQA2 A+B without
Pressure Compensator Override Configuration: EPA1, EQA1 with Brake Pressure Defeat
A shuttle valve ahead of the pressure compensator prevents operation in the deceleration direction
(when motor is running in pump mode). This is designed to prevent rapid or uncontrolled deceleration
while the vehicle/machine is slowing down.
The shuttle valve must be controlled by a 2-line external signal, based on direction of motor rotation,
based on the following table.
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
Pressure Compensator Operation
Rotation High pressure port Control pressure on port PCOR-Function
CW A XA no
CW A XB yes
CCW B XA yes
CCW B XB no
Differential control pressure between port XA/XB
pmin = 0.5 bar [7 psi]
pmax = 50 bar [725 psi]
Pressure Compensator Override Configuration: EPA2, EQA2 without Brake Pressure Defeat
The pressure compensator override functions when the motor is running in motor mode as well as in
pump (deceleration) mode.
Not all control options are shown in this Technical Information
Contact your Danfoss representative for special control functions.
Electrohydraulic Proportional Control – Options L1B1, L2B1, L7B1 for 51 Frame Size 060, 080, 110,
160, 250
Circuit Diagram–Motor with Electrohydraulic Proportional Control L1B1, L2B1, L7B1
L2 M4 M3 N
A
M1
n
max.
disp.
T2 T3
T1 T7 T8 M5
B M2
L1 P001 787E
Ports:
A, B = Main pressure lines
L1, L2 = Drain lines
M1, M2 = Gauge port for A and B
M3, M4 = Gauge port servo pressure
M5 = Gauge port servo supply pressure
T1, T2, T3, T7, T8 = Optional orifices
N = Speed sensor
L7** L8**
1290 645
Control current (mA)
440 220
0 0
20% 100%
min max
Displacement
P001 777E
Solenoid Connectors
Magnet-Steckanschluss AMP Junior Timer
für DIN 46350 Two Pin Connector
(angebauter Stecker) (Supplied Connector)
2 1
Gegenstecker A B Mating Connector
Nr.: K09129 No.: K19815
Id.-Nr.: 514117 P001 752D Id.-No.: 508388 P001 751E
Solenoid Data
Configuration Voltage Nominal Control current Connector
resistance 20 °C
Start End max.
L1B1 12 VDC 5.7 Ω 440 mA 1290 mA 1500 mA DIN 46350
L7B1 AMP Junior Timer
two pin connector
L2B1 24 VDC 21.3 Ω 220 mA 645 mA 750 mA DIN 46350
Not all control options are shown in this Technical Information Contact your Danfoss representative for
special control functions.
Electrohydraulic
Proportional Control – Options D7M1, D8M1 for 51 Frame Size 060, 080, 110, 160, 250
Circuit Diagram–Motor with Electrohydraulic Proportional Control D7M1, D8M1 with Pressure Compensator
(PCOR) and Hydraulic Brake Pressure Defeat
L2 M4 M3 N
A
XB XA
M1
n
T4
max.
disp.
U7
T6 T2 T3
T1
T7 T8
(M5)
X3
M7
B M2
L1 P001 869E
Ports:
A, B = Main pressure lines
L1, L2 = Drain lines
M1, M2 = Gauge port for A and B
M3, M4 = Gauge port servo pressure
X3 (M5) = Servo pressure supply
M7 = Gauge port control pressure
XA, XB = Control pressure ports hydr. brake pressure defeat
T1, T2, T3, T4, T6, T7, T8, U7 = Optional orifices
N = Speed sensor
Pressure compensator
override
setting range
PCOR start
Electrohydr.
prop. control
370 bar D8M1 D7M1
[5370 psi]
(ratio 5:1)
130 bar
[1890 psi] 594 1188
end-current
Ramp < 10 bar
320 640
[145 psi]
start-current
min max
Displacement
P001 873E
Pressure Compensator Configuration: D7M1, D8M1 with Hydraulic Brake Pressure Defeat
A shuttle valve ahead of the pressure compensator prevents operation in the deceleration direction
(when motor is running in pump mode). This is designed to prevent rapid or uncontrolled deceleration
while the vehicle/machine is slowing down.
The shuttle valve must be controlled by a 2-line external signal, based on direction of motor rotation,
based on the following table.
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
Solenoid Connector
AMP Junior Timer
Two Pin Connector
(Supplied Connector)
2 1
Mating Connector
No.: K19815
Id.-No.: 508388 P001 751E
Solenoid Data
nominal Control current
Configuration Voltage Connector
resistance 20 °C Start End max.
D7M1 12 VDC 5.7 Ω 640 mA 1188 mA 1500 mA AMP Junior Timer
D8M1 24 VDC 21.2 Ω 320 mA 594 mA 750 mA two pin connector
A
M1
n
T4
max.
disp.
T5 T5
U7 U6 U7 U6 T2 T3
T6
T1 T7 T8
M5
XA XB
B M2
with without
Brake pressure Brake pressure L1 X1 M7 P001 788E
defeat defeat
Ports:
A, B = Main pressure lines X1 = Control pressure port
L1, L2 = Drain lines XA, XB = Control pressure ports
M1, M2 = Gauge port or A and B brake pressure defeat
M3, M4 = Gauge port servo pressure T1, T2, T3,T4, = Optional orifices
M5 = Gauge port T5, T6, T7, T8,
servo supply pressure internal U6, U7
M7 = Gauge port control pressure N = Speed sensor
Ramp
Control Ramp
Control ramp range from max. to min. displ.
(control pressure rise)
bar [psi]
7 [102]
14 [206]
Configuration Options
Configuration PCOR at port Brake pressure defead
HSA1 A+B with
HSA2 A+B without
A
M1
n
max.
disp.
T2 T3
T1 T7 T8 M5
B M2
L1 X1 M7 P001 880E
Ports:
A, B = Main pressure lines
L1, L2 = Drain lines
M1, M2 = Gauge port for A and B
M3, M4 = Servo pressure port
M5 = Gauge port
servo supply pressure internal
M7 = Gauge port control pressure
X1 = Control pressure port
T1, T2, T3, T7, T8 = Optional orifices
N = Speed sensor
Control start
min Displacement max version
P001 881E
Control Ramp
Control ramp range from max. to min. displ.
(control pressure rise)
bar [psi]
7 [102]
14 [206]
Y W
Loop flushing
X shuttle valve
Charge pressure W
215.0
relief valve
[8.45] Gauge port “M4”
M4
88.5 System pressure max. angle
[3.48] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B B A
[1 1/16 -12UN-2B] 23.8
]
[0.94
[8.21]
208.5
Y
70.0
[2.93]
74.5
]
[2.76 Gauge port “M2”
50.8
[2.00
[1.57].
70.0
40.0
] System pressure “B”
19° [2.76
]
0.875-14UNF-2B
[7/8 -14UNF-2B]
Gauge port “M1”
[2.93]
74.5
[3.87]
98.3 0.875-14UNF-2B
[7/8 -14UNF-2B]
Alternate position
Case drain “L2” Split flange boss “A”+”B”
1.0625-12UN-2B min. angle stop
[1 1/16 -12UN-2B] DN 19 typ II 40 MPa series
adjustment per ISO 6162 [SAE 0.75]
88.5 4 thread: 0.375-16UNC-2B
[3/8 -16UNC-2B]
[3.48] 19 [0.75] min.
260.1 max. full thread depth
[10.24 max.]
Y W
X
242.0
W
[9.53] Gauge port “M4”
M4
Y
[4.05]
103.0
47.0
[1.94]
47.0 [1.85
DN 19 typ II 40 MPa series ] 73.0
per ISO 6162 [SAE 0.75] [1.85 ]
[2.87
4 thread: 0.375-16UNC-2B 73.0
] Split flange boss “B”
[3/8 -16UNC-2B] [2.87
19 [0.75] min. DN 19 typ II 40 MPa series
full thread depth per ISO 6162 [SAE 0.75]
4 thread: 0.375-16UNC-2B
Gauge ports “M1”+”M2” [3/8 -16UNC-2B]
19 [0.75] min.
System pressure “A”+”B” full thread depth
0.5625-18UNF-2B
[9/16 -18UNF-2B] P001 790E
M4
Control start
88.5 adjustment
[3.48]
M3
Case drain “L1”
1.0625-12UN-2B
W
[6.77]
[1 1/16 -12UN-2B]
172
A
Y Gauge port “M1”
System pressure “A”
0.5625-18UNF-2B Supply pressure
[2.93]
74.5
L1
M1
[9/16 -18UNF-2B] Shuttle valve
50.8 ]
[2.00 0.5625-18UNF-2B
[1.60]
41
Gauge port “M5” [9/16 -18UNF-2B]
19° 0 Gauge port “M2”
0 Servo pressure supply
23.9 ] 0.5625-18UNF-2B System pressure “B”
[0.94 0.5625-18UNF-2B
[3.87] max.
[9/16 -18UNF-2B]
[2.93]
74.5
98 max.
M5
[9/16 -18UNF-2B]
[3.77]
96
L2
Alternate position
Case drain “L2” min. angle stop Control mounting U
1.0625-12UN-2B
adjustment surface
[1 1/16 -12UN-2B] Gauge port “M7” U M7
Control pressure Split flange boss “A”+”B”
0.5625-18UNF-2B DN 19 typ II 40 MPa series Shaft centerline
X1
88.5 [9/16 -18UNF-2B] per ISO 6162 [SAE 0.75]
[3.48]
[1.93]
4 thread: 0.375-16UNC-2B
49.0
294.0 [3/8 -16UNC-2B]
19 [0.75] min.
[11.56] full thread depth Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 70.0
]
[2.76
70.0
] 45.0
[2.76 .0 ]
Gauge port “M1”+”M2” 45 [1.77
]
System pressure “A”+”B” [1.77
X 0.5625-18UNF-2B
Gauge port “M4”
[9/16 -18UNF-2B]
Servo pressure max. angle
0.5625-18UNF-2B
263.0 [9/16 -18UNF-2B]
M3
[10.35]
W
M4
0
23.8 ]
[0.94
121.0
[4.77]
50.8 ]
[2.00
B
M4
W
0
A
Y
M5
[4.05]
103.0
L1
Supply pressure
[2.22]
Shuttle valve
56.0
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Split flange boss “A” Split flange boss “B”
DN 19 typ II 40 MPa series DN 19 typ II 40 MPa series
per ISO 6162 [SAE 0.75] per ISO 6162 [SAE 0.75]
L2 4 thread: 0.375-16UNC-2B 4 thread: 0.375-16UNC-2B
[3/8 -16UNC-2B] [3/8 -16UNC-2B]
19 [0.75] min. 19 [0.75] min.
full thread depth full thread depth
P001 965E
[5.75 ± 0.06]
146.0 ± 1.6
Z
Ø103.4
Ø44.45
Ø80.0
[4.07]
[1.75]
[3.15]
ØD
ØA
ØG
H Ø19.5 [0.77]
other side max
screw head space
12.45 18.0
[0.49] [0.71]
C 57.25 ± 0.2 57.25 ± 0.2
Coupling may not protrude [2.25 ± 0.01] [2.25 ± 0.01]
beyond this surface 146.0 ± 1.6
P001 809E
[5.75 ± 0.06]
190.0
Charge pressure W
relief valve
[7.49]
Gauge port “M4”
M4
59.0 System pressure max. angle
[2.32] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B
23.8
B A
[1 1/16 -12UN-2B] ]
[0.94
[8.21]
208.5
Y
[3.05]
70.0
77.5
]
[2.76
50.8
[1.57]
40.0
70.0 System pressure “B”
]
19° [2.76
]
0.875-14UNF-2B
[7/8 -14UNF-2B]
Gauge port “M1”
[2.97]
75.5
[3.89]
98.9
0.875-14UNF-2B
[7/8 -14UNF-2B]
Alternate position
Case drain “L2” min. angle stop
1.0625-12UN-2B adjustment Split flange boss “A”+”B”
[1 1/16 -12UN-2B] DN 19 typ II 40 MPa series
90.0 per ISO 6162 [SAE 0.75]
4 thread: 0.375-16UNC-2B
[3.54] [3/8 -16UNC-2B]
234.1 max. 19 [0.75] min.
[9.22 max.] full thread depth
Y W
X
W
218.0
[8.57] Gauge port “M4”
M4
Y
[3.70]
94.0
47.0
[1.94]
]
47.0 [1.85
DN 19 typ II 40 MPa series ] 73.0
per ISO 6162 [SAE 0.75] [1.85 ]
[2.87
4 thread: 0.375-16UNC-2B 73.0
[3/8 -16UNC-2B] .87 ] Split flange boss “B”
19 [0.75] min. [2
DN 19 typ II 40 MPa series
full thread depth per ISO 6162 [SAE 0.75]
4 thread: 0.375-16UNC-2B
Gauge ports “M1”+”M2” [3/8 -16UNC-2B]
19 [0.75] min.
System pressure “A”+”B” full thread depth
0.5625-18UNF-2B
[9/16 -18UNF-2B]
P001 791E
M4
shuttle valve [9/16 -18UNF-2B]
Charge pressure
relief valve
Control start
59.0 adjustment
[2.32] W
M3
Case drain “L1”
1.0625-12UN-2B Supply pressure
[1 1/16 -12UN-2B]
[6.77]
172.0
A
Y Gauge port “M1” Shuttle valve
0.5625-18UNF-2B
L1 System pressure “A” [9/16 -18UNF-2B]
0.5625-18UNF-2B
[3.05]
M1
77.5
[9/16 -18UNF-2B]
50.8 ]
[2.00
[1.60]
41.0
Gauge port “M5”
0
19° Gauge port “M2”
0 Servo pressure supply
23.9 ] 0.5625-18UNF-2B System pressure “B”
[0.94 [9/16 -18UNF-2B] 0.5625-18UNF-2B
[2.97]
75.5
[9/16 -18UNF-2B]
M5
[3.89]
[3.77]
99.0
96.0
L2
U
Alternate position M7
Case drain “L2” min. angle stop Control mounting
1.0625-12UN-2B adjustment surface
[1 1/16 -12UN-2B] Gauge port “M7” U Shaft centerline
X1
Control pressure Split flange boss “A”+”B”
[1.93]
49.0
0.5625-18UNF-2B DN 19 typ II 40 MPa series
90.0 [9/16 -18UNF-2B] per ISO 6162 [SAE 0.75]
[3.54] 4 thread: 0.375-16UNC-2B
270.0 [3/8 -16UNC-2B] Control pressure port “X1”
19 [0.75] min. 0.5625-18UNF-2B
[10.64] full thread depth [9/16 -18UNF-2B]
Y 70.0
]
[2.76
70.0
] 45.0
[2.76 ]
Gauge port “M1”+”M2” 45.0 [1.77
]
System pressure “A”+”B” [1.77
X 0.5625-18UNF-2B Gauge port “M4”
[9/16 -18UNF-2B] Servo pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
238.0
M3
[9.39]
W
0
23.8 ] M4
[0.94
87.0
[3.45]
50.8 ]
[2.00
B
W
M4
A
0
Y
M5
Supply pressure
L1
[3.70]
94.0
Shuttle valve
[2.22]
56.0
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Split flange boss “A” Split flange boss “B”
DN 19 typ II 40 MPa series DN 19 typ II 40 MPa series
per ISO 6162 [SAE 0.75] per ISO 6162 [SAE 0.75]
4 thread: 0.375-16UNC-2B 4 thread: 0.375-16UNC-2B
L2 [3/8 -16UNC-2B] [3/8 -16UNC-2B]
19 [0.75] min. 19 [0.75] min.
full thread depth full thread depth
P001 966E
E 6.0
[0.24] Ø14.0 ± 0.2
B [0.55 ± 0.01]
R1.6
[2.23]
56.57
[0.06] .0
10
[5.91 ± 0.06]
Ø1 33]
Ø125.0 - 0.063
150.0 ± 1.6
[4.921 - 0.002]
Z [4.
Ø44.45
Ø85.0
[3.35]
[1.75]
ØD
ØA
[2.23]
56.57
ØG
Ø19.5 [0.77]
other side max.
9.0 17.0 screw head space
[0.35] [0.67]
C 32.5 56.57 56.57
Coupling may not protrude [1.28] [2.23] [2.23]
beyond this surface 150.0 ± 1.6
[5.91 ± 0.06] P001 810E
Cartridge Flange
51C060-1 Two Position Control, N1NN
Y W
Loop flushing
X shuttle valve
Charge pressure W
130.0
[5.13] relief valve
Gauge port “M4”
M4
System pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B
[1 1/16 -12UN-2B] B A
23.8
]
[0.94
[8.21]
208.5
Y
L1
70
]
[2.76
50.8
Gauge port “M2”
[2.00
[1.54] [1.54]
[1.57]
70
39.0 39.0
40.0
] System pressure “B”
[2.76
]
0.875-14UNF-2B
Gauge port “M1” [7/8 -14UNF-2B]
System pressure “A”
0.875-14UNF-2B
[3.91]
99.4
[7/8 -14UNF-2B]
Speed pick-up
Alternate position
Case drain “L2” min. angle stop Split flange boss “A”+”B”
1.0625-12UN-2B adjustment
50.0 DN 19 typ II 40 MPa series
[1 1/16 -12UN-2B] per ISO 6162 [SAE 0.75]
[1.97] 4 thread: 0.375-16UNC-2B
174.3 max. [3/8 -16UNC-2B]
[6.86 max.] 19 [0.75] min.
full thread depth
Y W
X
W
158.0
[6.21] Gauge port “M4”
M4
Y
L1
]
49.0
M4
shuttle valve [9/16 -18UNF-2B]
Charge pressure
relief valve
Control Start
M3
[1 1/16 -12UN-2B]
[6.77]
Supply pressure
172.0
A Shuttle valve
L1 Y Gauge port “M1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
System pressure “A”
M1
0.5625-18UNF-2B
50.8 ]
[2.00 [9/16 -18UNF-2B]
[1.60]
[1.54] [1.54]
41.0
39.0 39.0
M5
[9/16 -18UNF-2B]
[3.89]
[3.77]
99.0
96.0
L2
Alternate position
Case drain port “L2” min. angle stop Control mounting
1.0625-12UN-2B
adjustment surface
U
[1 1/16 -12UN-2B]
Gauge port “M7” U M7
Control pressure Split flange boss “A”+”B”
50.0 0.5625-18UNF-2B DN 19 typ II 40 MPa series Shaft centerline
X1
[1.97] [9/16 -18UNF-2B] per ISO 6162 [SAE 0.75]
4 thread: 0.375-16UNC-2B
[1.93]
49.0
209.0 [3/8 -16UNC-2B]
[8.24] 19 [0.75] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 70.0 ]
[2.76
70.0 ]
[2.76 .0 45.0
]
Gauge port “M1”+”M2” 45 [1.77
]
System pressure “A”+”B” [1.77
X 0.5625-18UNF-2B
Gauge port “M4”
Servo pressure max. angle
[9/16 -18UNF-2B]
0.5625-18UNF-2B
[9/16 -18UNF-2B]
179.0
W
M3
[7.03]
M4
0
23.8 ]
[0.94
W
B
50.8 ]
M4
[2.00
A
Y
0
L1
M5
Supply pressure
Shuttle valve
0.5625-18UNF-2B
[2.22]
56.0
P001 967E
[2.93]
74.5
R1.6
[0.06]
Ø160.0 - 0.025
[6.299 - 0.001]
M3
Z
Ø44.45
Ø134.0
Ø106.0
Ø90.0
[1.75]
[5.28]
[4.17]
[3.54]
ØD
ØA
H
ØG
[3.13]
79.5
Clea
min rance
.Ø
[9.53242.0
]
M4
94.0 System pressure max. angle
[3.69] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B 6
[8.62]
27.7 ]
218.9
[1 1/16 -12UN-2B]
B A
[1.09
Y
[3.37]
76.0
85.5
[2.99
[2.25
[1.76]
45.0
76.0 System pressure “B”
2
]
19° [2.99 1.0625-12UNF-2B
[1 1/16 -12UNF-2B]
Gauge port “M1”
System pressure “A”
[3.15]
80.0
1.0625-12UNF-2B
[4.20]
106.7
[1 1/16 -12UNF-2B]
Alternate position
Case drain “L2” min. angle stop Split flange boss “A”+”B”
1.0625-12UN-2B DN 25 typ II 40 MPa series
[1 1/16 -12UN-2B] adjustment
per ISO 6162 [SAE 1.00]
93.7 4 thread: 0.4375-14UNC-2B
[3.69] [7/16 -14UNC-2B]
278.2 max. 27 [1.06] min.
[10.95 max.] full thread depth
Y W
X
261.0 W
[10.28]
Gauge port “M4”
M4
Y
[4.58]
116.0
]
DN 25 typ II 40 MPa series 50.0 [1.97
] 79.0
per ISO 6162 [SAE 1.00] [1.97 ]
4 thread: 0.4375-14UNC-2B [3.11
[7/16 -14UNC-2B] 79.0
]
27 [1.06] min. [3.11
Split flange boss “B”
full thread depth
DN 25 typ II 40 MPa series
per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
Gauge ports “M1”+”M2” [7/16 -14UNC-2B]
27 [1.06] min.
System pressure “A”+”B” full thread depth
0.5625-18UNF-2B
[9/16 -18UNF-2B] P001 793E
M4
Gauge port “M3”
235.0 Servo pressure min. angle
[9.27] 0.5625-18UNF-2B
Loop flushing [9/16 -18UNF-2B]
shuttle valve
Charge pressure W
relief valve Control start
94.0 adjustment Supply pressure
[3.69] Shuttle valve
M3
Case drain “L1” 0.5625-18UNF-2B
1.0625-12UN-2B [9/16 -18UNF-2B]
[1 1/16 -12UN-2B]
A Gauge port “M1”
[7.19]
183.0
Y System pressure “A”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
M1
[3.37]
85.5
57.1 ]
[2.25
[1.76]
45.0
Gauge port “M5” Gauge port “M2”
5
19°
M5
Servo pressure supply System pressure “B”
6
27.7 ] 0.5625-18UNF-2B 0.5625-18UNF-2B
[1.09 [9/16 -18UNF-2B] [9/16 -18UNF-2B]
[3.15]
80.0
[4.20]
107.0
[4.00]
102.0
U
Alternate position
M7
Case drain “L2”
1.0625-12UN-2B min. angle stop Control Mounting
[1 1/16 -12UN-2B] adjustment Gauge port “M7” Surface Shaft centerline
X1
Control pressure U Split flange boss “A”+”B”
[1.93]
49.0
0.5625-18UNF-2B DN 25 typ II 40 MPa series
93.7 [9/16 -18UNF-2B]
[3.69] per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
318.0 [7/16 -14UNC-2B] Control pressure port “X1”
[12.52] 27 [1.06] min. 0.5625-18UNF-2B
full thread depth [9/16 -18UNF-2B]
Y 81.0
]
[2.01
81.0 51.0 Gauge port “M4”
]
[2.01 1.0 [2.01 ]
Servo pressure max. angle
Gauge port “M1”+”M2” 5
]
System pressure “A”+”B” [2.01 0.5625-18UNF-2B
[9/16 -18UNF-2B]
X 0.5625-18UNF-2B
[9/16 -18UNF-2B]
W
M4
282.0
M3
[11.09]
134.0
[5.26] 6 W
27.7 ]
[1.09
57.1 ]
[2.25
B
M4
Supply pressure
5
A
Shuttle valve
Y 0.5625-18UNF-2B
M5
[9/16 -18UNF-2B]
[4.58]
116.0
[2.39]
61.0
P001 794E
B
O-ring 3.00x116.00 FPM
[0.12x4.57]
R3.0
[0.12]
[2.25]
4x Ø14.5 ± 0.2
57.25
Ø126.975 ± 0.025
[0.57 ± 0.01]
[4.999 ± 0.001]
[5.91 ± 0.06]
150.0 ± 1.6
Z
Ø44.0
[1.75]
Ø80.0
[3.15]
ØD
ØA
[2.25]
57.25
Ø19.5 [0.77]
ØG
H
other side max.
screw head space
12.0 20.0
[0.49] [0.79]
C 57.25 57.25
[2.25] [2.25]
Coupling may not protrude
beyond this surface 150.0 ± 1.6
[5.91 ± 0.06] P001 812E
M4
System pressure max. angle
70.0 0.5625-18UNF-2B
[2.75] [9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B
6
[8.62]
218.9
[1 1/16 -12UN-2B] 27.7 ]
B A
[1.09
Y
76.0
[3.44]
87.5
57.1 ]
[2.25
[1.76]
45.0
76.0 System pressure “B”
2
]
19° [2.99 1.0625-12UNF-2B
[1 1/16 -12UNF-2B]
Gauge port “M1”
[3.01]
76.5
[4.20]
106.7
[1 1/16 -12UNF-2B]
Alternate position
Case drain “L2” min. angle stop Split flange boss “A”+”B”
1.0625-12UN-2B adjustment DN 25 typ II 40 MPa series
[1 1/16 -12UN-2B] per ISO 6162 [SAE 1.00]
109.8 4 thread: 0.4375-14UNC-2B
[4.32] [7/16 -14UNC-2B]
27 [1.06] min.
252.7 max. full thread depth
[9.95 max.]
W
Y
X
W
237.0
[9.33] Gauge port “M4”
M4
Y
[4.40]
112.0
]
DN 25 typ II 40 MPa series 50.0 [1.97
] 79.0
per ISO 6162 [SAE 1.00] [1.97 ]
4 thread: 0.4375-14UNC-2B [3.11
[7/16 -14UNC-2B] 79.0
]
27 [1.06] min. [3.11 Split flange boss “B”
full thread depth DN 25 typ II 40 MPa series
per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
[7/16 -14UNC-2B]
Gauge ports “M1”+”M2” 27 [1.06] min.
System pressure “A”+”B” full thread depth
0.5625-18UNF-2B
[9/16 -18UNF-2B] P001 795E
Charge pressure W
M4
relief valve
66.65 Control start
[2.62] adjustment
M3
Case drain “L1”
1.0625-12UN-2B
[1 1/16 -12UN-2B] A Gauge port “M1”
[7.19]
183.0
Y System pressure “A”
0.5625-18UNF-2B Supply pressure
[9/16 -18UNF-2B]
M1
[3.44]
Shuttle valve
87.5
0.5625-18UNF-2B
57.1 ]
[2.25
[1.76]
[9/16 -18UNF-2B]
45.0
Gauge port “M5” Gauge port “M2”
19° 5
M5
Servo pressure supply System pressure “B”
6
27.7 ] 0.5625-18UNF-2B 0.5625-18UNF-2B
[1.09 [9/16 -18UNF-2B] [9/16 -18UNF-2B]
[3.01]
76.5
[4.00]
102.0
[4.20]
107.0
Alternate position U
Case drain “L2” Control mounting M7
1.0625-12UN-2B min. angle stop Gauge port “M7” surface
[1 1/16 -12UN-2B] adjustment Control pressure
0.5625-18UNF-2B U Split flange boss “A”+”B” Shaft centerline
X1
109.8 [9/16 -18UNF-2B] DN 25 typ II 40 MPa series
[1.93]
[4.32] per ISO 6162 [SAE 1.00]
49.0
294.0 4 thread: 0.4375-14UNC-2B
[11.58] [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
81.0
]
[3.19
81.0
] 51
[3.19 1 ]
Gauge port “M1”+”M2” 51 [2.0 Gauge port “M4”
]
System pressure “A”+”B” [2.01 Servo pressure max. angle
0.5625-18UNF-2B 0.5625-18UNF-2B
[9/16 -18UNF-2B]
X [9/16 -18UNF-2B]
258.0
W
M3
[10.15] M4
96.0
[3.80]
6
27.7 ] W
[1.09
57.1 ]
[2.25
B
M4
5
A
Y Supply pressure
M5
Shuttle valve
0.5625-18UNF-2B
[4.40]
112.0
[9/16 -18UNF-2B]
Split flange boss “A”
[2.39]
61.0
P001 796E
R1.6
[0.06] 4x Ø14.0 ± 0.2
[2.5]
63.6
[0.55 ± 0.01]
Ø140.0 - 0.063
[5.512 - 0.002]
.0
[6.61 ± 0.06]
168.0 ± 1.6
10
Z Ø1 .33]
∅45.0
[1.75]
[4
ØD
ØA
ØG
[2.5]
63.6
H
10.0 19.0
Ø19.5 [0.77]
[0.39] [0.75]
other side max.
C 32.1 63.6 63.6 screw head space
[1.26] [2.5] [2.5]
Coupling may not protrude
beyond this surface 168.0 ± 1.6
[6.61 ± 0.06] P001 813E
Cartridge Flange
51C080-1 Two Position Control, N1NN
Y W
Loop flushing
X shuttle valve
Charge pressure
133.0 relief valve W
[5.24]
Gauge port “M4”
M4
System pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B
[1 1/16 -12UN-2B] 6
[8.62]
27.7 ]
218.9
B A
[1.09
L1
Y
76.0
57.1 ]
]
[2.25
[2.99
[1.77]
[1.77]
45.0
45.0
76.0
2
1.0625-12UNF-2B
45.0
[4.20]
106.7
[1 1/16 -12UNF-2B]
Speed pick-up
W
Y
X
W
159.0
[6.25] Gauge port “M4”
M4
Y
2
]
53.0
M4
Charge pressure Control start
[1.98]
relief valve adjustment
M3
Case drain “L1”
1.0625-12UN-2B
[1 1/16 -12UN-2B] A
[7.19]
183.0
Y W
L1
Supply pressure
M1
Shuttle valve
57.1 ]
Gauge port “M5” 0.5625-18UNF-2B
[1.77]
[2.25
[1.77]
45.0
45.0
[9/16 -18UNF-2B]
5
Servo pressure supply
M5
0.5625-18UNF-2B Gauge port “M2”
6
27.7 ] [9/16 -18UNF-2B] Gauge port “M1” System pressure “B”
[1.77]
[1.09
45.0
[4.20]
[4.00]
102.0
107.0
[9/16 -18UNF-2B]
Speed pick-up
Alternate position Control mounting
Case drain “L2”
1.0625-12UN-2B
Gauge port “M7”
U
surface U
[1 1/16 -12UN-2B] Control pressure Split flange boss “A”+”B”
0.5625-18UNF-2B M7
[9/16 -18UNF-2B] DN 25 typ II 40 MPa series
min. angle stop per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B Shaft centerline
X1
adjustment
215.0 [7/16 -14UNC-2B]
[1.93]
49.0
[8.45] 27 [1.06] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 81.0
]
[3.19
81.0
[3.19
] 51.0
]
51.0 [2.01
Gauge port “M1”+”M2” ]
[2.01
System pressure “A”+”B” Gauge port “M4”
0.5625-18UNF-2B
X [9/16 -18UNF-2B]
Servo pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
179.0
W
M3
[7.07]
M4
6
27.7 ]
[1.09 B
M4
57.1 ]
W
[2.25
A
Y
5
L1
M5
Supply pressure
Shuttle valve
Split flange boss “A” 0.5625-18UNF-2B
[2.39]
61.0
[9/16 -18UNF-2B]
19° DN 25 typ II 40 MPa series Split flange boss “B”
per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B DN 25 typ II 40 MPa series
[7/16 -14UNC-2B] per ISO 6162 [SAE 1.00]
27 [1.06] min. 4 thread: 0.4375-14UNC-2B
full thread depth [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth
P001 798E
45
[0.87 ± 0.01] screw head space
[3.33]
84.5
R1.6
[0.06]
Ø190.0 - 0.029
[7.48 - 0.001]
M3
Z Ø44.45
Ø108.0
Ø112.0
Ø143.0
Ø90.0
[1.75]
[4.25]
[4.41]
[3.54]
[5.71]
ØA
ØD
28.0
ØG
[1.10]
[3.35]
84.5
Clea
min rance
.Ø
[10.5267.5
3]
Y W
Loop flushing
X shuttle valve
Charge pressure
254.0
relief valve W
[10.01]
Gauge port “M4”
M4
System pressure max. angle
101.0 0.5625-18UNF-2B
[3.98] [9/16 -18UNF-2B]
[9.16]
27.7 ]
232.6
[1 1/16 -12UN-2B]
[1.09
B A
Y
[3.43]
87.0
57.1 ]
[2.25
Gauge port “M2”
[1.91]
77.0
48.0
2
]
19° [3.03 System pressure “B”
77.0 1.0625-12UNF-2B
]
[3.03 [1 1/16 -12UNF-2B]
Gauge port “M1”
[3.54]
90.0
[4.53]
115.0
1.0625-12UNF-2B
[1 1/16 -12UNF-2B]
Alternate position
Case drain “L2” min. angle stop
Split flange boss “A”+”B”
1.0625-12UN-2B adjustment
[1 1/16 -12UN-2B] DN 25 typ II 40 MPa series
per ISO 6162 [SAE 1.00]
101.0 4 thread: 0.4375-14UNC-2B
[3.98] [7/16 -14UNC-2B]
143.0 27 [1.06] min.
[5.63] full thread depth
301.2 max.
[11.82 max.]
Y W
X
281.0
[11.05]
W
Gauge port “M4”
M4
Y
2
[4.74]
121.0
M4
101.0 Control start
[3.98] adjustment
Case drain “L”
M3
1.0625-12UN-2B
[1 1/16 -12UN-2B]
W
A
[7.30]
185.0
Y
Supply pressure
Shuttle valve
[3.43]
M1
87.0
57.1 ]
[2.25
[9/16 -18UNF-2B]
[1.91]
49.0
Servo pressure supply
5
0.5625-18UNF-2B Gauge port “M2”
19°
M5
6 [9/16 -18UNF-2B] System pressure “B”
27.7 ] Gauge port “M1” 0.5625-18UNF-2B
[1.09 System pressure “A” [9/16 -18UNF-2B]
[4.53] max.
115 max.
0.5625-18UNF-2B
[3.54]
90.0
[9/16 -18UNF-2B]
[4.00]
103.0
Alternate position
U
Case drain “L2” min. angle stop Control mounting M7
1.0625-12UN-2B adjustment Gauge port “M7” surface
[1 1/16 -12UN-2B]
Control pressure U Shaft centerline
X1
Split flange boss “A”+”B”
0.5625-18UNF-2B
101.0
[1.93]
DN 25 typ II 40 MPa series
49.0
[9/16 -18UNF-2B]
[3.98] per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
143.0 [7/16 -14UNC-2B]
[5.63] Control pressure port “X1”
27 [1.06] min.
337.0 full thread depth 0.5625-18UNF-2B
[13.25] [9/16 -18UNF-2B]
Y 80.0
]
[3.15
80.0
] 50.0
[3.15 .0 ]
50 [1.97
]
[1.97
Gauge port “M1”+”M2”
X System pressure “A”+”B”
0.5625-18UNF-2B
Gauge port “M4”
Servo pressure max. angle
[9/16 -18UNF-2B] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
M3
300.0
[11.8] BA W
M4
134.0
6
[5.27] 27.7 ]
[1.09
57.1 ]
[2.25
M4
W
5
Y
M5
[4.74]
121.0
Supply pressure
Shuttle valve
Split flange boss “A”
[2.53]
0.5625-18UNF-2B
64.0
P001 800E
F Speed pick-up
E
Ø20.5 ± 0.2
B [0.81 ± 0.01]
O-ring 3.00x142.00 FPM
[0.12x5.59]
[3.18 ± 0.01]
80.8 ± 0.2
R3.0
[0.12]
Ø152.375 ± 0.025
[5.999 ± 0.001]
[7.87 ± 0.07]
200.0 ± 1.8
Z
Ø128.1
Ø100.0
[5.04]
[3.94]
Ø55.0
[2.17]
ØD
ØA
[3.18 ± 0.01]
80.8 ± 0.2
ØG
H
Ø30.0 [1.18]
other side max.
screw head space
12.45 22.0
[0.49] [0.87] 80.8 ± 0.2 80.8 ± 0.2
C [3.18 ± 0.01] [3.18 ± 0.01]
M4
69.05 System pressure max. angle
[2.72] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B
6
27.7 ]
[9.16]
232.8
[1 1/16 -12UN-2B]
[1.09
B A
Y
[3.68]
93.5
57.1 ]
[2.25
77.0
[1.92]
49.0
]
[3.03
2
19° 77.0
]
[3.03 Gauge port “M2”
Gauge port “M1” System pressure “B”
[3.48]
1.0625-12UNF-2B
88.5
[4.53]
115.0
1.0625-12UNF-2B
[1 1/16 -12UNF-2B]
Alternate position
min. angle stop
Case drain “L2” Split flange boss “A”+”B”
1.0625-12UN-2B adjustment
DN 25 typ II 40 MPa series
[1 1/16 -12UN-2B] per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
107.05 [7/16 -14UNC-2B]
[4.21] 27 [1.06] min.
268.2 max. full thread depth
[10.56 max.]
Y W
X
249.0 W
[9.81]
Gauge port “M4”
M4
Y
2
[4.99]
127.0
[2.27]
58.0
50.0
]
50.0 [1.97
Split flange boss “A” ]
[1.97 80.0
DN 25 typ II 40 MPa series ]
[3.15
per ISO 6162 [SAE 1.00] 80.0
]
4 thread: 0.4375-14UNC-2B [3.15 Split flange boss “B”
[7/16 -14UNC-2B]
27 [1.06] min. DN 25 typ II 40 MPa series
full thread depth per ISO 6162 [SAE 1.00]
Gauge ports “M1”+”M2” 4 thread: 0.4375-14UNC-2B
[7/16 -14UNC-2B]
System pressure “A”+”B” 27 [1.06] min.
0.5625-18UNF-2B full thread depth
[9/16 -18UNF-2B]
P001 801E
M4
69.05 Control start
[2.72] adjustment
M3
Case drain “L1”
1.0625-12UN-2B
[1 1/16 -12UN-2B] A W
[7.30]
185.0
Y
Supply pressure
[3.68]
93.5
M1
Shuttle valve
0.5625-18UNF-2B
57.1 ]
[2.25
Gauge port “M5”
[1.91]
[9/16 -18UNF-2B]
49.0
5
Servo pressure supply
19°
M5
0.5625-18UNF-2B
6 Gauge port “M1” Gauge port “M2”
27.7 ] [9/16 -18UNF-2B]
[1.09 System pressure “A” System pressure “B”
0.5625-18UNF-2B 0.5625-18UNF-2B
[3.48]
88.5
[4.50]
114.0
[4.06]
103.0
Alternate position
Case drain “L2” min. angle stop Gauge port “M7”
Control mounting
surface
U
1.0625-12UN-2B Control pressure
[1 1/16 -12UN-2B]
adjustment
0.5625-18UNF-2B U Split flange boss “A”+”B”
M7
[9/16 -18UNF-2B] DN 25 typ II 40 MPa series
107.05
per ISO 6162 [SAE 1.00] Shaft centerline
X1
[4.21]
305.0 4 thread: 0.4375-14UNC-2B
[1.93]
49.0
[12.00] [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 80.0
]
[3.15
80.0
[3.15
] 50.0
]
50.0 [1.97
]
Gauge port “M1”+”M2” [1.97
System pressure “A”+”B”
0.5625-18UNF-2B Gauge port “M4”
X [9/16 -18UNF-2B] Servo pressure max. angle
0.5625-18UNF-2B
268.0 [9/16 -18UNF-2B]
M3
[10.54]
W
BA
M4
111.0
[4.35]
6
27.7 ]
[1.09
57.1 ]
[2.25
M4
5
Y W
M5
[4.94]
125.0
Supply pressure
Split flange boss “A” Shuttle valve
[2.53]
64.0
P001 802E
X Speed pick-up
Mounting flange surface
flange 160 B4 HL
per ISO 3019/2
F
E 13.5
[0.53]
B
Ø18.0 ± 0.2
R2.5 [0.71 ± 0.01]
[2.78]
70.7
[0.10]
Ø160.0 - 0.063
[6.299 - 0.002]
[7.48 ± 0.07]
Z
190.0 ± 1.8
Ø116.0
Ø55.0
[4.57]
[2.17]
ØA
ØD
[2.78]
ØG
70.7
Ø30.0 [1.18]
other side max.
screw head space
9.0 22.0
[0.35] [0.87]
70.7 70.7
C 40.3 [2.78] [2.78]
Coupling may not protrude [1.59]
190.0 ± 1.8
beyond this surface [7.48 ± 0.07] P001 816E
Cartridge Flange
51C110-1 Two Position Control, N1NN
Y W
Loop flushing
X shuttle valve
Charge pressure
relief valve
W
140.0
[5.51] Gauge port “M4”
M4
System pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[9.18]
233.1
B A
[1.09
L1
Y
57.1 ]
[2.25
77.0
[1.92]
[1.89]
49.0
48.0
]
[3.03
2
77.0 Gauge port “M2”
]
[3.03 System pressure “B”
[1.89]
48.0
[4.53]
115.0
1.0625-12UNF-2B
[1 1/16 -12UNF-2B]
Speed pick-up
Alternate position
Case drain “L2” min. angle stop
1.0625-12UN-2B Split flange boss “A”+”B”
adjustment
[1 1/16 -12UN-2B] DN 25 typ II 40 MPa series
48.0 per ISO 6162 [SAE 1.00]
[1.89] 4 thread: 0.4375-14UNC-2B
185.3 max. [7/16 -14UNC-2B]
27 [1.06] min.
[7.3 max.] full thread depth
W
166.0
[6.55] Gauge port “M4”
System pressure max. angle
M4
0.5625-18UNF-2B
[9/16 -18UNF-2B]
6
27.7 ]
[1.09
B A
57.1 ]
[2.25
L1
2
[2.27]
50.0
]
19° DN 25 typ II 40 MPa series 50.0 [1.97
per ISO 6162 [SAE 1.00] ]
4 thread: 0.4375-14UNC-2B [1.97 80.0
]
[7/16 -14UNC-2B] [3.15
80.0
27 [1.06] min. ] Split flange boss “B”
full thread depth [3.15
DN 25 typ II 40 MPa series
per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
Gauge ports “M1”+”M2” [7/16 -14UNC-2B]
27 [1.06] min.
System pressure “A”+”B” full thread depth
0.5625-18UNF-2B P001 803E
[9/16 -18UNF-2B]
M4
48.0
Charge pressure [1.89] Control start
relief valve adjustment
M3
Case drain “L1”
1.0625-12UN-2B W
[7.30] max.
185.0 max.
A
[1 1/16 -12UN-2B]
Y
L1
Supply pressure
Gauge port “M2” Shuttle valve
M1
0.5625-18UNF-2B
57.1 ] System pressure “B” [9/16 -18UNF-2B]
[2.25
[1.91]
Gauge port “M5” 0.5625-18UNF-2B
49.0
5
Servo pressure supply [9/16 -18UNF-2B]
M5
N
6 0.5625-18UNF-2B
27.7 ] [9/16 -18UNF-2B] Gauge port “M1”
[1.09
[4.53] max.
115.0 max.
System pressure “A”
0.5625-18UNF-2B
[4.06]
103.0
[9/16 -18UNF-2B]
L2
Speed pick-up
Alternate position
U
Control mounting
Case drain “L2” Gauge port “M7” M7
min. angle stop surface
Control pressure
1.0625-12UN-2B
[1 1/16 -12UN-2B] adjustment 0.5625-18UNF-2B U Split flange boss “A”+”B” Shaft centerline
[9/16 -18UNF-2B]
X1
DN 25 typ II 40 MPa series
[1.93]
per ISO 6162 [SAE 1.00]
49.0
221.0 4 thread: 0.4375-14UNC-2B
[8.71] [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 80.0
]
[3.15
80.0
] 50.0
[3.15 ]
50.0 [1.97
]
Gauge port “M1”+”M2” [1.97
Gauge port “M4”
System pressure “A”+”B”
X 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Servo pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
M3
185.0
[7.29] BA W
M4
6
27.6 ]
[1.09
M4
W
57.1 ]
[2.25
Y
5
M5
Supply pressure
Shuttle valve
Split flange boss “A” 0.5625-18UNF-2B
[2.53]
64.0
P001 804E
45
°
Ø22.0 ± 0.3
[3.64]
R2.0
92.5
[0.87 ± 0.01]
[0.10]
Ø200.0 - 0.029
[7.874 - 0.001]
M3
Ø160.0
Ø112.2
Ø136.0
Ø55.0
[2.17]
[6.30]
[4.42]
[5.35]
ØA
ØD
ØG
[3.64]
92.5
Clea
min rance
.Ø
[11.5293.5
6]
C 121.3
Coupling may not protrude [4.78]
125.0 125.0
beyond this surface [4.92] [4.92]
Case drain “L1”
287.9
1.0625-12UN-2B
[1 1/16 -12UN-2B] 11.2 20.0 [11.33]
[0.44] [0.79] P001 817E
M4
[4.47] adjustment
Case drain “L1”
M3
1.3125-12UN-2B
[1 5/16-12UN-2B] A
W
[8.08]
205.0
Y
Supply pressure
L1
[3.82]
M1
97.0
[2.10]
53.0
5 0.5625-18UNF-2B System pressure “B” [9/16 -18UNF-2B]
19° [9/16 -18UNF-2B] 0.5625-18UNF-2B
M5
Gauge port “M1” [ /16 -18UNF-2B]
9
6
27.7 ] System pressure “A”
[1.09 0.5625-18UNF-2B
[3.82]
[4.37]
111.0
97.0
[4.94]
125.0
L2 [9/16 -18UNF-2B]
Alternate position U
Case drain “L2” Control mounting
min. angle stop Gauge port “M7”
M7
1.3125-12UN-2B surface
[1 5/16-12UN-2B] adjustment Control pressure
0.5625-18UNF-2B
U Split flange boss “A”+”B” Shaft centerline
X1
114.0 [9/16 -18UNF-2B] DN 25 typ II 40 MPa series
[1.93]
[4.47] per ISO 6162 [SAE 1.00]
49.0
376.0 4 thread: 0.4375-14UNC-2B
[14.82] [7/16 -14UNC-2B]
27 [1.06] min. Control pressure port “X1”
full thread depth
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 91.0
]
[3.58
91.0
] 60.0
[3.58 .0 ]
60 [2.36
]
[2.36
Gauge port “M1”+”M2”
X System pressure “A”+”B” Gauge port “M4”
0.5625-18UNF-2B Servo pressure max. angle
[9/16 -18UNF-2B] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
M3
313.0
[12.34] B A
W
6
27.7 ]
M4
165.0 [1.09
[6.51]
57.1 ]
[2.25
5
W
M4
Y
[5.68]
144.0
L1
M5
Supply pressure
Split flange boss “A” Shuttle valve
[2.52]
0.5625-18UNF-2B
64.0
P001 805E
E Speed pick-up
B
Ø30.0 [1.18]
O-ring 3.00x142.00 FPM other side max.
[0.12x5.59] screw head space
R3.0
[0.12]
[3.18]
80.8
Ø152.375 ± 0.025
[5.999 ± 0.001]
[7.87 ± 0.07]
200.0 ± 1.8
Z
Ø100.0
[3.94]
Ø55.0
[2.17]
ØA
ØD
ØG
[3.18]
80.8
H Ø20.5 ± 0.2
[0.81 ± 0.01]
12.45 22.0
[0.49] [0.87]
80.8 80.8
C [3.18] [3.18]
Coupling may not protrude 200.0 ± 1.8
beyond this surface [7.87 ± 0.07] P001 818E
M4
Control start
[3.21]
adjustment
Case drain “L1”
M3
1.3125-12UN-2B
[1 5/16 -12UN-2B]
W
A
[8.08]
205.0
Y
Supply pressure
[4.06]
103.0
M1
Shuttle valve
0.5625-18UNF-2B
57.1 ]
[2.25
Gauge port “M2”
[2.10]
[9/16 -18UNF-2B]
53.0
5 Gauge port “M5”
System pressure “B”
19° Servo pressure supply 0.5625-18UNF-2B
0.5625-18UNF-2B
M5
Gauge port “M1” [9/16 -18UNF-2B]
6 [9/16 -18UNF-2B]
27.7 ] System pressure “A”
[1.09 0.5625-18UNF-2B
[4.37]
111.0
[3.76]
95.5
[9/16 -18UNF-2B]
[4.94]
125.0
Alternate position Control mounting U
Case drain “L2” min. angle stop surface
1.3125-12UN-2B Gauge port “M7” M7
[1 5/16 -12UN-2B]
adjustment
Control pressure U Split flange boss “A”+”B”
121.5 0.5625-18UNF-2B DN 25 typ II 40 MPa series Shaft centerline
X1
[4.78] [9/16 -18UNF-2B] per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
[1.93]
345.0
49.0
[13.60] [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 91.0
]
[3.58
91.0
] 60.0
[3.58 ]
60.0 [2.36
]
[2.36
Gauge port “M1”+”M2”
X System pressure “A”+”B” Gauge port “M4”
0.5625-18UNF-2B
[9/16 -18UNF-2B] Servo pressure max. angle
0.5625-18UNF-2B
M3
[1.09
[4.80]
57.1 ]
[2.25
5
M4
Y W
[5.44]
138.0
M5
Supply pressure
Shuttle valve
[2.53]
0.5625-18UNF-2B
DN 25 typ II 40 MPa series [9/16 -18UNF-2B]
per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B Split flange boss “B”
[7/16 -14UNC-2B]
27 [1.06] min. DN 25 typ II 40 MPa series
full thread depth per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
[7/16 -14UNC-2B]
27 [1.06] min.
full thread depth
P001 806E
R1.6
[3.12]
[0.06]
79.2
.0
30
Ø1 .12)
Ø180.0 - 0.063
[7.087 - 0.002]
[8.35 ± 0.07]
212.0 ± 1.8
(5
Ø120.0
Ø55.0
[4.72]
[2.17]
ØA
ØD
[3.12]
ØG
79.2
H
Ø18.0 ± 0.2
[0.71 ± 0.01]
9.0 25.0
[0.35] [0.99]
C 79.2 79.2
40.0
[3.12] [3.12]
[1.59]
Coupling may not protrude 212.0 ± 1.8
beyond this surface [8.35 ± 0.07] P001 819E
Cartridge Flange
51C160 Proportional and Two-Position Control, HZB1
Y 84.0
]
[3.31
84.0
]
[3.31
X
Gauge port “M4”
Gauge port “M3” Servo pressure max. angle
146.0 0.5625-18UNF-2B
Servo pressure min. angle
[5.73] 0.5625-18UNF-2B [9/16 -18UNF-2B]
54.0 [9/16 -18UNF-2B]
Charge pressure [2.13] W
relief valve
M4
Loop flushing Control start
shuttle valve adjustment
Case drain “L1”
M3
1.3125-12UN-2B
[8.08]
205.0
[1 5/16 -12UN-2B]
A W
L1 Y Supply pressure
Shuttle valve
M1
57.1 ] Gauge port “M2” 0.5625-18UNF-2B
Gauge port “M5” [9/16 -18UNF-2B]
[2.25
[2.1]
53.0
51.0
M5
[9/16 -18UNF-2B] Gauge port “M1”
[2.01]
6
51.0
[4.94]
125.0
[4.37]
Alternate position 111.0
Case drain “L2”
1.3125-12UN-2B min. angle stop Gauge port “M7”
Control mounting U
adjustment surface
[1 5/16 -12UN-2B] Control pressure
0.5625-18UNF-2B
U M7
Split flange boss “A”+”B”
[9/16 -18UNF-2B] DN 25 typ II 40 MPa series Shaft centerline
X1
per ISO 6162 [SAE 1.00]
239.0 4 thread: 0.4375-14UNC-2B
[1.93]
49.0
[9.40] [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 91.0
]
[3.58
91.0
]
[3.58 60.0
]
60.0 [2.36
]
Gauge port “M1”+”M2” [2.36
System pressure “A”+”B” Gauge port “M4”
X 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Servo pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
M3
177.0
[6.96] B A M4 W
6
27.7 ]
[1.09
W
57.1 ]
[2.25
M4
Y
L1
Supply pressure
M5
Shuttle valve
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[2.52]
45
Ø22.0 ± 0.3
°
[0.87 ± 0.01]
[4.09]
104.0
Ø230.0 - 0.029
[9.055 - 0.001]
Z
Ø184.0
Ø142.0
Ø120.0
Ø55.0
[7.24]
[2.17]
Clea
[5.59]
[4.72]
ØA
ØD
min rance
. Ø3
[12.7 23.6
4]
[4.09]
104.0
ØG
Alternate position
C
Case drain “L2”
Coupling may not protrude 1.3125-12UN-2B 140.0 140.0
beyond this surface [1 5/16 -12UN-2B] [5.51] [5.51]
11.2 20.03 318.0 ± 2.0
[0.44] [0.79] [12.52 ± 0.08]
140.8 max.
[5.54 max.] P001 820E
M4
[5.18] Control start
Case drain “L1” adjustment
M3
1.3125-12UN-2B
[1 5/16-12UN-2B]
W
A
[9.39]
239.0
Y
Supply pressure
L1
M1
Gauge port “M5” Shuttle valve
0.5625-18UNF-2B
[4.45]
113.0
[2.44]
0.5625-18UNF-2B
62.0
8
[4.71]
120.0
[9/16 -18UNF-2B] [9/16 -18UNF-2B]
[4.45]
113.0
137.0
[5.4]
M5
L2
Alternate position
min. angle stop Control mounting U
adjustment Gage port “M7” surface M7
Case drain “L2”
1.3125-12UN-2B Control pressure
0.5625-18UNF-2B
U Split flange boss “A”+”B”
[1 5/16-12UN-2B] DN 32 typ II 40 MPa series Shaft centerline
[9/16 -18UNF-2B]
X1
131.5 per ISO 6162 [SAE 1.25]
[1.93]
4 thread: 0.5-13UNC-2B
49.0
[5.18]
429.0 [1/2 -13UNC-2B]
[16.89] 25 [0.98] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 99.0
]
[3.90
99.0
[3.90
] 65.0
]
65.0 [2.56
Gauge port “M1”+”M2” ]
[2.56
System pressure “A”+”B”
0.5625-18UNF-2B
Gauge port “M4”
X [9/16 -18UNF-2B]
Servo pressure max. angle
0.5625-18UNF-2B
359.0 [9/16 -18UNF-2B]
M3
[14.13]
B A W
182.0
M4
[7.15]
6
31.7 ]
[1.25
66.6 ]
[2.63
8
Y W
M4
L1
[6.11]
155.0
Supply pressure
Shuttle valve
M5
P001 808E
X
Mounting flange surface
Speed pick-up
flange 165-4 (SAE "E")
per ISO 3019/1
F
E Ø30.0 [1.18]
B other side max.
screw head space
O-ring 3.00x154.00 FPM
[0.12x6.06]
112.25
R3.0
[4.42]
[0.12]
Ø165.075 ± 0.025
[6.499 ± 0.001]
[10.24 ± 0.07]
260.0 ± 1.9
Z
Ø100.0
Ø118.0
[3.94]
[4.65]
Ø55.0
[2.17]
ØA
ØD
ØG
36.0
112.25
[4.42]
[1.42]
Ø20.5 ± 0.2
[0.81 ± 0.01]
15.65 25.0
[0.62] [0.98] 112.25 112.25
C [4.42] [4.42]
260.0 ± 1.9
Coupling may not protrude
[10.24 ± 0.07] P001 821E
beyond this surface
Dimension – Controls
Z Z Z
Electric brake Hydraulic brake
pressure defeat pressure defeat
AA TAD* TACA
Control pressure port “XB”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[2.94]
XB
XB
M3
M3
75.0
[2.17]
55.0
Shaft centerline
[2.17]
55.0
AB
AC
Flange
XA
XA
X1
X1
[5.05]
128.2
Control pressure port “XA”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Solenoid for
Shaft centerline
Electric brake pressure defeat
P001 838E
Solenoid Connectors
Magnet-Steckanschluss AMP Junior Timer
für DIN 46350 Two Pin Connector
(angebauter Stecker) (Supplied Connector)
2 1
Gegenstecker A B Mating Connector
Nr.: K09129 No.: K19815
Id.-Nr.: 514117 P001 752D Id.-No.: 508388 P001 751E
Shaft centerline
X1
[2.28]
58.0
X4
XB
JB
0.5625-18UNF-2B
Supply pressure [9/16 -18UNF-2B]
Shuttle valve
0.5625-18UNF-2B
JA Z [9/16 -18UNF-2B]
P001 839E
Dimension – Controls
Z Z Z
Electric brake Hydraulic brake
pressure defeat pressure defeat
AA THD* THC2
Control pressure port “XB”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[2.94]
XB
XB
M3
M3
75.0
[2.15]
54.5 Shaft centerline
[2.15]
54.5
AB
AC
Flange
XA
XA
X1
X1
[5.05]
128.2
Solenoid Connectors
Magnet-Steckanschluss AMP Junior Timer
für DIN 46350 Two Pin Connector
(angebauter Stecker) (Supplied Connector)
2 1
Gegenstecker A B Mating Connector
Nr.: K09129 No.: K19815
Id.-Nr.: 514117 P001 752D Id.-No.: 508388 P001 751E
Dimension – Controls
XA
Control pressure port “X1”
Shaft centerline 0.5625-18UNF-2B
[9/16 -18UNF-2B]
X1
[2.28]
58.0
X4
XB
JB
Control pressure port “XB”
Flange
0.5625-18UNF-2B
Supply pressure [9/16 -18UNF-2B]
Shuttle valve
0.5625-18UNF-2B
JA Z [9/16 -18UNF-2B]
P001 841E
M5
M3
Shaft centerline
AB
Solenoid for
Electric 2 position control
Gauge port “M3”
Shaft centerline Servo pressure min. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
P001 822E
Solenoid Connectors
Magnet-Steckanschluss AMP Junior Timer
für DIN 46350 Two Pin Connector
(angebauter Stecker) (Supplied Connector)
2 1
Gegenstecker A B Mating Connector
Nr.: K09129 No.: K19815
Id.-Nr.: 514117 P001 752D Id.-No.: 508388 P001 751E
Dimension – Controls
Ports with O-ring seal and inch threads shall be in accordance with ISO 11926/1.
Splite flange boss A and B per ISO 6162 is identical with high pressure series SAEJ518 code 62 (6000 psi).
Contact your Danfoss representative for specific installation drawings.
Electrohydraulic Two-Position Control – Options E1A5, E2A5, F1A5, F2A5 for 51 Frame Size
160, 250
Control options
E*A5/F*A5
Gauge port “M8”
Z
Internal control pressure
0.5625-18UNF-2B
[9/16 -18UNF-2B] Gauge port “M7”
Internal control pressure
0.5625-18UNF-2B
Shaft centerline [9/16 -18UNF-2B]
[2.82]
72.0
AD
Flange
AA Z P001 823E
Solenoid Connector
Magnet-Steckanschluss
für DIN 46350
(angebauter Stecker)
Gegenstecker A B
Nr.: K09129
Id.-Nr.: 514117 P001 752D
Z Z Z
Electric brake Hydraulic brake
pressure defeat pressure defeat
AA T*D* T*C2
[2.94]
XB
XB
M3
M3
74.6
[2.17]
55.0
Shaft centerline
[2.17]
55.0
AB
AC
Flange
XA
XA
X1
X1
[5.05]
128.2
Solenoid for
Shaft centerline Solenoid for
Electric brake
pressure defeat Electric 2 position control
Solenoid for
Electric 2 position control
P001 824E
Dimension – Controls
Solenoid Connectors
Magnet-Steckanschluss AMP Junior Timer
für DIN 46350 Two Pin Connector
(angebauter Stecker) (Supplied Connector)
2 1
Gegenstecker A B Mating Connector
Nr.: K09129 No.: K19815
Id.-Nr.: 514117 P001 752D Id.-No.: 508388 P001 751E
Solenoid for
Shaft centerline Electric 2 position control
[1.93]
49.0
HB
Flange
HA Z P001 825E
Solenoid Connector
Magnet-Steckanschluss
für DIN 46350
(angebauter Stecker)
Gegenstecker A B
Nr.: K09129
Id.-Nr.: 514117 P001 752D
Dimension – Controls
FJ
0.5625-18UNF-2B
FF
[9/16 -18UNF-2B]
FG
FH
FE
Gauge port “M7”
Control pressure Gauge port “M8”
FC 0.5625-18UNF-2B Pressure MS 3102C Control pressure
FB [9/16 -18UNF-2B] Connector 0.5625-18UNF-2B
compensator
override 0.875-20UNEF [9/16 -18UNF-2B]
FD [7/8 -20UNEF]
FA
Connectors
MS Connector Packard Weather-Pack
A
MS3102C-14S-2P 4 pin
(Supplied Connector) (Supplied Connector) B
D A
C B C
Mating Connector Mating Connector D
No.: K08106 No.: K03384
Id.-No.: 615062 P001 753E Id.-No.: 712208 P001 759E
Dimension – Controls
Electrohydraulic Proportional Control – Options L1B1, L2B1, L7B1 for 51 Frame Size
060, 080, 110, 160, 250
Control option
L*B1
Z
Solenoid for
Electric proportional
control
Shaft centerline
[1.93]
49.0
LB
Flange
LA
Z P001 827E
Solenoid Connectors
Magnet-Steckanschluss AMP Junior Timer
für DIN 46350 Two Pin Connector
(angebauter Stecker) (Supplied Connector)
2 1
Gegenstecker A B Mating Connector
Nr.: K09129 No.: K19815
Id.-Nr.: 514117 P001 752D Id.-No.: 508388 P001 751E
Shaft centerline
[2.82]
71.6
GE
Electric proportional
[4.33]
GD
110.0
Dimension – Controls
Solenoid Connector
AMP Junior Timer
Two Pin Connector
(Supplied Connector)
2 1
Mating Connector
No.: K19815
Id.-No.: 508388 P001 751E
Shaft centerline
[2.76]
Electric proportional
70
GE
[4.33]
GD
110.0
Solenoid Connector
AMP Junior Timer
Two Pin Connector
(Supplied Connector)
2 1
Mating Connector
No.: K19815
Id.-No.: 508388 P001 751E
Dimension – Controls
Ports with O-ring seal and inch threads shall be in accordance with ISO 11926/1.
Splite flange boss A and B per ISO 6162 is identical with high pressure series SAEJ518 code 62 (6000 psi).
Contact your Danfoss representative for specific installation drawings.
Hydraulic Proportional Control – Options HSA* for 51 Frame Size
060, 080, 110, 160, 250
Control option
HSA*
Z
Control pressure port “XA”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[2.3]
58.0
Shaft centerline Shaft centerline
BJ
BF
BH
BG
[4.47]
114
BE
Flange
Pressure compensator
BC Gauge port “M7” override
BB Control pressure Control pressure port “XB”
0.5625-18UNF-2B
BD Z [9/16 -18UNF-2B] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
BA P001 828E
Dimension – Controls
Shaft centerline
X1
[1.93]
49.0
EB
Flange
• Integrated Systems We offer expert worldwide support for our customers, ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also provide
• Joysticks and Control comprehensive global service for all of our components.
Handles
• Microcontrollers and Please contact the Danfoss Power Solution representative nearest you.
Software
• Open Circuit Axial Piston
Pumps
• Orbital Motors
• PLUS+1® GUIDE
• Proportional Valves
• Sensors
• Steering
• Transit Mixer Drives
Comatrol
www.comatrol.com
Local address:
Schwarzmüller-Inverter
www.schwarzmueller-
inverter.com
Turolla
www.turollaocg.com
Valmova
www.valmova.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Danfoss
Power Solutions
Danfoss Danfoss Danfoss (Shanghai) Co. Ltd.
Power Solutions US Company Power Solutions GmbH & Co. OHG Power Solutions ApS Building #22, No. 1000 Jin Hai Rd
2800 East 13th Street Krokamp 35 Nordborgvej 81 Jin Qiao, Pudong New District
Ames, IA 50010, USA D-24539 Neumünster, Germany DK-6430 Nordborg, Denmark Shanghai, China 201206
Phone: +1 515 239 6000 Phone: +49 4321 871 0 Phone: +45 7488 2222 Phone: +86 21 3418 5200
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.