Used for extension from fitting. 2. Prevention of the backflow of sewer gas
Elbows- ¼ bend, 45 degrees and (1/2 degree) 4. The drainage system must be provided with
90 degrees, to change the direction of water. a ventilation pipe that will convey gases to the
atmosphere where can do no harm to human
health.
TYPES OF VALVES 5. That except for water closet each fixture
Flush valve – Flashing water closets should be provided with suitable trap that will
prevent backflow of gases
Float valve- Filling water tanks
6. that the drainage water system must be Bacteriological process
vented, avoid siphonage or backflow of the
Sludge- semi-liquid substance accumulated at
water seal.
the bottom of the septic tank.(Sedimentation)
Scum- A floating substance at the septic tank
Types of Waste.
-Well and septic tank must be seventy-five feet
Solid Waste- Discharge by water closet (Toilet) away from each other.
Liquid Waste- Coming from various fixtures. The house drain
- Portion of the plumbing system that receives
discharges of all soil and waste within the
Types of Drainage piping
building.
1. Soil pipe- Pipe that conveys the discharge of
- Called also as the collection of line of a
black water (For solid waste) (with fecal matter)
plumbing system.
2. Waste pipe- A pipe that conveys the
-plumbing code on house drain.
discharge of only grey water (Liquid waste/free
of fecal water) (smaller than Soil pipe because - No water closet shall be discharged into a
of nature matter) drain less than 75mm or 3 pipe diameters.
-No more than two water closets shall
discharge into any 75mm horizontal soil
The Waste Pipe
branch, house drain, or house sewer.
- must be short, directed free from offsets, and
provided with ample cleanouts.
PLUMBING LAW (RA-1378)- Ensure public
- 2% Slope- meaning the pipe was installed
health and safety.
with inclined ratio of (2 centimeters per meter
length) 1. establish standards that will protect the
health of the community. faulty plumbing is a
-General rule, the vent stack must be extended
serious health hazard.
and terminated through the roof of the building.
2. with the increasing standardization of
-Should be extended no less than 2.00 meters
equipment and materials, plumbing codes in
above the roof
different areas of the country are tending more
and more toward uniformity.
SIGNS OF LEAK
1. Stains- on floor, ceiling, and walls.
2. Wet spots- beneath leaks from the ceiling
3. Visible mold
PLUMBING CODE
RA 1378- plumbing law of the Ph.
RA 6541 NATIONAL BUILDING CODE OF
THE PH.
RA 1378 -NATIONAL PLUMBING CODE OF
THE PH.
PURPOSE OF THE CODE
1. ESTABLISH STANDARDS
CLEANOUT