COMPANY PRESENTATION
While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility
can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or
modify the characteristics of its products described in this catalogue as standards and technology evolve.
2
02/2021
TECHNICAL INFORMATION
TABLE OF CONTENTS
Certifications
Material properties
Electrical stress
Screen earthing device
Overall dimensions of connectors
Dimensions and ratings of bushings
Electrical ratings
Test sequences
Jumpers and test leads
References
Enquiry sheet
02/2021
CERTIFICATIONS
02/2021
4
ATEX - IECEx ATEX - certificate IECEx certificate
Components intended for Conform with ATEX directive Conform with IEC standard
use on/in equipment or 2014/34/EU IEC 60079-0:2017
protective system intended for IEC 60079-7:2015
use in potentially explosive
atmospheres:
K440TB K944TB for rules and details of the IECEx Scheme visit www.iecex.com
Ex COMPONENT CERTIFICATE
K676LRA K400AR-6
Certificate No.: IECEx CML 20.0024U Page 1 of 3 Certificate history:
K300PB K900AR-1
Date of Issue: 2020-02-27
300SA K900AR-2
9320 Erembodegem
Belgium
400PB-XSA K900AR-3 This component is NOT intended to be used alone and requires additional consideration when incorporated into other equipment or
systems for use in explosive atmospheres (refer to IEC 60079-0).
K675BE K900AR-4
Type of Protection:
Marking: Ex eb IIC Gb
Ts = -20°C to +95°C
K400AR-3 K480TB
K400AR-4 K489TB
400A-24B K800PB Approved for issue on behalf of the IECEx R C Marshall
K400CP-SC K809PB
Certification Body:
K440CP K400BE
Signature:
(for printed version)
Date:
K670AR-2 K480BE 1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
K680CP K784TB
3. The Status and authenticity of this certificate may be verified by visiting www.iecex.com or use of this QR Code.
K484TB K909TB
Eurofins E&E CML Limited
Unit 1, Newport Business Park
New Port Road
Ellesmere Port, CH65 4LZ
United Kingdom
K440PB K909PB
K900DR-B-G K900BE
ELAB
Elab is the Nexans laboratory
accredited by BELAC to perform
electrical test programmes
according to the CENELEC HD
629.1 (IEC 60502-4) and EN
50393 standards for low and
medium voltage power accessories
from 300 volts up to 42 kV. The
certificate number is BELAC no.
144-TEST.
The ISO 17025 standard
prescribes the rules for the lab
accreditation. It specifies the
independency of the lab, the
necessary competence, the
organisation, the measurement
accuracy and the handling of the
instruments. Performing tests at
accredited labs means that these
tests are correctly performed,
documented and repeatable in
other accredited labs.
5
MATERIAL PROPERTIES
ELECTRICAL PROPERTIES
OZONE/CORONA
RESISTANCE
EPDM Silicone
Typical values The outstanding resistance to
Insulation Conductive Insulation corona is due to the ability of the
Dielectric strength (kV/mm) 33 - 24 EPDM rubber to withstand ozone
Dielectric constant 2.7 to 3.1 - 2.6 and other chemical compounds
Dissipation factor (x 10-3) 2.5 - 4 formed by discharges and its
Volume resistivity at 20 °C (Ohm-cm) 1014 50 1015
resistance to heat.
OTHER PROPERTIES
CHEMICAL RESISTANCE
EPDM Silicone Products made from EPDM
Typical values
Insulation Conductive Insulation rubber resist attacks made by
Specific gravity (kg/dm³) 1.33 1.12 1.15 many acids, alkalis, detergents,
Tensile strength (N/mm²) 4.8 11 8.5 phosphates, esters, ketones,
Shore hardness (Shore A) 65 80 47 alcohols and glycols. They give
Elongation (%) 400 450 700 particularly outstanding service
Abrasion resistance good excellent poor
in the presence of hot water and
Heat ageing good good good
high pressure steam. Like all
Temperature range (°C) -60 to +130 -60 to +130 -80 to +200
hydrocarbon-based elastomers,
Resistance to:
-U.V. good good good
EPDM is not resistant to
-Ozone excellent excellent excellent hydrocarbon solvents and oils or
-Sunlight outstanding outstanding outstanding chlorinated hydrocarbons.
-Water absorption very good very good excellent
-Solvent poor poor poor
-Hydrocarbon oil poor poor good
-Silicone oil good good poor
150 grams
7
ELECTRICAL STRESS
Fig. 2
100 %
Fig. 3
100 %
ELECTRICAL STRESS RELIEF
conductor
When the semi-conductive
screen is cut, the electrical field
core insulation
distribution changes radically. The
reinforcing
90 % 90 %
insulating surrounding air and the dielectric
portion of
90 % 90 %
80 % 80 %
termination material in the vicinity of the cut
80 % 80 %
70 % 70 %
screen become overstressed (Fig.
70 % 70 %
2) and breakdown of the cable
60 % 60 %
will soon occur. To avoid this, we
50 % 50 % control the equipotential lines by
60 % 60 %
40 % 40 %
installing a termination with a
conductive
50 % 50 %
portion of stress cone (Fig. 3), a termination
termination
40 %
30 %
40 %
30 % EQUIPOTENTIAL
30 % 30 %
with linear stress relief (Fig. 4) or a
LINES
separable connector (Fig. 5) at the
20 % 20 %
20 % 20 %
10 % 10 %
conductive
screen
10 % 10 %
end of the screen.
FLUX The terminations will make
LINES
sure that equipotential lines are
sufficiently far apart when they
finally emerge into the air and
Fig. 4 Fig. 5
100 %
that they will not cause ionization.
70 % 80 % 90 % 90 % 80 % 70 %
EQUIPO- elbow 0%
The separable connector keeps
conductor TENTIAL
LINES
connector 20 %
40 %
the equipotential lines inside the
60 % 60 %
60 %
80 %
cable/connector assembly in a
core
insulation 100 %
controlled way. This stress relief
is automatically built into all
the accessories by the precision
80 %
50 % 50 %
60 %
30 % 30 %
20 % 20 % 20 % 20 %
stress
relief tube 40 % 40 %
10 % 10 % equipment
bushing
FLUX
conductive LINES 60 % 60 %
screen
80 % 80 %
02/2021
8
100 %
THE VOLTAGE DETECTION Key
POINT
1 Conductive rubber cap Line potential
The connectors manufactured by
2 Metallic insert (capacitive test point)
Euromold are provided with a Ctc
3 EPDM conductive screen (earth potential)
capacitive test point: the voltage Test
4 EPDM insulation
detection point (VD point). This point
5 EPDM internal screen (line potential) Ctg Cm
enables a local check to confirm
6 Metallic insert (line potential)
that the product is de-energised
prior to disconnection (Use a high
resistance test device - approx.
1
250 MΩ).
2
The capacitive test point consists
of a metallic insert, moulded into Cm
the insulation and electrically 3 Ctc Ctg
CONNECTORS:
connected to a convenient external
4 152SR - 158LR
terminal. 400LR
5
9
SCREEN EARTHING DEVICE SELECTION GUIDE
APPLICATION
Terminations and separable
connectors require additional
earthing devices when installed
on some types of cable. Please
also check the product page in the
catalogue.
extruded
semi-
conductive
extruded screen extruded
semi- extruded semi-
conductive aluminium conductive
semi-
screen or copper screen
conductive
tubular
screen screen,
copper tape laid aluminium
screen copper wire or copper
longi-
screen tape
tudinally
screen,
laid
outer outer outer longi-
sheath sheath sheath tudinally
ALUPE NF C 33-226
02/2021
10
KIT DESCRIPTION
KIT MT/RS 1
1. Tinned braid with solder block.
for use with copper tape screened 2. Constant force spring.
cables. 3. Roll of sealing mastic.
2 3
2 3
KIT 020, KIT 025 & KIT 050 1. Two cleating collars.
for use with longitudinal aluminium 1 2. Tinned copper earth braid with
or copper foil screened cables. solder block, copper wire and
terminal lug soldered to a
2 tinned copper plate.
3. Strip of sealing mastic.
11
OVERALL DIMENSIONS
OF SEPARABLE CONNECTORS
OVERALL DIMENSIONS
These diagrams show the
dimensions of the connectors
in assembled position and the
minimum dimensions necessary
to disconnect.
SEPARABLE CONNECTORS
WITH INTERFACE A
200SR
340
280
245
185
-M10 for standard applications
-M12 for applications acc. AS038
Dia. 55
100 max.
200LR
190
Dia. 55 130
80
100 max.
200
110
In mm.
02/2021
12
SEPARABLE CONNECTORS
WITH INTERFACE B
400LR
300 290
270
210
193
130
Dia. 77 250
115 max 315±10
400TE
Dia. 86
62
Dia. 75 355
255
250
220
150
110
Dia. 80 270
110 max 335 ±10
In mm.
13
SEPARABLE CONNECTORS
WITH INTERFACE C
480TB
Dia. 86
28 Dia. 65
290
215
184
181
143
110
Dia. 232
75
295±10
400TB
Dia. 86
62
Dia. 75
320
250 255
220
150
110
Dia. 80 270
335 ±10
484TB
Dia. 92
Dia. 86
28 Dia. 92
290
266 185
183
156
110
Dia. 80 275
360±10
In mm.
14
02/2021
489TB
Dia. 115
Dia. 86
28
Dia. 115
290
266 185
183
156
110
Dia. 80 360
445±10
480TB+800PB/804PB
Dia. 86
28
340
110
287 290
215
110
Dia. 232
75
295±10
480TB+809PB
Dia. 86
28
350
120
287 300
215
110
In mm.
Dia. 232
75
295±10
15
440TB
Dia. 86
62
Dia. 92
330
266 260
220
156
110
Dia. 80 275
355±10
SEPARABLE CONNECTORS
WITH INTERFACE D
676LRA
Dia. 86
62
Dia. 92
342
280 250
212
150
106
Dia. 80 275
355±10
SEPARABLE CONNECTORS
WITH INTERFACE E - 5/8"
784TB
Dia. 86
28
325
213
215
130
16 Dia. 80 270
355±10 In mm.
02/2021
SEPARABLE CONNECTORS
WITH INTERFACE F
909TB
325
250
909TB+909PB
200
550
170 425
220
120
380
Dia. 110
445
In mm.
17
DIMENSIONS & RATINGS
OF EQUIPMENT BUSHINGS
DIMENSIONS
These diagrams show the
dimensions of the interfaces of Dia. 56±0.2
EN 50180:2010 and
0
pin 14 -0.04 M16 x 2 - 6H 0
1.5 -0.5
EN 50181:2010.
29
Dia. 32.5±0.2 min
40
+0.1 min
Dia. 31 - 0.3
Dia. for
+0.02
pin 7.9 - 0.05
90±0.2 90±0.2
0
48 -0.2
9 11 11
min min min
29
min
103.7±0.2
14.8 14.8
min min
18
ELECTRICAL RATINGS
APPLICATION
The voltage, current and routine
test ratings mentioned below are
at least at the same level of the
CENELEC standards.
The actual maximum withstand
level of the products are higher
than these ratings.
For compliance with other
standards, refer to our local
representative.
VOLTAGE
CURRENT
Overload
300 A 600 A 800 A 1000 A 1500 A - Same as cable
(8 h in 24 h period)
ROUTINE TESTS
- K M P
Test level
(12 kV) (24 kV) (36 kV) (42 kV)
19
02/2020
TEST SEQUENCES
FOLLOWING IEC 60137 and TS0030
EQUIPMENT BUSHINGS
Test sequences following
IEC 60137 and internal test
specification TS0030.
All our designs have
been validated using this
international standard. These
values do not necessarily reflect
the maximum levels. IEC 60137 TS0030
Test reports are available upon
4 samples 4 samples
request.
Partial discharges
(ambient temperature) Thermal shock
max. 10 pC @ 2 Ur/√3 10 cycles of 4 h @ 100° C
and 4 h @ -30° C
Cantilever
load of 300 N (Ir ≤ 800 A) or 1000 N Examination
(Ir > 800 A) - 1 min
at both ends of bushing
AC voltage dry
15 min @ 2.5 Ur/√3
Partial discharges
(elevated & ambient temperature)
max. 10 pC @ 2 Ur/√3
Examination
02/2021
20
TESTFOLLOWING
SEQUENCESCENELEC 629.1
TERMINATIONS
Test sequences following HD 629.1
Table 3 (indoor terminations) and
Table 4 (outdoor terminations).
All our designs have been
validated using this international A1 A2 A3
standard. These values do not 4 samples 3 samples 3 samples
necessarily reflect the maximum
levels.
Test reports are available upon DC voltage dry DC voltage dry (Indoor only)
15 min @ 6 U0 15 min @ 6 U0 Humidity
request.
300 h @ 1.25 U0
AC voltage dry AC voltage dry
5 min @ 4.5 U0 5 min @ 4.5 U0 (Outdoor only)
Salt fog
1000 h @ 1.25 U0
(Outdoor only) Thermal short circuit
AC voltage wet (conductor)
1 min @ 4 U0 2 x 250 °C - 1 s Examination
Partial discharges
(elevated & ambient
temperature)
max. 10 pC @ 2 U0
AC voltage dry
15 min @ 2.5 U0
Examination
21
TEST SEQUENCES
FOLLOWING CENELEC 629.1
JOINTS
Test sequences following
HD 629.1 Table 5.
All our designs have been
B1 B2
validated using this international
standard. These values do not 4 samples 3 samples
necessarily reflect the maximum
levels.
DC voltage dry DC voltage dry
Test reports are available upon
15 min @ 6 U0 15 min @ 6 U0
request.
Partial discharges
(elevated & ambient temperature) AC voltage dry
max. 10 pC @ 2 U0 15 min @ 2.5 U0
AC voltage dry
15 min @ 2.5 U0
Examination
02/2021
22
TESTFOLLOWING
SEQUENCESCENELEC 629.1
SCREENED SEPARABLE
CONNECTORS
Test sequences following D1 D2 D3
HD 629.1 Table 7. 4 samples 3 samples 1 sample
All our designs have been
validated using this international
standard. These values do not DC voltage dry DC voltage dry Operating eye
necessarily reflect the maximum 15 min @ 6 U0 15 min @ 6 U0 Axial: 1300 N - 1 min
levels. Torque: 14 Nm
Test reports are available upon
AC voltage dry AC voltage dry
request. Partial discharges
5 min @ 4.5 U0 5 min @ 4.5 U0
(ambient temperature)
max. 10 pC @ 2 U0
Partial discharges Thermal short circuit
(ambient temperature) (screen)
max. 10 pC @ 2 U0 Examination
Screen fault
AC voltage dry current initiation
15 min @ 2.5 U0
23
JUMPERS AND TEST LEADS
APPLICATION
Jumpers are prefabricated lengths
of cable on which separable
connectors or terminations are
installed on each end. Jumpers
are used as fixed solutions in
windturbines, transformers,...
Test leads are typically used
to perform tests on electrical
installations, transformers,
motors...
DESIGN
Jumpers comprise:
1. Connector or termination
adapted to the chosen interface
type and chosen voltage class.
6/10 (12) kV
2. Cable length. 6.35/11 (12) kV
3. A screen wire finishing with an 8.7/15 (17.5) kV
earthing lug is standard. Other 12/20 (24) kV
finishings are available upon 12.7/22 (24) kV
request. 18/30 (36) kV
19/33 (36) kV
All Jumpers are standard tested 20.8/36 (42) kV
for AC withstand and partial 26/45 (52) kV
discharge before leaving the
factory. Other tests can be done
on request. Up to 52 kV
02/2021
24
ENQUIRY SHEET
Side A Side B
L2 L2
L1
6. Position contact surface side B: In line with side A 90° angle with side A
Other:......................................................
9. Remarks:
............................................................................................................................................................
............................................................................................................................................................
............................................................................................................................................................
............................................................................................................................................................
............................................................................................................................................................
25
REFERENCES
POWER NETWORKS
Nexans contributes to the
reliability and security of energy
networks around the world by
increasing capacity and reducing
technical and non-technical losses
through affordable, state-of-the-
art technology.
Some of our main clients in this
sector are EDF, RWE, Endessa,
E-on, Iberdrola, ENEL, BKW Bern.
02/2021
26
WIND TURBINES AND WIND
FARMS
Nexans is, with its GPH®,
EUROMOLD® and Windlink
product lines, an important
partner in wind energy projects.
In Germany we supply thousands
of connectors and sleeves to the
leading OEMs in wind turbines
and power utility applications.
Prefabricated jumpers -pretested
in the factory to assure immediate
and fault-free installation- have
been supplied to GE Wind, Vestas
and others.
Address:
Zuid III - Industrielaan 12
B-9320 EREMBODEGEM - AALST - BELGIUM
Tel.:
Tel.: +32 (0)53 850 220
E-Mail: sales.euromold@nexans.com E-Mail:
CABLE DATA
Cable manufacturer: .................................................................................................................................... / Cable identification: .................................................................................
Cable description:
& Conductor material: Al Cu
Round Sector shaped Solid Stranded Class 5
Conductor size: ................................... mm2 (16 - 25 - 35 - 50 - 70 - 95 - 120 - 150 - 185 - 240 - 300 - 400 - 500 - 630 - 800 - 1000 mm2)
02/2021
Nexans Network Solutions N.V. - Div. Euromold
Zuid III, Industrielaan 12, B-9320 Erembodegem
Tel.: +32(0)53 85 02 11 • sales.euromold@nexans.com • www.euromold.be