of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification System for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Equipment: Three-phase asynchronous tube cooled motors and generators type W22Xdb B...T... 500... up to 710...or
W22Xdb M...T... 500... up to 710...
Optional accessory:
Type of Protection: db, db eb, db ia, db ib, db eb ia, db eb ib, tb, ia tb, ib tb
Marking: Ex db IIB T4 or T3 Gb, Ex db eb IIB T4 or T3 Gb, Ex db ia IIB T4 or T3 Gb, Ex db eb ia IIB T4 or T3 Gb, Ex db ib IIB T4
or T3 Gb, Ex db eb ib IIB T4 or T3 Gb
Ex tb IIIC T125°C or T135°C Db, Ex ia tb IIIC T125°C or T135°C Db, Ex ib tb IIIC T125°C or T135°C Db
Signature:
(for printed version)
Date:
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended
STANDARDS :
The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards
IEC 60079-1:2014-06 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:7.0
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Edition:6.0
IEC 60079-31:2013 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
Edition:2
IEC 60079-7:2017 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
Edition:5.1
This Certificate does not indicate compliance with safety and performance requirements
other than those expressly included in the Standards listed above.
Test Report:
FR/INE/ExTR14.0068/01
EQUIPMENT:
Equipment and systems covered by this Certificate are as follows:
Range of three-phase asynchronous motor with frame in welded steel and endshields in welded steel or cast iron. Motors can be fitted with
different terminal boxes and auxiliary boxes protected by flameproof enclosure or by increased safety. This equipment is also protected by
type protection "tb" for using in dust explosive atmospheres.
The motor may be designed with one up to four speed. Mounting position of motor can be either horizontal or vertical.
The terminal boxes made in cast iron, steel or stainless steel can be fitted directly on the motors or by an adaptor. Terminal boxes can be
mounted on the top or left/right side, located in any position of a 180° range around the upper part of the frame.
Terminal box or auxiliary boxes don’t communicate with the motor, the compartments are separated by bushing and/or cable glands covered
by Ex component. As a variation the connection can be made through a blanking cap with an unterminated cable. In this case the terminal
boxes can be supplied in separated.
Temperature sensors, with or without certification, may be incorporated in the stator windings and/or in the bearings. Heating resistances, with
or without certification, may be located inside of the motor mounted on each end of the frame or mounted on each end of the winding coil
heads. Heating resistances could be also mounted inside the terminal boxes protected by flameproof enclosures.
The motor could be fitted with intrinsic safety transmitters and sensors for thermal protection and for detection and control of vibrations. They
could be fitted on or inside the motor and the connections of these devices are made in the terminal boxes.
Motors supplied through a frequency inverter and motors with separate ventilation are always fitted with temperature sensors.
The motors get the degrees of protection IP55, IP56, IP65 or IP66 according to IEC 60034 - Part 5.
The terminal boxes type CG47, CEFGH340, CEFGH500, WTBX-XS, WTBX-S, WTBX-M, WTBX-L and WTBX-XL get the degrees of
protection IP66 in accordance with IEC 60529.
The motor and/or terminal boxes can be fitted with different Ex components. All components are stipulated on the descriptive documents.
As a variant, instead of cylindrical flameproof joint, labyrinth flameproof joints can be used between the inner bearing caps and the labyrinth
rings mounted on the shaft or manufactured on the shaft itself.
A drain and breathing device can be mounted on the motor or on the terminal boxes.
• Extension of ambient temperature to -55°C for size 500 up to 710 (I, IIB, IIIC).
• Change of designation W22Xdb
• Addition of Santo Tirso address as additional manufacturing location.
• Addition of shaft with sleeving.
• Addition of terminal boxes Ex eb certified as component covered by the certificate IECEx BAS 14.0175U and IECEx BAS 16.0129U.
• Standards update : IEC 60079-0:2017, IEC 60079-1:2014, IEC 60079-7:2017.
Annex:
Maximum frequencies:
Without frequency inverter : 50 Hz or 60 Hz.
With frequency inverter : Up to 150Hz.
MARKING
Marking has to be readable and indelible; it has to include the following indications:
• WEGeuro Indústria Eléctrica S.A
• 4470-605 MAIA or 4780-165 SANTO-TIRSO
• W22XdbB…T… (*) or W22XdbM...T… (*)
• IECEx INE 12.0010X
• (Serial number)
• Ex db IIB T4 or T3 Gb or Ex db eb IIB T4 or T3 Gb or Ex db ia IIB T4 or T3 Gb or Ex db eb ia IIB T4 or T3 Gb or Ex db ib IIB T4 or
T3 Gb or Ex db eb ib IIB T4 or T3 Gb Ex db I Mb or Ex db eb I Mb or Ex db ia I Mb or Ex db eb ia I Mb or Ex db ib I Mb or
Ex db eb ib I Mb
• Ex tb IIIC T125°C or T135°C Db or Ex ia tb IIIC T125°C or T135°C Db or Ex ib tb IIIC T125°C or T135°C Db
• IP65 or IP66
• T.amb: (**)
• T.Cable: (***)
• Cable entries: (type and size)
• WARNINGS:
o DO NOT OPEN WHEN ENERGIZED.
o DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT.
When the terminal box is protected by increased safety the following indications:
• (rated voltage and rated current and/or rated power)
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0010X
IECEx INE 12.0010X-02_Annex.pdf Issue No.: 02
Page 2 of 5
Annex: IECEx INE 12.0010X-02_Annex.pdf
When the terminal box is located outside of the motor and connected with a cable to the motor the following indications:
• IECEx INE 12.0010X
• Ex db IIB T4 or T3 Gb, Ex eb IIB T4 or T3 Gb,
• Ex db ia IIB T4 or T3 Gb, Ex db ib IIB T4 or T3 Gb, Ex eb ia IIB T4 or T3 Gb, Ex eb ib IIB T4 or T3 Gb
•
• Ex db I Mb, Ex db eb I Mb
• Ex db ia I Mb, Ex db eb ia I Mb, Ex db ib I Mb, Ex db eb ib I Mb
•
• Ex tb IIIC T125°C or T135°C Db, Ex ia tb IIIC T125°C or T135°C Db, Ex ib tb IIIC T125°C or T135°C Db
• IP65 or IP66
• Rated voltage and rated current and/or rated power are mandatory only for "Ex eb" version
•
• WARNINGS:
o DO NOT OPEN WHEN ENERGIZED.
o DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT.
(*) Type is completed by numbers and letters corresponding to the manufacturer variations.
(**) Mandatory mention when the range of the ambient temperatures differs from -20°C, -30°C, -40°C, -55°C to +40°C, +50°C, +60°C
(***) 85°C for ambient 50°C or 95°C for ambient 60°C when the cable glands are fitted on the terminal box.
95°C for ambient 40°C, 105°C for ambient 50°C or 115°C for ambient 60°C when the cable glands are fitted on the blanking cover of
motors supplied by flying leads.
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0010X
IECEx INE 12.0010X-02_Annex.pdf Issue No.: 02
Page 3 of 5
Annex: IECEx INE 12.0010X-02_Annex.pdf
In accordance with clause 16.1 of the IEC 60079-1 standard, each equipment defined above has to have successfully passed, before delivery, an
overpressure test of a period comprised between 10 and 60 seconds under:
Pressure
In accordance with § 16.2 of the IEC 60079-1 standard, the following terminal boxes defined above are exempted of routine test due to the fact
that they have undergone a static type test at 4 times the reference pressure under:
Pressure
In accordance with clause 7.1 of the IEC 60079-7 standard, the intercalary and the terminal boxes type CG47, CEFGH340, CEFGH500, WTBX-
XS, WTBX-S, WTBX-M and WTBX-L protected by increased safety must have successfully passed before delivery a dielectric strength test on
each of the different circuits of the connection units, performed according to the relevant standards, the supply voltage shall be applied during one
minute.
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0010X
IECEx INE 12.0010X-02_Annex.pdf Issue No.: 02
Page 4 of 5
Annex: IECEx INE 12.0010X-02_Annex.pdf
LIST OF THE COMPONENT INTENDED TO BE INSTALLED ON THE MOTOR AND/OR TERMINAL BOXES