You are on page 1of 9

IECEx Certificate

of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification System for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

Certificate No.: IECEx INE 12.0011X Page 1 of 4 Certificate history:


Issue 0 (2016-08-30)
Status: Current Issue No: 1

Date of Issue: 2020-03-26

Applicant: WEGeuro Indústria Eléctrica S.A


Rua Eng. Frederico Ulrich
Zona Industrial da Maia, Sector V
4470-605 Maia
Portugal

Equipment: Three-phase asynchronous tube cooled motors and generators type W22XdbC...T... 500 up to 710

Optional accessory:

Type of Protection: db, db eb, db ia, db ib, db eb ia, db eb ib, tb, ia tb, ib tb

Marking: Ex db IIC T4 or T3 Gb, Ex db eb IIC T4 or T3 Gb


Ex db ia IIC T4 or T3 Gb, Ex db eb ia IIC T4 or T3 Gb
Ex db ib IIC T4 or T3 Gb, Ex db eb ib IIC T4 or T3 Gb

Ex tb IIIC T125°C or T135°C Db


Ex ia tb IIIC T125°C or T135°C Db
Ex ib tb IIIC T125°C or T135°C Db

Approved for issue on behalf of the IECEx Thierry HOUEIX


Certification Body:

Position: Ex Certification Officer

Signature:
(for printed version)

Date:

1. This certificate and schedule may only be reproduced in full.


2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting www.iecex.com or use of this QR Code.

Certificate issued by:


INERIS
Institut National de l'Environnement Industriel et des Risques
BP n2 / Parc Technologique ALATA
F-60550 Verneuil-en-Halatte
France
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0011X Page 2 of 4

Date of issue: 2020-03-26 Issue No: 1

Manufacturer: WEGeuro Indústria Eléctrica S.A


Rua Eng. Frederico Ulrich
Zona Industrial da Maia, Sector V
4470-605 Maia
Portugal

Additional WEGeuro - Indústria Eléctrica, S.A


manufacturing Rua Antonio Joaquim Campos
locations: Monteiro, n°510
Santa Cristina do Couto
4780-165 Santo Tirso
Portugal

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended

STANDARDS :
The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards

IEC 60079-0:2017 Explosive atmospheres - Part 0: Equipment - General requirements


Edition:7.0

IEC 60079-1:2014-06 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:7.0

IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Edition:6.0

IEC 60079-31:2013 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
Edition:2

IEC 60079-7:2017 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
Edition:5.1

This Certificate does not indicate compliance with safety and performance requirements
other than those expressly included in the Standards listed above.

TEST & ASSESSMENT REPORTS:


A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in:

Test Report:
FR/INE/ExTR14.0068/01

Quality Assessment Report:


GB/BAS/QAR07.0032/08
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0011X Page 3 of 4

Date of issue: 2020-03-26 Issue No: 1

EQUIPMENT:
Equipment and systems covered by this Certificate are as follows:

Range of three-phase asynchronous motor with frame in welded steel and endshields in welded steel or cast iron. Motors can be fitted with
different terminal boxes and auxiliary boxes protected by flameproof enclosure or by increased safety. This equipment is also protected by
type protection "tb" for using in dust explosive atmospheres.

The motor may be designed with one up to four speed. Mounting position of motor can be either horizontal or vertical.

The terminal boxes made in cast iron, steel or stainless steel can be fitted directly on the motors or by an adaptor. Terminal boxes can be
mounted on the top or left/right side, located in any position of a 180° range around the upper part of the frame.

Cooling types can be IC511, IC516 or IC518 according to IEC 60034-6.

Terminal box or auxiliary boxes don’t communicate with the motor, the compartments are separated by bushing and/or cable glands covered
by Ex component. As a variation the connection can be made through a blanking cap with an unterminated cable. In this case the terminal
boxes can be supplied in separated.

Temperature sensors, with or without certification, may be incorporated in the stator windings and/or in the bearings. Heating resistances, with
or without certification, may be located inside of the motor mounted on each end of the frame or mounted on each end of the winding coil
heads. Heating resistances could be also mounted inside the terminal boxes protected by flameproof enclosures.

The motor could be fitted with intrinsic safety transmitters and sensors for thermal protection and for detection and control of vibrations. They
could be fitted on or inside the motor and the connections of these devices are made in the terminal boxes.

Motors supplied through a frequency inverter and motors with separate ventilation are always fitted with temperature sensors.

The motors get the degrees of protection IP55, IP56, IP65 or IP66 according to IEC 60034 - Part 5.

The terminal boxes type CG47, CEFGH340, CEFGH500, WTBX-XS, WTBX-S, WTBX-M, WTBX-L and WTBX-XL get the degrees of
protection IP66 in accordance with IEC 60529.

The motor and/or terminal boxes can be fitted with different Ex components. All components are stipulated on the descriptive documents.

As a variant, instead of cylindrical flameproof joint, labyrinth flameproof joints can be used between the inner bearing caps and the labyrinth
rings mounted on the shaft or manufactured on the shaft itself.

A drain and breathing device can be mounted on the motor or on the terminal boxes.

SPECIFIC CONDITIONS OF USE: YES as shown below:


• The screws used for the assembly of the various parts of explosion-proof enclosures must be of quality higher or equal to class 12.9 or
stainless steel A2-70 or A4-80.
• The dimensions of flameproof joints are different from the values specified in the tables of the IEC 60079-1 standard. For any repair,
contact the manufacturer.
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0011X Page 4 of 4

Date of issue: 2020-03-26 Issue No: 1

DETAILS OF CERTIFICATE CHANGES (for issues 1 and above)


Issue 1:

• Extension of ambient temperature to -55°C for size 500 up to 630.


• Change of designation W22Xdb.
• Addition of Santo Tirso address as additional manufacturing location.
• Addition of shaft with sleeving.
• Addition of terminal boxes Ex eb certified as component covered by the certificate IECEx BAS 14.0175U and IECEx BAS 16.0129U.
• Standard update : IEC 60079-0:2017, IEC 60079-1:2014, IEC 60079-7:2017.

Annex:

IECEx INE 12.0011X-01_Annex.pdf


IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0011X
IECEx INE 12.0011X-01_Annex.pdf Issue No.: 01
Page 1 of 5
Annex: IECEx INE 12.0011X-01_Annex.pdf

PARAMETERS RELATING TO THE SAFETY

Maximum supply voltages (for 50Hz or 60Hz):


Low voltage : 220 V to 1140V.
Medium voltage : up to 6600V.
High voltage : up to 13800 V or 11000V when the motor is fitted with terminal box protected by increased safety.

Maximum frequencies:
Without frequency inverter : 50 Hz or 60 Hz.
With frequency inverter : Up to 150Hz.

Maximum powers of motors:


Standard version, service S1
Low voltage : 630 kW to 4500 kW.
Medium voltage : 630 kW to 4500 kW.
High voltage : 500 kW to 3550 kW.
For special versions the different parameters can be adapted.
Maximum powers of internal Heating resistances:
Terminal box CG47 : 6,5 W
Terminal box WTBX-XS : 6,5 W
Terminal box WTBX-S : 56 W
Terminal box WTBX-M : 112 W
Terminal box WTBX-L : 112 W
Terminal box CEFG 340 : 112 W
Terminal box CEFG 500 : 112 W
Terminal box WTBX-XL : 112 W
Maximum operating thresholds of the temperature sensors:
For the winding: 155°C ± 5°C.
For the bearing: 120°C ± 5°C.
The motors W22XdbC…T.. 710 can only be used at ambient temperature down to -20°C.

MARKING

Marking has to be readable and indelible; it has to include the following indications:
• WEGeuro Indústria Eléctrica S.A
• 4470-605 MAIA – 4780-165 SANTO-TIRSO
• W22XdbC...T… (*)
• IECEx INE 12.0011X
• (Serial number)
• Ex db IIC T4 or T3 Gb, Ex db eb IIC T4 or T3 Gb,
• Ex db ia IIC T4 or T3 Gb, Ex db ib IIC T4 or T3 Gb, Ex db eb ia IIC T4 or T3 Gb, Ex db eb ib IIC T4 or T3 Gb,
• Ex tb IIIC T125°C or T135°C Db, Ex ia tb IIIC T125°C or T135°C Db, Ex ib tb IIIC T125°C or T135°C Db
• IP65 or IP66
• T.amb: (**)
• T.Cable: (***)
• Cable entries: (type and size)
• WARNINGS:
o DO NOT OPEN WHEN ENERGIZED.
o DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT.

When the terminal box is protected by increased safety the following indications:
• (rated voltage and rated current and/or rated power)
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0011X
IECEx INE 12.0011X-01_Annex.pdf Issue No.: 01
Page 2 of 5
Annex: IECEx INE 12.0011X-01_Annex.pdf

When the terminal box is located outside of the motor and connected with a cable to the motor the following indications:
• IECEx INE 12.0011X
• Ex db IIC T4 or T3 Gb, Ex eb IIC T4 or T3 Gb,
• Ex db ia IIC T4 or T3 Gb, Ex db ib IIC T4 or T3 Gb, Ex eb ia IIC T4 or T3 Gb, Ex eb ib IIC T4 or T3 Gb
• Ex tb IIIC T125°C or T135°C Db, Ex ia tb IIIC T125°C or T135°C Db, Ex ib tb IIIC T125°C or T135°C Db
• IP65 or IP66
• Rated voltage and rated current and/or rated power are mandatory only for "Ex e" version
• WARNINGS:
o DO NOT OPEN WHEN ENERGIZED.
o DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT.

(*) Type is completed by numbers and letters corresponding to the manufacturer variations.

(**) Mandatory mention when the range of the ambient temperatures differs from -20°C, -30°C, -40°C, -55°C to +40°C, +50°C, +60°C
(***) 85°C for ambient 50°C or 95°C for ambient 60°C when the cable glands are fitted on the terminal box.
95°C for ambient 40°C, 105°C for ambient 50°C or 115°C for ambient 60°C when the cable glands are fitted on the blanking cover of
motors supplied by flying leads.
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0011X
IECEx INE 12.0011X-01_Annex.pdf Issue No.: 01
Page 3 of 5
Annex: IECEx INE 12.0011X-01_Annex.pdf

ROUTINE EXAMINATIONS AND TESTS

In accordance with clause 16.1 of the IEC 60079-1 standard, each equipment defined above has to have successfully passed, before delivery, an
overpressure test of a period comprised between 10 and 60 seconds under:

Pressure
Ambient temperature down to
Enclosure type
-20°C -30°C -40°C -55°C
Motor W22X…500 39 bar 53.4 bar 56.6 bar 61.6 bar
Motor W22X…560 39 bar 53.4 bar 56.6 bar 61.6 bar
Motor W22X…630 39 bar 53.4 bar 56.6 bar 61.6 bar
Motor W22X…710 39 bar NA NA NA
Terminal box WTBX-M ----------- 18.6 bar 18.6 bar 18.6 bar
Terminal box WTBX-L 14.4 bar 18.8 bar 18.8 bar 18.8 bar
Terminal box WTBX-XL 15.7 bar 21.5 bar 22.8 bar 24.9 bar
Terminal box CEFGH 340 14.4 bar 19.7 bar 20.9 bar 22.8 bar
Terminal box CEFGH 500 12.2 bar 16.6 bar 17.6 bar 19.2 bar
Adaptor Ex d 14.7 bar 19.2 bar 19.2 bar 19.2 bar

In accordance with § 16.2 of the IEC 60079-1 standard, the following terminal boxes defined above are exempted of routine test due to the fact
that they have undergone a static type test at 4 times the reference pressure under:

Pressure
Ambient temperature down to
Enclosure type
-20°C -30°C -40°C -55°C
Terminal box WTBX-M 37.2 bar ----------- ----------- -----------
Terminal box WTBX-S ----------- ----------- ----------- 42 bar
Terminal box WTBX-XS ----------- ----------- ----------- 35.6 bar
Terminal box CG47 ----------- ----------- ----------- 69.6 bar

In accordance with clause 7.1 of the IEC 60079-7 standard, the intercalary and the terminal boxes type CG47, CEFGH340, CEFGH500,
WTBX-XS, WTBX-S, WTBX-M and WTBX-L protected by increased safety must have successfully passed before delivery a dielectric strength
test on each of the different circuits of the connection units, performed according to the relevant standards, the supply voltage shall be applied
during one minute.
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0011X
IECEx INE 12.0011X-01_Annex.pdf Issue No.: 01
Page 4 of 5
Annex: IECEx INE 12.0011X-01_Annex.pdf

LIST OF THE COMPONENT INTENDED TO BE INSTALLED ON THE MOTOR AND/OR TERMINAL BOXES

Type of Name of IEC IEC IEC IEC IEC


Certificate number
component manufacturer 60079-0 60079-1 60079-7 60079-11 60079-31
Emil A. Peters
Bushing IECEx PTB 08.0032U 2011 ed 6 2007 ed 6 2006 ed.4
GmbH
Emil A. Peters
Bushing IECEx PTB 08.0052U 2011 ed 6 2007 ed 6 2006 ed.4
GmbH
Emil A. Peters
Bushing IECEx PTB 08.0054U 2011 ed 6 2007 ed 6 2006 ed.4
GmbH
Emil A. Peters
Bushing IECEx PTB 09.0004U 2011 ed 6 2007 ed 6 2006 ed.4
GmbH
Emil A. Peters
Bushing IECEx PTB 08.0053U 2004 ed 4 2003 ed 5 2006 ed.4
GmbH
Insulator
CELMEX S.r.l. IECEx CES 15.0015U 2011 ed 6 2014 ed 7 2015 ed.5
bushings
Bushing STAHL IECEx PTB 06.0080U 2007 ed 5 2007 ed 6 2006 ed.4
Line bushing BARTEC GmbH IECEx EPS 13.0045U 2017 ed 7 2014 ed 7
Line bushing BARTEC GmbH IECEx EPS 14.0020U 2017 ed 7 2014 ed 7 2015 ed 5
Line entry BARTEC GmbH IECEx PTB 13.0050U 2011 ed 6 2007 ed 6 2013 ed.2
Line bushing BARTEC GmbH IECEx CML 14.0003U 2017 ed 7 2014 ed 7 2015 ed.5
Conductor
CORTEM S.p.A IECEx CES 10.0003U 2011 ed 6 2014 ed 7 2013 ed.2
sealing bushings
Conductor
STAHL IECEx PTB 06.0081U 2011 ed 6 2014 ed 7
bushing
Blanking plug Emil A. Peters
IECEx PTB 09.0003U 2011 ed 6 2007 ed 6
GmbH
Stopping plugs Hawke IECEx BAS 06.0029U 2011 ed 6 2015 ed.5 2013 ed.2
Threaded Emil A. Peters
IECEx PTB 09.0006U 2011 ed 6 2007 ed 6
adapter GmbH
Adaptors EATON IECEx ITS 16.0015U 2011 ed 6 2014 ed 7 2015 ed.5 2013 ed.2
Connecting
BARTEC GmbH IECEx PTB 07.0007U 2011 ed 6 2015 ed.5
terminal
Terminal blocks
PHOENIX 2017
and protective IECEx KEM 07.0008U 2017 ed 7
CONTACT ed.5.1
conductor
Terminals PHOENIX 2017
IECEx KEM 06.0034U 2017 ed 7
blocks CONTACT ed.5.1
Protective
PHOENIX 2017
conductor IECEx KEM 06.0035U 2017 ed 7
CONTACT ed.5.1
terminal blocks
2017
Terminal block WEIDMULLER IECEx ULD 14.0005U 2017 ed 7
ed.5.1
Range of rail WEG DRIVES IECEx FTZU 12.0005U 2011 ed 6 2015 ed.5
Range of rail WEG DRIVES IECEx FTZU 12.0006U 2011 ed 6 2015 ed.5
Range of rail WEG DRIVES IECEx FTZU 12.0007U 2017 ed 7 2015 ed.5
Range of
WEIDMULLER IECEx SIR 05.0036U 2004 ed 4 2001 ed.3
terminal strips

Terminals PHOENIX 2004 ed 4 2006 ed.4


IECEx KEM 07.0017U
blocks CONTACT
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0011X
IECEx INE 12.0011X-01_Annex.pdf Issue No.: 01
Page 5 of 5
Annex: IECEx INE 12.0011X-01_Annex.pdf

Type of Name of IEC IEC IEC IEC IEC


Certificate number
component manufacturer 60079-0 60079-1 60079-7 60079-11 60079-31
Breathing and
CORTEM/ELFIT IECEx CES 14.0016U 2011 ed 6 2007 ed 6 2006 ed.4 2008 ed.1
Draining valves

Drain Valve FENEX IECEx EXA 13.0001U 2011 ed 6 2007 ed 6 2006 ed.4 2008 ed.1

Control unit STAHL IECEx BVS 07.0029U 2011 ed 6 2014 ed 7 2006 ed.4 2011 ed.6
F.T.M. s.r.l.
Ring-core
Fabbrica
current IECEx CES 13.0015U 2011 ed 6 2015 ed.5
Trasformatori di
transformer
Misura
Phase
Quartzelec 2017
segregated IECEx SIR 10.0147U 2017 ed 7 2013 ed.2
Limited ed.5.1
terminal box
Range of WEG
Auxiliary Equipamentos IECEx BAS 16.0129U 2011 ed 6 2015 ed.5 2013 ed.2
terminal Boxes Eletricos S.A
WEG
Main Terminal
Equipamentos IECEx BAS 14.0175U 2017 ed 7 2015 ed.5 2013 ed.2
Boxes
Eletricos S.A
RSV motor Anti-
FLEXELEC S A IECEx SIR 10.0151U 2011 ed 6 2006 ed.4
condensation
Anti-
ELTRON
condensation IECEx ITS 08.0002U 2011 ed 6 2015 ed.5
CHROMALOX
heater
Self limiting
BARTEC GmbH IECEx KEM 07.0048U 2011 ed 6 2008 ed.1
heating cable
Self-Limiting
BARTEC GmbH IECEx KEM 07.0047U 2011 ed 6 2008 ed.1
Heating Cable
Temperature EPHY-MESS
IECEx IBE 14.0058U 2011 ed 6 2015 ed.5 2011 ed.6 2013 ed.2
sensor Gmbh
Temperature Temperature
IECEx TSA 09.0044U 2004 ed 4 2003 ed 5 2001 ed.3
sensor Controls Pty Ltd
Slot resistance –
thermometer PAUL RÜSTER
IECEx IBE 14.0011U 2011 ed 6 2015 ed.5
and Co GmbH
thermocouples
Resistance
Minco Products
Temperature IECEx DEK 15.0018U 2011 ed 6 2007 ed 6 2006 ed.4
Inc.
Detector

in green: not concerned by major changes of the last standard version


in blue: new component added for this issue

You might also like