CATHODIC PROTECTION CALCULATION


"PIPA UNDERGROUND 2 m, 200 M LENGTH"
SUMMARY OF CALCULATION
1 Pipeline Name Diameter Length Surface Area Factor Breakdown Current Density
2 (m) (m) (m²) (%) (mA/m²)
3 2 m Pipe Dia, underground, 200 m length 2 200 1256.64 10 25
4 CATHODIC PROTECTION FOR EXTERNAL PIPELINE w/o Safety Factor
5 + Safety Factor
6 TOTAL SURFACE AREA (M²) 1,256.64 TOTAL
7 THIS DESIGN COVERS CALCULATION & GROUNDBED DESIGN WITH PREPACKED MAGNESIUM ANODE
8 CATHODIC PROTECTION
9 DESCRIPTION DESIGN FOR VERTICAL
10 SHALLOW GROUNDBED
11 Basic Design Data
12 Backfill Resistivity Ohm-m
13 Design Life Time Years
14 Soil Resistivity Ohm-m
15 Minimum Protective Potential VS Cu/CuSO4 Volt
16 Closed Pottential VS Cu/CuSO4 Volt
17 Magnesium Anode Requirement Based on Current Output
18 Type High Potential Pre-packed
19 Bare Mg Diameter meter
20 Bare Mg Length meter
21 Anode to backfill resistance Ohm
22 Spacing between anode in ground bed meter
23 Number of prepacked anode each groundbed pcs
24 Diameter of prepacked anode meter
25 Length of prepacked anode meter
26 Resistance of prepacked anode to soil Ohm
27 Interference factor
28 Total resistance of groundbed Ohm
29 Single groundbed current output Amp
30 Number of groundbed ea
31 Number of prepacked anode required pcs
32 Magnesium Anode Requirement Based on Weight
33 Anode Capacity Amp.Hr/kg
34 Utilization factor
35 Bare Anode weight (each) kg
36 Minimum anode weight requirement kg
37 Number of prepacked anode required pcs
38 Summary
39 Number of prepacked anode required to be selected pcs
40 Number of groundbed to be selected ea
41 Distance of Each Ground Bed meter
Current Demand
(A)
3.14
3.14
25%
4

ATHODIC PROTECTION
ESIGN FOR VERTICAL
HALLOW GROUNDBED

0.5
20
6.28 2211200
-0.85 27640 0.2764
-1.58

High Potential Pre-packed


0.127
0.512
0.277
1.00
10
0.152
0.762
2.621
2.065
0.598
1.220
4
40

1230
0.8
14.5
712.20
50

50
5
40