CATHODIC PROTECTION CALCULATION


"PIPA UNDERGROUND 2 m, 200 M LENGTH"
SUMMARY OF CALCULATION
1 Diameter Length Surface Area Factor Breakdown Current Density Current Demand
Pipeline Name
2 (m) (m) (m²) (%) (mA/m²) (A)
3 2 m Pipe Dia, underground, 200 m length 2 200 1256,64 10 25 3,14
4 w/o Safety Factor 3,14
CATHODIC PROTECTION FOR EXTERNAL PIPELINE
5 + Safety Factor 25%
6 TOTAL SURFACE AREA (M²) 1.256,64 TOTAL 4
7 THIS DESIGN COVERS CALCULATION & GROUNDBED DESIGN WITH PREPACKED MAGNESIUM ANODE
8 CATHODIC PROTECTION
9 DESCRIPTION DESIGN FOR VERTICAL
10 SHALLOW GROUNDBED
11 Basic Design Data
12 Backfill Resistivity Ohm-m 0,5
13 Design Life Time Years 20
14 Soil Resistivity Ohm-m 6,28
15 Minimum Protective Potential VS Cu/CuSO4 Volt -0,85
16 Closed Pottential VS Cu/CuSO4 Volt -1,58
17 Magnesium Anode Requirement Based on Current Output
18 Type High Potential Pre-packed
19 Bare Mg Diameter meter 0,127
20 Bare Mg Length meter 0,512
21 Anode to backfill resistance Ohm 0,277
22 Spacing between anode in ground bed meter 1,00
23 Number of prepacked anode each groundbed pcs 10
24 Diameter of prepacked anode meter 0,152
25 Length of prepacked anode meter 0,762
26 Resistance of prepacked anode to soil Ohm 2,621
27 Interference factor 2,065
28 Total resistance of groundbed Ohm 0,598
29 Single groundbed current output Amp 1,220
30 Number of groundbed ea 4
31 Number of prepacked anode required pcs 40
32 Magnesium Anode Requirement Based on Weight
33 Anode Capacity Amp.Hr/kg 1230
34 Utilization factor 0,8
35 Bare Anode weight (each) kg 14,5
36 Minimum anode weight requirement kg 712,20
37 Number of prepacked anode required pcs 50
38 Summary
39 Number of prepacked anode required to be selected pcs 50
40 Number of groundbed to be selected ea 5
41 Distance of Each Ground Bed meter 40