MARK
SB = 146 psf < 1,500 psf (OK) SB = 230 psf < 1,500 psf (OK)
Footing Reinforcing Design: (ULT)
Fy = 60 ksi
f'c = 3,000 psi
Reinf = #5 @ 12 "oc (18"oc max) bot cover = 3.0 in
As = 0.31 in2/ft (12 bars total) top cover = 1.5 in
d= 8.0 in
a= 0.6 in = As·Fy / (0.85·f'c·b)
w= 144 plf /ft = P/(BL) + 6M/(BL²) w= 290 plf /ft = P/(BL) + 6M/(BL²)
- 2
Mu = 3.4 kip-ft /ft = w·b /8 Vu = 1.0 k /ft = w·L/2
Mu+ = 0.2 kip-ft /ft = w·a2/2 ɸVc = 7.9 k /ft = ɸ[2(f'c)1/2(12")·d]
Mu,max = 3.4 kip-ft /ft DCR = 0.13 (OK) = Vu / ɸVc ≤ 1.0
ɸMn = 10.7 kip-ft /ft = 0.9As·Fy·(d - a/2)
DCR = 0.31 (OK) = Mu / ɸMn ≤ 1.0